HVAC WORKS FOR PROPOSED OQ SUBSTATION BUILDING @ BISAT (DESIGN AND BUILT)

S.No Description Unit Qty Unit Rate (RO) Amount (RO)

Supply,Installation,testing & commissioning of


CARRIER,Europe Make Air cooled chillers (135 TR
Capacity @ 52 Deg C actual ambient temperature)
Hydronic module working with necessary inbuilt
Single VSD pumps (1W+1 Standby arrangement Sets 2
chiller),micropocessor panel etc suitable for high ambient
temperature of 52 Deg C with anti vibration spring
mounts etc for the equipment as per tender
1 specifications.

Supply,Installation,testing & commissioning of


Flamco/Armstrong, U.K Make pressurization unit with
necessary inbuilt pumps (1W+1 Standby Set 1
arrangement),controller,1 no Bladder type expansion
vessel etc suitable for high ambient temperature of 52
2 Deg C for the proposed 2 chillers. 205780 205780

Supply ,Install,testing & commissioning of SAIVER,Italy


make CHW AHU's floor mounted Double skin
0.6mm thick Housing construction (Total SA Air flow
: 17312 L/Sec with FA intake of 3445L/Sec) inbuilt
with DIDW forward curved centrifugal fan,G4,F8 Sets 2
filters,Heater,DP switches,anti vibration pads,3-Way
Cooling Valves,Y- strainers,DRV's,Isolating
valves,AAV,Drain cock,Test
points,thermometer,pressure gauge with
syphon,Condensate drain pipe termination,Motorized
fresh air volume control dampers,Sand trap louver
3 with mixing box plenum,etc for substation building per
tender
specifications (1 Working+1 Standby arrangement)
Supply & Install Nuaire/Xpelair/S & P Make 2500
L/Sec airflow Capacity Wall mounted explosion proof Nos 2 3150 6300
Battery room exhaust fan (1 W+1SB) with necessary
4 controls as per design drawings and tender specifications
Supply & Install General,Thailand Make 7.03 KW
Capacity DX High wall split units for Clean Agent room
(2 working+1standby) air-conditioning with necessary Nos 3 690 2070
Cu.Ref piping,Insulation,Condensate drain pipe
termination as per design drawings and tender
5 specifications
Supply & Install Nuaire/Xpelair/S & P Make 232 L/Sec
airflow Capacity Wall mounted toilet exhaust fan with
No 1 745 745
necessary control wiring as per design drawings and
6 tender specifications
Supply & Install Nuaire/Xpelair/S & P Make 243 L/Sec
airflow Capacity Wall mounted toilet exhaust fan with No 1 745
745
necessary control wiring as per design drawings and
7 tender specifications
Supply & Install General,Thailand Make 7.03 KW
Capacity DX High wall split units for Guard house
room (1 working+1standby) air-conditioning with Nos 2 690 1380
necessary Cu.Ref piping,Insulation,Condensate drain
pipe termination as per design drawings and tender
8 specifications
Supply & Install KDK/Xpelair/Panasonic Make 20
L/Sec airflow Capacity Wall mounted toilet& pantry
exhaust fan for Guard house Toilet & Pantry with Nos 2 55 110
necessary control wiring as per design drawings and
9 tender specifications

Supply & installation of MS Schedule 40 CHW Piping


with KIMMCO Make 50mm thick CHW pipe
Lot 1 4850 4850
Insulation for external exposed pipes wrapped with cora
cloth and 2 coats of vapour barrier finally hammered
with 0.8mm thick Al.Cladding (only exposed pipes)for
10 the CHW piping as per design drawings.

Supply & Installation of Manual Chemical dosing


system to monitor the CHW quality in system with Lot 1 2540 2540
necessary microprocessor controller and control wiring
11 as per manufacturer standards
Charges towards water filling,CHW pipe pressure test
& Chemical flushing with approved chemicals with
3rd party lab test reports (i.e Initial flushing,dynamic Lot 1 1890 1890
flushing & final flushing)to obtain final approval for
12 water filling
in CHW system

Supply & Installation of GI type duct work(20 Guage, 22


Gauge and 24 Gauge thickness) with 50mm
thick,48Kg/m3 density rigid slab fibre glass insulation Lot 1 40675 40675
wrapped with cora cloth and 2 coats of vapour barrier
for all Supply air,retur air & fresh air duct work with
stiffeners,supports and fittings etc for AHU for
13 Substation building as per HVAC tender specifications

Supply & Installation of 0.9mm thick Al.Cladding for


only outdoor exposed duct work as per tender Lot 1 4480 4480
14 specification

Supply & Installation of AIR MASTER Make manual


Fire dampers,non return gravity dampers,motorized Lot 1 860 860
Volume control dampers, exhaust louver with
15 washable
Al Filter as per tender specifications
Supply & Installation fo GI manual Volume Control
Duct dampers only for main ducts and branch ducts Lot 1 1465 1465
for air balalncing purpose in full facility as per
16 tender specifications

Supply & Installation fo AIRMASTER Make Lot 1 7950


7950
Grill,registers,square diffusers and exhaust louvers as per
17 tender specifications

Supply & Installation of Complete DDC Control


panel with control cabling,Star-Delta,D.O.L
Starters,relays,thyristor heater controllers,HMI
display controllers,Differential pressure
Lot 1 19620 19620
sensors,Heaters and Chiller+AHU interlock with
duty+standby change over
facility,thermostats,humidity sensors, including
programming,testing and commissioning for respective
18 AHU's,Motorized dampers & Exhaust units as
mentioned in tender specifications
Supply & Installation of Complete PLC panel with
control cabling,Thermowell temp sensors in main CHW Lot 1 2150 2150
header pipes,motorized butterfly valves,sensors etc for
operation of 2 Chillers with necessary control wiring
19 and
timer panel as per site condition.

Allow for HSE training,documentation as per OQ tender


specs including procurement of tools,spares and Lot 1 3200 3200
instrumentation devices with calibration and certification
20 as mentioned in tender specifications

Allow for FAT test for proposed AHU & Chiller Lot 1 4500 4500
Factory (For max of 4 Pax for 3 days) as mentioned in
21 tender specifications
Allow for complete Design HVAC shop
drawings,heat load calculations,Material approvals
including samples,final air balancing and final Lot 1 2500 2500
water balancing including TAB reports as
22 mentioned in tender specifications

Civil work like wall/slab opening and closing with


painting,dog house,waterproofing and fire stop sealant
for routing SA/RA ducts,exhaust fan louvers,motorized
dampers and FAD is excluded.Providing Conrete Excluded (By Main
Lot 1
pedestal/platform/floating floor plinth at external Contractor)
HVAC Space allocated outside the building for
installation of Chillers,Pressurization unit, AHU,dosing
system,DX Split AC ODU's etc as mentioned in HVAC
23 tender specifications

Electrical work like providing 415V/3Ph/50 Hz power


supply cabling for 2 AHU's,1 heater,Exhaust units &
Chillers with necessary Cu.Armoured power cabling and Excluded (By Main
earthing etc from Main DB till DDC Control panel Lot 1
Contractor)
inside the substation building room and from DDC
panel till AHU,Chiller & Exhaust fan equipments with
necessary TPN Weather proof isolators/MCCB's etc as
24 per tender
specifications
Electrical works like providing GI Trunking/Cable tray
with Containment & Conduit pipes within substation
building for routing AHU,Motorized dampers,Exhaust Excluded (By Main
Lot 1
fan control cabling,field sensors power and control Contractor)
cabling & Thermostat wiring till respective locations as
25 per site condition

Allow for locable storage space,CRANE/Hoisting


Excluded (By Main
arrangement for loading and unloading of equipments at Lot 1
Contractor)
site,food and accomodation (Max 8 Pax) for our
26 installation team at Bisat site

Electrical work like providing 240V/1Ph/50 Hz power


supply for pressurization unit,Exhaust
Excluded (By Main
fans,dampers,motorized butterfly valves & DX split Lot 1
Contractor)
units system with controllers with necessary 20
A,Single ph isolators and earthing etc as per equipment
27 manufacturer
recommendations

TOTAL PRICE FOR ABOVE MENTIONED DESIGN & BUILT HVAC WORKS EXCLUDING VAT 313810
5%

RIAL OMANI THREE HUNDRED AND THIRTEEN THOUSAND EIGHT HUNDRED AND TEN ONLY