You are on page 1of 17

M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

GANDY RESIDENCE 5575 Stousland Rd.


College Station, TX 77845
(832) 423-2977
www.laymonconsulting.com

TX Firm # F-19205

© 2022
L

3404 47th STREET Laymon Consulting, LLC


All rights reserved
The arrangements
LUBBOCK, TEXAS 79413 depicted herein are the
sole property of Laymon
Consulting, LLC and may
not be reproduced in any
form without written
permission.
K
J

10/24/2022 CONSTRUCTION SET


ABBREVIATIONS STRUCTURAL DRAWING LIST
SHEET
H

ABV. DESCRIPTION ABV. DESCRIPTION ABV. DESCRIPTION SHEET DESCRIPTION


NUMBER
ADDL ADDITIONAL GA GAUGE P AXIAL FORCE S000 TITLE SHEET
ALT ALTERNATE GALV GALVANIZED PAF POWER ACTUATED FASTENER S001 SPECIFICATIONS
APB ANTHONY POWER BEAM GLU GLULAM LUMBER PCF POUNDS PER CUBIC FOOT S002 SPECIFICATIONS
APPROX APPROXIMATELY GR GRADE PERP PERPENDICULAR S010 FOUNDATION INFORMATION SHEET

Gandy Residence
ARCH ARCHITECT / ARCHITECTURAL PL PLATE S020 FRAMING INFORMATION SHEET
HEX HEXIGON, HEXAGONAL PLF POUNDS PER LINEAR FOOT S021 FRAMING INFORMATION SHEET

Lubbock, TX 79413
BET BETWEEN HORIZ HORIZONTAL PSF POUNDS PER SQUARE FOOT S030 SHEARWALL INFORMATION SHEET
BF BOTH FACES HP HIGH POINT PSI POUNDS PER SQUARE INCH S031 SHEARWALL INFORMATION SHEET

3404 47th St.


B/FTG BOTTOM OF FOOTING HSB HIGH STRENGTH BOLT PSL PARALLEL STRAND LUMBER S040 CMU INFORMATION SHEET
G

BLDG BUILDING HSS HOLLOW STRUCTURAL SECTION PT POINT S101 SLAB FORMING PLAN
BM BEAM HT HEIGHT S102 FOUNDATION PLAN
BOT BOTTOM R RADIUS S201 1ST FLOOR FRAMING PLAN
BPL BASE PLATE ID INSIDE DIAMETER RE REFERENCE S202 CEILING JOIST FRAMING PLAN
BS BOTH SIDES IF INSIDE FACE REBAR REINFORCING BAR S203 ROOF RAFTER FRAMING PLAN
B/ST BOTTOM OF STEEL IN INCH / INCHES REINF REINFORCE(ING) S301 SHEARWALL PLAN
INT INTERIOR REQ REQUIRED S401 FOUNDATION SECTIONS
C CHANNEL REV REVISION S402 FRAMING SECTIONS
CANT CANTILEVER JT JOINT RSRS ROOF SHEATHING RING SHANK NAIL
CJ CONSTRUCTION JOIST
F

CL CENTERLINE K KIP = 1,000 LBS SCHED SCHEDULED


CLR CLEAR KLF KIPS PER LINEAR FOOT SIM SIMILAR
COL COLUMN KSF KIPS PER SQUARE FOOT SF SQUARE FOOT
CONC CONCRETE KSI KIPS PER SQUARE INCH SL SNOW LOAD
CONN CONNECTION SOG SLAB ON GRADE
CONST CONSTRUCTION L LENGTH, STEEL ANGLE SPA SPACE(D)(ING)
CONT CONTINUOUS LB POUND SQ SQUARE
CTRL JT CONTROL JOINT LBS POUNDS SS STAINLESS STEEL
LG LONG STD STANDARD
d PENNY (NAIL SIZE) LIN LINEAR OR LINEAL STIFF STIFFENER
E

D DEPTH, DEEP LL LIVE LOAD STRUCT STRUCTURAL


DBA DEFORMED BAR ANCHOR LLH LONG LEG HORIZONTAL
DEMO DEMOLITION LLV LONG LEG VERTICAL T&B TOP AND BOTTOM
DET DETAIL LP LOW POINT T&G TONGUE AND GROVE
DIA DIAMETER LSH LONG SIDE HORIZONTAL THK THICK
DIAG DIAGONAL LSL LAMINATED STRAND LUMBER T/CONC TOP OF CONCRETE
DIM DIMENSION LSV LONG SIDE VERTICAL T/FTG TOP OF FOOTING
DL DEAD LOAD LT LIGHT TL TOTAL LOAD
Issued For Date
DWG DRAWING LVL LAMINATED VENEER LUMBER TOPG TOPPING
LW LIGHT WEIGHT T/SL TOP OF SLAB Construction 10/24/2022
D

E MODULUS OF ELASTICITY T/ST TOP OF STEEL


EA EACH M MOMENT FORCE TS STRUCTURAL STEEL TUBE
EF EACH FACE MAX MAXIMUM T/WALL TOP OF WALL
EJ EXPANSION JOINT MC MOMENT CONNECTION TYP TYPICAL
EL ELEVATION MEP MECHANICAL ELECTRICAL PLUMBING
EMB EMBEDMENT MID MIDDLE UNO UNLESS NOTED OTHERWISE
EOR ENGINEER OF RECORD MIN MINIMUM UON UNLESS OTHERWISE NOTED
EQ EQUAL MF MOMENT FRAME UPA UNDER POST ABOVE
EW EACH WAY MPH MILE PER HOUR UWA UNDER WALL ABOVE
EXIST EXISTING
C

EXP EXPANSION NF NEAR FACE VERT VERTICAL


EXT EXTERIOR NIC NOT IN CONTACT VIF VERIFY IN FIELD
NO NUMBER
FF FAR FACE NOM NOMINAL W/ WITH
FFE FINISH FLOOR ELEVATION NS NEAR SIDE WF WIDE FLANGE
FFL FINISH FLOOR LEVEL NTS NOT TO SCALE WL WIND LOAD
FDN FOUNDATION NW NORMAL WEIGHT W/O WITHOUT
FIN FINISHED WP WORK POINT
FL FLOOR OC ON CENTER WT WEIGHT
FRTW FIRE RETARDANT TREATED WOOD OD OUTSIDE DIAMETER WWF WELDED WIRE FABRIC
B

FS FAR SIDE OF OUTSIDE FACE


FT FOOT / FEET OH OPPOSITE HAND
FTAO FORCE TRANSFER AROUND OPENING OPNG OPENING LC Project No.: 1803.011
FTG FOOTING OPP OPPOSITE
FY YIELD STRESS OSB ORIENTED STRAND BOARD TOTAL SHEET COUNT 17
Scale: None

Title
Sheet
A

S000
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

CODES AND STANDARDS DESIGN LOADS CONCRETE SPECIFICATIONS CONCRETE MASONRY UNIT SPECIFICATIONS
1. WHERE DOCUMENTS ARE REFERENCED IN THE GENERAL AND DESIGN NOTES, THEY SHALL 1. FLOOR LIVE LOADS 40 PSF 1. ALL CONCRETE MIX SHALL BE DESIGNED BY A QUALIFIED REGISTERED ENGINEER AND LAB 1. MASONRY WORK SHALL COMFORM TO ALL REQUIREMENTS OF TMS 402 (FORMERLY
M

BE THE LATEST APPLICABLE EDITIONS, UNLESS NOTED OTHERWISE. CONCRETE MIX DESIGN DATA RESULTS SHALL BE SUBMITTED TO THE STRUCTURAL DESIGNATED AS ACI 530), "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES"
2. ROOF LIVE LOAD 20 PSF ENGINEER OF RECORD A MINIMUM OF 5 DAYS PRIOR TO THE START OF WORK. AND TMS 602 (FORMERLY DESIGNATED AS ACI 530.1), "SPECIFICATIONS FOR MASONRY
2. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE 2015 INTERNATIONAL 2. TABLE OF MIX DESIGN REQUIREMENTS STRUCTURES."
RESIDENTIAL CODE WITH CITY OF LUBBOCK AMENDMENTS, INCLUDING REFERENCE 3. ROOF SNOW LOAD 15 PSF 5575 Stousland Rd.
STANDARDS, ADDENDA, AND APPENDICES. 2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90, TYPE-I (MOISTURE College Station, TX 77845
STRENGTH TEST AGE MAXIMUM EXPOSURE AIR
MEMBER TYPE/LOCATION CONTROLLED), MEDIUM WEIGHT (115 PCF) UNITS. (832) 423-2977
f'c (psi) (days) AGGREGATE CLASS CONTENT
3. IN ADDITION, THE FOLLOWING CODES, STANDARDS, AND SPECIFICATIONS SHALL APPLY www.laymonconsulting.com
WHERE MORE STRINGENT AND AS MODIFIED BY THE BUILDING CODE: 5.9 psf 3. MORTAR SHALL CONFORM TO ASTM C270. MORTAR TYPE SHALL BE TYPE M OR TYPE S.
SLAB-ON-GRADE 3,000 28 1" - 0 - 112%
MASONRY CEMENT AND RETARDANT ADDITIVES SHALL NOT BE USED. TX Firm # F-19205
A. ACI 310 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE AND FOOTINGS 3,000 28 1" - 0 - 112%
COMMENTARY" ROOF TRUSS MASONRY ASSEMBLAGE SCHEDULE
B. AISC "STEEL CONSTRUCTION MANUAL" © 2022
COMPRESSIVE STRENGTH OF
L

C. ASCE 7: MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR BUILDINGS AND MORTAR COMPRESSIVE STRENGTH OF
BALANCED LOAD DIAGRAM MASONRY ASSEMBLAGE, f'm TYPE INDIVIDUAL MASONRY UNIT
Laymon Consulting, LLC
OTHER STRUCTURES NOTES
All rights reserved
D. NDS: NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION 1. W/C RATIO: WATER-CEMENTITIOUS MATERIAL RATIOS SHALL BE BASED ON THE TOTAL
4. WIND LOAD WEIGHT OF CEMENTITIOUS MATERIALS. MAXIMUM RATIOS ARE CONTROLLED BY THE
1,500 PSI M OR S 1,900 PSI The arrangements
E. AWS D1.1 "STRUCTURAL WELDING CODE - STEEL"
F. AWS D1.4 "STRUCTURAL WELDING CODE - REINFORCING STEEL" BASIC DESIGN WIND SPEED, V 106 MPH STRENGTH NOTED ABOVE AND DURIBILITY REQUIREMENTS GIVEN IN ACI 318 SECTION 4.3 depicted herein are the
2,000 PSI M OR S 2,800 PSI
G. ACI 530/530/1 "BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY ASD WIND SPEED, VASD 90 MPH sole property of Laymon
STRUCTURES AND RELATED COMMENTARIES" RISK CATEGORY II 2. CEMENTITIOUS MATERIALS: 2,500 PSI M OR S 3,750 PSI Consulting, LLC and may
H. ACI 305.1 "SPECIFICATIONS FOR HOT WEATHER CONCRETING" WIND EXPOSURE CATEGORY B A. THE USE OF FLY ASH, OTHER POZZOLANS, SILICA FUME, OR SLAG SHALL CONFORM 3,000 PSI M OR S 4,800 PSI not be reproduced in any
I. ACI 306.1 "SPECIFICATIONS FOR COLD WEATHER CONCRETING" INTERNAL PRESSURE COEF ± 0.18 TO ACI 318 SECTIONS 4.3.1 AND 4.4.2. THE MAXIMUM AMOUNT OF FLY ASH SHALL BE form without written
COMPONENT & CLADDING PRESSURES (ASD): 20% OF TOTAL CEMENTITIOUS CONTENT, UNLESS REVIEWED AND APPROVED permission.
ZONE 1 16.0/-16.0 PSF OTHERWISE BY THE STRUCTURAL ENGINEER OF RECORD.
ZONE 2 16.0/-16.0 PSF B. FLY ASH SHALL CONFORM TO ASTM C618, CLASS F 4. GROUT SHALL CONFORM TO ASTM C476, SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602,
K

PROJECT DOCUMENTS ZONE 3


ZONE 4
16.0/-29.8 PSF
16.0/-23.2 PSF
C. CEMENTITIOUS MATERIALS SHALL CONFORM TO THE RELEVANT ASTM STANDARDS
LISTED IN ACI 318 SECTION 3.2.1
SHALL HAVE A COMPRESSIVE STRENGTH THAT MEETS OR EXCEEDS f'm BUT IS NOT LESS
THAN 2,000 PSI, SHALL HAVE A MAXIMUM AGGREGATE SIZE OF 3 8", SHALL BE FREE OF
1. THIS SET OF DRAWINGS, TOGETHER WITH THE SPECIFICATIONS AND OTHER CONSULTANT ZONE 5 16.0/-28.7 PSF CHLORIDE, AND SHALL HAVE A MINIMUM 8" SLUMP.
DRAWINGS, CONSTITUTES THE COMPLETE DOCUMENT BY WHICH ALL WORK IS TO BE a= 3'-3" 3. AIR CONTENT: CONFORM TO ACI 318 SECTION 4.4.1. MINIMUM STANDARDS FOR
CARRIED OUT. EXPOSURE CLASS ARE NOTED IN THE TABLE. IF FREEZING AND THAWING CLASS IS NOT 5. WATER SHALL BE CLEAN AND POTABLE.
NOTED, AIR CONTENT GIVEN IS THAT REQUIRED BY THE STRUCTURAL ENGINEER OF
2. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS AT THE JOB 3
RECORD. TOLERANCE IS ±1 12%. AIR CONTENT SHALL BE MEASURED AT POINT OF 6. MASONRY REINFORCING STEEL SHALL CONFORM TO THE REINFORCING STEEL
SITE. THE CONTRACTOR SHALL US THE STRUCTURAL DRAWINGS IN CONJUNCTION WITH THE 2 PLACEMENT. SPECIFICATIONS.
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, CIVIL, AND ALL 3 2
OTHER RELEVANT CONSULTANTS DRAWINGS BEFORE COMMENCING WITH THE WORK AND 1 4. AGGREGATES SHALL CONFORM TO ASTM C33. LIGHTWEIGHT AGGREGATES SHALL 7. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 48 BAR DIAMETERS AND SHALL BE
SHALL NOTIFY THE ARCHITECT AND ENGINEER OF ANY DISCREPANCIES REQUIRING 1 5
2 CONFORM TO ASTM C330 WIRED TOGETHER THROUGHOUT THE SPLICE LENGTH.
CLARIFICATION OR REVISION. 5 2 1
3 2
J

a 5. SLUMP: CONFORM TO ACI 301 SECTION 4.2.2.2. SLUMP SHALL BE DETERMINED AT POINT 8. JOINT REINFORCEMENT SHALL CONFORM TO ASTM A951 AND SHALL BE NINE (9) GAUGE
3. SCALES NOTED ON THE DRAWINGS ARE FOR GENERAL INFORMATION ONLY. NO 2 4 3 5
a OF PLACEMENT. LADDER OR TRUSS TYPE. LAP SPLICES SHALL BE 12" MINIMUM.
INFORMATION SHALL BE OBTAINED BY SCALING FROM THE DRAWINGS. 4 3 5 4
4 5 5 a 6. CHLORIDE CONTENT: CONFORM TO ACI318 SECTION 4.3.1. 9. SECOND HAND UNITS SHALL NOT BE ALLOWED.
4. IN THE EVENT THAT CERTAIN DETAILS OF THE CONSTRUCTION ARE NOT FULLY SHOWN OR
NOTED ON THE DRAWINGS, THEIR CONSTRUCTION SHALL BE OF THE SAME TYPE AS FOR 5 5 a
7. NON-CHLORIDE ACCELERATOR: NON-CHLORIDE ACCELERATOR ADMIXTURE MAY BE 10. ALL REINFORCING IN MASONRY SHALL BE ACCURATELY LOCATED PRIOR TO GROUTING AND
SIMILAR CONDITIONS THAT ARE SHOWN OR NOTED, SUBJECT TO THE APPROVAL OF THE a a USED AT AMBIENT TEMPERATURES BELOW 50°F AT THE CONTRACTOR'S OPTION. THE POSITION MAINTAINED DURING GROUTING.
STRUCTURAL ENGINEER OF RECORD. a a
8. ACI 318 SECTION 4.2.1 EXPOSURE CLASSES SHALL BE ASSUMED TO BE F0, S0, P0, AND C0 11. ALL CELLS AND COURSES WITH REINFORCING SHALL BE FILLED SOLID WITH GROUT.
5. GEOTECHNICAL DOCUMENT INFORMATION CAN BE FOUND IN THE "DESIGN LOADS" SECTION UNLESS DIFFERENT EXPOSURE CLASSES ARE LISTED IN THE ABOVE TABLE THAT MODIFY ADDITIONAL CELLS AND COURSES MAY REQUIRE GROUTING AS SHOWN ON PLAN OR IN THE
OF THESE GENERAL NOTES. THESE BASE REQUIREMENTS. CMU INFORMATION SHEET. ARCHITECTURAL DRAWINGS MAY ALSO REQUIRE ADDITIONAL
5. EARTHQUAKE LOAD CELLS AND COURSES TO BE FILLED BASED ON FIRE AND SOUND REQUIREMENTS.
6. OPENINGS, POCKETS, ETC., LARGER THAN 6" SHALL NOT BE PLACED IN CONCRETE SLABS
H

RISK CATEGORY II 3. CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301, LATEST EDITION.
AND WALLS UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS. NOTIFY THE SEISMIC IMPORTANCE FACTOR 1.0 12. GROUT LIFTS AND POUR HEIGHTS SHALL NOT EXCEED 5FT 4IN, UNLESS OTHERWISE NOTED
STRUCTURAL ENGINEER OF RECORD WHEN DRAWINGS BY OTHERS SHOW OPENINGS, SS 0.076 4. CONCRETE SHALL BE PLACED CAREFULLY SO AS NOT TO DEVIATE TENDONS AND OR APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
POCKETS, ETC., LARGER THAN 6" WHICH ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS S1 0.03 REINFORCEMENT FROM THEIR DESIGN LOCATIONS.
BUT WHICH ARE LOCATED IN STRUCTURAL ELEMENTS. SITE CLASS D 13. GROUT SHALL BE PLACED CONTINUOUSLY AND LIFTS SHALL NOT BE PLACED MORE THAN
SDS 0.081 5. CONCRETE SHALL BE PROPERLY VIBRATED, ESPECIALLY AROUND POST-TENSIONING ONE HOUR APART. GROUT IN VERTICAL CELLS SHALL BE MECHANICALLY VIBRATED
7. DEPRESSIONS IN SLABS SHALL NOT BE PLACED UNLESS SPECIFICALLY SHOWN ON THE SD1 0.072

Gandy Residence
ANCHORS AND IN CONGESTED AREAS. IMMEDIATELY AFTER POURING AND AGAIN FIVE(5) MINUTES LATER. RODDING OF THE GROUT
STRUCTURAL DRAWINGS. NOTIFY THE STRUCTURAL ENGINEER OF RECORD WHEN SEISMIC DESIGN CATEGORY A IS NOT ACCEPTABLE.
DRAWINGS BY OTHERS SHOW DEPRESSIONS WHICH ARE NOT SHOWN ON THE STRUCTURAL 6. THE FORMING AND SHORING SYSTEM SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR

Lubbock, TX 79413
DRAWINGS. 6. GEOTECHNICAL INFORMATION AND SHOULD BE DESIGNED BY A COMPETENT DESIGNERS EMPLOYED BY THE FORM 14. CMU WALLS SHALL BE CONSTRUCTED PLUMB AND LEVEL
GEOTECHNICAL FIRM NONE SUPPLIER.
8. ALL SUSPENDED LOADS (MEP DRAWINGS, INTERIOR DRAWINGS, FIRE PROTECTION

3404 47th St.


REPORT NUMBER 15. CONSTRUCTION PHASE BRACING OF THE MASONRY IS THE RESPONSIBILITY OF THE
DRAWINGS, ETC.)EXCEEDING 300 POUNDS SHALL BE REVIEWED BY THE STRUCTURAL
G

REPORT DATE 7. CONCRETE FOR CYLINDERS AND SLUMP TEST SHALL BE TAKEN EVERY 50CY OF CONCRETE GENERAL CONTRACTOR.
ENGINEER OF RECORD PRIOR TO INSTALLATION, UNLESS SPECIFICALLY DETAILED ON THE BEARING CAPACITY 1,500 PSF (ASSUMED TOTAL LOAD) AT THE POINT OF PLACEMENT.
STRUCTURAL DRAWINGS. THE CONTRACTOR SHALL SUBMIT ONE COMPOSITE PLAN PER
FLOOR LEVEL WHICH INCLUDES ALL POINT LOADS OF ALL TRADES. ALL LOADS EXCEEDING a. STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS 8. THE MAXIMUM SLUMP IN CONCRETE SHALL NOT EXCEED 5"
300 POUNDS SHALL BE INCLUDED IN THOSE PLANS. ENCOUNTERED IN THE FIELD DIFFERENT FROM THOSE ASSUMED FOR DESIGN.

9. THE INFORMATION SHOWN FOR NON-STRUCTURAL ELEMENTS/FINISHED IS GIVEN FOR b. GEOTECHNICAL TESTING/INSPECTION AGENCY SHALL CERTIFY THE BEARING
9. WATER MAY NOT BE ADDED TO THE BATCH AT THE SITE UNLESS IT IS SPECIFICALLY NOTED
THAT IT MAY BE ADDED ON THE TICKET PROVIDED BY THE READY-MIX COMPANY. IN NO CASE
LOOSE LINTEL SPECIFICATIONS
REFERENCE ONLY. THE CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DRAWINGS MEDIUM BEFORE STARTING CONSTRUCTION. 1. SEE STRUCTURAL STEEL SPECIFICATIONS FOR ANGLE STANDARDS AND GALVANIZING
MAY MORE WATER BE ADDED TO THE MIX THAN IS ALLOWED ON THE TICKET.
FOR THIS INFORMATION. REQUIREMENTS.
10. UNREINFORCED AND CONVENTIONALLY REINFORCED CONCRETE SHALL HAVE
10. CLADDING/FACADE/STAIR CONNECTIONS TO THE STRUCTURE SHALL NOT INTRODUCE 2. LOOSE LINTELS SHALL BE SIZED BASE ON THE FOLLOWING CLEAR SPANS:
CONSTRUCTION JOINTS OR CONTROL JOINTS AS SHOWN ON THE DRAWINGS AND
TORSION AND UNACCEPTABLE LOAD ECCENTRICITIES TO STRUCTURAL MEMBERS. SUCH 7. FLOOD LOAD N/A COORDINATED WITH THE ARCHITECT. IF JOINTS ARE NOT SHOWN, A MINIMUM SPACING OF
CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER OF
F

(30 x SLAB THICKNESS (in)) MAY BE USED. CONTROL JOINTS SHOULD BE SAWED AS SOON AS CLEAR SPAN SIZE
RECORD, WHO MAY REQUIRE ADDITIONAL BRACING TO BE PROVIDED BY THE PRACTICALLY POSSIBLE. JOINTS SHOULD BE SAWED AS SOON AS THE CONCRETE WILL
CLADDING/FACADE CONTRACTOR AT NO ADDITIONAL COST TO THE CONTRACTOR. WITHSTAND THE ENERGY OF SAWING WITHOUT RAVELING OR DISLODGING AGGREGATE
L 3 12 x 3 12 x 5 16 LLV
REINFORCING STEEL SPECIFICATIONS PARTICLES. 0'-0" UP TO 4'-0"

1. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC DEFORMED BILLET STEEL CONFORMING OVER 4'-0" UP TO 8'-0" L 5 x 3 12 x 5 16 LLV
11. HORIZONTAL JOINTS IN THE FOUNDATION SHALL NOT BE ALLOWED, UNLESS NOTED ON THE
TO ASTM A615, GRADE 60 BARS.
BUILDING PAD SPECIFICATIONS DRAWINGS. OVER 8'-0" UP TO 11'-0" L 6 x 3 12 x 5 16 LLV
1. THE BUILDING PAD SHALL BE PREPARED SUCH THAT THE PVR DOES NOT EXCEED 1". REFER 2. WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185 AND SHALL BE PROVIDED IN
TO THE GEOTECHNICAL REPORT RECOMMENDATIONS. 12. PRIOR TO CONSTRUCTING FORMS OR PLACING CONCRETE, CONTRACTOR SHALL VERIFY
FLAT SHEETS. ROLLED SHEETS ARE NOT ACCEPTABLE. LAP FABRIC TWO MESHES, BUT NOT 3. SIZES SHOWN ABOVE ARE BASED ON A MAXIMUM OF 5'-0" OF BRICK ABOVE THE LINTEL.
FINISHED WITH ARCHITECT.
LESS THAN 12", AT SPLICE LOCATIONS.
2. ALL FOOTINGS AND GRADE BEAMS SHALL BEAR A MINIMUM OF 24" BELOW FINISHED GRADE. 4. LOOSE LINTELS SUPPORTING MORE THAN 5''-0" OF BRICK ABOVE THE LINTEL OR WITH SPANS
13. PRIOR TO CONSTRUCTING FORMS OR PLACING CONCRETE, CONTRACTOR SHALL NOTIFY
3. DETAILING OF CONCRETE REINFORCEMENT BARS AND ACCESSORIES SHALL CONFORM TO LONGER THAN 11'-0" WILL BE SHOWN ON THE FRAMING PLANS. IF THESE LNTELS ARE NOT
E

3. THE CONTRACTOR SHALL EXCAVATE, PREPARE, AND COMPACT THE BUILDING PAD IN SUBCONTRACTORS TO BE SURE SLEEVES, CONDUIT, CHASES, EMBEDDED ITEMS, BOLTS,
THE RECOMMENDATIONS OF ACI 315. CALLED OUT ON THE PLANS, CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR THE
ACCORDANCE WITH THE GEOTECHNICAL REPORT. BLOCK-OUTS, ETC. ARE FULLY AND PROPERLY INSTALLED. CONTRACTOR SHALL NOTIFY THE
CORRECT LINTEL SIZE TO USE.
4. COMPLETE REINFORCING PLACEMENT DRAWINGS, PREPARED IN ACCORDANCE WITH ACI 315, STRUCTURAL ENGINEER OF RECORD OR OWNER'S REPRESENTATIVE AT LEAST 48 HOURS
4. THE CONTRACTOR SHALL ADVISE THE STRUCTURAL ENGINEER OF RECORD OF ANY SITE SHALL BE REVIEWED BY THE STRUCTURAL ENGINEER OF RECORD AND AVAILABLE ON THE PRIOR TO PLACING CONCRETE TO ALLOW TIME FOR OBSERVATIONS OF FORMS AND
5. LINTEL ANGLES SHALL BEAR A MINIMUM OF 8" ONTO THE BRICK ON EACH END. CONTACT THE
CONDITIONS WHICH MAY NOT BE DESCRIBED ON THE PLANS OR IN THE GEOTECHNICAL JOB SITE PRIOR TO AND DURING THE PLACING OF CONCRETE REINFORCING.
STRUCTURAL ENGINEER OF RECORD IS A SMALLER BEARING LENGTH IS REQUIRED.
REPORT. .
5. ALL REINFORCING BAR BENDS SHALL BE MADE COLD. 14. CONCRETE SHALL BE PROTECTED FROM RAIN AND SNOW.
5. SLABS SHALL NOT BE PLACED ON ANY UNCONSOLIDATED FILL OF ANY SIZE UNLESS THE FILL
HAS BEEN CONSIDERED IN THE DESIGN OF THE FOUNDATION. 6. WELDING OF REINFORCING BARS SHALL NOT BE PERMITTED WITHOUT PRIOR APPROVAL 15. AFTER FINISHING, CONCRETE SHALL BE CURED BY KEEPING CONCRETE DAMP AND COVERED
FROM THE STRUCTURAL ENGINEER OF RECORD. IF WELDING IS PERMITTED, IT SHALL WITH PLASTIC OR BURLAP FOR A MINIMUM OF 72 HOURS. A CRING COMPOUND MAY BE USED Issued For Date
6. UNLESS SPECIFIED OTHERWISE IN THE GEOTECHNICAL REPORT, ALL FILL MATERIAL SHALL CONFORM TO THE REQUIREMENTS OF AWS D1.4. INSTEAD IF APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
BE COMPACTED TO 95% PROCTOR DENSITY AS DETERMINED BY ASTM D698 AND SHALL BE Construction 10/24/2022
D

LAYERED WITH CONSOLIDATED LAYERS OF NO MORE THAN 8" IN THICKNESS. 7. ALL REINFORCING STEEL SHALL BE SUPPORTED USING CHAIRS (PLASTIC, METAL, OR 16. REPAIR HONTCOMBS, SPALLS, RUNS, AND OTHER DAMAGED AREAS AS DIRECTED BY THE
CEMENTITIOUS BLOCKS) AT 48" O.C. EACH WAY. STRUCTURAL ENGINEER OF RECORD.
7. IF ANY PORTION OF THE STRUCTURE IS PLACED ON DEEP FILL, THE STRUCTURAL ENGINEER
OF RECORD SHALL BE NOTIFIED PRIOR TO CONSTRUCTION. 8. ALL SPLICE LOCATIONS ARE SUBJECT TO APPROVAL AND SHALL BE MADE ONLY WHERE
INDICATED ON THE DRAWINGS.
8. TRENCHES FOR BURIED PLUMBING SHALL NOT RUN ALONG OR UNDER THE GRADE BEAMS
EXCEPT TO CROSS AT RIGHT ANGLES. TRENCH BACKFILL SHALL BE THOROUGHLY 9. REINFORCING BAR SPACING GIVEN ARE MAXIMUM ON CENTER. BARS MAY NOT BE BUNDLED
COMPACTED. OR SPACED FARTHER APART UNLESS APPROVED BY THE STRUCTURAL ENGINEER OF
RECORD.
9. ALL SLEEVES THROUGH CONCRETE SHALL BE SCHEDULE 40 GALVANIZED STEEL PIPE OR
PVC. 10. SECURELY TIE ALL BARS IN POSITION BEFORE PLACING CONCRETE.
C

10. GRADE BEAMS AND FOOTINGS SHALL BE CLEAN AND PER PLAN IN SIZE AND LOCATION. 11. END HOOKS, DEVELOPMENT LENGTHS, AND SPLICES SHALL CONFORM TO THE
DIFFERENT SIZES AND LOCATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE REQUIREMENTS OF ACI 318.
STRUCTURAL ENGINEER OF RECORD.
12. MINIMUM COVERAGE FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
11. LOOSE SOILS, CLODS, MUD, STANDING WATER, ICE OR FROST, ORGANICS AND VEGETATION, A. CONCRETE CAST AGAINST EARTH 3"
AND TRASH SHALL BE REMOVED FROM THE GRADE BEAMS, FOOTINGS, AND BUILDING PAD B. CONCRETE CAST AGAINST FORMS 2"
PRIOR TO CONCRETE PLACEMENT. C. FOOTINGS 2" TOP
3" BOTTOM
12. PROVIDE A MINIMUM 10 MIL VAPOR RETARDER OR VAPOR BARRIER OVER THE PREPARED D. SLAB-ON-GRADE CENTER IN SLAB
BUILDING PAD. LAPPING, WHEN REQUIRED, SHALL BE A MINIMUM OF 12" AND SHALL BE
TAPED AT THE JOINTS TO PROVIDE A CONTINUOUS SHEET UNDER THE ENTIRE SLAB.
SECURE THE VAPOR RETARDER/BARRIER TO THE SIDES OF THE GRADE BEAMS AND CUT
B

ALONG THE BOTTOM OF THE GRADE BEAMS TO PREVENT BRIDGING AND MOVEMENT OF THE
RETARDER/BARRIER DURING CONCRETE PLACEMENT.
LC Project No.: 1803.011

Scale: None

Specifications
A

S001
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

LUMBER SPECIFICATIONS
1. DIMENSIONAL LUMBER SHALL BE SOUTHERN YELLOW PINE OR DOUGLAS FIR-LARCH, KILN
M

DRIED TO A MOISTURE CONTENT OF 19%, VISUALLY GRADED, AND CONFORMING TO THE


STRENGTH SPECIFICATIONS OF THE AMERICAN WOOD COUNCIL AND THE NATIONAL DESIGN
SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION.
5575 Stousland Rd.
2. GRADE, SPECIES, AND GRADING AGENCY SHOULD BE MARKED ON EACH PIECE OF LUMBER. College Station, TX 77845
(832) 423-2977
3. UNLESS NOTED OTHERWISE ON THE PLANS, THE GRADE DESIGNATIONS FOR DIMENSIONAL www.laymonconsulting.com
LUMBER SHALL BE AS FOLLOWS:
USE GRADE TX Firm # F-19205
STUDS STUD
SOLID POSTS #2
HEADERS, BEAMS, JOISTS, RAFTERS #2 © 2022
L

BLOCKING SAME AS USE BLOCKING IS USED FOR Laymon Consulting, LLC


TOP PLATES #2 All rights reserved
BOTTOM PLATES #3 TREATED
The arrangements
4. ENGINEERED LUMBER SHALL BE PARALLEL STRAND LUMBER (PSL) OR LAMINATED VENEER
depicted herein are the
LUMBER (LVL) WITH THE FOLLOWING MINIMUM DESIGN VALUES: sole property of Laymon
PROPERTY VALUE Consulting, LLC and may
MODULUS OF ELASTICITY, E 2.0x106 PSI not be reproduced in any
FLEXURAL STRESS, Fb 2,900 PSI form without written
COMPRESSION PARALLEL TO GRAIN, Fc II 2,900 PSI permission.
HORIZ. SHEAR PARALLEL TO GRAIN, Fv 290 PSI
K

5. UNLESS NOTED ON THE PLANS, PSL LUMBER MAY NOT BE SUBSTITUTED WITH ANY OTHER
ENGINEERED LUMBER WITHOUT APPROVAL FROM THE STRUCTURAL ENGINEER OF RECORD.

6. FINGER JOINTED STUDS ARE ACCEPTABLE PROVIDED THE LUMBER IS OF THE SAME SPECIES
AND GRADE AS NOTED ABOVE.

7. ALL STUDS SHALL BE BLOCKED HORIZONTALLY AT MID-HEIGHT (THIRD POINTS ON THE FIRST
FLOOR OF A 4-STORY BUILDING) WHEN SUBJECTED TO CONSTRUCTION LOADING PRIOR TO
BEING SHEATHED.

8. CONSTRUCTION PHASE BRACING OF WALL IS THE RESPONSIBILITY OF THE CONTRACTOR.


J

9. WOOD IN CONTACT WITH CONCRETE, EARTH, WITHIN 8" FROM EXPOSED EARTH, OR EXPOSED
TO WEATHER, SHALL BE PRESSURE TREATED IN ACCORDANCE WITH THE AMERICAN WOOD
PRESERVER'S ASSOCIATION (AWPA) STANDARD U1-02.

10. UNLESS NOTED OTHERWISE, FASTENING SHALL BE PER IBC TABLE 2304.9.1 (IBC 2012).

DECKING AND SHEATHING SPECIFICATIONS


1. SLOPED ROOF DECKING SHALL BE MINIMUM 19 32" APA RATED 40/20 SHEATHING EXPOSURE 1
GRADE T&G PLYWOOD/OSB.
H

2. FLAT ROOF DECKING SHALL BE 23 32" APA RATED 48/24 SHEATHING EXPOSURE 1 GRADE T&G
PLYWOOD/OSB.
3. DECKING BELOW ROOF MOUNTED MECHANICAL UNITS SHALL BE 23 32" APA RATED 48/24
SHEATHING EXPOSURE 1 GRADE T&G PLYWOOD/OSB.
4. FLOOR DECKING SHALL BE 23 32" APA RATED STURD-I-FLOOR 24 O.C. EXPOSURE 1 GRADE T&G
PLYWOOD/OSB.

Gandy Residence
5. WOOD SHEATHING FOR SHEARWALLS AND MISCELLANEOUS USES SHALL BE A MINIMUM 7 16"
APA RATED 24/16 SHEATHING EXPOSURE 1 OSB.

Lubbock, TX 79413
6. PROVIDE A 1 4" GAP EVERY 80 FEET IN PLYWOOD/OSB DECKING AND SHEATHING RUNS
LONGER THAN 80 FEET.
7. EXTERIOR GYPSUM SHEARWALLS SHALL BE 12" MINIMUM TYPE X EXTERIOR RATED GYP

3404 47th St.


SHEATHING. SEE THE ARCHITECTURAL PLANS FOR ADDITIONAL REQUIREMENTS.
G

8. INTERIOR GYPSUM SHEARWALLS SHALL BE 5 8" TYPE X GYPSUM WALLBOARD.

FASTENER SPECIFICATIONS
1. ALL CONNECTORS SHALL MEET THE FOLLOWING REQUIREMENTS:

CONNECTOR STANDARD
F

BOLTS ASTM A307, GRADE A


LAG SCREWS ANSI/ASME B18.2.1
NAILS ASTM F1667
WOOD SCREWS ANSI/ASME B18.6.1
POWER ACTUATED FASTENER ASTM E1190

2. BOLT HOLES SHALL BE 132" TO 116" LARGER THAN THE BOLT DIAMETER. HOLES SHALL BE
ACCURATELY ALIGNED AND BOLTS SHALL NOT BE FORCIBLY DRIVEN.
E

3. LAG SCREW AND WOOD SCREWS LEAD HOLES, WHEN NECESSARY TO AVOID SPLITTING OF
THE WOOD MEMBERS, SHALL HAVE A DIAMETER OF 60% OF THE SHANK DIAMETER. THE
THREADED PORTION OF THE SCREW SHALL BE INSERTED INTO THE LEAD HOLE BY TURNING
WITH A WRENCH OR SCREW DRIVER, NOT BY DRIVING WITH A HAMMER.

4. NAILS SHALL BE COMMON NAILS WITH SIZES AS FOLLOWS:

PENNYWEIGHT SHANK Ø LENGTH Issued For Date


Construction 10/24/2022
6d 0.113" 2"
D

8d 0.131" 2 12"
10d 0.148" 3"
16d 0.162" 3 12"

5. TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF APPROXIMATELY 30° WITH THE MEMBER BEING
TOE-NAILED AND STARTED APPROXIMATELY 13 THE LENGTH OF THE NAIL FROM THE MEMBER
END.

6. POWER ACTUATED FASTENERS SHALL BE HILTI X-CP 72 P8 S23 MANUFACTURED BY HILTI.


C

7. HARDWARE SUCH AS STRAPS, HOLDOWNS, AND HANGERS SHALL BE MANUFACTURED BY


SIMPSON STRONG-TIE AND INSTALLED PER THEIR RECOMMENDATIONS.

8. CORROSION RESISTANCE CLASSIFICATION FOR ALL CONNECTORS SHALL BE AS FOLLOWS:

MATERIAL TO BE FASTENED

Untreated PRESERVATIVE-TREATED WOOD


ENVIRONMENT Wood or FRT
SBX-DOT Chemical Chemical Other
Other Wood
Zinc Retention £ Retention > ACZA or
Material
Borate AWPA,UC4A AWPA,UC4A Uncertain
B

INTERIOR USE LOW LOW LOW HIGH MEDIUM HIGH MEDIUM


EXTERIOR USE MEDIUM N/A MEDIUM HIGH HIGH HIGH HIGH
LC Project No.: 1803.011
OCEAN/WATER FRONT SEVERE N/A SEVERE SEVERE SEVERE SEVERE N/A

NOTES Scale: None


A. IF THE INFORMATION ABOUT TREATMENT CHEMICALS IN APPLICATION IS INCOMPLETE,
OR IF THERE IS ANY UNCERTAINTY AS TO THE SERVICE ENVIRONMENT OF ANY
APPLICATION, USE A TYPE 316 STAINLESS STEEL PRODUCT.

B. ANCHORS, FASTENERS, AND CONNECTORS IN CONTACT WITH FRT LUMBER SHALL BE


HOT-DIP GALVANIZED, UNLESS RECOMMENDED OTHERWISE BY THE FRT
Specifications
A

MANUFACTURER.

S002
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

CONVENTIONALLY REINFORCED FOUNDATION INFORMATION SHEET 10. THE SLAB CONSTRUCTION AND THE THICKNESS OF THE SLAB BETWEEN GRADE BEAMS IS SHOWN IN THE FOLLOWING NOTE: 19. ALL GRADE BEAM INTERSECTIONS AT CORNERS AND T'S NEED TO BE TIED TOGETHER WITH ADDITIONAL REBAR PER THE DETAILS BELOW.

STEP 1: HOW TO READ THE PLANS


CONVENTIONAL SLAB
M

CONSTRUCTION
1. CONVENTIONALLY REINFORCED FOUNDATIONS SHALL BE CONSTRUCTED AS SHOWN ON THE FOUNDATION PLANS WITHIN THIS SET OF DRAWINGS.
1. ALL SLAB-ON-GRADE SHALL HAVE A MINIMUM
5575 Stousland Rd.
2. MATERIAL SPECIFICATIONS FOR REINFORCING STEEL AND CONCRETE CAN BE FOUND IN THE SPECIFICATION SECTION AT THE BEGINNING OF THIS THICKNESS AS SHOWN BELOW, UNLESS NOTED
College Station, TX 77845
SET. OTHERWISE ON THE PLAN, AND SHALL BE
(832) 423-2977
REINFORCED WITH REINFORCING STEEL AS SHOWN PROVIDE STANDARD
GRADE BEAM REINFORCING www.laymonconsulting.com
3. THE BUILDING PAD SHALL BE CONSTRUCTED PER THE SPECIFICATIONS AT THE BEGINNING OF THIS SET AND PER THE GEOTECHNICAL REPORT. BELOW AND PLACED MID-HEIGHT IN THE SLAB. HOOKS FOR TOP STEEL
BOTH MUST BE FOLLOWED. IF THERE ARE ANY QUESTIONS OR CONFLICTS, CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR OF THE GRADE BEAMS
TX Firm # F-19205
CLARIFICATION. 2. ALL SLABS SHALL BE PLACED OVER A 10 MIL VAPOR (TYP)
RETARDER OVER A SUBGRADE PREPARED PER THE LOCATED FIRST
GEOTECHNICAL REPORT. TIES/STIRRUPS WITHIN 2" OF
4. FOUNDATION SLAB EDGES AND GRADE BEAMS ARE SHOWN THUS: © 2022
THE INTERSECTION (TYP)
L

Laymon Consulting, LLC


SLAB EDGE EDGE OF TOP OF
1'-0" O.C EW All rights reserved

EQ
GRADE BEAM SLAB CORNER BARS TO MATCH GRADE BEAM The arrangements
REINFORCING. EACH LEG TO BE 30" LONG. depicted herein are the

4 12"
PLACE ON TOP & BOTTOM OF GRADE BEAM. sole property of Laymon
Consulting, LLC and may
not be reproduced in any

EQ
20. WHEN A GRADE BEAM JOGS WITHIN THE 30" OF THE CORNER REINFORCING, CONTINUE THE REINFORCING AROUND THE JOG AND EXTEND 30"
form without written
PAST THE LAST TURN AS SHOWN BELOW.
#3 REBAR permission.
30"
CHAIRS @ 48" O.C. VAPOR RETARDER
K

(MAX) MAY BE
PLASTIC, METAL,
PREPARED SUBGRADE

< 30"
OR BRICK

5. SOME PORTIONS OF THE FOUNDATION MAY REQUIRE FOOTINGS TO SUPPORT POINT LOADS ON THE FOUNDATION OR HOLDOWNS OR ANCHORS
REQUIRING THICKER CONCRETE FOR UPLIFT PURPOSES. FOOTINGS ARE SHOWN AS BELOW AND ARE LABELED WITH "F#". 11. GRADE BEAM AND FOOTING SIZES AND REINFORCING ARE SHOWN IN THE FOUNDATION SIZE SCHEDULE BELOW.

FOUNDATION SIZE SCHEDULE


30"
J

CONVENTIONALLY GRADE BEAMS


REINFORCING 21. PLUMBING AND ELECTRICAL CONDUIT SHALL NOT BE PLACED WITHIN AND PARALLEL TO THE GRADE BEAMS. THEY SHALL CROSS THE GRADE
MARK WIDTH DEPTH
TOP BOTTOM TIES BEAMS AT 90° ANGLES AS BEST AS POSSIBLE.
RB-1 12" 24" (2)#5 (2)#5 #3@12"
F-1 RB-2 18" 24" (2)#5 (2)#5 #3@12" 22. THERE MAY BE PENETRATIONS HORIZONTALLY THROUGH THE GRADE BEAMS FROM PLUMBING AND ELECTRICAL CONDUITS. PENETRATIONS ARE
ALLOWED PROVIDED THE PENETRATING MEMBER IS NO LARGER THAN 13 THE GRADE BEAM DEPTH, IS PLACED WITHIN THE MIDDLE HALF OF THE
GRADE BEAM, AND WITH MULTIPLE PENETRATIONS IS SPACED NO CLOSER THAN 2x THE LARGER DIAMETER MEMBER. IT IS ACCEPTABLE FOR THE
FOOTING ADDITIONAL TIES ADDED TO EACH SIDE OF THE PENETRATION TO BE INVERTED U-SHAPED.
FOOTINGS
6. THERE ARE OTHER PORTIONS OF THE FOUNDATION THAT DON'T NEED A FULL GRADE BEAM BUT NEED SOMETHING THICKER THAN THE SLAB REINFORCING ADD #5 T&B OF PENETRATION AND EACH FACE
MARK WIDTH LENGTH DEPTH OF GRADE BEAM (4 TOTAL) EXTENDED 30" GRADE BEAM REINFORCING
THICKNESS TO SUPPORT THE LOAD, HELP WITH SLAB DROP TRANSITIONS, OR FOR ANCHOR BOLTS SUPPORT IN SHEARWALLS. THESE THICKENED TOP BOTTOM
SLABS (OR SOMETIMES REFERRED TO AS "SHOVEL BEAMS") ARE 1'-0" THICK REINFORCED WITH (2) #5 REBAR. THE WIDTH OF THE THICKENED BEYOND THE PENETRATION
H

F-1 2'-6" 6'-6" 12" - #5@12" E.W.


SLABS ARE TYPICALLY 1'-0" WIDE, BUT CAN VARY. ANY VARIATION IN WIDTH OTHER THAN 1'-0" WILL BE CALLED OUT ON THE FOUNDATION PLANS.

GRADE BEAM DEPTH


H/4
H/2

Gandy Residence

Lubbock, TX 79413
H/4

3404 47th St.


G

ALLOWABLE PENETRATION ZONE ADDL (3) TIES (U-SHAPED) @3" O.C. ON


EACH SIDE OF THE PENETRATION
THICKENED SLAB

H/3 MAX DIAMETER


7. GRADE BEAMS LABELED WITH "RB-#" ARE CONVENTIONALLY REINFORCED GRADE BEAMS WITH REBAR IN THE TOP AND BOTTOM OF THE GRADE
BEAM AND TIES OR STIRRUPS SPACED ALONG THE LENGTH OF THE GRADE BEAM.
23. FOR OCCASIONS WHERE THE PENETRATION ENTERS THE LOWER H/4 ZONE SHOWN ABOVE AND INTERFERES WITH THE BOTTOM GRADE BEAM
REINFORCING, THE GRADE BEAM WILL NEED TO BE THICKENED IN THAT AREA TO ALLOW FOR ADDITIONAL REINFORCING AND CONCRETE AS
SHOWN BELOW.

CONVENTIONALLY
STEP 2: VAPOR RETARDER INSTALLATION ADD #5 T&B OF PENETRATION AND EACH FACE
F

RB-1 RB-1 OF GRADE BEAM (4 TOTAL) EXTENDED 48db GRADE BEAM REINFORCING
REINFORCED GRADE BEAM
12. THIS IS NOT TO BE CONSIDERED AN EXHAUSTIVE LIST OF EVERYTHING REQUIRED TO INSTALL THE VAPOR RETARDER. THIS IS A LIST PROVIDED BEYOND THE PENETRATION
CALLOUT. DIFFERENT
RB-1

RB-2

RB-1

BY THE STRUCTURAL ENGINEER OF RECORD FOR INSTALLATION ISSUES THAT CAN POTENTIALLY AFFECT THE STRUCTURAL INTEGRITY OF THE
NUMBER SIGNIFY
FOUNDATION. THE GENERAL CONTRACTOR AND THE SUBCONTRACTORS ARE SOLELY RESPONSIBLE FOR THE PROPER INSTALLATION OF THE

GRADE BEAM DEPTH


H/4
DIFFERENT SIZES AND/OR
VAPOR RETARDER.
REINFORCING.
13. IF A LEVELING BASE IS USED, THE VAPOR RETARDER SHALL BE PLACED ON TOP OF THE LEVELING BASE MATERIAL.

H/2

H
14. WHEN REQUIRED, THE VAPOR RETARDER SHOULD BE LAPPED TO PROVIDE A CONTINUOUS SHEET UNDER THE ENTIRE FOUNDATION. THE JOISTS
SHALL BE TAPED COMPLETELY.

H/4
15. CARE MUST BE TAKEN TO ENSURE THAT THE VAPOR RETARDER MATERIAL DOES NOT BECOME ENTANGLED OR HUNG UP IN THE REINFORCEMENT,
E

CAUSING VOIDS, JOINTS, OR THIN SPOTS TO OCCUR DURING CONCRETE PLACEMENT.

16. THE VAPOR RETARDER SHOULD BE SECURED TO THE SIDES OF THE GRADE BEAMS AND CUT ALONG THE BOTTOM OF THE GRADE BEAM. CUTTING
8. IN SOME PARTS OF THE COUNTRY FROST DEPTH PROTECTION IS REQUIRED. FROST BEAMS ARE GRADE BEAMS OR CONTINUOUS WALL FOOTINGS ALONG THE BOTTOM OF THE GRADE BEAM PREVENTS "BRIDGING" FROM OCCURRING.

6" MIN
THAT EXTEND DOWN TO THE FROST LINE REQUIRED BY THE LOCAL REGION TO KEEP MOISTURE AND FROST FROM MIGRATING UNDER THE ADDL (3) TIES (U-SHAPED)
FOUNDATION AND CAUSING IT TO HEAVE. THEY SHALL ALWAYS BE AROUND THE PERIMETER OF THE FOUNDATION AS WELL AS UNDER AREAS 17. IT IS NOT NECESSARY FOR THE VAPOR RETARDER BE EXTENDED OUTSIDE THE FOUNDATION PERIMETER. @3" O.C. ON EACH SIDE
SEPARATING CONDITIONED AND UNCONDITIONED AIR WITHIN THE BUILDING. FROST BEAM LOCATIONS ARE SHOWN ON THE FOUNDATION PLAN OF THE PENETRATION
WITH A HATCHED AREA. ALLOWABLE PENETRATION ZONE
PIPE Ø + 8" PIPE Ø + 8"
VAPOR RETARDER SECURE TO THE
SIDES WITH NAILS Issued For Date
24. SLAB REINFORCING SHALL BE PLACED ON CHAIRS OR BRICKS PRIOR TO PLACEMENT OF CONCRETE. PULLING REBAR UP INTO THE CONCRETE AS Construction 10/24/2022
D

FROST BEAM THE CONCRETE IS BEING PLACED IS NOT ACCEPTABLE AND THE FOUNDATION WILL BE REJECTED. ALL DAMAGED CHAIRS SHALL BE REPLACED
PRIOR TO THE PLACEMENT OF CONCRETE.

25. ADDITIONAL SLAB REINFORCING NOT SHOWN ON THE PLANS WILL BE REQUIRED AT THE CORNERS AND AT OPENINGS LARGER THAN 12".

SLAB REINFORCING
ROUND OR

48db TYP
CORNER BAR, 24"x24"
TO MATCH SLAB RECTANGULAR
EXTERIOR CUT DOWN THE REINFORCING SIZE OPENING
GRADE BEAM MIDDLE TO AVOID
BRIDGING NO BRIDGING
C

OPENING
> 1'-0"
9. ADDITIONAL REINFORCING MUST BE PLACED AT RE-ENTRANT CORNERS TO MITIGATE CRACKING AT THOSE CORNERS DUE TO CONCRETE
SHRINKAGE. RE-ENTRANT CORNERS OCCUR AROUND THE PERIMETER OF THE FOUNDATION, AT CONSTRUCTION AND CONTROL JOISTS WITH SLAB EDGE
STEP 3: REINFORCING STEEL INSTALLATION
JOGS IN THEM, AND AT FOUNDATION DROPS AND STEPS. REINFORCING IS (2) #4 x 5'-0" LONG REBAR PLACED AT A 45° ANGLE TO THE CORNER,
PLACED MID-DEPTH IN THE SLAB, AND SPACED AS SHOWN: 18. THIS IS NOT TO BE CONSIDERED AN EXHAUSTIVE LIST OF EVERYTHING REQUIRED TO INSTALL THE REINFORCING STEEL. THIS IS A LIST PROVIDED
BY THE STRUCTURAL ENGINEER OF RECORD FOR INSTALLATION ISSUES AND REQUIREMENTS THAT CAN POTENTIALLY AFFECT THE STRUCTURAL 2" CLR
INTEGRITY OF THE FOUNDATION. THE GENERAL CONTRACTOR AND THE SUBCONTRACTORS ARE SOLELY RESPONSIBLE FOR THE PROPER (TYP)
48db TYP
INSTALLATION OF THE REINFORCING STEEL. EXTERIOR SLAB EDGE CORNER REINFORCING

CORNER
B

DIAGONALS ARE NOTE:


LC Project No.: 1803.011
RE-ENTRANT ALL OPENING REINFORCEMENT TO
3"

4'-0" LONG
CORNER MATCH SLAB REINFORCING SIZE.
3"

Scale: None

OPENING REINFORCEMENT IN SLAB-ON -GRADE


Conv. Found.
Information
A

RE-ENTRANT STEEL

S010
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

FRAMING INFORMATION SHEET 6. COLUMNS AND POSTS SHALL BE USED UNDER THE ENDS OF ALL HEADERS, BEAMS, AND GIRDER TRUSSES. AT A MINIMUM, A (2)2x STUD PACK
SHALL BE USED.

7. UNLESS NOTED OTHERWISE, ALL HEADERS, BEAMS, AND GIRDER TRUSSES SHALL BE SUPPORTED WITH A SP224 OR SP226, DEPENDING ON THE
STEP 1: HOW TO READ THE PLANS
M

WALL THICKNESS SUPPORTING THE HEADER, BEAM, OR GIRDER TRUSS. 10. FOR MULTIFAMILY PROJECTS, THE INDIVIDUAL APARTMENT UNITS TYPICALLY STACK ONE ON TOP OF THE OTHER. THE OVERALL BUILDING FLOOR
PLANS WILL SHOW A UNIT STACK CONDITION INDICATING THE UNIT TYPE ON THE FLOOR LEVEL BEING FRAMED OVER THE UNIT TYPE ON THE
1. MATERIAL SPECIFICATIONS FOR LUMBER GRADE AND SPECIES, FASTENERS, DECKING AND SHEATHING, AND WOOD SHRINKAGE CONCERNS CAN 8. COLUMN/POST STACKING CONDITION WILL BE CALLED OUT ON THE PLAN AND WILL INDICATE THE FLOOR LEVEL AND COLUMN/POST SIZE FLOOR BELOW (SHOWN IN THE BACKGROUND) AND WHERE THAT FRAMING PLAN CAN BE LOCATED WITHIN THE DRAWING SET.
BE FOUND IN THE SPECIFICATION SECTION AT THE BEGINNING OF THIS SET. REQUIRED AS SHOWN IN THE FRAMING PLAN EXAMPLE TO THE LEFT. 5575 Stousland Rd.
UNIT ON THE FLOOR LEVEL BEING FRAMED College Station, TX 77845
2. FRAMING PLANS SHOW THE FRAMING FOR THE FLOOR/ROOF LEVEL CALLED OUT BELOW EACH PLAN. THE BACKGROUND SHOWN FOR THOSE 9. COLUMNS AND POSTS ARE CALLED OUT AS TWO LETTERS FOLLOWED BY A SERIES OF NUMBERS. THE TWO LETTERS HELP TO INDICATE THE TYPE
PLANS IS FOR THE WALLS BELOW SO THAT YOU MAY KNOW WHICH WALLS ARE TO BE USED TO SUPPORT THE TRUSSES/JOISTS. (CAUTION: DO XX UNIT ON THE FLOOR LEVEL BELOW (832) 423-2977
OF COLUMN: "SP" INDICATES A STUD PACK WITH CONVENTIONAL LUMBER STUDS, "WP" INDICATES A SOLID WOOD POST, AND "EP" AND
NOT CONFUSED THIS WITH THE SHEARWALL PLANS WHICH SHOW THE BACKGROUND OF THE FLOOR IN WHICH THOSE WALLS ARE CONSTRUCTED. XX (ON THE BACKGROUND PLAN) www.laymonconsulting.com
ENGINEERED POST MADE OF STRUCTURAL COMPOSITE LUMBER. THE NUMBERS ARE USED TO INDICATE AS SIZE. FOR EXAMPLE, 224 IS A (2) 2x4,
SEE SHEETS S030 AND S031 FOR SHEARWALL INFORMATION.) BEARING WALLS, HEADERS, BEAMS, AND TRUSSES/JOISTS ARE DEPICTED AS 410 IS A 3 12" X 9 1 4", ETC. THE FULL LIST AND A DESCRIPTION OF EACH MARK IS LISTED BELOW. X/Sxxx
FOLLOWS: LOCATION IN THE DRAWING SET TX Firm # F-19205
THE FRAMING PLAN CAN BE FOUND
HEADER SIZE. SEE
BEARING WALL NOTE 4 BELOW. HEADER
COLUMN SCHEDULE © 2022
L

326 326 11. ROOF TRUSSES LIKE TO BE FRAMED IN THE DIRECTION OF THE SLOPE. HOWEVER, THERE ARE AREAS ON ROOFS WHERE THAT IS NOT ALWAYS Laymon Consulting, LLC
CONVENTIONAL LUMBER POSSIBLE. THOSE AREAS ARE TYPICALLY CALLED "OVERFRAME" AREAS AND ARE SHOWN ON THE PLANS WITH A DOTTED HATCHING. WE HAVE All rights reserved
MARK SIZE MARK SIZE DONE OUR BEST TO HIGHLIGHT THESE AREAS TO HELP THE TRUSS MANUFACTURER KNOW WHERE THESE OCCUR. THE TRUSS MANUFACTURER The arrangements
SP224 (2) 2x4 STUD PACK SP424 (4) 2x4 STUD PACK WILL HAVE THE OPTION TO EITHER BUILD THESE AREAS INTO THE MAIN TRUSSES SHOWN ON THE PLANS OR TO CROSS FRAME ON TOP OF THE depicted herein are the
SP226 (2) 2x6 STUD PACK SP426 (4) 2x6 STUD PACK MAIN TRUSSES WITH CAP OR OVERFRAME TRUSSES. sole property of Laymon
SP324 (3) 2x4 STUD PACK SP524 (5) 2x4 STUD PACK Consulting, LLC and may
TRUSS/JOIST SP326 (3) 2x6 STUD PACK SP526 (5) 2x6 STUD PACK OVERFRAME AREA not be reproduced in any
form without written
permission.
COLUMN/POST BEARING WALL SOLID LUMBER
CALLOUT MARK SIZE MARK SIZE
K

WP44 4x4 SYP #2 WP66 6x6 SYP #2

.
24" O.C
2ND: SP324 TRUSS DESIGNATION WP46 4x6 SYP #2 WP88 8x8 SYP #2
1ST: SP424 AND SPACING
FT-1 @

BACKGROUND OF ENGINEERED LUMBER


GABLE SLOPE GABLE SLOPE
THE FLOOR BELOW MARK SIZE MARK SIZE
THE FRAMING 1 1
EP44 3 2" x 3 2" PSL 1 1
EP66 5 4" x 5 4" PSL
BEAM SIZE. SEE EP46 3 12" x 5 1 4" PSL EP67 5 1 4" x 7" PSL
E410

NOTE 4 BELOW. EP47 3 12" x 7" PSL EP77 7" x 7" PSL

2210 BEAM SIZE. SEE


FLUSH BEAM NOTE 4 BELOW.
J

JACK STUDS & KING POSTS


DROP BEAM RE: S021 FOR
OPENING FLOOR LEVEL NUMBER OF NUMBER OF REQ'D BLOCKING

SIZE FROM TOP JACK STUDS KING POSTS


NON-LOAD BEARING WALLS KING POSTS
REMAIN GRAY AND ARE NOT TOP 1 1 (FULL HEIGHT)
SECOND FLOOR FRAMING PLAN

MAIN ROOF SLOPE


HATCHED. FOR THIS
1 1/4" = 1'-0" EXAMPLE, FIRST FLOOR 3 FT
2ND DOWN
3RD DOWN
1
1
1
1
WALLS ARE SHOWN. JACK STUDS
4TH DOWN 1 2
(UNDER HEADER/BEAM)
FLOOR LEVEL FOR THE FRAMING SHOWN. IN THIS EXAMPLE, SECOND FLOOR. TOP 1 1
OPENING WIDTH
2ND DOWN 2 1
H

6 FT
3RD DOWN 2 1
4TH DOWN 2 2
3. FLUSH BEAMS ARE BEAMS THAT ARE ABOVE OR SIT ON TOP OF THE BEARING PLATES. DROP BEAMS ARE BEAMS THAT ARE FRAMED BELOW THE 4" O.C.
BEARING PLATE BUT NOT OVER A DOOR OR WINDOW. HEADERS ARE ALSO FRAMED BELOW THE PLATE BUT ARE SPECIFICALLY OVER A DOOR OR TOP 1 1 RT-1 @ 2
A WINDOW. 2ND DOWN 1 1
8 FT
3RD DOWN 2 2

Gandy Residence
4. BEAMS ARE HEADERS WILL BE MARKED ON PLAN WITH A 3- OR 4-DIGIT NUMBER WHEN THE BEAM IS TO BE CONSTRUCTED WITH CONVENTIONAL TOP
4TH DOWN 2 2
LUMBER OR A 2-, 3-, OR 4-DIGIT NUMBER PRECEDED WITH THE LETTER "E" WHEN THE BEAM IS TO BE CONSTRUCTED WITH AND ENGINEERED 2ND DOWN
TOP 2 1

Lubbock, TX 79413
LUMBER SUCH AS PARALLEL STRAND LUMBER (PSL) AND LAMINATED VENEER LUMBER (LVL). THE BEAM/HEADER SCHEDULE IS SHOWN BELOW.
2ND DOWN 2 2 3RD DOWN
10 FT
3RD DOWN 2 2 4TH DOWN

3404 47th St.


4TH DOWN 2 3
BEAM/HEADER SCHEDULE
G

CONVENTIONAL LUMBER 10. THE TRUSS PLACEMENT SHOWN ON THE PLAN IS ONLY APPROXIMATE AND IS SOLELY INTENDED TO SHOW THE TRUSS SPAN DIRECTION, SPACING
MARK SIZE MARK SIZE REQUIREMENTS, AND SUPPORT LOCATIONS. THE ACTUAL TRUSS DESIGN AND PLACEMENT REQUIREMENTS AND DIMENSIONS ARE SHOWN ON
226 (2) 2x6 426 (4) 2x6 THE TRUSS MANUFACTURER'S DRAWINGS.
228 (2) 2x8 428 (4) 2x8
11. TRUSSES ARE LABELED BASED ON THEIR LOCATION, SIZES, AND LOADING REQUIREMENTS. TRUSS LABELING IS A WAY FOR THE PLANS TO HELP
2210 (2) 2x10 4210 (4) 2x10
THE TRUSS MANUFACTURER AND THE GENERAL CONTRACTOR KNOW WHERE TRUSS LOADING OR DEPTH REQUIREMENTS CHANGE. TRUSSES
2212 (2) 2x12 4212 (4) 2x12 ARE DESIGNATED AS "_T-#" WITH THE "_T" INDICATING A GENERAL LOCATION AND THE "#" INDICATING A DIFFERENT TYPE OF LOADING OR DEPTH
326 (3) 2x6 526 (5) 2x6 FOR THAT LOCATION.
328 (3) 2x8 528 (5) 2x8 A. BT = BALCONY TRUSS STEP 2: FRAMING REQUIREMENTS FOR ROOF AND FLOOR TRUSSES
3210 (3) 2x10 5210 (5) 2x10 B. CT = CORRIDOR TRUSS
F

C. DT = DRAG TRUSS (SEE SHEETS S009 AND S010) 12. ROOF TRUSSES SHALL BE PLACED AS SHOWN AND DIMENSIONED ON THE APPROVED TRUSS MANUFACTURER DRAWINGS.
3212 (3) 2x12 5212 (5) 2x12
D. FT = FLOOR TRUSS
ENGINEERED LUMBER E. GT = GIRDER TRUSS 13. ALL ROOF TRUSSES SHALL BE ATTACHED TO A WALL, BEAM, OR GIRDER TRUSS AT ALL BEARING POINTS WITH A CLIP OR HANGER CAPABLE OF
MARK SIZE MARK SIZE F. RT = ROOF TRUSS WITHSTANDING THE UPLIFT LOAD SHOWN ON EACH TRUSS PROFILE SHEET PROVIDED BY THE TRUSS MANUFACTURER. THE TRUSS
E46 E612 5 1 4" x 11 7 8" PSL/LVL MANUFACTURER DRAWINGS APPROVED BY LAYMON CONSULTING WILL TYPICALLY SHOW THE CLIP ATTACHMENT REQUIREMENTS. CONTACT
E48 3 12" x 7 1 4" PSL/LVL E614 5 1 4" x 14" PSL/LVL EXAMPLE 1 LAYMON CONSULTING IF YOU NEED HELP WITH THIS INFORMATION. AT A MINIMUM, ALL ROOF TRUSSES SHALL BE ATTACHED WITH A SIMPSON
1 1 FT-1 IS A 18" DEEP FLOOR TRUSS WITH A 40 PSF LIVE LOAD ON THE TOP CHORD H2.5A CLIP AT ALL BEARING LOCATIONS.
E410 3 2" x 9 4" PSL/LVL E616 5 1 4" x 16" PSL/LVL
FT-2 IS A 24" DEEP FLOOR TRUSS WITH A 40 PSF LIVE LOAD ON THE TOP CHORD
E411 3 12" x 11 1 4" PSL/LVL E618 5 1 4" x 18" PSL/LVL FT-3 IS A 18" DEEP FLOOR TRUSS WITH A 100 PSF LIVE LOAD ON THE TOP CHORD
E412 1 7
3 2" x 11 8" PSL/LVL E78 7" x 7 1 4" PSL/LVL C.
" O.
E414 1
3 2" x 14" PSL/LVL E710 7" x 9 1 4" PSL/LVL EXAMPLE 2 8'-0
E416 3 12" x 16" PSL/LVL E711 7" x 11 14" PSL/LVL CT-1 IS A 17 1 4" DEEP CORRIDOR TRUSS WITH A 100 PSF LIVE LOAD ON THE TOP CHORD
E

1 CT-2 IS A 15" DEEP CORRIDOR TRUSS WITH A 100 PSF LIVE LOAD ON THE TOP CHORD
E418 3 2" x 18" PSL/LVL E712 7" x 11 7 8" PSL/LVL
1 1
E66 5 4" x 5 2" PSL/LVL E714 7" x 14" PSL/LVL 8. THE TRUSSES ARE TO BE DESIGNED WITH THE LOADING SHOWN ON THE PLANS. THE DESIGN LOADS FOR THE PROJECT, SUCH AS WIND SPEED, 8'-0" O.C.
1 1
E68 5 4" x 7 4" PSL/LVL E716 7" x 16" PSL/LVL RISK CATEGORY, AND SNOW LOADS ARE SHOWN ON THE SPECIFICATIONS SHEETS UNDER THE "DESIGN LOADS" SPECIFICATION. THE DEAD AND
E610 5 1 4" x 9 1 4" PSL/LVL E718 7" x 18" PSL/LVL LIVE LOAD REQUIREMENTS FOR THIS SPECIFIC PROJECT FOR THE TOP AND BOTTOM CHORDS OF EACH TRUSS TYPE ARE SHOWN IN THE TRUSS
E611 5 1 4" x 11 1 4" PSL/LVL LOADING SCHEDULE BELOW.
LINE LINE LINE
PLATE PLATE PLATE

5. BEARING WALL CONSTRUCTION FOR THIS SPECIFIC PROJECT CAN BE FOUND IN THE BEARING WALL SCHEDULE BELOW.
A. ALL EXTERIOR WALLS SHALL BE CONSIDERED LOAD BEARING, EVEN IF NOT SHOWN AS HATCHED ON THE FRAMING PLANS.
B. PARTY WALLS ARE USED IN MULTIFAMILY CONSTRUCTION AND ARE THOSE WALLS THAT SEPARATE TWO APARTMENT UNITS AND
TRUSS LOADING SCHEDULE SIMPSON H2.5A SIMPSON H2.5A Issued For Date
(OR AS SHOWN ON APPROVED (OR AS SHOWN ON APPROVED
CONTAIN AN AIRSPACE BETWEEN THE WALLS. TOP CHORD BOTTOM CHORD Construction 10/24/2022
MARK DEPTH TRUSS MANUFACTURER DRAWINGS) TRUSS MANUFACTURER DRAWINGS)
D

i. AN EXCEPTION TO THIS ARE PARTY WALLS THAT SHARE A SILL PLATE AND BEARING PLATE WITH NARROWER STAGGERED STUDS DL LL DL LL
BETWEEN THE PLATES.
FT-1 18" 20 PSF 40 PSF 5 PSF 0 PSF
C. CORRIDOR WALLS ARE ANY WALLS THAT ARE SHARED BY AND SEPARATE THE APARTMENT UNIT AND THE CORRIDOR/BREEZEWAY. EXTERIOR BEARING POINT INTERIOR BEARING POINT INTERIOR BEARING POINT
D. INTERIOR WALLS ARE ALL LOAD BEARING WALLS CONTAINED WITHIN THE APARTMENT UNIT. RT-1 VARIES 20 PSF 20 PSF 5 PSF 0 PSF

NOTES: 14. INSTALL STRONGBACKS ACROSS ROOF TRUSS WEBS AND CHORDS AS DEPICTED ON THE TRUSS MANUFACTURER DRAWINGS. THIS IS NEEDED TO
1. DL = DEAD LOAD; LL = LIVE LOAD ENSURE THE TRUSSES AND TRUSS MEMBERS DO NOT BUCKLE AND FAIL.

BEARING WALL SCHEDULE 2. REFER TO MEP DRAWINGS FOR MECHANICAL UNIT 15. PROVIDE TEMPORARY BRACING ACROSS THE TOP AND BOTTOM CHORDS IN THE FORM OF 2x4 PLANKS RUNNING PERPENDICULAR AND ATTACHED
LOCATIONS AND LOADING. TO THE TOP AND BOTTOM CHORDS AT 8'-0" ON CENTER UNTIL THE ROOF DECKING AND THE CEILING MATERIAL HAVE BEEN ATTACHED. SEE THE
DETAIL ABOVE FOR A GRAPHICAL DEPICTION.
GANDY RESIDENCE 3. REFER TO MEP DRAWINGS FOR ANY CHASES
REQUIRED FOR DUCT WORK OR PLUMBING. 16. INSTALL STRONGBACK ACROSS FLOOR TRUSS BOTTOM CHORDS AT NO MORE THAN 10'-0" INTERVALS. STRANGBACK LAP SPLICES SHALL BE 4'-0"
C

FLOOR LOCATION SIZE QTY. & SPA. BLOCKING IN LENGTH. SOME STRONGBACK INSTALLATION OPTIONS ARE SHOWN BELOW. OTHER OPTIONS CAN BE APPROVED BY LAYMON CONSULTING
EXTERIOR 2x6 (1) @ 16" o.c. MID 4. REFER TO ARCHITECTURAL DRAWINGS FOR ANY EITHER THROUGH AN RFI OR DURING A FIELD VISIT.
1st 2x4 (1) @ 12" o.c. 1
3 PT.
APPURTENANCES HANGING FROM TRUSSES.
INTERIOR
2x6 (1) @ 16" o.c. MID
5. SEE FRAMING PLANS FOR ANY ADDITIONAL LINE
LOADS OR POINT LOADS SHOWN ON THE PLANS
TO BE SUPPORTED BY THE TRUSSES.
B

2x VERTICAL ATTACHED
2x STRONGBACK WITH (2) 8D COMMON 2x STRONGBACK
ATTACHED WITH (2) 8d NAILS AT EACH END ATTACHED WITH (2) 8d
COMMON NAILS 2x STRONGBACK COMMON NAILS LC Project No.: 1803.011
ATTACHED WITH (2) 8d
COMMON NAILS None
Scale:
9. THERE ARE SOME AREAS THAT MAY REQUIRE THE TRUSSES TO CARRY BEARING WALL LOADS FROM ABOVE. THOSE AREAS ARE SHOWN ON THE
FRAMING PLANS WITH A DASHED LINE ACROSS THE TRUSSES AS WELL AS THE DEAD AND LIVE LINE LOADS ON THOSE TRUSSES. 17. BROKEN OR MIS-INSTALLED TRUSSES SHALL BE REPAIRED IN ACCORDANCE WITH THE TRUSS MANUFACTURER'S REQUIREMENTS. IT IS
RECOMMENDED THAT A COPY OF THE REQUIRED TRUSS REPAIR BE ATTACHED TO THE REPAIRED TRUSS FOR EASY ACCESS TO ANY CITY OR
ENGINEERING INSPECTOR. Framing
240 PLF DL; 400 PLF LL
18. SEE THE SHEARWALL INSTRUCTION SHEETS FOR ADDITIONAL BRACING REQUIREMENTS IN THE TRUSS CAVITIES OVER THE SHEARWALLS. Information
A

S020
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
STEP 3: FRAMING REQUIREMENTS FOR WALLS 27. UNDER NO CIRCUMSTANCE SHOULD ADDITIONAL 2x BLOCKING BE USED TO "PAD UP" TO THE FLOOR DECKING. THIS CAUSES A SUBSTANTIAL 30. HEADERS ARE INSTALLED DIRECTLY ABOVE THE DOOR OR WINDOW OPENING WITH CRIPPLE STUDS PLACED BETWEEN THE BEARING PLATES AND
AMOUNT OF ADDITIONAL WOOD SHRINKAGE THAT WILL NOT BE ACCOUNTED FOR. THE DETAIL BELOW SHALL NOT BE USED. THE HEADER. CRIPPLE STUDS SHOULD BE THE SAME SIZE AND SPACING AS THE STANDARD STUDS WITHIN THE WALL ON EITHER SIDE OF THE
19. STUDS SHALL BE SIZED AND SPACED AS SHOWN IN THE "BEARING WALL SCHEDULE" ON THIS SHEET. THE STUDS SHALL HAVE A SINGLE SILL/SOLE OPENING. VERTICAL BLOCKING SHALL BE PLACED IN THE FLOOR CAVITY TO TRANSFER THE LOAD FROM THE HEADER POSTS ABOVE TO BELOW.
PLATE AND A DOUBLE BEARING PLATE, AT A MINIMUM. SOME DETAILS MAY REQUIRE ADDITIONAL PLATES. REFER TO THE DETAILS IN THE BACK THE VERTICAL BLOCKING SHALL MATCH THE SAME MATERIAL AND SIZE AS THE POSTS ABOVE.
M

OF THIS SET AS WELL AS THE ARCHITECTURAL DRAWINGS FOR ANY ADDITIONAL PLATING AND BLOCKING REQUIREMENTS.

SPACING, S
STUDS VERTICAL BLOCKING TO POST ABOVE 5575 Stousland Rd.
MATCH MATERIAL AND College Station, TX 77845
HORIZONTAL BLOCKING POST ABOVE SIZE OF POST ABOVE (832) 423-2977
USED TO "PAD UP" FLOOR DECKING
www.laymonconsulting.com
FLOOR DECKING
TX Firm # F-19205

FLOOR TRUSS
PLATE © 2022
L

FLOOR TRUSS Laymon Consulting, LLC


20. ANY STAGGERED STUD REQUIREMENTS WILL BE NOTED IN THE SCHEDULE AS "STAGGERED". STAGGERED STUD CONSTRUCTION SHALL BE AS
All rights reserved
FOLLOWS:
The arrangements
SPACING, S depicted herein are the
2x4 STUDS sole property of Laymon
Consulting, LLC and may
not be reproduced in any
BEARING PLATE form without written
FLUSH BEAM permission.
BEARING PLATE CRIPPLE
STUDS
POST BELOW
K

1
2 S SPACING, S
2x6 SILL PLATE

21. ALL WALL INTERSECTIONS AND CORNERS SHALL HAVE A MINIMUM OF THREE STUDS, IN ANY ORIENTATION, TYING THE INTERSECTING WALLS THIS DETAIL IS NOT TO BE USED.
TOGETHER. HEADER

22. SILL PLATES MUST BE ATTACHED TO THE FOUNDATION/DECKING WITH ANCHOR ATTACHMENTS AS SHOWN ON SHEET S031, NOTE 14.
POST BELOW
23. BEARING AND EXTERIOR WALL STUDS SHALL BE CAPPED WITH DOUBLE TOP PLATES INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT
INTERSECTIONS WITH OTHER PARTITIONS. END JOINTS IN DOUBLE TOP PLATES SHALL BE OFFSET NOT LESS THAN 48 INCHES AND SHALL BE 28. DROP BEAMS SHOULD BE PLACED DIRECTLY UNDER THE BEARING PLATES. THE BLOCKING IN THE FLOOR CAVITY TRANSFERRING THE LOAD HEADER CONSTRUCTION (LAYMON CONSULTING PREFERRED METHOD)
NAILED IN ACCORDANCE WITH THE "IBC FASTENING SCHEDULE" SHOWN ON THIS SHEET. FROM ABOVE TO THE DROP BEAM SHALL BE PLACED VERTICALLY AND SHALL MATCH THE MATERIAL AND SIZE OF THE POST ABOVE. IF NEEDED,
THE DROP BEAM CAN COME UP INTO ONE OF THE BEARING PLATES PROVIDED THE TOP BEARING PLATE IS ATTACHED TO THE DROP BEAM PER
THE "IBC FASTENING SCHEDULE" SHOWN ON THIS SHEET.
J

4'-0" OFFSET REQ. BY CODE AND ATTACHED


PER THE IBC FASTENING SCHEDULE
BOTTOM PLATE SHOWN ON THIS SHEET. STEP 5: FASTENING SCHEDULE
END JOINT TOP PLATE
VERTICAL BLOCKING TO POST ABOVE
END JOINT
MATCH MATERIAL AND
SIZE OF POST ABOVE
FLOOR DECKING
IBC FASTENING SCHEDULE
ROOF
DESCRIPTION OF BUILDING ELEMENT NUMBER AND TYPE OF FASTENER SPACING AND LOCATION
FLOOR TRUSS
STUD
H

3-8d COMMON (2 12" x 0.131");


1. BLOCKING BETWEEN TRUSSES TO TOP PLATE 3-10d BOX (3" x 0.128");
24. NONLOAD-BEARING WALLS AND PARTITIONS THAT ARE NOT PART OF A SHEARWALL MAY BE SPACED NOT MORE THAN 24" ON CENTER. EACH END, TOENAIL
OR OTHER FRAMING BELOW
3-3" x 0.131" NAILS
2-8d COMMON (2 12" x 0.131");
EACH END, TOENAIL
BLOCKING BETWEEN TRUSSES NOT AT A WALL 2-3" x 0.131" NAILS
STEP 4: FRAMING REQUIREMENTS FOR BEAMS, HEADERS, AND POSTS 2-16d COMMON (3 12" x 0.162");

Gandy Residence
TOP PLATE, TO TRUSS
END NAIL
3-3" x 0.131" NAILS
25. THERE ARE MANY OPTIONS IN HOW A BEAM OR HEADER IS FRAMED AND SUPPORTED. THE DETAILS AND OPTIONS SHOWN BELOW ARE THE

Lubbock, TX 79413
BEARING PLATE 16d COMMON (3 12" x 0.162") @ 6" O.C.;
PREFERENCES OF LAYMON CONSULTING. OTHER DETAILS MAY BE USED AND APPROVED FOR USE THROUGH THE RFI PROCESS OR THROUGH FLAT BLOCKING TO TRUSS AND WEB FILLER FACE NAIL
SITE VISITS. 3" x 0.131" NAILS @ 6" O.C.
3-10d COMMON (3" x 0.148");

3404 47th St.


DROP BEAM
G

26. FLUSH BEAMS SHOULD SIT DIRECTLY ON THE TOP BEARING WITH THE REQUIRED POST BELOW DIRECTLY UNDER THE BEAM END AND BEARING 3-16d BOX (3 12" x 0.135");
PLATE. ANY LOAD TRANSFERS COMING FROM ABOVE SHOULD OCCUR THROUGH VERTICAL BLOCKING BETWEEN THE FLOOR DECK AND THE POST BELOW 2. ROOF TRUSS TO TOP PLATE TOENAIL
4-10d BOX (3" x 0.128");
FLUSH BEAM AND LOCATED DIRECTLY UNDER THE POST ABOVE. THE BLOCKING SHOULD MATCH THE SAME MATERIAL AND SIZE AS THE POST
DROP BEAM BELOW DOUBLE BEARING PLATE (LAYMON CONSULTING PREFERRED METHOD) 4-3" x 0.131" NAILS
ABOVE. ALTERNATIVELY, THE FLUSH BEAM AND BLOCKING CAN REVERSE POSITIONS WITH THE FLUSH BEAM DIRECTLY UNDER THE FLOOR
DECKING. HOWEVER, THE BLOCKING BELOW THE FLUSH BEAM WILL NEED TO MATCH THE POST BELOW, NOT ABOVE.
WALL
DESCRIPTION OF BUILDING ELEMENT NUMBER AND TYPE OF FASTENER SPACING AND LOCATION

VERTICAL BLOCKING TO POST ABOVE


16d COMMON (3 12" x 0.162"); 24" O.C. FACE NAIL
MATCH POST MATERIAL VERTICAL BLOCKING TO POST ABOVE 3. STUD TO STUD (NOT AT BRACED WALL
AND SIZE ABOVE MATCH MATERIAL AND 10d BOX (3" x 0.128");
PANELS) 16" O.C. FACE NAIL
FLOOR DECKING SIZE OF POST ABOVE 3" x 0.131" NAILS
FLOOR DECKING 16d COMMON (3 12" x 0.162");
F

4. STUD TO STUD AND ABUTTING STUDS AT 16" O.C. FACE NAIL


INTERSECTING WALL CORNERS (NOT AT 16d BOX (3 12" x 0.135");
BRACED WALL PANELS) 12" O.C. FACE NAIL
3" x 0.131" NAILS
FLOOR TRUSS 16d COMMON (3 12" x 0.162"); 16" O.C. EACH EDGE, FACE NAIL
5. BUILT-UP HEADER (2x TO 2x HEADER)
FLOOR TRUSS 16d BOX (3 12" x 0.135"); 12" O.C. EACH EDGE, FACE NAIL
ATTACH TOP PLATE TO DROP BEAM PER 4-8d COMMON (2 12" x 0.131");
THE IBC FASTENING SCHEDULE FOR 6. CONTINUOUS HEADER TO STUD TOENAIL
4-10d BOX (3" x 0.128");
DOUBLE TOP PLATE 16d COMMON (3 12" x 0.162"); 16" O.C. FACE NAIL
7. TOP PLATE TO TOP PLATE 10d BOX (3" x 0.128");
12" O.C. FACE NAIL
3" x 0.131" NAILS
FLUSH BEAM 8-16d COMMON (3 12" x 0.162");
E

EACH SIDE OF END JOINT, FACE


BEARING PLATE 8. TOP PLATE TO TOP PLATE, AT END JOINTS 12-10d BOX (3" x 0.128"); NAIL (MIN. 24" LAP SPLICE
BEARING PLATE LENGTH EA. SIDE OF END JOINT)
POST BELOW 12-3" x 0.131" NAILS
9. BOTTOM PLATE TO DECKING OR FOUNDATION SEE SHEET S009 SEE SHEET S009
DROP BEAM
4-8d COMMON (2 12" x 0.131");
FLUSH BEAM LOW (LAYMON CONSULTING PREFERRED METHOD) 4-10d BOX (3" x 0.128"); TOENAIL
POST BELOW
4-3" x 0.131" NAILS
10. STUD TO TOP OR BOTTOM PLATE
DROP BEAM INTERFERING WITH ONE BEARING PLATE 2-16d COMMON (3 12" x 0.162");
3-10d BOX (3" x 0.128"); END NAIL Issued For Date
29. IF NECESSARY, A DROP BEAM CAN COME UP INTO BOTH BEARING PLATES. WHEN THIS HAPPENS, THE DROP BEAM MUST BE CONNECTED TO THE 3-3" x 0.131" NAILS
Construction 10/24/2022
2-16d COMMON (3 12" x 0.162");
D

TOP PLATES ON EITHER END OF THE DROP BEAM WITH STRAPS ON BOTH SIDES OF THE DROP BEAM AS SHOWN BELOW.
11. TOP PLATES, LAP AT CORNERS AND
3-10d BOX (3" x 0.128"); FACE NAIL
INTERSECTIONS
POST ABOVE 3-3" x 0.131" NAILS

FLOOR DECKING WALL


VERTICAL BLOCKING TO POST ABOVE
MATCH MATERIAL AND DESCRIPTION OF BUILDING ELEMENT NUMBER AND TYPE OF FASTENER SPACING AND LOCATION
SIZE OF POST ABOVE
FLOOR DECKING 3-8d COMMON (2 12" x 0.131");
12. TRUSS TO SILL, TOP PLATE, OR GIRDER 3-10d BOX (3" x 0.128"); TOENAIL
FLOOR TRUSS
VERTICAL BLOCKING TO 3-3" x 0.131" NAILS
MATCH POST MATERIAL 8d COMMON (2 12" x 0.131");
C

AND SIZE BELOW FLOOR TRUSS 13. RIM JOIST, BAND JOIST, OR BLOCKING TO TOP
10d BOX (3" x 0.128"); 6" O.C., TOENAIL
PLATE, SILL, OR OTHER FRAMING BELOW
3" x 0.131" NAILS
32" O.C., FACE NAIL AT TOP AND
20d COMMON (4" x 0.192")

CONNECTION
BOTTOM STAGGERED ON
FLUSH BEAM OPPOSITE SIDES

1
14. BUILT-UP GIRDERS AND BEAMS, 2x
BEARING PLATE 24" O.C., FACE NAIL AT TOP AND
LUMBER LAYERS 10d BOX (3" x 0.128");
BOTTOM STAGGERED ON
POST BELOW (MUST USE A CONNECTION 1 OPTION IN 3" x 0.131" NAILS
OPPOSITE SIDES
CONJUNCTION WITH A CONNECTION 2
BEARING PLATE

CONNECTION
OPTION) AND:
DROP BEAM 8d COMMON (2 12" x 0.131"); ENDS AND AT EACH SPLICE,
B

2
FLUSH BEAM HIGH 10d BOX (3" x 0.128"); FACE NAIL
3" x 0.131" NAILS
SIMPSON CS16x30" POST BELOW LC Project No.:
2-8d COMMON (2 12" x 0.131"); 1803.011
CENTERED ON BUTT JOINT
(4 TOTAL) DROP BEAM INTERFERING WITH BOTH BEARING PLATES 15. BRIDGING OR BLOCKING TO TRUSS 2-10d BOX (3" x 0.128"); EACH END, TOENAIL
2-3" x 0.131" NAILS Scale: None
NOTES:
1. THIS FASTENING SCHEDULE DOES NOT NEGATE THE USE OF UPLIFT CLIPS AND STRAPS. SEE PLANS AND DETAILS FOR
ANY ADDITIONAL UPLIFT REQUIREMENTS. Framing
Information
A

S021
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

SHEARWALL DRAWING INFORMATION SHEET 7. HOLDOWNS AND STRAPS CAN BE ADJUSTED WITHIN 12" FROM THE ENDS FOR SHEARWALLS 20' IN LENGTH AND GREATER AND WITHIN 6" FROM
THE ENDS FOR SHEARWALLS LESS THAN 20' IN LENGTH.
11. WHEN ROOF TRUSSES ARE PERPENDICULAR TO THE SHEARWALL, SUCH AS AT CORRIDORS AND EXTERIOR WALLS, BRACING AND BLOCKING ARE
USED TO TRANSFER THE SHEAR DOWN INTO THE SHEARWALLS.

8. HOLDOWNS AND STRAPS MUST BE ATTACHED TO THE SAME ENDS POSTS, AND THOSE END POSTS MUST STACK, THROUGHOUT THE HEIGHT OF 12. TO DETERMINE THE NUMBER OF BRACES REQUIRED OVER A SHEARWALL, USE THE CHART BELOW SHOWING THE LENGTH OF SHEARWALL THAT
STEP 1: HOW TO READ THE PLANS
M

THE SHEARWALL STACK. ONE BRACE CAN HANDLE. KEEP ADDING A BRACE UNTIL THE SUM OF THE LENGTHS IS GREATER THAN ACTUAL LENGTH OF THE SHEARWALL.

1. SHEARWALLS SHALL BE CONSTRUCTED AS SHOWN ON THE SHEARWALL PLANS WITHIN THIS SET OF DRAWINGS. EXAMPLE
SHEARWALL BELOW = GW13 (20)
5575 Stousland Rd.
2. SHEARWALL LOCATIONS ARE SHOWN WITH A SOLID DARK LINE ON THE SIDE OF THE STUD WALL THE SHEARWALL IS TO BE CONSTRUCTED. (1) BRACE FOR A GW13 WILL ACCOMODATE 10'-8" OF SHEARWALL. THIS IS NOT ENOUGH.
College Station, TX 77845
STEP 2: GETTING SHEAR FROM THE ROOF TO THE SHEARWALLS (2) BRACES WILL ACCOMODATE (10'-8") x 2 = 21'-4" OF SHEARWALL. THIS IS LONGER THAN THE 20' SHEARWALL.
THEREFORE, 2 BRACES WILL BE NEEDED OVER THIS SHEARWALL.
(832) 423-2977
SHEARWALL ON THIS SHEARWALL ON BOTH www.laymonconsulting.com
SIDE OF THE WALL ONLY SIDES OF THE WALL 9. FOR ROOF TRUSSES PARALLEL TO THE SHEARWALL, A DRAG TRUSS MUST BE PLACED DIRECTLY OVER THE SHEARWALL IN ORDER TO TRANSFER
13. THE BRACE ALSO MUST BE BELOW A CERTAIN ANGLE IN ORDER FOR IT TO BE EFFECTIVE. A BRACE THAT IS TOO VERTICAL WILL NOT WORK. THE
THE LOAD FROM THE ROOF DOWN TO THE SHEARWALL. THE FORCE THE DRAG TRUSS IS TO BE DESIGNED FOR CAN BE CALCULATED BY TX Firm # F-19205
SECOND CHART BELOW INDICATES THE NUMBER OF TRUSS BAYS THE BRACE MUST CROSS (ASSUMING TRUSSES ARE AT 24" O.C.) DEPENDING ON
MULTIPLYING THE SHEAR VALUE OF THE SHEARWALL BELOW THE DRAG TRUSS, WHICH IS GIVEN IN THE "SHEARWALL SCHEDULE" UNDER NOTE 4,
THE ROOF HEIGHT DIRECTLY OVER THE SHEARWALL.
BY THE LENGTH OF THE SHEARWALL, WHICH IS DEMONSTRATED IN NOTE 3.
© 2022
L

EXAMPLE (8)0.131" x 3" NAILS Laymon Consulting, LLC


GW11 (20) = 115 PLF x 20' = 2,300 LBS EACH SIDE (16 TOTAL) All rights reserved
The arrangements
10. THE DRAG TRUSSES MUST BE ATTACHED TO THE TOP PLATE OF THE SHEARWALLS WITH SIMPSON LTP4 AND A35 CLIPS. TO KNOW THE CORRECT TRUSS BAY SPAN LENGTH depicted herein are the
3. SHEARWALL MATERIAL, CONSTRUCTION, AND LENGTH ARE NOTED ON THE SHEARWALL PLANS WITH A SHEARWALL MARK: GW## FOR A GYPSUM 2x10 BLOCKING ACROSS 3
SPACING OFTHE CLIPS, LOOK ON THE SHEARWALL PLAN FOR THE TOP FLOOR AND DETERMINE THE SHEARWALL MARK DIRECTLY BELOW THE 0.113" x 2" NAILS @ 3" O.C.
SHEARWALL , PW## FOR AN OSB SHEARWALL, AND (##) INDICATED THE LENGTH IN FEET. 1 TRUSS BAY TRUSS BAYS AT THE TOP ONLY sole property of Laymon
DRAG TRUSS. THEN, USING THE DETAILS BELOW, DETERMINE THE CORRECT SCENARIO AND CLIP SPACING TO USE. TYPICALLY, THE TOP FLOOR ALONG BLOCKING
SHEARWALLS ARE THE LIGHTER SHEARWALLS, THUS ONLY THE LIGHTER SHEARWALLS ARE LISTED IN THE DETAILS BELOW. IF A DIFFERENT Consulting, LLC and may
SHEARWALL IS USED THAN IS LISTED BELOW, CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR THE CORRECT CLIPS AND SPACING TO USE. not be reproduced in any
SHEARWALL MARK PW21 (20) SHEARWALL LENGTH
form without written
permission.
GW11 (20) CLIP SPACING
SHEARWALL TYPE
K

LTP4 SPACING
BELOW
4. AFTER FINDING THE SHEARWALL MARK ON THE PLAN AND UNDERSTANDING WHICH SIDE OF THE WALL THE SHEATHING AND NAILING IS REQUIRED, GW11 4'-6" O.C.
REFER TO THE "SHEARWALL SCHEDULE" FOR THE SHEATHING AND FASTENING REQUIREMENTS. GW12 3'-6" O.C.
GW13 3'-0" O.C. PROVIDE MID-HEIGHT BLOCKING
(2)2x4 (WHEN H £ 12'-0")
PW21 1'-4" O.C. WITH (4) 0.131" x 3" NAIL ON

H
DRAG TRUSS (2)2x6 OTHERWISE
SHEARWALL SCHEDULE EACH SIDE WHEN H > 12'-0"

FASTNR FASTNR SPA. SHEAR


MARK THK. BLOCKING

TOP OF PLATE
TYPE EDGE FIELD VALUE

TOP OF PLATE
(8)0.131" x 3" NAILS
EACH SIDE (16 TOTAL)
EXTERIOR GYPSUM DRAG TRUSS
J

1
GW1 2" NO A 7" 7" 100 PLF
1
GW2 2" YES A 4" 4" 175 PLF
5 B, C, or D
GW3 8" YES 4" 7" 200 PLF SIMPSON LTP4 PER
SPACING NOTED
INTERIOR GYPSUM ABOVE ALONG ENTIRE
GW11 5 C, D, or E SHEARWALL LENGTH.
8" NO 7" 7" 115 PLF 2x10 BLOCKING
5 C, D, or E
GW12 8" NO 4" 4" 145 PLF
SIMPSON LTP4 PARTYWALL
5 C, D, or E
GW13 8" YES 4" 4" 175 PLF
BASE LAYER SPACED PER
5
8" YES C, D, or E 9" 9" SCHEDULE
GW14* 250 PLF SHEARWALL BELOW (2)SIMPSON LTP4 WITH
H

FACE LAYER A
5 SHEARWALL (2)SIMPSON A35 (OPPOSITE SIDE)
8" - F, G, or H 7" 7" -
AIRSPACE PER ARCH SHEATHING
SIDE
PLYWOOD/OSB
PW21 7
16" YES I 6" 12" 365 PLF DRAG TRUSSES OVER PARTY WALL SHEARWALLS
7
PW22 16" YES I 4" 12" 532 PLF

Gandy Residence
7
PW23 16" YES I 3" 12" 685 PLF
7
PW24 16" YES J 3" 12" 840 PLF

Lubbock, TX 79413
CLIP SPACING
FASTENERS: 2x10 BLOCKING
A. 0.120" x 1 3 4", 7 16" HEAD, DIAMOND-POINT, GALV. NAIL SHEARWALL TYPE

3404 47th St.


LTP4 SPACING
BELOW
G

B. 6d GALV. COOLER NAIL (0.092" x 1 7 8", 1 4" HEAD)


C. WALLBOARD NAIL (0.0915" x 1 7 9", 19 64" HEAD) GW11 4'-6" O.C.
D. 0.120" x 1 3 4", 3 8" HEAD, NAIL GW12 3'-6" O.C.
E. 6d COOLER NAIL (0.092" x 1 7 8", 14" HEAD) DIAGONAL BRACE
GW13 3'-0" O.C.
F. 8d COOLER NAIL (0.113" x 2 3 8", 0.281" HEAD) PW21 1'-4" O.C.
G. WALLBOARD NAIL (0.113" x 2 3 8", 3 8" HEAD) DRAG TRUSS
H. 0.120" x 2 3 8", 3 8" HEAD, NAIL
I. 8d COMMON or 8d BOX (GALV. ON EXTERIOR)
J. 10d COMMON or 10d BOX (GALV. ON EXTERIOR)

TOP OF PLATE
TOP OF PLATE
* GW14 IS (2) LAYERS OF 5 8" GYPSUM WALLBOARD.
DRAG TRUSS 2x10 BLOCKING
F

5. SHEARWALLS REQUIRE ANCHORAGE AT EACH END WITH EITHER A STRAP CONNECTING THE SHEARWALL ABOVE THE FLOOR CAVITY TO THE
SHEARWALL BELOW OR WITH A HOLDOWN CONNECTING THE SHEARWALL TO THE FOUNDATION. THE SHEARWALL STRAPS AND HOLDOWNS ARE SIMPSON LTP4 PER
SHOWN AT THE ENDS OF EACH WALL WITH THE FOLLOWING MARKS: S# FOR STRAPS AND HD# FOR HOLDOWNS. SPACING NOTED
ABOVE ALONG ENTIRE (2) SIMPSON A35
HOLDOWN CALLOUT AT STRAP CALLOUT AT THE SIMPSON LTP4 SHEARWALL LENGTH. (2) SIMPSON LTP4
THE END OF A SHEARWALL END OF A SHEARWALL SPACED PER
HD2 PW21 (20) S3 SCHEDULE NO SHEARWALL PARTYWALL
SHEATHING

GW11 (20) SHEARWALL


SHEATHING
E

SIDE
SECTION A
6. REFER TO THE "STRAP/HOLDOWN SCHEDULE" FOR CONSTRUCTION AND FASTENING REQUIREMENTS FOR THE NOTED STRAPS AND HOLDOWNS. DRAG TRUSS OVER INTERIOR WALL WITH SHEARWALL SHEATHING ON ONE SIDE ONLY

STRAP/HOLDOWN SCHEDULE NUMBER OF BRACES REQUIRED BRACE TRUSS BAY SPAN LENGTH
CLIP SPACING
SHEARWALL TYPE A35 & LTP4 SHEARWALL TYPE MAX. LENGTH PER TRUSS HEIGHT MIN. # OF TRUSS
STRAPS
4. STRAPS WILL BUCKLE IF ATTACHED AT BOTH ENDS
BELOW BRACE OVER SHEARWALL BAYS PER BRACE Issued For Date
PRIOR TO ALLOWING FOR WOOD SHRINKAGE AND BELOW SPACING
SIMPSON END/TOT. MIN. No. NAILS CONSTRUCTION SETTLEMENT TO OCCUR. GW11 4'-6" O.C. GW11 17'-4" 7'-0" 2 Construction 10/24/2022
MARK
D

PRODUCT LENGTH DF/SYP SPF/HF GW12 3'-6" O.C. GW12 13'-4" 10'-0" 3
S1 CS20 9"/42" (14) 0.131"x2.5" (16) 0.131"x2.5" 5. NUMBER OF NAILS SHOWN IS THE TOTAL NUMBER GW13 3'-0" O.C. GW13 10'-8" 14'-0" 4
S2 CS16 15"/54" (22) 0.131"x2.5" (26) 0.131"x2.5" OF NAILS FOR THE ENTIRE LENGTH OF THE STRAP. PW21 5'-4" 17'-0" 5
PW21 1'-4" O.C.
(30) 0.131"x2.5" (36) 0.131"x2.5" FOR THE NUMBER OF NAILS REQUIRED AT EACH DRAG TRUSS
S3 CS14 19"/62" 20'-0" 6
END, DIVIDE THE NUMBER SHOWN BY 2. THE LENGTHS SHOWN ABOVE ARE
S4 CMSTC16 25"/74" (50) 0.148"x2.5" (58) 0.148"x2.5"
FOR A SINGLE BRACE. IF THE THE NUMBER OF BAYS SHOWN
S5 CMST14 34"/92" (66) 0.148"x2.5" (76) 0.148"x2.5" 6. STRAPS S1, S2, AND S3 CAN BE ATTACHED TO THE SHEARWALL IS LONGER THAN THE ABOVE ARE A MINIMUM IN ORDER TO
S6 CNST12 44"/112" (86) 0.148"x2.5" (98) 0.148"x2.5" FACE OF A SINGLE STUD. STRAPS S4, S5, AND S6 LENGTH SHOWN, THAN ANOTHER
TOP OF PLATE

NOT EXCEED A MAXIMUM ANGLE OF


REQUIRE A DOUBLE STUD FOR ATTACHMENT. BRACE WILL BE REQUIRED PER THE BRACE TO THE PLATE LINE.
HOWEVER, ALL END POSTS SHALL BE THE SAME AS SIMPSON A35 DRAG TRUSS LENGTH SHOWN UNTIL THE
HOLDOWNS THESE NUMBERS MAY BE
IS REQUIRED FOR THE HOLDOWN IN THE SPACED PER SHEARWALL LENGTH IS ACHIEVED.
SIMPSON END WOOD ANCH ANCH DEP. INCREASED IF NEEDED.
MARK SHEARWALL STACK. SCHEDULE
PRODUCT POST FASTENER DIA. EDGE INT
C

(2)2x4 (8) SDS25212 1 SIMPSON LTP4 PER


HD1 DTT2Z 2" 5" 3" 7. DIFFERENT PRODUCTS AND MANUFACTURERS ARE
HD2 HDU2 (3)2x4 (6) SDS25212 5
8 " 6" 4" NOT ALLOWED WITHOUT APPROVAL FROM THE SPACING NOTED
HD3 HDU4 (3)2x4 (10) SDS25212 5 EOR. ABOVE ALONG ENTIRE
8" 9" 5"
SHEARWALL LENGTH.
HD4 HDU8 (3)2x4 (20) SDS25212 7 8" 13" 6"
HOLDOWNS: SIMPSON LTP4
(3)2x6 (30) SDS25212 1" 15.5" 6.5" 1. FASTENERS SHOWN ARE SUPPLIED BY SIMPSON SPACED PER PARTYWALL
HD5 HDU11
(3)2x8 (30) SDS25212 1" 17.5" 7" WITH EACH PRODUCT. SCHEDULE INTERIOR
(3)2x6 (36) SDS25212 1" 17.5" 7" WALL
HD6 HDU14 2. HD6 REQUIRES A HEAVY HEX NUT, WHICH IS
(3)2x8 (36) SDS25212 1" 20" 8.5"
SUPPLIED BY SIMPSON WITH THE PRODUCT. SHEARWALL SIMPSON A35 ON OPPOSITE FACE OF
SHEATHING TRUSS. STAGGER WITH LTP4 ALONG
NOTES
B

3. THE ANCHORS SHALL BE DRILLED & EPOXIED WITH SIDE ENTIRE SHEARWALL LENGTH.
STRAPS: SIMPSON SET-3G. INSTALL PER MANUFACTURER
REQUIREMENTS.
1. STRAP TOTAL LENGTHS ARE BASED ON USING 18" DRAG TRUSS OVER INTERIOR WALL WITH SHEARWALL SHEATHING ON BOTH SIDES LC Project No.: 1803.011
FLOOR TRUSSES. ADJUST THE LENGTHS AS
REQUIRED FOR DIFFERENT DEPTHS. 4. ANCHORS ARE TO BE ALL-THREAD RODS, A193, Gr.
B7 OR BETTER. Scale: None
2. END LENGTH REFERS TO THE LENGTH OF STRAP
ABOVE THE TOP OF SILL PLATE OR BELOW THE 5. ANCHOR DEPTHS TO BE DRILLED AS SHOWN BASED
ON EITHER A FOUNDATION EDGE LOCATION OR
BOTTOM OF BEARING PLATE WHEN CROSSING THE
FLOOR CAVITY. FOUNDATION INTERIOR LOCATION. Shearwall
3. LAP SPLICES ARE NOT ALLOWED WITHOUT PRIOR 6. DIFFERENT PRODUCTS AND MANUFACTURERS ARE Information
A

APPROVAL FROM THE EOR. NOT ALLOWED WITHOUT APPROVAL FROM THE
EOR.

S030
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

SHEARWALL DRAWING INFORMATION SHEET (CONTINUED) 20. FOLLOWING THE PREVIOUS INSTRUCTIONS, NOTES, SCHEDULES, AND CHARTS WILL ENSURE THAT THE SHEARWALL STACK, FROM FOUNDATION
TO ROOF DECK, IS PROPERLY CONSTRUCTED AND WILL SATISFY THE CONTINUOUS LOAD PATH REQUIREMENTS OF THE BUILDING CODE. THE
STEP3: TRANSFERING SHEAR THROUGH THE FLOOR CAVITY OVERALL SHEARWALL STACK SHOULD LOOK SIMILAR TO THIS DETAIL:
M

14. IN ORDER TO TRANSFER THE SHEAR FROM THE SHEARWALL INTO THE FLOOR DECKING, OR FROM THE SHEARWALL INTO THE FOUNDATION, THE
SHEAR BLOCK SCHEDULE
SILL PLATE MUCH BE ATTACHED WITH THE APPROPRIATE FASTENERS AT CERTAIN SPACING. USING THE TABLE BELOW, FIND THE SHEARWALL SHEARWALL LENGTH
MARK THAT THE SILL PLATE BELONGS TO AND ATTACH IT AS FOLLOWS: DRAG TRUSS 5575 Stousland Rd.
MARK 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 30' 32' 34' 36' 38' 40' 42' 44' 46' 48'
DESIGN BY TRUSS MANUFACTURER College Station, TX 77845
NO. OF BLOCKS REQUIRED BASED ON SHEARWALL LENGTH
(832) 423-2977
GW11 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3
www.laymonconsulting.com
SILL ATTACHMENT SCHEDULE GW12 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 4 4 4 4
GW13 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 4 4 4 4 4 5 5 TX Firm # F-19205
ATTACH. TO FDN. SPA. ATTACH. TO DECK SPA.
MARK 1 GW14 2 2 2 2 2 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 6 6 6
2"Ø BOLTS 0.145"Ø PAF 8d NAIL 16d NAIL PLATES CONNECTING DRAG TRUSS TO SHEARWALL
PW21 2 2 2 2 3 3 3 4 4 4 5 5 6 6 6 7 7 7 8 8 9 9 9 RE: SCHEDULES
PW22 2 2 2 3 4 4 5 5 6 6 7 7 8 8 9 9 10 11 11 12 12 13 13
© 2022
L

GW1 48" O.C. 20" O.C. 14" O.C. 19" O.C. Laymon Consulting, LLC
PW23 2 2 3 4 5 5 6 7 7 8 9 9 10 11 11 12 13 13 14 15 16 16 17
GW2 48" O.C. 11" O.C. 8" O.C. 10" O.C. All rights reserved
PW24 2 3 4 5 5 6 7 8 9 10 11 11 12 13 14 15 16 16 17 18 19 20 21
GW3 48" O.C. 10" O.C. 7" O.C. 9" O.C. The arrangements
DETAIL depicted herein are the
GW11 48" O.C. 17" O.C. 12" O.C. 16" O.C. sole property of Laymon
(12) 0.131" x 3" NAILS
GW12 48" O.C. 13" O.C. 9" O.C. 13" O.C. (2 ROWS OF 6) 20 12" Consulting, LLC and may
not be reproduced in any

SHEARWALL
GW13 48" O.C. 11" O.C. 8" O.C. 10" O.C.

RE: PLAN
TRIMMABLE ENDS TO form without written
GW14 48" O.C. 8" O.C. 5" O.C. 7" O.C. SILL ATTACHMENT TO DECK
ALLOW FOR FIELD permission.
2,000 LBS ADJUSTMENTS RE: SCHEDULE
PW21 32" O.C. 5" O.C. 3" O.C. 5" O.C. END POST
DRAG FORCE
K

PW22 22" O.C. 3" O.C. (2)@5" O.C. 3" O.C. (3 TYPICAL, UNO)
PW23 18" O.C. 3" O.C. (2)@4" O.C. (2)@5" O.C.
PW24 14" O.C. (2)@5" O.C.* (2)@3" O.C. (2)@4" O.C.

NON 48" O.C. 48" O.C. 48" O.C. 48" O.C.

FLOOR CAVITY
STRAP
NOTES:
RE: PLAN
1. SPACING SHOWN ABOVE IS A MAXIMUM SPACING.
TIGHTER SPACING IS ACCEPTABLE, BUT IN NO CASE
SHALL BE CLOSER THAN 3" O.C.

2. BOLTS SHALL BE EMBEDDED INTO THE CONCRETE A


J

MINIMUM OF 7". 18" (12) 0.131" x 3" NAILS


(2 ROWS OF 6)
3. POST-INSTALLED ANCHORS ARE ACCEPTABLE
PROVIDED THE THREADED ROD MEETS ASTM A193,
GR. B7 AND SIMPSON SET-3G EPOXY IS USED. USE NOTES
AN EMBEDMENT DEPTH OF 7".
1. SHEAR BLOCKS SHALL BE DESIGNED TO CARRY A 2,000 LBS DRAG FORCE.

SHEARWALL
SILL ATTACHMENT TO FDN SHEAR BLOCK

RE: PLAN
4. PAF (POWER ACTUATED FASTENER) SHALL BE HILTI RE: SCHEDULE RE: SCHEDULE
X-CP 72 P8 S23. 2. SHEAR BLOCKS ARE TO BE SPACED EQUALLY, AS MUCH AS IS POSSIBLE, ALONG THE LENGTH OF THE
SHEARWALL.
3 END POST
5. PAF AND BOLTS SHALL BE NO CLOSER THAN 1 4"
FROM THE EDGE OF CONCRETE. 3. SHEAR BLOCKS ARE TO BE PLACED DIRECTLY OVER THE SHEARWALL, BETWEEN TRUSSES, AND ATTACHED TO (3 TYPICAL, UNO)
H

THE FLOOR DECK ABOVE AND THE BEARING PLATE BELOW.


6. (*) DENOTES THAT 2X6 MATERIAL MUST BE USED
4. SHEARWALL LENGTHS CAN BE FOUND ON THE SHEARWALL PLANS IN PARENTHESES NEXT TO THE SHEARWALL HOLDOWN
FOR THIS FASTENER TO WORK PROPERLY.
MARK. RE: PLAN

5. IF THE LENGTH SHOWN ON THE PLAN FALLS BETWEEN TWO NUMBERS SHOWN ABOVE, USE THE LARGER

Gandy Residence
LENGTH.

Lubbock, TX 79413
3 6. IF THE LENGTH SHOWN ON THE PLAN IS LONGER THAN SHOWN IN THE ABOVE CHART, CONTACT THE
1 STRUCTURAL ENGINEER OF RECORD FOR THE REQUIRED NUMBER OF SHEAR BLOCKS. SHEARWALL LENGTH
RE: PLAN

3404 47th St.


2 2 7. IF A SHEARWALL IS SHEATHED ON BOTH SIDES, THE NUMBER OF SHEAR BLOCKS SHOWN FOR EACH SIDE IS
G

SHALL BE ADDED TOGETHER FOR A TOTAL NUMBER OF SHEAR BLOCKS REQUIRED.


1'-0"

SILL PLATE
1 SPLICE 8. IF THE TOTAL NUMBER OF SHEAR BLOCKS REQUIRED EXCEEDS THE NUMBER OF SPACES BETWEEN TRUSSES
4"

PROVIDED, CONTACT THE STRUCTURAL ENGINEER OF RECORD FOR A SOLUTION. STEP 4: TRANSFERRING SHEAR AROUND OPENINGS

4" 3 1 3 4" 4" 4 1 21. THERE WILL BE INSTANCES WHERE A WINDOW OPENING OR TWO ARE WITHIN THE SHEARWALL AND INDICATED ON THE PLAN WITH "FTAO" OR
"FORCE TRANSFER AROUND OPENINGS". WHEN THIS IS SHOWN ON THE PLAN, STRAPS AND BLOCKING WILL BE REQUIRED ALONG THE LENGTH OF
1'-0" 4 1'-0" 1'-0" 3 THE SHEARWALL AT THE TOP AND BOTTOM OF THE OPENINGS. THE STRAPS REQUIRED ARE NOTED IN THE CHART BELOW.
19. BLOCKING IN THE FLOOR CAVITY NEEDS TO BE PROVIDED BETWEEN THE END POSTS OF THE WALLS ABOVE AND BELOW THE FLOOR CAVITY.
NOTES BELOW ARE A FEW SCENARIOS WHICH MAY OCCUR. 22. THE STRAPS CAN BE APPLIED OVER OR BENEATH THE PLYWOOD SHEATHING. IT MAY ALSO BE DESIRED TO ROUTE OUT THE STUDS SO AS NOT TO
HAVE A BULGE IN THE SHEATHING OR WALL FINISH.
F

SILL ANCHOR REQUIRED FOR SILL ATTACHMENT AND SPACED


1 PER THE SPACING SHOWN IN THE SILL ANCHORAGE
SCHEDULE.
SHEARWALL END SHEARWALL END
SILL ATTACHMENT SPACING SHOWN PER THE SILL POST ABOVE POST ABOVE LENGTH OF SHEARWALL
2 ATTACHMENT SCHEDULE.
SILL PLATE SILL PLATE
PER THE BUILDING CODE, THE SILL PLATE MUST HAVE AN
3
ANCHOR WITHIN THIS ZONE AT EACH END OF THE SILL PLATE.
REQ'D LENGTH REQ'D LENGTH
4 ADDITIONAL ANCHOR REQUIRED PER THE BUILDING CODE.
2x BLOCKING ON
EACH SIDE OF
E

FLOOR CAVITY FLOOR TRUSS FLOOR TRUSS


15. THE SHEAR MUST NOW TRANSFER THROUGH THE FLOOR CAVITY AND DOWN TO THE SHEARWALL BELOW. BLOCKING TO MATCH
FLOOR TRUSS
END POST BELOW
16. WHEN FLOOR TRUSSES ARE PERPENDICULAR TO THE SHEARWALL, THIS TRANSFER IS HANDLED THROUGH SHEAR BLOCKS. THE SHEAR BLOCKS SHEARWALL SHEARWALL
ARE MANUFACTURED BY THE TRUSS MANUFACTURER AND ARE DESIGNED TO CARRY A 2,000 POUND WIND LOAD FROM THE TOP CHORD, END POST END POST
THROUGH THE DIAGONAL, AND INTO THE BOTTOM CHORD OF THE SHEAR BLOCK. THE TOP AND BOTTOM CHORDS OF THE SHEAR BLOCK MUST BE
ATTACHED TO THE DECKING ABOVE AND THE TOP PLATE OF THE WALL BELOW. THE CHART AT THE TOP OF THE NEXT COLUMN SHOWS THE
NUMBER OF SHEAR BLOCKS REQUIRED BASED OF THE SHEARWALL TYPE BELOW THE SHEAR BLOCKS. BEARING PLATE BEARING PLATE
Issued For Date
17. WHEN FLOOR TRUSSES ARE PARALLEL TO THE SHEARWALL, A FLOOR DRAG TRUSS MUST BE DESIGNED BY AND PROVIDED BY THE TRUSS SHEARWALL END SHEARWALL END
MANUFACTURER. THE FORCE THE DRAG TRUSS IS TO BE DESIGNED FOR CAN BE CALCULATED BY MULTIPLYING THE SHEAR VALUE OF THE POST BELOW POST BELOW Construction 10/24/2022
D

SHEARWALL BELOW THE DRAG TRUSS, WHICH IS GIVEN IN THE "SHEARWALL SCHEDULE" UNDER NOTE 4, BY THE LENGTH OF THE SHEARWALL,
WHICH IS DEMONSTRATED IN NOTE 3. THIS IS THE SAME PROCESS USED TO DETERMINE THE LOAD FOR THE ROOF DRAG TRUSS AS NOTED IN
NOTE 9.
FLOOR TRUSS AWAY FLOOR TRUSS IN LINE
18. THE DRAG TRUSS SHALL BE ATTACHED TO THE TOP PLATE OF THE WALL BELOW WITH THE SAME SILL ATTACHMENT FASTENER AND SPACING AS
IS REQUIRED FOR THE SHEARWALL BELOW THE DRAG TRUSS. THIS CAN BE FOUND IN THE "SILL ATTACHMENT SCHEDULE" SHOWN IN NOTE 14. FROM END POST WITH END POST OPENING IN SHEARWALL
PROVIDE BLOCKING AT STRAP FOR THE
REQ'D LENGTH SHOWN BELOW AT THE TOP
SHEARWALL END AND BOTTOM OF THE OPENING
POST ABOVE
SHEARWALL ABOVE DRAG TRUSS
FTAO REQUIRED STRAPS
SILL PLATE
C

FLOOR STRAP REQ'D LENGTH


1st CS20 12"

(2) 2x BLOCKING NEXT


TO FLOOR TRUSS
DRAG TRUSS
FLOOR TRUSS
FASTENERS PER SILL
ATTACHMENT SCHEDULE OF
THE SHEARWALL BELOW
B

BEARING PLATE
SHEARWALL BELOW DRAG TRUSS
LC Project No.: 1803.011
SHEARWALL END
POST BELOW
Scale: None

FLOOR TRUSS AND END POST Shearwall


AT EXTERIOR WALL
Information
A

S031
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

CONCRETE MASONRY UNIT (CMU) INFORMATION SHEET


STEP 1: HOW TO READ THE PLANS
M

7. ONE COURSE OF BOND BEAM IS REQUIRED AT THE TOP OF ANY CMU WALL. THIS BOND BEAM IS TO BE FULLY GROUTED AND REINFORCED PER 13. SILLS SHALL UTILIZE ONLY ONE COURSE OF BOND BEAMS FULLY GROUTED AND REINFORCED WITH (2)#4 EXTENDING 24" BEYOND THE OPENINGS.
THE "CMU WALL SCHEDULE" IN NOTE 4. THE REINFORCING AT CORNERS AND INTERSECTIONS SHALL BE PER THE DETAIL BELOW. THE PROVIDE A TYPICAL HOOK IF THE MINIMUM LENGTH OF 24" IS NOT AVAILABLE.
1. CONCRETE MASONRY UNIT (CMU) WALLS SHALL BE CONSTRUCTED AS SHOWN WITHIN THIS SET OF DRAWINGS. REINFORCING FOR THIS BOND BEAM MUST STOP WITHIN 2" OF A CONTROL JOINT. SEE NOTE 14 FOR CONTROL JOINT DETAILS AND INFORMATION.
5575 Stousland Rd.
2. MATERIAL SPECIFICATIONS FOR CMU AND REINFORCING STEEL CAN BE FOUND IN THE SPECIFICATION SECTION AT THE BEGINNING OF THIS SET. LAP LENGTH College Station, TX 77845
LAP LENGTH

TOP OF SILL
RE: SCHED. RE: SCHED. (832) 423-2977
3. CMU IS SHOWN IN THE FRAMING PLANS AS THUS: BOND BEAM www.laymonconsulting.com
(2) #4 IN BOND BEAM
BREAK OUT BLOCK FULLY GROUTED
WALLS AS TX Firm # F-19205
LINTEL DESIGNATION CMU WALL DESIGNATION NECESSARY
CMU WALL VERT WALL REINF.
L-1 MW-1 L-1 © 2022
RE: SCHED
L

Laymon Consulting, LLC


BOND BEAM ALLOW VERT All rights reserved
FULLY GROUTED
CORNER REINF. REINF TO
CELLS AT VERT REINF The arrangements
TO MATCH CORNER REINF. CONTINUE
OPENING REQUIRING LINTEL THROUGH BOND
depicted herein are the
HORIZ. REINF. TO MATCH
BEAM sole property of Laymon
HORIZ. REINF.
FILL BOND Consulting, LLC and may
BEAM SOLID 14. CONTROL JOINTS ARE REQUIRED IN ORDER TO CONTROL THE THERMAL EXPANSION AND CONTRACTION OF THE CMU WALL. CONTROL JOINTS not be reproduced in any
4. THE ASSUMED COMPRESSIVE STRENGTH OF THE MASONRY ASSEMBALGE, f'm, IS DEPENDANT UPON THE COMBINED STRENGTH OF THE MORTAR BOND BEAM REINF. SHALL BE CONSTRUCTED IN THE LOCATIONS NOTE BELOW; HOWEVER, REFER TO THE ARCHITECTURAL DRAWINGS FOR ANY ADDITIONAL form without written
AND THE INDIVIDUAL CONCRETE MASONRY UNITS. THE MASONRY ASSEMBLAGE SCHEDULE LOCATED IN THE CMU SPECIFICATIONS AT THE FILL BOND RE: SCHED. LOCATIONS AS WELL AS THE CALUKING, BACKING, AND SEALANT REQUIREMENTS FOR THE CONTROL JOINTS.
ALLOW VERT REINF permission.
BEGINNING OF THIS SET INDICATES THE MORTAR TYPE AND UNIT STRENGTH REQUIRED TO ACHIEVE THE APPROPRIATE COMPRESSIVE STRENGTH BEAM SOLID
BOND BEAM TO CONTINUE A. MAXIMUM SPACING OF 1.5 TIMES THE HEIGHT OF THE WALL, OR 25 FEET, WHICHEVER IS LESS.
OF THE ASSEMBLAGE, f'm. THE FOLLOWING SCHEDULE SHOWS THE REQUIRE f'm FOR THE CMU WALL DESIGNATION SHOWN ON THE PLAN:
REINF. THROUGH BOND B. CHANGES IN WALL HEIGHT.
K

RE: SCHED. BEAM C. CHANGES IN WALL THICKNESS.


D. CONTROL JOINTS IN FOUNDATIONS AND FLOORS.
CMU WALL SCHEDULE CORNER REINFORCING INTERSECTION REINFORCING
CONTROL JOINTS ARE NOT ALLOWED IN RETAINING WALLS OR BELOW GRADE WALLS.
MORTAR VERT B.B. CELL
MARK f'm (PSI)
TYPE REINF REINF GROUT
MW-1 1,500 S #5 @ 32" O.C. (1) #5 RC 8. BOND BEAMS PLACED AT FLOOR AND ROOF LEVELS SHALL BE TWO COURSES DEEP. THIS BOND BEAM IS TO BE FULLY GROUTED AND ℄ JOINT
REINFORCED PER THE "CMU WALL SCHEDULE" IN NOTE 4. THE REINFORCING AT CORNERS AND INTERSECTIONS SHALL BE PER THE DETAIL IN
NOTE 7 ABOVE. THE BIGGEST DIFFERENCE BETWEEN THIS BOND BEAM AND THE BOND BEAM IN NOTE 7 IS THAT THE REINFORCING FOR THIS
BOND BEAM MUST CONTINUE THROUGH ANY CONTROL JOINTS AND SHALL NOT STOP. SEE NOTE 14 FOR CONTROL JOINT DETAILS AND
INFORMATION. ALLOW VERT REINF TO VERT CONTROL JOINT, OMIT
CONTINUE THROUGH MORTAR, CAULK PER ARCH
J

9. THE CMU WALL MUST CONTAIN BOND BEAMS SPACED NO MORE THAN 48" O.C. THESE BOND BEAMS SHALL BE FULLY GROUTED AND REINFORCED BOND BEAM
NOTE:
1. B.B. = BOND BEAM PER THE "CMU WALL SCHEDULE" IN NOTE 4. THE REINFORCING AT CORNERS AND INTERSECTIONS SHALL BE PER THE DETAIL IN NOTE 7 ABOVE.
THE REINFORCING FOR THIS BOND BEAM MUST STOP WITHIN 2" OF A CONTROL JOINT. SEE NOTE 14 FOR CONTROL JOINT DETAILS AND
2. CELL GROUT REFERS TO THE GROUTING INFORMATION.
REQUIREMENTS OF THE CELLS: ONLY AT REINFORCED
CELLS (RC) OR AT EVERY CELL (EC). 10. HORIZONTAL JOINT REINFORCING MUST BE PLACED AT EVERY OTHER JOINT (16" O.C.). THIS SHALL BE GALVANIZED 9GA WIRE REINFORCING,
EITHER LADDER TYPE OR TRUSS TYPE. LEGS MUST BE BENT AND LAPPED 12" AT WALL CORNERS AND INTERSECTIONS. SEE DETAILS IN NOTE 11
STRUCTURAL REINF SHALL
3. CELL GROUT REQUIREMENTS ARE STRUCTURAL BELOW.
CONTINUE THROUGH THE
REQUIREMENTS ONLY. ARCHITECT MAY HAVE MORE CONTROL JOINT
STRINGENT REQUIREMENTS. SEE ARCHITECTURAL 11. WALL INTERSECTIONS MAY BE ACHIEVED BY GROUTING THE WALL CELLS TOGETHER OR BY USING RIGID PARTITION ANCHORS SPACED AT 32" O.C.
DRAWINGS. BOND BEAM REINFORCING THROUGH
H

LAP LEGS 12" (TYP) LAP LEGS 12" (TYP) CONTROL JOINT @ FLOOR/ROOF

5. WITHIN EACH WALL COULD BE OPENINGS FOR DOOR AND WINDOWS. THESE OPENINGS WILL REQUIRE LINTELS DESIGNED AND CONSTRUCTED TO ℄ JOINT
CARRY THE DEAD AND LIVE LOADS OVER THE OPENINGS. THE FOLLOWING SCHEDULE INDICATES THE LINTEL CONSTRUCTION REQUIRED FOR

Gandy Residence
EACH LINTEL DESIGNATION SHOWN ON THE PLANS. TYP VERT REINF. VERT CONTROL JOINT, OMIT
RE: SCHED MORTAR, CAULK PER ARCH

Lubbock, TX 79413
TYP VERT REINF. BREAK OUT
CMU LINTEL SCHEDULE RE: SCHED WALL AND FILL
BOTH CELLS TERMINATE INTERMEDIATE

3404 47th St.


ALLOW VERT REINF TO
SIZE REINFORCEMENT BEARING BOND BEAM REINF 2" FROM
G

MARK FULLY GROUTED FULLY GROUTED CONTINUE THROUGH


W D TOP BOT SHEAR LENGTH CONTROL JOINT
CELLS AT ALL CELLS AT ALL BOND BEAM
L-1 8" 8" - (1) #5 - 8" VERT. REINF.
VERT. REINF.

LADDER REINF. @ LADDER REINF. @


EVERY OTHER EVERY OTHER
NOTE: HORIZ. JOINT HORIZ. JOINT PROVIDE 48" SMOOTH DOWEL (SAME SIZE AS HORIZ REINF)
1. COMPRESSIVE STRENGTH OF THE INDIVIDUAL UNITS, ACROSS THE JOINT. PREVENT BOND BETWEEN BAR AND
f'm, AND MORTAR TYPE SHALL MATCH THE WALL GROUT WITH GREASE OR PLASTIC SLEEVE. CAP ALL DOWELS
REQUIREMENTS FOR WHICH THE LINTEL IS LOCATED. TYP JOINT REINFORCING @ CORNER TYP JOINT REINFORCING @ INTERSECTION TO ALLOW 1" OF MOVEMENT.
F

2. PROVIDE STANDARD HOOK FOR TOP REINFORCEMENT. BOND BEAM REINFORCING THROUGH
CONTROL JOINT @ ALL OTHER LOCATIONS
3. PROVIDE (1) #6 VERTICAL FOR THE FULL DEPTH OF THE
LINTEL IN EACH CALL ACROSS THE FULL BEARING
LENGTH AT EACH END.
LAP LEGS 12" (TYP) LAP LEGS 12" (TYP) ℄ JOINT

6. THE FULL CONSTRUCTION OF A CMU WALL IS SHOWN GRAPHICALLY BELOW. EACH PORTION OF THE WALL IS MARKED WITH A NOTE NUMBER ON VERT CONTROL JOINT, OMIT
TYP VERT REINF.
THIS SHEET TO EXPLAIN MORE FULLY THE DETAIL AND CONSTRUCTION FOR THAT MARKED PORTION OF THE WALL. TYPICAL WALL REINFORCING MORTAR, CAULK PER ARCH
RE: SCHED
E

AS CALLED FOR IN THE "CMU WALL SCHEDULE" ABOVE IS NOT SHOWN FOR CLARITY. CONTACT THE STRUCTURAL ENGINEER OF RECORD SHOULD
YOU HAVE ANY QUESTIONS REGARDING THIS WALL CONSTRUCTION.
TYP VERT REINF. TYP VERT REINF.
RE: SCHED BREAK OUT SIDE RE: SCHED
℄ CONTROL JOINT AND MIDDLE
WALLS AND FILL
FULLY GROUTED ALL THREE CELLS FULLY GROUTED PROVIDE CLOSED END BLOCKS TERMINATE LADDER REINF
NOTE 7 CELLS AT ALL RIGID PARTITION CELLS AT ALL AT CONTROL JOINT (TYP) 2" FROM CONTROL JOINT
VERT. REINF. ANCHOR @ 32" O.C. VERT. REINF.
NOTE 14 VERTICAL HEIGHT Issued For Date
T/WALL
HORIZONTAL JOINT REINFORCING Construction 10/24/2022
D

THROUGH CONTROL JOINT


LADDER REINF. @ LADDER REINF. @
NOTE 8 EVERY OTHER EVERY OTHER
HORIZ. JOINT HORIZ. JOINT
T/FLR OR ROOF

INTERSECTING WALLS W/ OFFSET CELLS RIGID PARTITION ANCHOR @ INTERSECTING WALLS 15. LAP SPLICE AND DEVELOPMENT LENGTH FOR REBAR WITHIN CMU WALLS SHALL BE AS FOLLOWS:
WALL NOTE 9
CORNER NOTE 14
REINFORCING LAP
SIZE LENGTH
#4 24"
C

#5 30"
4'-0" MAX

12. LINTELS SHALL BE REINFORCED PER THE "CMU LINTEL SCHEDULE" AND FULLY GROUTED TO THE DEPTH SHOWN IN THE "CMU LINTEL SCHEDULE". #6 36"
NOTE 12 NOTE 12 LINTEL REINFORCING SHALL EXTEND BEYOND THE OPENINGS FOR THE BEARING LENGTH DISTANCE CALLED FOR IN THE "CMU LINTEL SCHEDULE." #7 42"
NOTE 9 PLEASE NOTICE THE NOTE IN THE "CMU LINTEL SCHEDULE" REFERENCING THE NEED FOR ADDITIONAL VERTICAL REBAR ALONG THE BEARING #8 48"
LENGTH FOR LINTELS REQUIRING TOP REINFORCING.
NOTE 13 FULLY GROUTED
CELLS AT VERT
REINF
4'-0" MAX

VERT WALL REINF.


NOTE 10 TOP REINF.
NOTE 10 OVER LINTEL
HOOK ENDS
B

RE: SCHED
HEADER HEIGHT

HEADER HEIGHT

HEADER HEIGHT

GROUT
T/FTG OR SLAB LINTEL LC Project No.: 1803.011
D

SOLID
SHEAR REINF.
D

BOT. REINF. Scale: None


RE: SCHED RE: SCHED
BOT. REINF. BOT. REINF.
DOWELS TO MATCH VERT REINF AND SPACING.
PROVIDE PROPER LAP LENGTH.
RE: SCHED RE: SCHED
CMU
HOOK VERT REINF

NOTE
W W W
90° AND PARALLEL Information
A

TO WALL
TYPICAL WALL REINFORCING IS NOT SHOWN FOR CLARITY. REFERENCE THE "CMU WALL SCHEDULE" ABOVE FOR THE REQUIRED
REINFORCING SIZE AND SPACING
TYP LINTEL LINTEL W/ SHEAR REINFORCING VERT WAL REINF @ LINTEL

S040
M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

5575 Stousland Rd.


College Station, TX 77845
(832) 423-2977
www.laymonconsulting.com

TX Firm # F-19205

© 2022
L

Laymon Consulting, LLC


All rights reserved
The arrangements
depicted herein are the
sole property of Laymon
Consulting, LLC and may
not be reproduced in any
88'-1112"
form without written
31'-0" 33'-1" 17'-10" 7'-012" permission.
12'-6" 18'-6" 1'-0" 15'-10" 1'-0"
K

2'-0" 16'-6" 1'-0" 13'-10" 1'-0"


2'-0" 8'-0" 6'-6" 12'-10" 1'-0"

1'-712"
1'-0"

1'-0"
2'-0"

2'-0"

1'-0"

1'-0"
J

4'-712"

1'-0"
2'-0"

2'-0"
2'-712"

3'-0"
3'-512"

2'-0"

1'-0"
712"

2"
512"

10'-10"
10'-41
9'-412"
2'-0"

2"
16'-512"

8'-41
7'-412"
7'-914"
14'-512"

8"
H

9'-25

9'-214"
2"
12'-51

2'-6" 5'-6"
7" 1'-5"
1'-51 4" 4'-03 4"

Gandy Residence
2"
1'-5"

51

Lubbock, TX 79413
2'-73 8"

4'-03 4"

3404 47th St.


8'-218"
G

512"

6'-43 8"
8"
37'-412"

37'-412"
9'-15
1'-514"
1'-0"

1'-1012"

5'-1"

32'-9"
8'-0"

8"
3'-27
1'-0"
NOTE: 6'-43 8" 8'-218" 2'-812"

1'-0"
5'-1012" SEE ARCH FOR SLAB DROPS, SLOPES, AND
19'-0"
F

DEPRESSIONS. VERIFY DIMENSIONS WITH

1'-7"

1'-0"
24'-1012" ARCH PRIOR TO PLACING CONCRETE.
4"
6'-93
20'-11"
20'-0"
2'-0"

16'-87 8"
13'-6"
1'-212"
8'-0"

10'-6"
E

612"
7'-7"

914"
512" 33 4"

Issued For Date


1'-0"
512"

Construction 10/24/2022
D

18'-512" 7'-10" 11'-212" 512"


512" 26'-312" 8" 11'-8"
26'-9" 49'-101 2" 12'-4"
88'-1112" 4'-10"
C
B

LC Project No.: 1803.011

Scale: 1/4 = 1'-0"

Slab Forming
Plan
A

S101
M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

5575 Stousland Rd.


College Station, TX 77845
(832) 423-2977
www.laymonconsulting.com

TX Firm # F-19205

© 2022
L

Laymon Consulting, LLC


All rights reserved
The arrangements
depicted herein are the
sole property of Laymon
Consulting, LLC and may
not be reproduced in any
form without written
permission.
K

13
S401
J

6
S401 CMU PLAN NOTES:
1. ALL CMU TO BE 8"x8"x16" BLOCK.
RB-1
RB-2 RB-2 RB-2 RB-2 RB-1
2. SEE S040 FOR ADDITIONAL CMU INFORMATION.

3. REINFORCE CMU WALL AS MW-1 PER SHEET S040.

RE: S010 FOR SLAB 4. PROVIDE FLOOD/AIR VENTS AS REQUIRED.


RE: S010 FOR SLAB
2 THICKNESS AND
THICKNESS AND

RB-1
REINFORCING 5. VENT WIDTHS TO BE A MAXIMUM OF 32" WIDE.

7'-95 8"
REINFORCING S401

RB-2

RB-2

RB-2
H

RB-2

RB-1
2
RB-1

S401 RB-2

RB-1

RB-2
13

2
B-

Gandy Residence
S401

R
9

1
B-
1

Lubbock, TX 79413
B-

R
S401

1
R

F-
5

2
B-
RB-1 S401

3404 47th St.


R
6

R
7'-95 8"

RB-2

RB-2

RB-2

RB-2
G

B-
S401

1
3

B-
2
B-

R
S401
RB-1 R

RB-2
RE: 15/S401
RB-2

R
B-
2
R
B-
2

2
B-
R
10'-512"

13
B-
RB-1

RB-1

7 S401
S401 17
S401

RB-2
4 7'-95 8" RE: S010 FOR SLAB
F

11 THICKNESS AND

RB-2

RB-2

RB-2

RB-2

RB-2
S401
S401 REINFORCING RB-1
RB-1

RB-2

RB-1 RB-1

RB-1
EXTEND BOND BEAM
REBAR 30" INTO SLAB
RB-2
RB-1

RB-1 RB-1

18
12 16 S401

RB-1
S401 RB-1 S401

RB-1
RB-1

RB-1
10'-512"

RB-1
E

RB-2

RB-2

RB-2

RB-2

RB-2
8'-514"
RB-1

10
7'-012"

5'-712"
S401 RE: S010 FOR SLAB

RB-1
THICKNESS AND
REINFORCING

Issued For Date


RB-1 RB-1 RB-2 RB-2 RB-2 RB-2 RB-2 RB-1 RB-1
Construction 10/24/2022
D

9 8 6 EXTEND BOND BEAM 8 8" THICK SLAB IN


S401 S401 S401 REBAR 30" INTO SLAB S401 DOTTED AREA

13'-0" 13'-9" 10'-93 4" 8'-512" 8'-512" 10'-13 4" 10'-11" 13'-5"
C
B

LC Project No.: 1803.011

Scale: 1/4 = 1'-0"

Foundation
Plan
A

S102
M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

5575 Stousland Rd.


College Station, TX 77845
(832) 423-2977
www.laymonconsulting.com

TX Firm # F-19205

© 2022
L

Laymon Consulting, LLC


All rights reserved
The arrangements
depicted herein are the
sole property of Laymon
Consulting, LLC and may
not be reproduced in any
form without written
permission.
K
J

6
S401

3212

3212

3212
H

SLAB-ON-GRADE
SLAB-ON-GRADE

Gandy Residence

Lubbock, TX 79413
" O.C.

3404 47th St.


3212

3212

3212
G

" O.C.

" O.C.

" O.C.

" O.C.

EATED) @ 16
3212

3212
EATED) @ 16

EATED) @ 16

EATED) @ 16

EATED) @ 16
3212

R
2x12 SYP #2 (T
R

R
7
2x12 SYP #2 (T

2x12 SYP #2 (T

2x12 SYP #2 (T

2x12 SYP #2 (T
S401 17
S401

3212

3212

3212

3212

3212
" O.C.
F

REATED) @ 16
SLAB-ON-GRADE

2x12 SYP #2 (T
16 SLAB-ON-GRADE
S401
E

3212

3212

3212

3212

3212
Issued For Date
FIELD FRAME STAIRS
Construction 10/24/2022
D
C
B

LC Project No.: 1803.011

Scale: 1/4 = 1'-0"

1st Floor
Framing Plan
A

S201
M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

5575 Stousland Rd.


College Station, TX 77845
(832) 423-2977
www.laymonconsulting.com

TX Firm # F-19205

© 2022
L

Laymon Consulting, LLC


All rights reserved
The arrangements
depicted herein are the
sole property of Laymon
Consulting, LLC and may
not be reproduced in any
form without written
permission.
K
J

10x10 CEDAR POST WITH 10x10 CEDAR POST WITH


SIMPSON ABU1010 BASE 6x10 CEDAR #2 SIMPSON ABU1010 BASE
328 328 6x10 CEDAR #2
(TYP) (TYP)

6x10 CEDAR #2
6x10 CEDAR #2

328
H

328
17
S402 328

326

Gandy Residence

Lubbock, TX 79413
8

226

226
32

3404 47th St.


328
G

32
10

10
32

326
3212

228
3212

6
22
F

226 226
326

E412

6x10 CEDAR #2
O.C.
#2 @ 16" 228
2x12 SYP

326
SUPPORT BEAM ON CORBELS
226
326
3212
E

228

Issued For Date


Construction 10/24/2022
D
C
B

LC Project No.: 1803.011

Scale: 1/4 = 1'-0"

Ceiling Joist
Framing Plan
A

S202
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

ROOF FRAMING NOTES


M

CEILING JOISTS
1. ALL CEILING JOISTS SHALL BE 2x8 SYP #2 @ 16" O.C.,
UNLESS NOTED OTHERWISE. 5575 Stousland Rd.
College Station, TX 77845
2. ATTACH CEILING JOISTS TO RAFTERS WITH (8) 16d (832) 423-2977
COMMON NAILS. www.laymonconsulting.com

3. BRACE DESIGN SUPPORTS (BDS) ARE FRAMED TX Firm # F-19205


WITHIN THE CEILING JOIST FRAMING AND ARE
SHOWN ON PLAN. THESE ARE MEMBERS
SPECIFICALLY SIZED TO SUPPORT ROOF BRACING © 2022
L

NOTED BELOW IN THE ROOF RAFTER SECTION. Laymon Consulting, LLC


All rights reserved
4. ANY CEILING JOIST SUPPORTING A PURLIN BRACE The arrangements
THAT IS NOT MARKED AS "BDS" ON THE PLAN SHALL
depicted herein are the
BE TRIPLED. CONTACT THE ENGINEER OF RECORD IF
sole property of Laymon
HELP IS DESIRED.
Consulting, LLC and may
5. CEILING JOISTS FRAMED INTO THE FACE OF A BEAM not be reproduced in any
OR A LEDGER SHALL BE HANGERED AND NOT form without written
TOE-NAILED. permission.

6. FOR CEILING JOISTS WITH A DEPTH-TO-THICKNESS


K

RATIO EXCEEDING 6:1, PROVIDE A LINE OF BRIDGING


FOR EVERY 8'-0" OF JOIST SPAN, UNLESS THE TOP
AND BOTTOM OF THE JOISTS ARE ATTACHED TO
SHEATHING MATERIAL.

ROOF RAFTERS
7. ALL ROOF RAFTERS SHALL BE 2x6 SYP #2 @ 16" O.C.,
UNLESS NOTED OTHERWISE.
2x6 @16" O.C. PONY WALL
8. ATTACH ROOF RAFTERS TO BEARING PLATES WITH
BETWEEN BOTTOM OF RAFTERS RE: 11/S402
8 6 8 SIMPSON H2.5A HURRICANE CLIPS.
AND TOP OF CEILING JOIST BELOW.
J

RE: 11/S402 S402 THIS IS NECESSARY TO KEEP LOAD S402 S402


9. RAFTERS SHALL HAVE A MAXIMUM SPAN OF 9'-0"
OFF THE RIDGE BEAM.
BETWEEN SUPPORTS HORIZONTALLY ON PLAN.
THESE SUPPORTS SHALL BE EITHER BEARING WALLS,
BEAMS, RIDGE/HIP/VALLEY MEMBERS, OR PURLINS.

10. ALL RIDGES, HIPS, AND VALLEYS SHALL BE 2x


NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN

RIDGE BEAM
THE CUT END OF THE RAFTER, UNLESS NOTED
OTHERWISE.

O.C.
O.C.
11. COLLAR TIES SHALL NOT BE LESS THAN 1x4 AND

O.C.
H

SHALL BE SPACED AT 48" O.C. MAXIMUM AND WITHIN

#2 @ 16"
#2 @ 16"
24" OF THE RIDGE.

#2 @ 16"

E412
17 12. PROVIDE A CS20x48" LONG AT 48" O.C. MAXIMUM

2x10 SYP
2x8 SYP

S402 PURLINS CENTERED ACROSS THE RIDGE AND ATTACHED TO

2x10 SYP
6 THE TOPS OF OPPOSING RAFTERS.

Gandy Residence
RIDGE BEAM
S402
13. ROOF BRACING SHALL BE PROVIDED IN THE

Lubbock, TX 79413
FOLLOWING MANNER:

A. AT ALL HIP/VALLEY/RIDGE INTERSECTIONS

3404 47th St.


B. PURLINS WITH A FRAMED STUD WALL OR
G

E616
WITH PURLIN BRACES AT 4'-0" O.C.
PURLINS C. ALONG ALL HIPS AND VALLEYS AT 8'-0" O.C.
D. ALONG ALL RIDGES AT 4'-0" O.C., UNLESS

O.C.

O.C.

HIP
3'-0"

RAFTER TIES ARE PROVIDED.

#2 @ 16"

#2 @ 16"

HIP
PURLINS 9. PURLINS SHALL NOT BE SMALLER THAN THE
RIDGE 6
SUPPORTED RAFTER AND SHALL MATCH THE
S402

EY
SUPPORTED RAFTER IN SPECIES AND GRADE.

HIP
2x10 SYP

2x10 SYP

LL
PURLINS SHALL BE BRACED WITH 2x4 SYP #2 PURLIN

VA
BRACES SPACED NO MORE THAN 4'-0" O.C. AND
SLOPED NO GREATER THAN 45° FROM THE VERTICAL.
RIDGE
F

(2)2x BLOCKING 10. ROOF BRACING MAY ONLY BEAR UPON BEAMS AND
TOP PLATES OF WALLS. DO NOT BRACE UPON
(2) RAFTER CEILING JOISTS OR STRONG BACKS UNLESS
DESIGNATED AS A BRACE DESIGN SUPPORT.
RIDGE
11. DO NOT SUPPORT MASONRY ON RAFTERS.
(2) RAFTER
12. CHIMNEY WALLS SHALL BE CONSTRUCTED THROUGH

HIP
PURLINS
THE RAFTERS AND SUPPORTED ON WALLS OR BEAMS
7 BELOW AND SHALL NOT BE SUPPORTED AND
S402 CONSTRUCTED ON TOP OF THE RAFTERS.
E

RIDGE

13. RAFTER SIZES SHOWN ARE FOR STRUCTURAL


REQUIREMENTS ONLY. REFER TO THE
PURLINS ARCHITECTURAL AND M.E.P. PLANS FOR ANY
INSULATION, MECHANICAL, OR ELECTRICAL DEPTH
REQUIREMENTS.
3'-0"

Issued For Date


Construction 10/24/2022
D

6
6 7 S402
S402 S402
C
B

LC Project No.: 1803.011

Scale: 1/4 = 1'-0"

Roof Rafter
Framing Plan
A

S203
M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

5575 Stousland Rd.


College Station, TX 77845
(832) 423-2977
www.laymonconsulting.com

TX Firm # F-19205

© 2022
L

Laymon Consulting, LLC


All rights reserved
The arrangements
depicted herein are the
sole property of Laymon
Consulting, LLC and may
not be reproduced in any
form without written
permission.
K
J

S4 PW21 S4 S4 PW21 S4

S5 PW23 S5

S5
S4
PW23
H

PW23
GW13

GW13

S4

Gandy Residence
S5

Lubbock, TX 79413
PW23

3404 47th St.


G

S4

S4
S4
F

PW23
S4
SIMPSON WSWH24X10
STRONG-WALL

S4
E

S5 PW23 S5

PW23
PW23

S4
NONE PW21 NONE Issued For Date
Construction 10/24/2022
D
C
B

LC Project No.: 1803.011

Scale: 1/4 = 1'-0"

Shearwall
Plan
A

S301
M 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

FOOTING
ROOF RAFTER
#4 NOSING
5575 Stousland Rd.
ROOF DECKING

SCHED.
College Station, TX 77845

DEPTH
(832) 423-2977

SCHED. DEPTH
(8) 0.131" x 3" NAILS

SCHED. DEPTH
www.laymonconsulting.com
PL. HT.

TX Firm # F-19205
LINE
PLATE
SCHED. REINF. SCHED.

VERIFY

SCHED. DEPTH
WIDTH

FIELD
SCHED. © 2022
L

CEILING JOIST REINF. GRADE BEAM Laymon Consulting, LLC


All rights reserved
SIMPSON H2.5A The arrangements
SCHED.
depicted herein are the
EXTERIOR SHEATHING SCHED. (2) #5 sole property of Laymon
SIMPSON SP-2 @ WIDTH REINF. CONT.
EVERY OTHER STUD Consulting, LLC and may
SCHED. not be reproduced in any
WIDTH
EXTERIOR WALL form without written
SCHED. REINF. permission.
NOTE: NOTE: SCHED. WIDTH
NOTE: GRADE BEAM RE: SECTION 6 RE: SECTION 6
K

RE: SECTION 6
FOR INFORMATION FOR INFORMATION
FOR INFORMATION
NOT SHOWN NOT SHOWN
NOT SHOWN
SIMPSON
1 MSTAM36 1 18" FLOOR DECKING 2 3 4 5
@ 32" O.C.
2x12 JOISTS
WOOD BEAM
FLOOR DECKING RE: PLAN
(2) 2x12
TREATED
RIM JOIST SIMPSON LUS210
#4 NOSING
J

1 12" x 5 12" SLAB REINF.

SLAB THICK.
1 12" x 5 12"
SLAB REINF. RE: S010

RE: S010
PLACE TERMITE BRICKLEDGE BRICKLEDGE

SLAB THICK.
RE: S010 DOOR POCKET

FIN FL
SHIELD ON TOP

RE: S010

SLAB THICK.
1'-6" MIN.

CMU STEM WALL

RE: S010
OF CMU

VARIES
SLOPE
SLAB REINF.

FIN FL
FIN FL
RE: S010

8"
FLOOR JOIST
(4)#5 WITH FULLY
RE: PLAN
SCHED. DEPTH

GROUTED CELLS

8"
8"

SCHED. DEPTH
TERMITE SHIELD

SCHED. DEPTH
SCHED. DEPTH
1'-6" MIN

8" CMU PIER


H

1'-6" MIN
1'-6" MIN
1'-6" MIN
COMPACTED BUILDING PAD
SCHED.

COMPACTED BUILDING PAD


DEPTH

COMPACTED BUILDING PAD


1'-6"
MIN

PLACE 6 MIL VAPOR

3"
BARRIER TO REDUCE

Gandy Residence
3"
SCHED. REINF.

3"
MOISTURE AND MOLD
SCHED. WIDTH 3" SCHED. REINF.
POTENTIAL TO THE

Lubbock, TX 79413
3"

3" SCHED. REINF. 3" SCHED. REINF.


FRAMING SCHED.
SCHED. REINF. SCHED. SCHED. WIDTH
WIDTH

3404 47th St.


WIDTH
SCHED. WIDTH
G

6 7 8 9 10

SEE ARCH
#4 x 20" DOWELS @ 18" O.C.
SEE ARCH DRILL & EPOXY 8" INTO
FOUNDATION WITH SIMPSON 1'-35 8"
F

SET-3G EPOXY.
SLAB THICK
VARIES

RE: S010
FIN FL

SLAB REINF.
RE: S010
SLAB THICK.

#4 NOSING (TYP)
RE: S010

#5 IN THE CENTER OF
EACH CELL WITH FULLY
SLAB REINF.
FIN FL

GROUTED CELLS
RE: S010
SCHED. DEPTH

SLOPE
CONCRETE
AND PAVERS

3"
BY OTHERS
1'-0"

1'-35 8"
E

6"
COMPACTED BUILDING PAD
3"

#4 @ 18" O.C. EW
(2) #5 CONT.
3"

COMPACTED
1'-0"

1'-0" BUILDING PAD


3" SCHED. REINF.
NOTES:
SCHED. (2) #4 1. STAIRS MAY BE PLACED INTEGRALLY WITH THE
WIDTH FOUNDATION IF DESIRED. Issued For Date
#4 DOWELS 1'-0" 8" CMU PIER
2. NUMBER OF STAIR MAY VARY FROM SECTION Construction 10/24/2022
RE: PLAN
SHOWN. SEE ARCH FOR STAIRS REQUIRED.
D

11 12 13 15

ALIGN AS REQ'D TO PROVIDE ALIGN AS REQ'D TO PROVIDE


A FLUSH SURFACE A FLUSH SURFACE
C

1 18" DECKING 1 18" DECKING 1 12" x 5 12"


BRICKLEDGE

SLAB THICK.
RE: S010
2x12 2x12
SLAB REINF.
FIN FL

RE: S010
8"
SCHED. DEPTH

SIMPSON LUS210
B

2x12 SYP #2 TREATED LEDGER


1'-6" MIN

(2)2x12 SYP #2 TREATED LEDGER ATTACHED TO CONCRETE W/


RE: 8/S401 FOR RE: 8/S401 FOR
ATTACHED TO CONCRETE W/ (2) THD37600H @ 24" O.C. COMPACTED BUILDING PAD
INFORMATION INFORMATION LC Project No.: 1803.011
(2) THD37600H @ 24" O.C.
NOT SHOWN NOT SHOWN

Scale: 3/4" = 1'-0"


3"
1'-6" MIN

1'-6" MIN

3" SCHED. 3" SCHED.


SCHED.
REINF.
SCHED.
REINF. Foundation
WIDTH WIDTH
Sections
A

16 17 18 S401
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

HR MAX.
2x4 COLLAR TIES
@ 4'-0" O.C. MAX
M

3
1
5575 Stousland Rd.
STAGGER 6" FROM College Station, TX 77845
3" 11 2"
SEE PLANS AND NOTES OPPOSITE SIDE INTERSECTING BEAM (832) 423-2977
FOR RAFTER SIZES

2"

2"

2"

2"

2"
www.laymonconsulting.com
ONLY BEAR POSTS ON CEILING JOIST

HR
SPAN WHERE NOTED ON THE PLANS

EQ
PURLIN SAME SIZE TX Firm # F-19205
AS RAFTER

HR MIN.

EQ
(2)2x6 STRONGBACK CONT.
TO DISTRIBUTE LOAD TO © 2022
L

2x4 POSTS @ 4'-0" CEILING JOISTS Laymon Consulting, LLC

2"

2"

2"

2"

2"
3
SIMPSON H2.5A O.C. DOWN TO TOP 0.131" x 3" NAIL All rights reserved

2
1 SUPPORTING BEAM
@ EACH RAFTER OF BEARING WALL @ 12" O.C. 2"Ø
THROUGH
0.131" x 3" NAIL BOLT W/ WASHERS The arrangements
@ 12" O.C. @ 16" O.C. SIMPSON SDS25600 depicted herein are the
sole property of Laymon
2-PLY CONNECTION 3-PLY CONNECTION 4-PLY+ CONNECTION ADDITIONAL CONNECTION AT INTERSECTING BEAMS Consulting, LLC and may
not be reproduced in any
LINE LINE
PLATE PLATE

form without written


permission.
LAP JOISTS 12" MINIMUM OVER BEARING WALLS THIS CEILING JOIST REQUIRES
SEE PLAN AND NOTES
SPECIAL DESIGN. NATIONAL SPAN
FOR CEILING JOIST SIZES
SCHEDULES DO NOT APPLY.
K

BEARING WALLS. SEE PLANS AND


NOTES FOR STUD SIZES AND SPACING

1 4
J

(4) TOENAILS ROOF DECKING


2x6 OUTRIGGERS
ROOF RAFTER

ROOF DECKING

(8) 0.131" x 3" NAILS LINE


PLATE
ROOF RAFTERS W/
SIMPSON LRU210
STRAP CONNECTING RAFTERS
PL. HT.

(4) SIMPSON SDWC15600


SIMPSON H2.5A ROOF RAFTER
LINE
PLATE
H

6x6 CEDAR POST SIMPSON LRU210


CEILING JOIST
EXTERIOR SHEATHING EXTERIOR WALL (4) SIMPSON SDWC15600
SIMPSON H2.5A

Gandy Residence
EXTERIOR SHEATHING
SIMPSON SP-2 @
EVERY OTHER STUD ROOF DECKING

Lubbock, TX 79413
ROOF DECKING
EXTERIOR WALL
6x10 CEDAR BEAM

3404 47th St.


G

ROOF RAFTER

RIDGE
BEAM
6 7 8
6x10 CEDAR BEAM

6x10 CEDAR BEAM


(5) 0.131"x3" NAILS
F

SIMPSON SDS25800
(2) INTO EACH BEAM

ROOF RAFTERS
6x10 CEDAR BEAM

10x10 CEDAR POST ROOF DECKING


E

ELEVATION VIEW 10x10 CEDAR POST

SIMPSON SDS25800
6x10
CEDAR
BEAM LINE
PLATE

2x6 PONY WALL


SIMPSON H2.5A Issued For Date
PLAN VIEW Construction 10/24/2022
D

11
(5) 0.131"x3" NAILS

EXTERIOR WALL
EXTERIOR
SHEATHING FLOOR DECKING

2x6 @ 16" O.C. JOISTS


C

(4) 0.131"x3" NAILS


RIM JOIST
2x LEDGER

PONY WALL

RIM JOIST
ROOF DECKING
B

LINE
PLATE

SIMPSON H2.5A LC Project No.: 1803.011


CEILING JOIST
RE: PLAN
Scale: 3/4" = 1'-0"
LINE
PLATE

BEARING WALL
SIMPSON H2.5A
EXTERIOR SHEATHING
EXTERIOR WALL Framing
Sections
A

WOOD BEAM
RE: PLAN

17 S402

You might also like