Professional Documents
Culture Documents
Surveyor:
A Perigree Consulting LLC A
9067 S. 1300 W., Suite 304
West Jordan, UT 84088
801-550-3332
Landscape Architect:
Voda Landscape + Planning
Mark Morris
307 West 200 South #3004
Salt Lake City
Utah 84101
(801) 520-5382
Contractor:
Habitat for Humanities
Brendon Critchley
1276 S 500 W
Salt Lake City
Utah 84107
(801) 263-0136
Structural Engineering:
TBD
Mechanical Engineering:
TBD
DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W COVER SHEET
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY
02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214 6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME C 01
06 03/16/16 Update with Planning Commission Requirements, see additional Notes SCALE NTS EST. WGT SHEET OF
1 2 3 4 5
1 2 3 4 5
ARCHITECTURAL NOTES Window Callout Key Door Callout Key Architekt: Contractor:
1. ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL 20. ANCHOR BOLTS FOR FLOOR AS PER STRUCTURAL PLANS. AJR Atelier Jörg Rügemer Habitat for Humanities
CODE FOR RESIDENTIAL DWELLINGS. STRUCTURAL SHALL COMPLY WITH
2015 INTERNATIONAL RESIDENTIAL CODE (2015 INTERNATIONAL RESIDENTIAL 21. CONCRETE FLOOR SLAB ON GRADE TO BE 4” CONCRETE SLAB REINFORCED xx xx xx xx xx xx Jörg Rügemer Brendon
CODE SHALL BE USED WHEN APPLICABLE). WITH FIBER MESH OVER A MINIMUM OF 8” RIGID INSULATION AND OF 6” COMPACTED
125 Parkview Place 1276 S 500 W
[
[
[
[
[
[
Width Height Type Width Height Type
GRAVEL. RADIANT HEATING INSIDE SLAB.
2. ALL SUBMITTALS AND CHANGES TO PLANS SHALL BE APPROVED BY
ATELIER JÖRG RÜGEMER PRIOR TO BEING SUBMITTED TO THE BUILDING 22. SILL PLATE TO BE PRESSURE TREATED 3X ON MANUFACTURED SILL Park City Salt Lake City
OFFICIAL FOR APPROVAL. ENGINEER TO APPROVE ALL STRUCTURAL CHANGES. SEALER (VERIFY WITH STRUCTURAL SHEAR WALL PLANS). ANCHOR BOLTS AS PW Picture Window GD Glass Door Utah 84098 Utah 84107
PER STRUCTURAL PLANS. PLATES TO BE A MINIMUM OF 6” ABOVE GRADE. CS Casement Window SD Solid Door
3. HABITABLE ROOMS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN
AWN Awning Window SD20 Solid Door 20 min
(435) 214-6721 (801) 263-0136
7 FEET MEASURED FROM FINISHED FLOOR TO FINISHED CEILING. BATHROOM 23. CURB, GUTTER AT FRONTAGE OF LOT SHALL BE INSTALLED AT THE TIME
SHALL HAVE A MINIMUM CEILING HEIGHT OF 6 FEET 8 INCHES AT THE CENTER OF NEW CONSTRUCTION. CURB, GUTTER AND SIDEWALK MUST BE CLEAN AND IN GD Glass Door
OF THE FRONT CLEARANCE AREA FOR FIXTURES. NEW CONDITION AT TIME OF FINAL INSPECTION.
Landscape Architect: Structural Engineering:
A 4. MINIMUM WINDOW AREA SHALL EQUAL NOT LESS THAN 8% OF THE 24. APPROVED NUMBERS SHALL BE PROVIDED FOR ADDRESS OF NEW A
FLOOR AREA OF THE ROOM UNLESS ARTIFICIAL LIGHT IS PROVIDED CAPABLE BUILDING PLACED IN POSITION, WHICH IS PLAINLY VISIBLE AND LEGIBLE FROM Voda Landscape + Planning TBD
OF PRODUCING AN AVERAGE ILLUMINATION OF 6 FOOTCANDLES OVER THE
AREA OF THE ROOM AT A HEIGHT OF 30 INCHES.
STREET AT FRONTAGE OF PROPERTY. Mark Morris
25. STAIR CONSTRUCTION TO BE MINIMUM (3) 2X12 STRINGERS WITH ¾” 307 West 200 South #3004
PR
5. NATURAL VENTILATION EQUALING 4% OF THE FLOOR AREA SHALL BE HARDWOOD RISERS AND 5/4” PARTICLE BOARD TREADS WITH HARDWOOD STAIR
THROUGH WINDOWS, DOORS, LOUVERS OR OTHER APPROVED OPENINGS TO SKIRT AS PER ARCHITECT/OWNER. PROVED ½” GYPSUM BOARD ON WALLS AND Salt Lake City Mechanical Engineering:
THE OUTDOOR UNLESS AN APPROVED MECHANICAL VENTILATION SYSTEM IS SOFFITS UNDER ENCLOSED STAIRWAY. PROVIDE 6’-8” HEAD CLEARANCE AT ALL
PROVIDED CAPABLE OF PRODUCING AN AVERAGE OF 0.35 AIR CHANGES PER POINTS. STAIRWAYS SHALL NOT BE LESS THAN 36” IN CLEAR WIDTH AT ALL POINTS Utah 84101 TBD
HOUR IN THE ROOM OR A WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM ABOVE THE PERMITTED HANDRAIL HEIGHT. HANDRAILS MUST BE INSTALLED ON
IS INSTALLED. ALL STAIRS WITH (2) OR MORE RISERS. HANDRAILS SHALL RETURN TO WALL OR (801) 520-5382
EL
TERMINATE INTO NEWEL POSTS OR SAFETY TERMINALS. HAND RAILINGS SHALL
6. PROVIDE 30” INTERLAYMENT BETWEEN COURSES OF SHAKES. ROOF
VALLEY FLASHING SHALL BE MINIMUM 28 GALVANIZED SHEET GAUGE
NOT BE LESS THAN 34” ABOVE NOSE OF THREAD NOR MORE THAN 38” ABOVE
NOSE OF THREAD. HANDRAILS SHALL HAVE A DIAMETER NOT LESS THAN 1-1/8”
Exterior Window and Door Schedule
CORROSION-RESISTANT METAL EXTENDING AT LEAST 11 INCHES FROM AND NO MORE THAN 2-5/8”. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5” ON
CENTERLINE EACH WAY. SHOW ICE SHIELD EXTENDING FROM THE EAVES TO EITHER SIDE. HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF
A POINT AT LEAST 24 INCHES INSIDE THE EXTERIOR WALL LINE. NOT LESS THAN 1.5” BETWEEN THAT WALL AND THE HANDRAIL.
36" 42" CS 60" 42" AWN
Tempered glass
36" 42" CS
Square footages
IM
7. ASPHALT SHINGLE, CLAY, CONCRETE TILE, METAL SHINGLE, MINERAL- 26. GUARDRAILS SHALL NOT BE LESS THAN 36” IN HEIGHT. OPEN RAILINGS
SURFACED ROLL ROOFING, SLATE AND SLATE-TYPE SHINGLE, WOOD SHINGLE, SHALL HAVE INTERMITTENT RAILS SPACED SUCH THAT A 4” SPHERICAL OBJECT
AND WOOD SHAKE ROOF MATERIALS REQUIRE AN ICE BARRIER THAT EXTENDS CANNOT PASS THROUGH.
01. 01a. 02. 03. 03a.
Gross area 3-BR Units
FROM THE EDGE OF THE EAVES TO A POINT NOT LESS THAN 24 INCHES INSIDE 84" 42" PW 84" 42" PW
IN
THE EXTERIOR WALL LINE OF THE BUILDING. 27. ALLOW 30” MIN. CLEARANCE BETWEEN RANGE TOP AND COMBUSTIBLE
MATERIALS. ALLOW SIDE CLEARANCE PER MANUFACTURER SPECS ON Space sft.
8. ALL CONSTRUCTION DEBRIS SHALL BE REMOVED BY FINAL INSPECTION. APPLIANCE. RANGE HOOD SHALL VENT TO THE OUTSIDE WITH SINGLE WALL PIPE
South facade
CONSTRUCTION DEBRIS SHALL BE SECURED ATALL STAGES OF CONSTRUCTION WITH A 1” MIN. CLEARANCE FROM COMBUSTIBLE MATERIALS.
84" 102" PW 36" 96" SD 84" 96" PW
TO PREVENT TRAVELING FROM JOB SITE.
A
28. CONTRACTOR SHALL REVIEW AND VERIFY ALL NOTES, DIMENSIONS,
9. NO STUMPS, ROOTS, OR ORGANIC MATERIAL SHALL BE PRESENT IN LOCATIONS, ETC. PRIOR TO ANY PHASE OF CONSTRUCTION. ANY EXISTING Main floor 665
SOIL AT THE AREA OF THE BUILDING. STRUCTURES SHALL BE FIELD VERIFIED AND SHALL TAKE PRECEDENCE OVER
R
ANY EXISTING DRAWINGS.
10. PROVIDE EXTERIOR GRADE PLYWOOD OR OTHER APPROVED EXTERIOR Second floor 745
MATERIALS FOR SOFFITS. 29. COORDINATE ALL ELECTRICAL AND MECHANICAL WITH PLANS FOR
Y
LOCATION. FOLLOW CODE IN ALL CASES. 04a. 04.
A1. 05. 05a.
CONERS, UNLESS NOTED OTHERWISE. FINISH MATERIALS TO ALWAYS 2. ALL WINDOWS ARE HIGH-PERFORMING WINDOWS AS PER SEFAIRA
B TRANSITION FLUSH. ENERGY MODELING, WITH A MINIMUM U-VALUE OF 0.25 OR BETTER. SHGC AS PER 06. 07. 07a.
08.
B
DRAWINGS AND SEFAIRA ENERGY MODEL. CONSULT ATELIER JÖRG RÜGEMER. 09.
East facade
14. ALL EXPOSED FLASHING, COUNTER FLASHING, DRIP FLASHING, ETC. FIELD VERIFY ALL WINDOW ROUGH OPENINGS BEFORE ORDERING. WINDOW
TO BE 20 GA ALUM. IN COLOR AS SELECTED BY ITAC. FLASHING SHALL BE SUPPLIER TO VERIFY THAT WINDOWS WILL MEET LIGHT, VENTILATION AND EGRESS
84" 42" PW
Sheet Index:
INSTALLED AT THE PERIMETERS OF THE EXTERIOR OF EXTERIOR DOOR AND REQUIREMENTS. PROVIDE TEMPERED GLASS WHERE REQUIRED. PROVIDE 24
WINDOW ASSEMBLIES, PENETRATIONS AND TERMINATION OF EXTERIOR WALL GAUGE DRIP FLASHING OVER HEADS OF ALL WINDOWS AT EXTERIOR. PROVIDE 54" 29" PW 54" 29" AWN
ASSEMBLIES, EXTERIOR WALL INTERSECTIONS WITH ROOFS, CHIMNEYS,
PORCHES, DECKS, BALCONIES AND SIMILAR PROJECTIONS AND AT GUTTERS
AIRTIGHT WINDOW SEAL AND INSULATION SEALER AT ALL SHIM CAVITIES. Tempered glass
Architectural:
AND SIMILAR LOCATIONS WHERE MOISTURE COULD ENTER THE WALL. 3. ALL GLAZING USED IN ENTRANCE DOOR SHALL BE TEMPERED. 10. 11. 12. 13. 14.
PER PLANS) WITH DOUBLE TOP PLATE (UNLESS STATED OTHERWISE). PROVIDE 84" 18" PW 36" 88" GD
19.
Tempered glass
TREATED SOLE PLATE WHERE IN CONTACT WITH CONCRETE. PROVIDE SOLID S 02 Site Plan
17.
2X MID SPAN BLOCKING IN WALLS EXCEEDING 10’-0”. PROVIDE ½” GYPSUM Back entry door
Tempered glass
BOARD ON BOTH SIDES. WRAP ALL PLUMBING FIXTURE WASTE LINES WITH
ROCK WOOL TO DAMPEN SOUND TRANSMISSION WHERE APPLICABLE.
96" 32" PW
S 03 Site Elevations
A 01 Roof/Landscape Overview
17. ANY EARTH FILL TO SUPPORT CONCRETE FLOORS, WALKS, DRIVEWAYS,
ETC. MUST BE COMPACTED TO 95% IN WHICH CONSTRUCTION TAKES PLACE.
18. 18a.
A 02 3-BR North Unit Main Floor Plan
18. FINISH GRADING TO PROVIDE FOR DRAINAGE AWAY FROM BUILDING
AND CONTAINMENT OF DRAINAGE WITHIN PROPERTY. GRADE SHALL SLOPE A 36" 32" CS A 03 3-BR North Unit Upper Floor Plan
MINIMUM OF 6” IN THE FIRST 10’-0” AWAY FROM BUILDING. A 04 5-BR North Unit Basement Floor Plan
19. FOUNDATION WALL TO BE 8” THICK AS PER PLANS. TOP OF WALL TO BE
A MINIMUM OF 8” ABOVE FINISH GRADE. PROVIDE ASPHALT BASE EMULSION 56" 42" PW 18" 40" CS 96" 32" PW
A 05 5-BR North Unit Main Floor Plan
WATERPROOFING (O.A.E.) AT EXTERIOR OF FOUNDATION WALL BELOW FINISH A 06 5-BR North Unit Upper Floor Plan
GRADE. PROVIDE GEOCOMPOSIT STRIP DRAIN AROUND PERIMETER OF
STRUCTURE AS PER PLANS. DRAIN TO BE “ECODRAIN-DS” (O.A.E.) INSTALLED
18" 96" PW
Tempered glass 22. 22a.
A 07 Section AA 3-BR North Unit
AS PER MFG. AND DETAILS. DRAIN TO DAYLIGHT. CONTRACTOR TO CONTACT
A 08 Section BB 3-BR North Unit
20. 20a. 23.
Field of Dreams Eco Community - Habitat for Humanity Housing in Kearns, Utah
DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W GENERAL NOTES
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are 02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214 6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME N 01
06 03/16/16 Update with Planning Commission Requirements, see additional Notes
SCALE NTS EST. WGT SHEET OF
1 2 3 4 5
1 2 3 4 5
SS
A A
SS
SS
SS
Existing Tree
4'-2" to be removed
SS
Lot 255 Wall, h ~ 6'-0" PP1 Lot 254 Lot 253 Lot 252 Lot 251 Lot 250 Lot 249 Lot 248
R=5.00'
4627 Perimeter Fencing Untreated Cedar 6' high 348.50' 4627 4626
PP PP
PP1
PP PP PP PP PP PP PP PP
W
PP1
PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP
PP PP PP
D
PP
H
PP
Y
SLCO Drive
WM
retain if possible
Approach
to be clad in cedar boards (Asphalt)
20'-0"
Lot 8
4'-9" 12" Concr. Ctr. Drain 53'-11"
SS
Common Area
W
6" Concr. Curb
Landscaped
R=5.00'
7'-0" 15'-0"
13'-0"
R
Limited Common Limited Common
17'-0"
=2
8.
00
'
Existing Curb
SS
Existing Gutter
38'-0"
North
SSCO
Townhouse
85'-5"
S 6/12 4/12 6/12 4/12 6/12 4/12
Berm
26.5º 18.4º 30'-11" 30'-11" 26.5º 18.4º 26.5º 18.4º
LP1 W.
PP
Units PP
38'-0"
4" 11'-0" 19'-7" 19'-7" 11'-0" 4"
PP
SS
SSCO PP
PP
W
Lot Size: PP Lot Size: Existing Tree
LP1 E.
19'-7" x 38'-0" PP 19'-7" x 38'-0" to be removed
Lot Size:
19'-7" x 38'-0"
744 SF PP Lot Size:
19'-7" x 38'-0"
744 SF
SS
W
Paramount Park No. 2
14'-5"
Limited Common Limited Common
3'-10"
10'-5"
4627
SS
5'-0"
Sidewalk Lot 10
Bicycle Parking
SS
W
Refurbished Heritage Field Gate 12x60' Tod Lot
Existing Sidewalk
Courts 750 SF
to be removed
Misty Way
60'-0"
249'-8"
Lawn Area
Sidewalk
249.80'
60' x 200' Sand Public Parking (3)
SS
12,000 SF
250.20'
250'-2"
Box
LEGEND
SS
5'-0"
Sidewalk
Property Boundary
2x Private Parking
B B
Lot 11
SS
Waterway
3'-10"
10'-5"
13'-5"
Property Corner
Limited Common Limited Common
Perimeter Fencing
Berm
Untreated Cedar
(Asphalt)
Lot 20 Lot 18 Lot 16 Lot 14 Lot 12
SS
38'-0"
6/12
26.5º
4/12
18.4º
6/12
26.5º
4/12
18.4º
6/12
26.5º
4/12
18.4º
6/12
26.5º
4/12
18.4º
6/12
26.5º
4/12
18.4º Power Pole
30'-11" 30'-11"
4" 11'-0" 19'-7" 19'-7" 11'-0" 4"
Ext. Light Pole
W
South
SS
85'-5"
40'-0"
Lot 10
Lot Size:
19'-7" x 38'-0"
Lot Size:
19'-7" x 38'-0" Townhouse Lot Size:
19'-7" x 38'-0"
Lot Size:
19'-7" x 38'-0"
Existing Curb 744 SF 744 SF
Units 744 SF 744 SF
Existing Gutter
PP Power Line
17'-0"
W
SS
12'-0"
4627
'
7'-0" 15'-5"
00
Limited Common Limited Common
8.
=2
FH
R
R=5.00'
20'-0"
W
SS
R=5.00'
4627 4626 4625
Fire Lot 6 Lot 5 Lot 4 Lot 3 Lot 2 Lot 1
348'-6"
W
Hydrant
SS
S
SS
100'-0" Elevation
W
SS
W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W W North
SS
C CL Street C
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction.
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 0' 30' 60' 90' 120'
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
Graphic Scale (in feet) 1"=30'
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
AJR Atelier Jörg Rügemer harmless. Field of Dreams Eco Community - Habitat for Humanity Housing in Kearns, Utah DESIGNED BY
DATE
c 2015-2016 AJR Atelier Jörg Rügemer AJR Atelier Jörg Rügemer
DRAWN BY
SECTION TOWNSHIP RANGE Acreage CLIENT SITE PLAN SURVEYOR
AJR TITLE
Habitat for Humanities Atelier Jörg Rügemer Perigree Consulting LLC CHECKED BY
18 2 South 1 West, Salt Lake Base and Meridian 2.00 acre (87,120 sft) 1276 S 500 W 125 Parkview Place 9067 S. 1300 W., Suite 304 SITE PLAN
Salt Lake City, UT 84107 Park City, Utah 84098 West Jordan, UT 84088 APPROVED BY
1 2 3 4 5
1 2 3 4 5
12" Concrete Gutter 12" Concrete Gutter
4'-0" 7'-0"9'-0"
Basement 660 sft.
Top Floor745 sft. 665 sft. 255 sft.
A 1,410 sft. Radiant Heating 2,070 sft. A
6'-0"
Drywall, white walls and ceiling
10'-0"
1/2 Bath (33 sft net):
Bench with 80 Gal.
Sealed concrete floor
20'-0" Rainwater Tank Radiant Heating 19'-7"
4'-0"
4'-0"
Front Porch
9 7/8" 2'-2" 2'-1" 1'-1" 3'-1" 2'-10" 5'-8" 1'-7" 8"
Drywall white walls and ceiling, tiles TBD 5'-8" 2'-10" 3'-1" 1'-1" 2'-1" 1'-7" 8" 8" 8" 1'-7"
and Deck 8" 1'-7"
333 sft. All plumbing front-wall and in-ceiling installation (firewall) The plans would also need t
8" Concrete 8" Concrete 8" Concrete
1'-0"
Light Well below
Fire Wall Fire Wall Fire Wall continue up around the cen
Mechanical (33 sft net):
1'-2"
Bench with 80 Gal.
The drain could not have pe
Hidden Drain
Rainwater Tank 19'-7"
4'-0"
Sealed concrete floor
3'-4"
No Plumbing
8" 1'-7" 5'-8" 2'-10" 3'-1" 1'-1" 2'-1" 2'-2"
in Fire Wall
Drywall white walls and ceiling
No Plumbing
in Fire Wall
All plumbing and ductwork front-wall and in-ceiling installation
1'-0"
1/2 Bath Total Gross Area
(firewall)
1'-2"
Concr. fl.
2'-8"
Kitchen + Main Floor 665 sft.
10'-5"
10'-5"
Hidden Drain
33 sft. Dining Top Floor745 sft.
3'-4"
No Plumbing
Concrete floor Exterior Areas 1,410 sft.
in Fire Wall
200 sft.
See also Landscape Plans
8 5/8" 2'-6"
11'-0" 11'-0"
1'-8"
10'-5"
2'-6"
3'-11"
Mechanical
Concr. fl.
11'-0" 33 sft.
2'-11"
5'-0"
2'-6"
33'-10"
33'-10"
10'-5"
10'-5"
A 05
BB
12'-6"
31'-6"
Up Up Up
16 Risers 16 Risers 16 Rise
0'-0" 0'-0"
8'-7"
4,627' 4,627'
B B
12'-8 1/2"
31'-6"
Up
16 Risers
0'-0"
4,627'
7 1/2"x10"
Gross Area First 665 sft
13'-0"
13'-0"
Trash Bins Trash Bins Trash Bins
Gross Area Second 745 sft
10" 3'-0" 2'-5" 12'-8" 1'-2" 3'-0" 8'-0" 8'-0" 3'-0" 1'-2" 12'-8" 2'-5" 3'-0" 10" 3'-0
14'-10"
Fire Wall
7'-1"
Universal Design Components [Type C IBC 2009]:
Hidden Drain
Living Room
8'-0" 3'-0" 1'-2" 12'-8" 2'-5" 3'-0" Concrete floor
225 sft.
• Equitable use
Fire Wall
7'-1"
1'-2"
1'-2"
• Flexibility in use for housing The plans would also need t
5'-5" 10'-9" • Simple and intuitive design 3'-1" 10'-9"
continue up5'-5"
around the cen5
Hidden Drain
3'-0"
• Smooth, ground level entrances without stairs Storag
4'-2"
60 SF
5'-2"
Planters 100 Gal Planters • Surface materials conrete and wood require low force to traverse
Planters
1'-2"
Rainwtr.
on level [less than 5 pounds force per 120 pounds rolling
Light Well below
5'-2"
2'-2"
force]
10'-9" 5'-5" 3'-10" 12'-9" 3'-1"
• Surfaces are stable, firm, and slip resistant per ASTM 2047
3'-6"
2'-2"
• 3’-0” interior main doors and hallways, 60” × 60”8" turning space at
4'-2"
10'-11"
Fire Wall
19'-7" 19'-7"
11'-3"
A 04
including fire alarm pull stations
30'-11" 30'-11" • Components that do not require tight 30'-11"
Fire Wall
Fire Wall
• Lutron light switches with large flat panels
• Buttons and other controls that can be distinguished by touch
Storage
56 SF
Storage
70 SF • Bright and appropriate daylighting, artificial and particularly task
6' Cedar Fence 6' Cedar Fence 6' Cedar Fence
C lighting C
Field of Dreams Eco Community - Habitat for Humanity Housing in Kearns, Utah DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES
3 BR UNIT MAIN
CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY FLOOR PLANS (TYP)
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214-6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME A 02
06 03/16/16 Update with Planning Commission Requirements, see additional Notes SCALE 1/4"=1'-0" EST. WGT SHEET OF
1 2 3 4 5
1 2 3 4 5
19'-7"
8" Concrete Bedroom III (1288" sft net):
Concrete The plans would also need t
1'-0"
11'-0" 9'-8" 9'-7" Fire Wall Hardwood floor Fire Wall continue up around the cen
1'-2"
The drain could not have pe
Hidden Drain
2'-3" 8'-6" 4'-2" 2'-1" 2'-2" Drywall, white walls and ceiling
No Plumbing
4'-0"
Bedroom III Cabinets IKEA PAX
in Fire Wall
128 sft.
8" Concrete
Fire Wall Bath Bathroom (55 sft net):
1'-2"
55 sft. 1'-2" Tile floor 1'-2"
Hidden Drain
8'-7"
Sink, Tub TBD
No Plumbing
6" 6'-1" 6'-1" 6" 6"
in Fire Wall
13'-10"
13'-10"
Dual flush toilet with tank mounted in wall
12'-3 1/2"
Drywall, white walls and ceiling, tiles TBD
1'-2"
All plumbing front-wall and in-floor installation (firewall)
8'-7"
4 1/2"
6'-1" 6"
Washer/Dryer (15 sft net):
13'-10"
12'-3 1/2"
3'-0" 3" 3'-4" 4 1/2" Drain pan 4 1/2" 3'-4" 3" 3'-0" 3'-0
Drywall, white walls and ceiling
3'-0"
All plumbing front-wall and in-floor installation (firewall)
4 1/2"
+Stair
97 sft. Corridor and Stair (97 sft net):
38'-0" Roof Ridge Lenght
3'-0"
Drywall, white walls and ceiling
38'-0"
4 1/2"
7'-0"
7'-0"
A 05
4,627' +10'-0"
BB
Down +10'-0" 4,627'
11'-1" 4 1/2" 3'-4" 16 Risers
13'-7"
7 1/2"x10"
7'-0"
B +10'-0" B
9'-2"
4,627' W/D
15 sft.
13'-7" Gross Area First 665 sft
Bedroom II
156 sft. Gross Area Second 745 sft
4 1/2"
4 1/2"
Gross area: 1,410 sft
No Plumbing
4 1/2"
in Fire Wall
Bedroom I
4'-9"
17'-2"
17'-2"
162 sft.
9'-0"
9'-0"
4 1/2"
• Equitable use
Hidden Drain
17'-2"
Fire Wall
Fire Wall The drain could not have pe
• Smooth, ground level entrances without stairs
1'-2"
9'-0"
9'-0"
1'-0"
• Surfaces are stable, firm, and slip resistant per ASTM 2047
• 3’-0” interior main doors and11'-4" 8" 2'-5"
turning space at7'-9" 1'-11" 3'-1" 2'-10" 8" 8" 8" 2'-
4'-0"
hallways, 60” × 60”
1'-2"
19'-7"
doors and dead-ends on ground level 30'-11"
• Functional clearances for approach and use of elements and
components
11'-4" 3'-1" 7'-9" 1'-11" 3'-1" 4'-2" • Lever handles for all opening doors
AA
19'-7" A 04
• Single-hand operation with closed fist for operable components
including fire alarm pull stations
30'-11" 30'-11" • Components that do not require tight
grasping, pinching or twisting of the wrist
• Components that require less than 5 pounds of force to operate
• Lutron light switches with large flat panels
• Buttons and other controls that can be distinguished by touch
Roof Roof Roof
Storage • Bright and appropriate daylighting, artificial and particularly task Storage Stora
C lighting C
Field of Dreams Eco Community - Habitat for Humanity Housing in Kearns, Utah DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES
3 BR UNIT UPPER
CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY FLOOR PLANS (TYP)
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214-6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME A 03
06 03/16/16 Update with Planning Commission Requirements, see additional Notes SCALE 1/4"=1'-0" EST. WGT SHEET OF
1 2 3 4 5
Livingroom
1 2 3 4 5
2 1/2"
0'-0" Radiant Heat in Concrete Floor
6' Cedar Perimeter Fence Access and Fire Lane Loop Entrance Rear Deck and Storage Sidewalk Common Lawn Area
1'-0"
-5'-6 1/2"
8'-0"
-9'-2 1/2" Bedroom IV Bedroom V
Radiant Heat in Concrete Floor
4"
1'-0"
A A
38'-0"
18'-4"
3'-5"
B B
10'-1"
6'-8"
Bedroom I Bedroom II Bedroom III 10'-0"
9'-0"
1'-0"
5'-2"
9'-0"
Kitchen
Livingroom
0'-0"
4"
6" 4"
6" 4"
10" EPS/Geofoam
-0'-10"
6' Cedar Perimeter Fence Access and Fire Lane Loop Entrance Rear Deck and Storage Sidewalk Common Lawn Area
10"
C C
Field of Dreams Eco Community - Habitat for Humanity Housing in Kearns, Utah DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W SECTION AA - 2-STORY
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY
02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214-6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME A 07
06 03/16/16 Update with Planning Commission Requirements, see additional Notes SCALE 1/4"=1'-0" EST. WGT SHEET OF
1 2 3 4 5
2 1/2"
Kitchen
1 2 0'-0"
3 4 5
Parking
1'-0"
8'-0"
3.The plans also show a potential frost protected shallow
foundation. If this option is used, will need to provide
documentation at the building permit plan review stage
justifying this design. With the amount of foam insulation -9'-2 1/2" Radiant Heat in Concrete Floor
4"
that this protected foundation would be relying on the heat
from the earth instead of from the structure to keep the ground
1'-0"
under the foundation from freezing.
A 6" SIPs A
8" SIPs
Center Roof Drain
3/4 to 12 / 3.6% Slope
Open Glue Lam
Hiddden Linear Ceiling Beam
Drain, 2% Slope Space
Exposed
SIPs OSB Hiddden
Ceiling Linear Drain
1+1h
Fire/Party
19'-7" Wall 19'-7"
24'-2"
7/12
7/12 30º slope
30º slope R-60 Roof
6'-6"
Gallery Attic Space
(optional)
18'-4"
1'-0"
Exposed Exposed
1'-0"
Ceiling Ceiling
11 7/8" TJI 210
1+1h
Party
Wall
B B
8'-0"
7'-6"
6'-10"
6'-8"
12" SIPs R-45
Ext. Wall
5" 5" R-40
Bedroom II Ext. Wall
10'-0"
9'-0" 11 7/8" TJI 210
1'-0"
6' concr. Stem Wall
as 2h Firewall 6'-0" 8"
between parking
9'-0"
6' concr. Stem Wall
as 2h Firewall
between parking Frost Protected
8" 11'-0" Shallow Foundation
2" 2 lb XPS
Kitchen
0'-0"
4"
6" 4"
-0'-10"
12" EPS 10" EPS/Geofoam
12" EPS
Parking
10"
R-32
Floor
12" 2 lb EPS
Geofoam 12" 2 lb EPS Perimeter
Geofoam Drain
C C
DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W SECTION BB - 2-STORY
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY
02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214-6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME A 08
06 03/16/16 Update with Planning Commission Requirements, see additional Notes SCALE 1/4"=1'-0" EST. WGT SHEET OF
1 2 3 4 5
1 2 3 4 5
10'-0"
9'-0" Building Materials Proposed:
Cement Stucco
6'-0"
Cement Board (Hardiboard)
28'-4"
24'-2"
B B
18'-4"
10'-0"
9'-0"
6'-0"
0'-0"
-0'-10"
19'-7" 19'-7"
C C
DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W ELEVATIONS NORTH STREET
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY
02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214-6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME A 11
06 03/16/16 Update with Planning Commission Requirements, see additional Notes SCALE 1/4"=1'-0" EST. WGT SHEET OF
1 2 3 4 5
1 2 3 4 5
10'-0" 10'-0"
9'-0" 9'-0" Building Materials Proposed:
Cement Stucco
6'-0" 6'-0"
Cement Board (Hardiboard)
0'-0" 0'-0"
Possible Color Variations
A -0'-10" -0'-10"
Common Yard
A
Access and Fire Lane Easement Entrance Parking Rear Deck and Storage
Light Grey 190/190/190 RGB
38'-0"
(Cement Stucco)
28'-4"
24'-2"
B 18'-4"
B
10'-0"
9'-0"
6'-0"
0'-0"
-0'-10"
C C
DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W ELEVATIONS SOUTH YARDS
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY
02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines 28'-4"
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214-6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME A 12
06 03/16/16 Update with Planning Commission Requirements, see additional Notes 151220_HFH SCALE 1/4"=1'-0" EST. WGT SHEET OF
24'-2"
1 2 3 4 5
1 2 3 4 5
Cement Stucco
28'-4" 28'-4"
24'-2" 24'-2"
B 18'-4" 18'-4"
B
10'-0" 10'-0"
9'-0" 9'-0"
6'-0" 6'-0"
0'-0" 0'-0"
-0'-10" -0'-10"
Common Yard
Access and Fire Lane Easement Entrance Parking Rear Deck and Storage
38'-0"
C C
DESIGNED BY
DATE
AJR Atelier Jörg Rügemer 08/08/2016
REVISIONS REVISIONS ARCHITECT CLIENT
DRAWN BY
Contractor and all sub contractors working on this project take full liability of these plans and shall thoroughly AJR TITLE
review and verify all dimensions, locations, notes, etc. prior to starting any stage of construction. No. Date Description No. Date Description AJR ATELIER HABITAT FOR HUMANITIES CHECKED BY
01 10/01/15 Site adj.; 40’ rooflines; 9’ grndfl. ceiling; 6” roofline ext.; yard overhang red. 07 05/09/16 Reworking roofs, site plan, elevations according to client commission JÖRG RÜGEMER 1276 S 500 W ELEVATIONS SIDE
AJR Atelier Jörg Rügemer expressly reserves its common law copyright and other project rights in these 125 PARKVIEW PLACE SALT LAKE CITY, UT 84107
APPROVED BY
02 12/07/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 08 05/16/16 Reworking plans, elevations, section to new roof lines 28'-4"
plans. These plans are not to be reproduced, changed, or copied in any form or manner whatsoever, nor are
they to be assigned to a third party without first obtaining the written permission and consent of AJR Atelier 03 12/20/15 PC Site Plan adjustments, plans, sections, elevation adjustment to site plan 09 08/08/16 Prep plans for re-submittal PARK CITY, UT 84098 ED BLAKE OTHER APPROVALS
Jörg Rügemer. In the event of unauthorized reuse of these plans by a third party, the third party shall hold
(435) 214 6721 (435) 214-6721 (801) 263-0136
SIZE CAGE CODE DRAWING NO. REV
04 02/15/16 Guest Parking extension to 22’, detail for drain between pitched roofs
AJR Atelier Jörg Rügemer harmless.
c 2015-2016 AJR Atelier Jörg Rügemer 05 03/01/16 Basement Option for duplex, redesign of unit and exterior spaces joerg@ruegemer.com ed@habitatsaltlake.com CAD FILE NAME A 13
06 03/16/16 Update with Planning Commission Requirements, see additional Notes 24'-2"
SCALE 1/4"=1'-0" EST. WGT SHEET OF
1 2 3 4 5