3 # 16 MM Ø AT COLUMN

2" EXTENSION SIDE FACES


REMOVE THE CONCRETE PROPOSED COLUMN
COVER IN EXISTING COLUMN EXTENSION WITH 2" EXTRA
AT BOTH SIDES COVER IN ALL AROUND

8mm Ø @ 6" C/C TIES PROPOSED FOUNDATION


WITH 1' DEPTH

1'
LAP THE COLUMN ROD FOR
FULL LENGTH FOUNDATION

6" 6" D
EXISTING FOUNDATION
EXISTING P.C.C
EXISTING SAND FILLING
Section A-A