Professional Documents
Culture Documents
Cryo-Systems
C RY O - S Y S T E MS
www.cryotherm.de
EN
LIN Nitrogen Vessels
BIOSAFE®-Rack-Systems
Transport Refrigeration
for Vehicles
Customising / Turn-Key-Solutions
Cryo-Cooler / Cooling Baths
Accessories
Service
About Us
1
APOLLO®
Vacuum Super-Insulated Storage and Transport Vessel 6-7
(50 - 350 l)
JUNO®
Vacuum Super-Insulated Storage and Transport Vessel 8-9
(25 l)
SIRIUS®
Vacuum Super-Insulated Storage Vessel 10 - 11
(1,000 - 2,000 l)
SATURN®
Vacuum Super-Insulated Storage and Transport Vessel 12 - 13
with π Label (50 - 300 l)
MERKUR®
Tank for Truck Transport of Cryogenic Liquid Gases 14 - 15
on Public Roads (500 - 3,000 l)
STELLA®
The Robust Working Dewar for Use with Liquid Nitrogen 16 - 17
(0.5 - 10,000 l)
LAB
Easy to Handle Storage and Transport Dewars for Laboratory Use 18 - 19
(4 - 50 l)
CRYO LC® 20 - 21
Level Control Device
4 5
1
APOLLO®-Series
LIN LAR LOX Reliable, Safe and Durable Rapid Cold at the Point of Use
Options:
Convincing advantages:
• efficient exhaust cooling system
• pressure build-up regulator
• low evaporation rate (only 0.6%/day with • pressure reduction regulator
APOLLO® 200) • double extraction liquid side
• robust transport frame
• double extraction gas side
• compact dimensions
• integrated vacuum seal-off and safety • triple extraction liquid side
device • triple extraction gas side
• long-term vacuum protection by means of
• level indicator, capacitive, battery
high-grade adsorption and getter materials
• optimised super-insulation by means • level indicator, capacitive, 4-20 mA
of multi-layered vacuum insulation and • forklift pockets
computer optimised thermodynamic
construction • set of castors anti-magnetic
• inner and outer vessels tested separately by • cryo-protective equipment, full set
helium leak test
• robust construction made of highly Further special options on request
corrosion-resistant cryogenic stainless steel
• smooth-running, sturdy castors Technical Data
• low maintenance requirements APOLLO® 50 APOLLO® 100 APOLLO® 150 APOLLO® 200 APOLLO® 350
Vessel Name
1.3 bar 1.3 bar 1.3 bar 2.0 bar 2.0 bar
• wide range of accessories
vessel material stainless steel stainless steel stainless steel stainless steel stainless steel
approval mark CE CE CE CE0035 CE0035
Standard Features: Storage and transport vessel for
geometrical capacity [l] 49.5 99.2 149.5 198.5 348
• integrated safety device at the vessel neck cryogenic liquid nitrogen. With operating overpressure,
vacuum super-insulation and [bar] 1.3 1.3 1.3 2.0 2.0
max.
• vacuum seal-off and safety device
long-term vacuum protection. weight empty [kg] 44 62 79 100 160
• smooth-running, sturdy castors and transport frame Approved according to weight full LIN [kg] 85 145 204 266 450
• pressure indicator European Pressure Equipment stat. evaporation rate LIN [%/day] 2 1.2 1 0.6 0.5
• level indicator Directive PED. Transport in total height A [cm] 80 114 146 117 165
• EK-siphon with exhaust and overflow valve unpressurised condition with
diameter outer D [cm] 50 50 50 70 70
inserted transport plug.
• integrated pressure build-up total width C [cm] 65 65 65 80 80
• decanting hose (1.5 m) with phase separator depth of immersion B [mm] 58.5 92 122 91 135
• transport plug castor diameter F [mm] 125 125 125 160 160
• cold-protection gloves and safety glasses with side protection neck diameter E [mm] 50 50 50 50 50
siphon connection KF 50 KF 50 KF 50 KF 50 KF 50
article-no. LIN 78202700 78202701 78202702 78202748 78202749
article-no. LAR 78202700/AR 78202701/AR - - -
article-no. LOX 78200520 78202701/O2 78202702/O2 - -
6 7
1
JUNO® 30
Options:
Convincing advantages:
• efficient exhaust cooling system • roller base
• compact dimensions • EK-siphon with exhaust and overflow valve
• integrated vacuum seal-off and safety • decanting hose (1.5 m)
device
• robust construction made of highly
• phase separator
corrosion-resistant cryogenic stainless steel
• long-term vacuum protection by means of Further special options on request
high-grade adsorption and getter materials
• optimised super-insulation by means
of multi-layered vacuum insulation and
computer optimised thermodynamic
construction
• inner and outer vessels tested separately
by helium leak test
• wide range of accessories
8 9
1
SIRIUS®-Series
Standard Features:
• integrated level indicator
Vacuum Super-Insulated
• vacuum super-insulated liquid extraction valve with plug-in Cryo-Supply Vessel for
coupling DN14 male for connection to a fixed transfer line
Cryogenic Liquid Nitrogen. Technical Data
• automatic pressure build-up with adjustable pressure control Vessel Name SIRIUS® 1000 SIRIUS® 2000
Suitable for installation in out-
valve vessel material stainless steel stainless steel
door areas – with closed and
• adjustable overflow valve for maximum pressure regulator lockable instrument geometrical capacity [l] 995 2,224
• separate filling port with shut-off valve cabinet. Manufacture according
operating overpressure, max. [bar] 3 3
• MG97 safety device against pressure excess during filling to European Pressure Equip-
ment Directive with CE-mark. weight empty [kg] 570 1,100
• pressure gauge and safety valve
weight full [kg] 1,330 2,700
• level indicator with limit switch for connection to alarm system
stat. evaporation rate [%/day] 1 0.9
• large exhaust/overflow line for fast filling via LIN-service
• crane eyes and forklift pockets lengthwise and crosswise for easy total length L [mm] 2,400 3,100
10 11
1
SATURN®-Series
Options:
Convincing advantages:
• efficient exhaust cooling system
• pressure build-up regulator
• low evaporation rate (only 1.2%/day with • pressure reduction regulator
SATURN® 150) • forklift pockets
• robust transport frame
• level indicator, capacitive, battery
• compact dimensions
• integrated vacuum seal-off and safety • level indicator, capacitive, 4-20 mA
device • set of castors anti-magnetic
• long-term vacuum protection by means of
• cryo-protective equipments, full set
high-grade adsorption and getter m
aterials
• optimised super-insulation by means
of multi-layered vacuum insulation and Further special options on request
computer optimised thermodynamic
construction
• inner and outer vessels tested separately by
helium leak test
• robust construction made of highly
Technical Data
corrosion-resistant cryogenic stainless steel
Vessel Name SATURN® 50 SATURN® 100 SATURN® 150
• smooth-running, sturdy castors
• low maintenance requirements vessel material stainless steel stainless steel stainless steel
• wide range of accessories approval mark π π π
geometrical capacity [l] 52 104 157
operating overpressure, max. [bar] 3.0 3.0 3.0
Standard Features: Transport vessels for demand-
ing transport of cryogenic weight empty [kg] 58 86 93
• integrated safety device at the vessel neck
liquid nitrogen (and argon) with weight full [kg] 98 156 214
• vacuum seal-off and safety device
vacuum super-insulation and stat. evaporation rate LIN [%/day] 2.4 1.5 1.2
• smooth-running, sturdy castors and transport frame long-term vacuum protection. total height A [mm] 845 1,180 1,520
• pressure indicator Approved as: Transportable diameter outer D [mm] 500 500 500
• level indicator Pressure Equipment Directive total width C [mm] 680 680 680
• EK-siphon with exhaust and overflow valve TPED (cryo-vessel) in accord- immersion depth B [mm] 585 920 1,260
• integrated pressure build-up ance to Directive 2010/35/EU castor diameter F [mm] 160 160 160
ADR/RID.
• decanting hose (1.5 m) with phase separator neck pipe diameter E [mm] 50 50 50
• cold-protection gloves and safety glasses with side protection siphon connection KF 50 KF 50 KF 50
article-no. 78207805 78207806 78207807
12 13
1
MERKUR®-Series
Ideal for Transporting Cryogenic Gases
Truck Transport
LIN LOX LAR for the Most Varied Applications in Research, Medicine
of Cryogenic Liquid Gases
and Industry
Rail (ADR/RID) with test certifi- regulator (1-6 bar) 3 level indicator
Standard Features: 6 6 6
4 pressure indicator
cate of the German Inspection • maximum pressure 7 4
• integrated level and pressure indicator 5 analysis valve
(TÜV). regulator (1-4 bar) 3
6 safety valve
• pressure build-up 8 2
• mounting kit for service 7 trycock
• filling, liquid extraction valve vehicle 8 purge valve
1
9 pressure build-up system
• analysis valve • condensate drip tray filling 10 vacuum seal-off and
port pressure build-up safety device
• purge valve 9
evaporator
14 15
1
STELLA®-Series
Options:
Convincing advantages:
• integrated vacuum seal-off and safety
We will gladly manufacture your individually designed dewar
device to the exact dimensions you require.
• long-term vacuum protection by means of Accessories, for example,
high-grade adsorption and getter materials
• roller base
• optimised super-insulation by means
of multi-layered vacuum insulation and • outlet below
computer optimised thermodynamic
• level indicator
construction
• robust construction made of stainless steel • etc.
• low maintenance requirement
• wide range of accessories Simply get in touch with us
Technical Data
STELLA® STELLA® D
Dewar Name
65/180 85/205 100/285 185/270 250/450 300/750 400/500
geometrical capacity [l] 0.6 1.16 2.23 7.25 22.1 53 62.8
outer height [mm] 203 231 312 300 570 870 620
The STELLA®-Series is a robust range of vacuum insulated dewars for
using liquid nitrogen. inner height [mm] 180 206 285 270 450 750 500
16 17
1
LAB-Series
Options:
Convincing advantages:
• simple, sturdy design
• filling / extraction hose
• reinforced neck opening reduces nitrogen • phase separator
loss by evaporation • dipper
• progressive chemical technology for
long-term retention of the vacuum • manual discharge device
• multi-layered vacuum insulation by means • pouring spout
of computer optimised thermodynamic
• substitute pipe plug
construction
• inner and outer dewars tested separately by • castors
helium leak test
• robust construction made of stainless steel
• high-performance insulation for the lowest
possible loss due to evaporation
18 19
1
CRYO LC® (Level Control)
Application
Convincing advantages:
• modular design
CRYO LC® can be used in vessels and systems of all sizes in which the
• quick assembly
level sensor can be equipped.
• easy operation The device can be installed in various ways:
• individually customised level control and • compact devices, ready for operation, in cabinet with display and
level sensor, dependent on application and operation unit
customer requirements
• for installation in control cabinet or as a • installation in cabinets, modular, CRYO LC® basic module for
separate, independent device assembly on C-tracks, display and operation unit with flat ribbon
• measurement and control are cable ready for installation in the switch cabinet door
independent of pressure as
• installation in cabinets, modular, CRYO LC® basic module for
measurements are taken against a
reference sensor assembly on C-tracks, without display and operation unit, control
• basic module can be operated at the same and signal retrieval can be carried out directly by means of SPS
time with at least two display and operation • two display and operation units attached to one CRYO LC® basic
units (local and remote control)
module (local and remote control)
• trigger guard against manipulation and
operator error / device only runs in auto-
matic mode if the reference sensor is colder
than approximately -100 °C Level Detection: Level Control: Further Functions:
• level monitors itself as the sensors are Level detection is effected by The level is automatically con- • collective filling
monitored for wire breakage and short four sensors. trolled between LEVEL 2 and
circuit • “MANUAL FILL“
At the lowest point of the level LEVEL 3. Fall below of LEVEL 2
CRYO LC® • each signal (LEVEL 1-4, filling, alarm) is du- • “START AUTOFILL“
plicated by means of a change-over contact sensor there is a fifth PT sen- a potential free change-over
Device for level detection and level control in vessels and systems. • “AUTO FILL ON/OFF“
• potential-free change-over contact: high sor as a reference sensor. Only contact will trigger on the basic
CRYO LC® operates independent of pressure. performance switch (230/VAC/3A), thus module and solenoid valve will • monitoring of the sensors
when this sensor registers a
external devices can be directly controlled be opened. If the level reaches for wire breakage and short
System via this feature
temperature of under approx.
LEVEL 3 the change-over con- circuiting
CRYO LC® consists of the basic module as a built-in device for -100 °C will the level detection
• SPS-compatible interface
be activated. tact will be triggered again
C-tracks with a level sensor manufactured to customer requirements, • flexible current supply in wide ranges
and the solenoid valve will
the display and operation unit (optional components) as well as the (85-264 VAC and 24V DC) The conditions LEVEL 1 to
be closed. The filling process
cabinet. LEVEL 4 are displayed on the
shown on the display and oper-
panel and operation unit and
Functions are retrievable via the potential
ating unit as “FILL”. The function
Level detection: detection of 4 levels (LEVEL 1 to LEVEL 4), can be switched on and off us-
free change-over contact. An
display and signal output (= potential free change-over contact) plus ing the buttons “AUTOFILL ON”
exceeding of LEVEL 4 or fall be-
and “AUTOFILL OFF”.
level control: automatic control of the level between LEVEL 2 and low LEVEL 1 result in an alarm
LEVEL 3.
Application Examples: (optically and acoustically at the
• phase separator display and operating unit or via
In both functions there is an alarm if LEVEL 1 is underrun. Also on Various sensors
exceeding of LEVEL 4 or sensor short circuit as well as sensor wire • dewars/cryostats the potential free change-over
breakage. • cooling baths contact at the basic module).
20 21
2
BIOSAFE -Systems
®
LIN Liquid Nitrogen
-196 °C
Life Science
BIOSAFE®-Systems
Long-Term Storage
of Biological and Medicinal Samples (120 - 1,400 l) 24 - 29
BIOSAFE-CONTROL ß ®
CRYO MESSENGER® 30 - 31
Remote Superordinate Control System
BIOSAFE® CRYOSHIPPER-SERIES 32 - 33
BIOSAFE® X/S-SERIES 34 - 35
Vessels for Storage of Biological Samples
STELLA®
The Robust Dewar Vessels for Using Liquid Nitrogen 36 - 37
(0.5 - 10,000 l)
22 23
BIOSAFE®-System
2
Systems Tailor-Made to Your Needs –
Optimal Storage of Samples
LIN for Needs-Based Cryo-Technology.
Safety Needs a System
A Complete System – Safety for Certain
BIOSAFE® MD ß – Cryoconservation by means of Cryotherm offers you a com- • the orderly, safe packing For you we will find the
cryogenic liquid nitrogen has Convincing advantages: plete solution for your cryo- and filing of samples by optimum solution!
BIOSAFE® SC ß – now with
become a proven and reliable • full storage capacity on gas phase storage conservation requirements with means of the BIOSAFE® rack For you we will construct the
-180 °C during gas p hase
practice in science, research, • the nitrogen reserve under the platform various sizes and models of system optimum Cryo-network!
storage! Our product
medicine, ecological research is sufficient for up to two weeks BIOSAFE®, supplemented with a • remote monitoring of your
range BIOSAFE® MD ß dependent on the size of vessel samples by means of the re-
and technology Safe cold down a wide range of accessories:
and BIOSAFE® SC ß were • redundant hardware for s oftware mote control system CRYO-
to -180°C in the gas phase and • controlled and programmed
developed especially independent monitoring of mini- MESSENGER®
the inert atmosphere enable mum and maximum alarm cooling down of your
for c ryogenic long-term unproblematic freezing and samples in controlled rate
storage of medical and • low temperatures of -180 °C
storage of valuable medical and freezers
whether in small or large vessels
biological material in biological samples and material. and whether in wide-necked v essels • administration and s ecurity
laboratories or vessels with a carousel system of your sample data by
• service for comissioning and means of the sample
BIOSAFE by Cryotherm has
® Our BIOSAFE® Range execution of qualification (IQ/OQ) management system
been associated with quality consists of: • remote diagnosis and remote • a supply system optimised
• CHRONOS® cryogenic stor- monitoring (optional) for your requirements of
and safety for quite some time.
cryogenic liquid nitrogen via
Experience, the technology age vessels for freezing and
the APOLLO® supply vessel.
and our know-how make it an storing
BIOSAFE® SC ß • or directly supplied via a
easy decision for you to go with • BIOSAFE-CONTROL ß the
®
is the model for research, medi- super-insulated transfer line
BIOSAFE®. level controller device and
cine and the environment when
vessel superordinate control
the samples stored are not to
system for reliable supply of
be returned to the human body.
cryogenic liquid nitrogen.
BIOSAFE® MD ß
is approved according to APOLLO®- BIOSAFE®-
directive 93/42/EEC on medical controlled rate freezers supply vessels rack systems
by Planer
product as medical products
class IIa. With this medical
product cell and tissue samples
stored long-term cryogenically sample administration and super-insulated CRYO-MESSENGER®
for return to the human body sample-management-system transfer lines remote superordinate control
system
by using cryogenic liquid nitro-
gen as the cooling agent.
24 25
From Cryopreservation in the Laboratory
2
Up to a Large Area Cryobank:
BIOSAFE® 120/220/420 MD ß
LIN BIOSAFE® 500/600/1000/1400 MD ß
BIOSAFE® 120/220/420 SC ß
BIOSAFE® 500/600/1000/1400 SC ß
26 27
BIOSAFE® Overview BIOSAFE-CONTROL® ß
With BIOSAFE® 40 SC ß and BIOSAFE® 60 SC ß 2
Cryotherm Offers Small, Highly Efficient Long-Term
Storage Vessels for Small Sample Quantities. Integrated Level Control and Vessel Monitoring
LIN Both Systems are Equipped with the Level for Safe Long-Term Storage
Controller and Vessel Superordinate
Control System BIOSAFE-CONTROL® ß
28 29
CRYO-MESSENGER®
2
Convincing advantages:
BIOSAFE® with
CRYO-MESSENGER® • redundant cryobank monitoring
• easiest operation via
www.cryo-messenger.de
• transfer of alarm signals and logged
temperatures via e-mail, SMS or FAX
• quick assembly
30 31
BIOSAFE® CRYOSHIPPER-Series
2
Sample Transport in Liquid Nitrogen
LIN
at -150 °C
Options:
Convincing advantages:
• transport protective packag-
• simple, sturdy design
ing
• GFK neck pipe for reduction of
nitrogen loss through evaporation • canister
• secure against leakage by means • substitute neck pipe plug
of hydrophobic absorbent • cryoshipper VSS has been
• progressive technology for long- independently tested of
term vacuum protection
other models of the UN and
• robust aluminium construction IATA and has been inde-
• high-performance insulation for the pendently approved. When
lowest possible losses due to evaporation
using the appropriate ac-
• all models have been approved for non- cessories you are allowed to • cryoshipper blood bag
infectious material in air transport use
ship infectious material. frame
Technical Data
Vessel Name SC 2/1 V Mini-Moover SC 4/2 V SC 4/3 V Cryoshipper Cryo-Moover Cryoshipper VSS
no. of canisters 1 1 1 1 1 rack 7 1 rack
geometrical capacity [l] 1.5 2.9 3.6 4.3 8.5 4.2 11.8
stat. evaporation rate [l/d] 0.19 0.20 0.26 0.20 0.85 0.35 0.8
32 33
BIOSAFE® X/S-Series
2
Easy-To-Handle Storage Vessels
LIN Storage Vessels for Biological Samples
for Use in Laboratories
Options:
Convincing advantages:
• filling hose • manual discharge device
• simple, sturdy design
• phase separator • substitute neck pipe plug
• GFK neck pipe for reduction of
nitrogen loss through evaporation • dipper • rollers
• progressive technology for long-
term vacuum protection
Technical Data BIOSAFE® X
• inner and outer vessel each
Vessel Name X 20/20 X 21/6 X 22/5 X 32/8 X 33/22 X 34/18 X 35/12 X 43/28 X 47/11-6SQ X 41/11-6 X 47/11-10
separately by helium leak test
no. of canisters 6 9 6 9 6 6 10 6 6 6 10
• robust aluminium construction geometrical capacity [l] 20.5 21 22.4 32 33.4 34.8 34.8 42.2 47.4 47.4 47.4
• high-performance insulation for the stat. evaporation rate [l/d] 0.09 0.25 0.35 0.35 0.14 0.18 0.24 0.14 0.39 0.39 0.39
lowest possible losses due to evaporation normal time span [day] 140 53 40 57 154 123 90 193 75 75 75
neck opening [mm] 55.4 89 97 97 70 89 102 70 127 127 127
total height [mm] 652 438 559 546 660 675 635 670 673 673 673
diameter outer [mm] 368 484 368 464 464 464 456 508 508 508 508
canister height [mm] 279 127 279 279 279 279 279 279 279 279 279
canister diameter [mm] 41.9 70 79 67 56 71 66 56 102 102 71
fixture with cladding pipe storage of 30
18 straws 78 90 48 72 90 48 114 120
for vials (art-no. 0791004) cryoboxes*
vials 2 ml 90 - 390 450 240 360 450 240 750 570 600
vials 5 ml 54 - 234 270 144 216 270 144 - 342 360
weight empty [kg] 11.8 26.9 11.6 13.6 15.4 15.4 15.4 16.4 16.4 16.4 16.4
weight full [kg] 28.3 28.3 30 39.5 42.5 43.5 43.1 50.5 54.6 54.6 54.6
article-no. 78210021 78400458 78400417 78400418 78400224 78210022 - 78400411 78400680 78400065 78400407
34 35
STELLA®-Series
2
For Frosting Components and
LIN Working Dewar for Liquid Nitrogen
Biological Materials
Options:
Convincing advantages:
• integrated vacuum seal-off and safety
We will gladly manufacture your individually designed dewar
device to the exact dimensions you require.
• long-term vacuum protection by means of Accessories, for example,
high-grade adsorption and getter materials
• roller base
• optimised super-insulation by means
of multi-layered vacuum insulation and • outlet below
computer optimised thermodynamic
• level indicator
construction
• robust construction made of stainless steel • etc.
• low maintenance requirement
• wide range of accessories Simply get in touch with us
Technical Data
STELLA® STELLA® D
Dewar Name
65/180 85/205 100/285 185/270 250/450 300/750 400/500
geometrical capacity [l] 0.6 1.16 2.23 7.25 22.1 53 62.8
outer height [mm] 203 231 312 300 570 870 620
The STELLA®-Series is a robust range of vacuum insulated dewars for
using liquid nitrogen. inner height [mm] 180 206 285 270 450 750 500
36 37
Controlled Rate Freezers Easy Operation
2
Programmable Complete Systems
For a Safe System
for Cryopreservation
Kryo 360-3.3, Kryo 560-16 MRV-Programmer for Kryo The system has been equipped
and Kryo 750-30 360-3.3 and Kryo 560-16 with numerous safety elements
that protect the device from
The controlled rate freezers The MRV-Programmer enables
power loss or PC crash d uring
Kryo 360-3.3, Kryo 560-16 varied protocols and is still easy
operation. Processor and
and Kryo 750-30 unify all the to programme and to o perate.
system problems are monitored
important characteristics During and after a run an
and independently the system
which are expected of a first- extensive range of information
carries out an automatic re-
class freezing equipments is displayed which is available in
start to protect the samples.
for biological m
aterials. The alphanumeric or graphic form
Convincing advantages:
final t emperature of -180 °C on the clearly structured screen For example all control and data
ensures physical integrity or the data can be printed out systems are separate from each • unlimited freezing profiles
during transport to the storage on the integrated full screen other and the c ontroller can • graphic data in real-time
location. Due to its flexibility the printer. be removed from the freezing • graphic data after processing
chamber in operation without of the programme
system is ideal for the complex The validation was given high
and demanding protocols any loss of programme integ- • traceability
priority. The MRV-Programmer
that are found in the newest rity. Storage of data and pro- • password protection
offers a password controlled
techniques of c ryopreservation. cessing of the programme are • commentary before and after
access to several operating
executed in isolated e lectronic processing of the programme
The sample capacity of the levels, date and time stamps,
systems which are completely
system also fulfils the require- programme preview and check
independent of each other.
ments of laboratories that are before a run and s torage of
working to full capacity and the data for the last 5 runs for
compact as well as highly up- subsequent printing. User DeltaT® PC Software for
Convincing advantages:
to-date form adds an increase calibration and creation of the Controlled Rate Freezers
in efficiency to even the most • High-level of reliability appropriate paper printouts DeltaT® supports the PC-in-
modern facility. • horizontal or vertical freezing belong to the functional scope. terface on the controlled rate
• validation – stable results A PC-connection which is com- freezers. This enables quick
• safety by means of extended patible with the comprehensive development and maintenance
preservation period DeltaT® Software belongs to the of profiles (freezing curves) on
• diverse protocols - flexible standard package. your PC and observation of the
• space saving through compact design freezing process in real-time on
• user friendly through sim- the PC.
ple menu structure
DeltaT® can be used to store
The controlled rate freezer • freezing of vials and straws DeltaT®
data on your PC (the possible
(Kryo 360-3.3) create profiles yes
fulfill the directive 93/42/EU on scope depends solely on the
• freezing of vials, straws and Article-no. Controlled Rate Freezer run profiles yes
medical products. bags (Kryo 560-16) size of your hard drive) as well
78213715 Kryo 360-3.3 MD view Kryo-data yes as to print the data on a stand-
They are delivered with the • directed laminar flow for efficient and 78213716 Kryo 560-16 MD print Kryo-data yes
even cooling down (Kryo 560-16) ard printer for your manual
software DeltaT®. 78213717 Kryo 750-30 MD export Kryo-data yes documentation.
38 39
Kryo 360-3.3 and Kryo 560-16
2
40 41
2
For Programme Regulated
Technical Data
Cryopreservation
The controlled rate freezer Kryo demands can be fulfilled. Specifications Outer Inner
PC Software: the controlled rate freezers are supplied
750-30 is a unique integrated Convincing advantages: with the Software DeltaT®.
Protocols can be triggered height 55 cm 26 cm
42 43
3
BIOSAFE®
LIN Liquid Nitrogen
Rack-Systems
-196 °C
Introduction 46 - 49
Rack Systems for Every Area of Use
Rack-Number Sets 66
Customisation 67
44 45
Cryotherm Rack-Systems
Goblets
Cassettes for Straws
for Bags
46 47
Cryotherm Rack-Systems
Biological Samples Optimally Stored:
• Vials / Cryotubes
Simple, Flexible and with a System
• Freezing Bags
• Straws
3
are a large number of diverse sam- Another strong point of this mate- execution of qualification (IQ/
ple packages by various manufac- rial is its low weight and easier OQ)
details!
Cryo
vessels
48 49
Stored Safely
Rack numbers
individually attachable
for clarity of storage
Double locking
of the drawers, cryoboxes and SBS racks
against inadvertent falling out
50 51
Storage Capacity BIOSAFE® 120-220-420
a) b) Rack of aluminium with c) d) Rack of aluminium with e) f) Rack of aluminium with g) h) Rack of aluminium with
10 levels for vials 5 levels for vials 10 levels for vials 5 levels for vials
and pivoting drawer bar and pivoting drawer bar and pivoting drawer bar and pivoting drawer bar
for the storage of for the storage of for the storage of for the storage of
a) 2 ml vials in drawers c) 5 ml vials in drawers e) 2 ml vials in g) 5 ml vials in
with grid with grid cryoboxes cryoboxes
dimensions (HxWxD): dimensions (HxWxD): dimensions (HxWxD): dimensions (HxWxD):
620 x 140 x 166 mm 620 x 140 x 166 mm 620 x 140 x 145 mm 620 x 140 x 145 mm
b) 2 ml vials in drawers d) 5 ml vials in drawers f) 2 ml vials in h) 5 ml vials in
with grid with grid cryoboxes drawers with grid
dimensions (HxWxD): dimensions (HxWxD): dimensions (HxWxD): dimensions (HxWxD):
620 x 85 x 85 mm 620 x 85 x 85 mm 620 x 85 x 85 mm 620 x 85 x 85 mm
BIOSAFE® 120 BIOSAFE® 220 BIOSAFE® 420 BIOSAFE® 120 BIOSAFE® 220 BIOSAFE® 420
1 2 3 4 5 6
52 53
Storage Capacity BIOSAFE® 120-220-420
Freezing bag rack a) b) Freezing bag rack of c) d) e) Freezing bag f) g) Freezing bag rack of aluminium
of aluminium with aluminium with 10 levels rack of aluminium with pivoting drawer bar
32 levels c) with 4 levels 620 x f) with 10 levels, 2 ml vials in drawers
and pivoting drawer bar
dimensions (HxWxD): for the storage of 80 x 280 mm with grid
575 x 95 x 165 mm d) with 4 levels 620 x 85 x 85 mm
2 ml vials in drawers with
620 x 80 x 285 mm g) with 5 levels, 5 ml vials in drawers
grid
e) with 3 levels with grid
dimensions (HxWxD): 580 x 80 x 305 mm 620 x 85 x 85 mm
620 x 85 x 85 mm
Freezing Bags in Cassettes Dimensions BIOSAFE® 120 BIOSAFE® 220 BIOSAFE® 420
(H x W x D) Article-No. Layout
Description [mm] Capacity Capacity Capacity
c) rack freezing bags in 4 levels, 4 x 3 double sections 620 x 80 x 280 78202831 10, 11, 12 6 10 20
plus: cassette for freezing bags 4R9955, 4R9953, CryoMACS 500 270 x 140 x 12 77031488 144 240 480
d) rack freezing bags in 4 levels, 4 x 5 single sections 620 x 80 x 285 78213389 10, 11, 12 6 10 20
plus: cassette for freezing bags 4R9955, 4R9953, CryoMACS 500 270 x 140 x 12 77031488 120 200 400
f) rack for 2 ml vials 25 per level, 10 levels 620 x 85 x 85 78202835 10, 11, 12 2 4 2
g) rack for 5 ml vials 25 per level, 5 levels 620 x 85 x 85 78202836 10, 11, 12 2 4 2
maximum storage capacity for freezing bags 4R9955, 4R9953, CryoMACS 500 144 240 480
plus: maximum storage capacity for 2 ml vials Ø 12 mm 500 1,500 500
e) rack freezing bags in 3 levels, for 15 pcs Hemofreeze type Z 2003 / DF 700 580 x 80 x 305 78202832 13, 14, 15 5 10 18
Dimensions plus: cassette for freezing bags Hemofreeze type Z 2003 / DF 700 300 x 160 x 12 77031509 75 150 270
Freezing Bags in Cassettes BIOSAFE® 120 BIOSAFE® 220 BIOSAFE® 420 f) rack for 2ml vials 25 per level 10 levels 620 x 85 x 85 78202835 13, 14, 15 3 2 2
(H x W x D) Article-No. Layout
Description [mm] Capacity Capacity Capacity
g) rack for 5ml vials 25 per level 5 levels 620 x 85 x 85 78202836 13, 14, 15 3 2 2
a) rack freezing bags in 32 levels 575 x 95 x 165 77031511 7, 8, 9 9 16 26 maximum storage capacity for freezing bags Hemofreeze type Z 2003 / DF 700 75 150 270
plus: cassette for freezing bags 4R9951, CryoMACS 50 161 x 85 x 12 77031514 288 512 832 plus: maximum storage capacity for 2 ml vials Ø 12 mm 750 500 500
b) rack for 2 ml vials, 25 per level, 10 levels 620 x 85 x 85 78202835 9 --- --- 6
or: rack for 5 ml vials, 25 per level, 5 levels 620 x 85 x 85 78202836 9 --- --- 6
BIOSAFE® 120 BIOSAFE® 220 BIOSAFE® 420
maximum storage capacity for freezing bags 4R9951, CryoMACS 50 288 512 832
plus: maximum storage capacity for 2 ml vials Ø 12 mm --- --- 1,500
10 11 12
7 8 9 13 14 15
54 55
Storage Capacity BIOSAFE® 120-220-420
SBS Racks (127.76x85.48) in Racks Without Pivoting Drawer Bars Straws in Canisters Dimensions BIOSAFE® BIOSAFE® BIOSAFE®
Dimensions BIOSAFE® BIOSAFE® BIOSAFE®
or Spring Clips in Each Level or Level and Pivoting Drawer Bars (Ø x H) Article-No. Layout 120 220 420
(H x W x D) Article-No. Layout 120 220 420 Description
[mm] [mm] Capacity Capacity Capacity
Description Capacity Capacity Capacity
a) canister for goblets with lifter, 620 mm high, max. 4 goblets Ø 70 x 620 78213016 22, 23, 24 38 63 110
a) rack for SBS racks (20-30 mm high), 19 levels without locking 620 x 89 x 130 * 16, 17, 18 11 20 40
plus: b) goblet diameter 65 mm, 120 mm high Ø 65 x 120 78212792 152 252 440
rack for SBS racks (30-40 mm high), 14 levels without locking 620 x 89 x 130 * 16, 17, 18 11 20 40
maximum storage capacity for straws 0.25 ml 85,120 141,120 246,400
rack for SBS racks (40-62 mm high), 9 levels without locking 620 x 89 x 130 * 16, 17, 18 11 20 40
maximum storage capacity for straws 0.5 ml 31,920 52,920 92,400
b) rack for SBS racks (20-30 mm high), 19 levels with spring clips 620 x 89 x 130 * 16, 17, 18 11 20 40
rack for SBS racks (30-40 mm high), 14 levels with spring clips 620 x 89 x 130 * 16, 17, 18 11 20 40 Explanatory note: 1 goblet (Ø 65 x 120 mm) contains max. 560 pieces 0.25 ml straws or max. 210 pieces 0.5 ml straws
rack for SBS racks (40-62 mm high), 9 levels with spring clips 620 x 89 x 130 * 16, 17, 18 11 20 40
c) rack for SBS racks (20-30 mm high), 16 levels with pivoting drawer bar 620 x 89 x 145 * 19, 20, 21 10 18 34
rack for SBS racks (30-40 mm high), 13 levels with pivoting drawer bar 620 x 89 x 145 * 19, 20, 21 10 18 34
rack for SBS racks (40-62 mm high), 9 levels with pivoting drawer bar 620 x 89 x 145 * 19, 20, 21 10 18 34
* on request
BIOSAFE® 120 BIOSAFE® 220 BIOSAFE® 420 BIOSAFE® 120 BIOSAFE® 220 BIOSAFE® 420
16 17 18 22 23 24
19 20 21
56 57
Storage Capacity BIOSAFE® 500-600-1000-1400
Storage in Drawers
Storage in Cryoboxes
Inside Height = 680, 800, 1100 mm
Inside Height = 680, 800, 1100 mm
Vials / Cryotubes with 2 ml: Racks with 12, 13, 18 Levels
Vials / Cryotubes with 2 ml: Racks with 12, 13, 18 Levels
Vials / Cryotubes with 5 ml: Racks with 6, 7, 10 Levels 3
Vials / Cryotubes in Drawers Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE® Vials / Cryotubes in Cryoboxes Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE®
(H x W x D) Article-No. Layout 500 600 1000 1400 (H x W x D) Article-No. Layout 500 600 1000 1400
Description [mm] Capacity Capacity Capacity Capacity Description [mm] Capacity Capacity Capacity Capacity
a) rack for 2 ml vials in drawers, 12 levels 727 x 140 x 166 78220222 26, 27 --- 24 34 --- e) rack for 2 ml vials in cryoboxes, 81/100, 12 levels 727 x 140 x 145 78215717 29, 30 --- 26 38 ---
rack for 2 ml vials in drawers, 13 levels 800 x 140 x 166 78214754 25 16 --- --- --- rack for 2 ml vials in cryoboxes, 81/100, 13 levels 800 x 140 x 145 78213935 28 16 --- --- ---
rack for 2 ml vials in drawers, 18 levels 1100 x 140 x 166 78221089 27 --- --- --- 34
rack for 2 ml vials in cryoboxes, 81/100, 18 levels 1100 x 140 x 145 78215718 30 --- --- --- 38
plus: drawer with grid for 2 ml vials, 120 pcs, Ø 12 mm 50 x 132 x 157 77031481 208 288 408 612
plus: drawer with grid for 2 ml vials, 80 pcs, Ø 14 mm 50 x 132 x 157 77031482 208 288 408 612 plus: cryobox grid 10x10 for 100 pcs 2 ml vials 53 x 132 x 132 78212859 208 312 456 684
b) rack for 2 ml vials 25 per level, 11 levels 680 x 85 x 85 78213481 26, 27 --- 4 8 --- or cryobox grid 9x9 for 81 pcs 2 ml vials 53 x 132 x 132 78214364 208 312 456 684
rack for 2 ml vials 25 per level, 13 levels 800 x 85 x 85 78214755 25 4 --- --- --- f) rack for 2 ml vials 25 per level, 11 levels 680 x 85 x 85 78213481 29, 30 --- 12 4 ---
rack for 2 ml vials 25 per level, 18 levels 1100 x 85 x 85 78221090 27 --- --- --- 8 rack for 2 ml vials 25 per level, 13 levels 800 x 85 x 85 78214755 28 6 --- --- ---
plus: drawer with grid for 25 pcs, 2 ml / 5 ml vials 50 x 75 x 75 78202839 52 44 88 144 rack for 2 ml vials 25 per level, 18 levels 1100 x 85 x 85 78221090 30 --- --- --- 4
or cryobox, grid 5x5 for 25 pcs, 2 ml vials 52 x 75 x 75 78212860 52 44 88 144
plus: drawer with grid for 25 pcs 2 ml / 5 ml vials 50 x 75 x 75 78202839 78 132 44 72
maximum storage capacity for 2 ml vials Ø 12 mm 26,260 35,660 51,160 77,040
or cryobox grid 5x5 for 25 pcs, 2 ml vials 52 x 75 x 75 78212860 78 132 44 72
c) rack for 5 ml vials in drawers 6 levels 680 x 140 x 166 77031480 26, 27 --- 24 34 ---
maximum storage capacity for 2 ml vials Ø 12 mm 22,750 32,100 46,700 70,200
rack for 5 ml vials in drawers 7 levels 800 x 140 x 166 78215713 25 16 --- --- ---
rack for 5 ml vials in drawers 10 levels 1100 x 140 x 166 78209913 27 --- --- --- 34
plus: drawer with grid for 5 ml vials 120 pcs, Ø 12 mm 100 x 132 x 157 77031483 112 144 204 340
or drawer with grid for 5 ml vials 80 pcs Ø 14 mm 100 x 132 x 157 77031484 112 144 204 340
d) rack for 5 ml vials 25 per level, 6 levels 680 x 85 x 85 78215714 26, 27 --- 4 8 --
rack for 5 ml vials 25 per level, 7 levels 800 x 85 x 85 78215715 25 4 --- --- ---
rack for 5 ml vials 25 per level, 10 levels 1100 x 85 x 85 78215716 27 --- --- --- 8
plus: drawer with grid for 25 pcs 2 ml / 5 ml vials 50 x 75 x 75 78202839 28 24 48 80
maximum storage capacity for 5 ml vials Ø 12 mm 14,140 17,880 25,680 42,800
BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400 BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400
25 26 27 28 29 30
58 59
Storage Capacity BIOSAFE® 500-600-1000-1400
Racks for Freezing Bags in Cassettes Racks for Freezing Bags in Cassettes
Freezing bag rack a) b) Freezing bag rack c) Freezing bag rack Freezing bag rack Freezing bag rack g) Freezing bag rack
of aluminium of aluminium of aluminium of aluminium of aluminium of aluminium
with 40 levels with 45 levels with 60 levels d) e) with 4 levels f) with 5 levels with 7 levels
dimensions (HxWxD): dimensions (HxWxD): dimensions (HxWxD): d) 4 x 3 double sections 5 x 2 double sections 7 x 3 double sections
715 x 95 x 165 mm 800 x 95 x 165 mm 1100 x 95 x 165 mm dimensions (HxWxD): dimensions (HxWxD): dimensions
620 x 80 x 280 mm 780 x 52 x 280 mm (HxWxD):
1100 x 80 x 280 mm
e) 4 x 5 single sections
dimensions (HxWxD):
620 x 80 x 285 mm
Freezing Bags in Cassettes Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE® Freezing Bags in Cassettes Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE®
(H x W x D) Article-No. Layout 500 600 1000 1400 (H x W x D) Article-No. Layout 500 600 1000 1400
Description [mm] Capacity Capacity Capacity Capacity Description [mm] Capacity Capacity Capacity Capacity
a) rack for freezing bags in 40 levels 715 x 95 x 165 78215708 32, 33 --- 36 52 --- d) rack for freezing bags in 4 levels 4 x 3 double sections 620 x 80 x 280 78202831 35, 36 --- 24 36 ---
b) rack for freezing bags in 45 levels 800 x 95 x 165 78215709 31 24 --- --- --- plus: cassette for freezing bags 4R9955, 4R9953, CryoMACS 500 270 x 140 x 12 77031488 --- 576 864 ---
c) rack for freezing bags in 60 levels 1100 x 95 x 165 78215710 33 --- --- --- 52 e) rack for freezing bags in 4 levels 4 x 5 single sections 620 x 80 x 285 78213389 --- 24 36 ---
plus: cassette for freezing bags 4R9951, CryoMACS 50 161 x 85 x 12 77031514 1,080 1,440 2,080 3,120 plus: cassette for freezing bags 4R9955, 4R9953, CryoMACS 500 270 x 140 x 12 77031488 --- 480 720 ---
rack for 2 ml vials 25 per level, 11 levels 680 x 85 x 85 78213481 --- 2 --- --- f) rack for freezing bags in 5 levels 5 x 2 double sections 780 x 52 x 280 78214757 34 24 --- --- ---
rack for 2 ml vials 25 per level, 13 levels 800 x 85 x 85 78214755 2 --- --- --- plus: cassette for freezing bags 4R9955, 4R9953, CryoMACS 500 270 x 140 x 12 77031488 480 --- --- ---
rack for 2 ml vials 25 per level, 18 levels 1100 x 85 x 85 78221090 --- --- --- --- g) rack for freezing bags in 7 levels 7 x 3 double sections 1100 x 80 x 280 78215711 36 --- --- --- 36
plus: drawer with grid for 25 pcs 2 ml / 5 ml vials 50 x 75 x 75 78202839 26 22 --- --- plus: cassette for freezing bags 4R9955, 4R9953, CryoMACS 500 270 x 140 x 12 77031488 --- --- --- 1,512
or cryobox grid 5x5 for 25 pcs, 2 ml vials 52 x 75 x 75 78212860 26 22 --- --- rack for 2 ml vials 25 per level, 11 levels 680 x 85 x 85 78213481 35, 36 --- 2 4 ---
maximum storage capacity for freezing bags 4R9951, CryoMACS 50 77031514 1,080 1,440 2,080 3,120 rack for 2 ml vials 25 per level, 13 levels 800 x 85 x 85 78214755 4 --- --- ---
plus: maximum storage capacity for 2 ml vials Ø 12 mm 650 550 --- --- rack for 2 ml vials 25 per level, 18 levels 1100 x 85 x 85 78221090 36 --- --- --- 4
plus: drawer with grid for 25 pcs 2 ml / 5 ml vials 50 x 75 x 75 78202839 52 22 44 72
or cryobox grid 5x5 for 25 pcs, 2 ml vials 52 x 75 x 75 78212860 52 22 44 72
max. storage capacity f. freezing p. 4R9955, 4R9953, CryoMACS 500 77031488 480 576 864 1,512
plus: maximum storage capacity for 2 ml vials Ø 12 mm 1,300 550 1,100 1,800
BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400 BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400
31 32 33 34 35 36
60 61
Storage Capacity BIOSAFE® 500-600-1000-1400
a) Freezing bag rack b) Freezing bag rack Racks of aluminium for SBS racks
of aluminium of aluminium a) without locking
with 2 levels with 3 levels 620 x 89 x 130 mm / 800 x 89 x 130 mm /
dimensions (HxWxD): dimensions (HxWxD): 1100 x 89 x 130 mm
680 x 140 x 166 mm 1100 x 140 x 166 mm b) with spring clips
620 x 89 x 130 mm / 800 x 89 x 130 mm /
1100 x 89 x 130 mm
SBS Racks (127.76 x 85.48) in Racks Without Locking or with Spring Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE®
Clips in Each Level or with Levels and Clamps Article-
(H x W x D) Layout 500 600 1000 1400
No.
Description [mm] Capacity Capacity Capacity Capacity
a) rack for SBS racks (20-30 mm high) 21 levels, without locking 680 x 89 x 130 * 38, 39 --- 48 72 ---
rack for SBS racks (30-40 mm high) 16 levels, without locking 680 x 89 x 130 * 38, 39 --- 48 72 ---
Freezing Bags in Cassettes Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE®
(H x W x D) Article-No. Layout 500 600 1000 1400 rack for SBS racks (40-62 mm high) 10 levels, without locking 680 x 89 x 130 * 38, 39 --- 48 72 ---
Description [mm] Capacity Capacity Capacity Capacity rack for SBS racks (20-30 mm high) 24 levels, without locking 800 x 89 x 130 * 37 30 --- --- ---
a) rack for freezing bags in 2 levels, 680 x 140 x 166 77031508 25, 26, 27 16 24 34 --- rack for SBS racks (30-40 mm high) 18 levels, without locking 800 x 89 x 130 * 37 30 --- --- ---
for 18 pcs Hemofreeze type Z 2003 rack for SBS racks (40-62 mm high) 12 levels, without locking 800 x 89 x 130 * 37 30 --- --- ---
b) rack for freezing bags in 3 levels, 1100 x 140 x 166 78215712 27 --- --- --- 34 rack for SBS racks (20-30 mm high) 12 levels, without locking 1100 x 89 x 130 * 39 --- --- --- 72
for 27 pcs Hemofreeze type Z 2003
rack for SBS racks (30-40 mm high) 26 levels, without locking 1100 x 89 x 130 * 39 --- --- --- 72
plus: cassette for freezing bags Hemofreeze type Z 2003 300 x 160 x 12 77031509 288 432 612 918
rack for SBS racks (40-62 mm high) 17 levels, without locking 1100 x 89 x 130 * 39 --- --- --- 72
rack for 2 ml vials 25 per level, 11 levels 680 x 85 x 85 78213481 26 -- 4 8 --
b) rack for SBS racks (20-30 mm high) 21 levels, with spring clips 680 x 89 x 130 * 38, 39 --- 48 72 ---
rack for 2 ml vials 25 per level, 13 levels 800 x 85 x 85 78214755 25 4 -- -- --
rack for SBS racks (30-40 mm high) 16 levels, with spring clips 680 x 89 x 130 * 38, 39 --- 48 72 ---
rack for 2 ml vials 25 per level, 17 levels 1100 x 85 x 85 78213385 27 -- -- -- 8
rack for SBS racks (40-62 mm high) 10 levels, with spring clips 680 x 89 x 130 * 38, 39 --- 48 72 ---
plus: drawer with grid for 25 pcs 2 ml / 5ml vials 50 x 75 x 75 78202839 52 44 88 144
rack for SBS racks (20-30 mm high) 24 levels, with spring clips 800 x 89 x 130 * 37 30 --- --- ---
or cryobox grid 5x5 for 25 pcs, 2 ml vials 52 x 75 x 75 78212860 52 44 88 144
rack for SBS racks (30-40 mm high) 18 levels, with spring clips 800 x 89 x 130 * 37 30 --- --- ---
maximum storage capacity f. freezing p. Hemofreeze type Z 2003 77031509 288 432 612 918
rack for SBS racks (40-62 mm high) 12 levels, with spring clips 800 x 89 x 130 * 37 30 --- --- ---
plus: maximum storage capacity for 2 ml vials Ø 12 mm 1,300 1,100 2,200 3,600
rack for SBS racks (20-30 mm high) 12 levels, with spring clips 1100 x 89 x 130 * 39 --- --- --- 72
rack for SBS racks (30-40 mm high) 26 levels, with spring clips 1100 x 89 x 130 * 39 --- --- --- 72
rack for SBS racks (40-62 mm high) 17 levels, with spring clips 1100 x 89 x 130 * 39 --- --- --- 72
* on request
BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400 BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400
25 26 27 37 38 39
62 63
Storage Capacity BIOSAFE® 500-600-1000-1400
SBS Racks (127.76 x 85.48) in Racks Without Locking Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE® Straws in Canisters Dimensions BIOSAFE® BIOSAFE® BIOSAFE® BIOSAFE®
or with Spring Clips in Each Level or with Levels and Clamps Article- (Ø x H) Article-No. Layout 500 600 1000 1400
(H x W x D) Layout 500 600 1000 1400 Description
No. [mm] Capacity Capacity Capacity Capacity
Description [mm] Capacity Capacity Capacity Capacity
a) canister for goblets with lifter 620 mm high, max. 4 goblets Ø 70 x 620 78213016 44, 45 --- 120 212 ---
c) rack for SBS racks (20-30 mm high), 18 levels, with pivoting drawer bar 680 x 89 x 145 * 41, 42 --- 42 64 ---
b) canister for goblets with lifter 800 mm high, max. 5 goblets Ø 70 x 800 78215719 43 100 --- --- ---
rack for SBS racks (30-40 mm high), 14 levels, with pivoting drawer bar 680 x 89 x 145 * 41, 42 --- 42 64 ---
c) canister for goblets with lifter 1100 mm high, max. 7 goblets Ø 70 x 1100 78215720 45 --- --- --- 212
rack for SBS racks (40-62 mm high), 9 levels, with pivoting drawer bar 680 x 89 x 145 * 41, 42 --- 42 64 ---
plus: goblets diameter 65 mm, 120 mm high Ø 65 x 120 78212792 500 480 848 1,484
rack for SBS racks (20-30 mm high), 21 levels, with pivoting drawer bar 800 x 89 x 145 * 40 28 --- --- ---
maximum storage capacity for straws 0.25 ml 280,000 268,800 474,880 831,040
rack for SBS racks (30-40 mm high), 17 levels, with pivoting drawer bar 800 x 89 x 145 * 40 28 --- --- ---
maximum storage capacity for straws 0.5 ml 105,000 100,800 178,080 311,640
rack for SBS racks (40-62 mm high), 11 levels, with pivoting drawer bar 800 x 89 x 145 * 40 28 --- --- ---
rack for SBS racks (20-30 mm high), 30 levels, with pivoting drawer bar 1100 x 89 x 145 * 42 --- --- --- 64 Explanatory note: 1 goblet (Ø 65 x 120 mm) contains max. 560 pcs 0.25 ml straws or max. 210 pcs 0.5 ml straws
rack for SBS racks (30-40 mm high), 23 levels, with pivoting drawer bar 1100 x 89 x 145 * 42 --- --- --- 64
rack for SBS racks (40-62 mm high), 16 levels, with pivoting drawer bar 1100 x 89 x 145 * 42 --- --- --- 64
* on request
BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400 BIOSAFE® 500 BIOSAFE® 600 BIOSAFE® 1000/1400
40 41 42 43 44 45
64 65
Rack-Number Sets Customisation
Racks for packages and boxes Rack with swing door Canister with lifter
(4 floors)
Further variations are possible. Please contact us to discuss your requirements.
66 67
Helium Vessels LHe
Liquid Helium
-269°C
4
HELIOS®
Vacuum Super-Insulated Storage Vessels for Stationary Use 70 - 71
(100 - 10,000 l)
STRATOS® SL-Serie
Vacuum Super-Insulated Transport Vessel for Stationary and 72 - 75
and Mobile Use (100 – 1,000 l)
STRATOS® 110
Vacuum Super-Insulated Transport Vessel for Stationary and 76 - 77
and Mobile Use
Helium-Siphon 78 - 83
For Easy Extraction of Liquid Helium
68 69
HELIOS®-Series
Convincing advantages:
Options: 4
• efficient helium-exhaust cooling system
• safety head HESA DN 32 with exhaust, pressure build-up and
• low evaporation rate (only 0.9%/day with
evacuation connection
HELIOS® 100 A) - exhaust ball valve
• compact dimensions - safety neck pipe
• robust construction made of highly - KF 32 centring and clamping ring
corrosion-resistant cryogenic stainless steel
- safety valve 1 bar, component tested to -269 °C
and high-strength aluminium
• optimised super-insulation by means • siphon connection Ø 9.6 / 10 / 12 / 12.7 / 16 mm
of multi-layered vacuum insulation and (only in connection with safety head
computer optimised thermodynamic
• clamping ring KF 25
construction with shields
• inner and outer vessels tested separately by • centring ring with O-ring (KF 25)
helium leak test • hose nozzle with KF 25 for pressure build-up
• by means of high-grade adsorption and
getter materials • PVC-hose for pressure build-up
• safety neck pipe • level sensor, rod form 12 mm
• integrated vacuum seal-off and safety • level sensor, KF 32 intermediate piece
device and integrated safety device on the
safety head • digital level indicator
• smooth-running, sturdy castors
• low maintenance r equirements
Technical Data
• wide range of accessories
Vessel Name HELIOS® 50A HELIOS® 100A HELIOS® 100
vessel material Aluminium Aluminium Aluminium
approval mark CE CE CE
geometrical capacity [l] 52 103 103
The vacuum super-insulation vessels of the HELIOS® -Series provide operating overpressure, max. [bar] 1.0 1.0 1.0
for the storage of cryogenic liquid helium. Due to a robust model, weight empty [kg] 46 74 125
best choice of materials and perfect manufacturing HELIOS® -vessels weight full [kg] 52 86 137
ensure the lowest possible loss due to evaporation available on the stat. evaporation rate [%/day] 1.3 0.9 0.9
market.
total height [mm] 1,150 1,210 1,325
total width [mm] 550 700 700
Standard Features: castor diameter [mm] 100 125 125
• 4 smooth-running castors, 2 with brakes neck pipe diameter [mm] 32 32 32
• hand ring connection KF 32 KF 32 KF 32
• power excess vole device 70 mbar, lockable We would be happy to to manufacture vessels up to a geometrical capacity of 10,000 litres also to your
• vacuum lock safety valve DN 40 specified d
imensions according to your specific requirements. Please contact us.
70 71
STRATOS® SL-Series (Super Light)
Convincing advantages: 4
• efficient helium-exhaust cooling system
• low evaporation rate (only 0.9%/day with
STRATOS® 100 SL)
• robust transport frame
• compact dimensions
• safety neck pipe
• integrated vacuum seal-off and safety device
and integrated safety device on the safety
head
• smooth-running, sturdy castors
• safety head with exhaust, pressure build-up
and evacuation connection
• lockable power excess voltage device (70
mbar)
• various extraction devices possible
• transfer-pressure 0-500 mbar
• optimised super insulation by means
of multi-layered vacuum insulation and STRATOS® 100 SL STRATOS® 250 SL STRATOS® 380 SL STRATOS® 1000 SL
computer optimised thermodynamic
construction with shields
• low maintenance requirements
Vacuum super-insulated transport and supply vessels for stationary
• wide range of accessories
and mobile use. Exploit the many advantages of the STRATOS®-Series
for your applications with cryogenic, liquid helium. Easy-to-handle
and high safety standards are the distinguishing features of this
lightweight. With lots of experience, technical know-how and highly
qualified manufacturing we can produce these high-tech v essels.
Of course, cryo-vessels have been approved according to the direc- Convincing Option:
tive on Transportable Pressure Equipment (TPED) and the European Highly Efficient, Electric Pressure Build-Up Control Device
Agreement concerning the International Carriage of Dangerous for STRATOS® 250SL, 380SL and 1000SL
Goods by Road and Rail (ADR/RID) with the π label.
An economical and also space saving solution of the integrated
The high level economical standard of the systems is augmented by heating system. It enables a controlled pressure build-up for easy
the highly efficient use of exhaust gas for cooling the neck pipe, the extraction of helium without external helium-pressure gas.
radiation shields and the insulation.
An optimised heating system evaporates liquid helium and overheats
the helium gas in order to achieve good pressure efficiency.
72 73
STRATOS® SL-Series (Super Light)
74 75
STRATOS® 110
LHe LNe Transport Vessel for Liquid Helium Robust, Economical and Practical
Convincing advantages:
Options: 4
• helium-exhaust cooling system
• vacuum insulated transfer siphons
• low evaporation rate (only 0.9%) • various siphon connections (Ø 9.6 / 10 / 12 / 12.7 / 16 mm)
• long-term vacuum protection by means of • level sensor
high-grade adsorption and getter materials
• level indicator
• optimised super-insulation by means of
multi-layered vacuum insulation and com- • anti-magnetic castors
puter optimised thermodynamic construc-
• cryo-protective features
tion use of shields
• inner and outer vessels tested separately by • IATA features
helium leak test
• integrated vacuum seal-off and safety device
Further special options on request
and integrated safety devices on the safety
head
• robust construction made of highly
corrosion-resistant cryogenic stainless steel
• low maintenance requirements
• wide range of accessories
Technical Data
Vessel Name STRATOS® 110
vessel material stainless steel
approval mark π
geometrical capacity [l] 111
Storage and transport vessel for cryogenic liquid helium with vacuum
operating overpressure, max. [bar] 1.5
super-insulation and long-term vacuum protection approved
weight empty [kg] 145
according to European Pressure Equipment Directive (TPED).
weight full [kg] 158
B
Contributing factors to the high level of economic efficiency of the
E stat. evaporation rate [%/day] 0.9
A
systems are the highly efficient usage of exhaust gases to cool the
total height A [mm] 1,520
neck pipe, the radiation shields and the insulation. D
diameter outer D [mm] 700
total width C [mm] 784
Standard Features: depth of immersion B [mm] 1,249
• safety neck pipe diameter castor F [mm] 160
• vacuum seal-off and safety device and integrated safety devices diameter neck E [mm] 32
F
on safety head siphon connection KF 25
C
• smooth-running, sturdy castors article-no. 78220309
• Safety head with exhaust, pressure build-up and evacuation
connection
• overflow device can be shut off (70 m bar)
76 77
Vacuum Insulated Transfer Siphon
Permanently Installed Siphon in STRATOS® Vessel
with Patented Anti-Oscillation Device:
Super-Insulated • Low Evaporation Rate
LHe
and Highly Flexible • No Helium Loss During Siphon Installation
• Ideal for Room with Low Height
• Low Wear of Siphon due to Installation into the Vessel
He transfer line
Plug-in coupling with
integrated manual LHe filling control system LHe level sensor
shut-off valve HELIOS® SAFETY HEAD
temperature sensor Ø 150 mm with screw flange
- various models HESA 150 SF
- easy coupling LHe siphon
- easy opening Bend protection
and closing
- optional
- robustness and
longevity
2800
Outer jacket
to He
- various models recovery system
- from pressure- anti-
resistant and robust see p.7 oscillation Ø1500
to super-light and device HELIOS® 1000
highly flexible STRATOS®
He liquifier
100
78 79
Models
A6: 50 mm
B3 Länge
length B=1000-2500
B=1,000-2,500mm
mm -
(starr)
(rigid)
B: transfer line
flexible with braiding B4 Steckkupplung
plug-in coupling -
Variant B4
C6: 145 mm
LHe Plug-In
Coupling
D: shut-off valve 200 147
integrated into
the filling tube
ØA2:
12 mm C Füllrohr
Filling Tube Standard Variant C4 Variant C5 Variant C6
Variants C1, C2,
A1: 1,600 mm
Small Flange Straight Filling Extended Angle
C3: Uninsulated Extension
C1: 700 mm
ØC2: C1 Länge
length C1
C1 (mm)
(mm) 700 Connection Tube Section
12 mm
C2 Durchmesser
diameter C2 (mm)
C2 (mm) 12
A: extraction
C: filling tube C3 Verlängerung
extension C3 (mm)
C3 (mm) -
145
tube
C4 Kleinflanschanschluss
small flange connectionC4 DN -
20
C4 -
C6
C4 DN
M10x1 female C5 Ohne Winkel -
C5 straight filling tube - Ø C2 C4
C1
C6 Schenkel Länge C6 (mm) 145
C6 angle section length C6 (mm) 145
C7 Ohne Füllrohr (mit Varia. B4) -
R1/8“ male
without filling tube
C7 -
Variants on Standard (with variant B4)
C3
A Entnahmerohr
Extraction Tube Standard Variant A4 Variant A5 Variant A6
Variant A3 Small Flange Straight Extended
A1 Länge A1
length A1 (mm)
(mm) 1,600
1600 Uninsulated extension Connetion Extraction Tube Angle
A2 Durchmesser
diameter A2 (mm)
A2 (mm) 12 Variant D4
Integrated Valve Variant D1 Variant D2
D Standard Angle Shaped Solenoid
50
50
A3 Verlängerung
extension A3 (mm)
A3 (mm) - in Filling Tube Without Valve in Filling Tube Shut-Off Valve in Male Part Valve DN4
A4 small flange connectionA4 DN
Kleinflanschanschluss - A4 D1 without valve in filling tube -
A4 -
A6
A4 DN
A5 Ohne Winkel -
A1
50
Ø A2 D2 valve in male plug-in coupling - 147
A5 straight extraction tube -
A6 Schenkel Länge A6 (mm) -
D3 valve in female plug-in coupling -
245
A6 angle section length (mm) -
Ohne Entnahmerohr Variant D3
A7 -
(mit Variante
without extraction
B4) tube (with D4 angle shaped solenoid valve - Shut-Off Valve in Female Part
A7 -
variant B4)
A1
A3
50
Caution: valve combination can produce shut-off
125
areas, which must be secured with a safety valve.
Combination of variants D3 and D4 without a 275
safety valve is possible.
80 81
Various Applications
LHe Extraction System from a 40’ LHe Vessel to LHe Transport Vessel LHe Transfer System from Transport Vessels (STRATOS®) 4
to MR Tomographs or Cryostats
3 m Hose Filling Angle with Integrated LHe Shut-Off O-Ring Fitting LHe Angle Adapter PHILIPS LLHe Angle Adapter ELSCINT Helium Siphon for STRATOS® 250 SL or other LHe
with Plug-In Coupling Suitable for 1½ UNF Vessel Valve and Small Flange Connection D16 to KF25 Article-No. 79422293 Article-No. 79422488 Vessels Article-No. 78200926
Article-No. 79420581 Article-No. 79404403 Article-No. 79402556
275
243.5 275 A
M40x2
M40x2
flexible with braiding
view A
1 1/2 UNF-12
Coupling nut
30
seal-off and °
1 00
30
and safety device 0°
10
DN 16
UNF 1 1/2"-12
KF25
16
100 Ø12
LHe stop valve
430
608
141 ca. 2,500 141 Centering Ring and O-ring KF25 Ø12
400
578
Article-No. 0647981
1360
Ø16
M40x2
Optional:
Adapter for 40’ LHe Vessel
200
Large Coupling to Small Coupling Ø16 Ø16
M10x1
Article-No. 78200346
12
Ø5 (4x)
M10x1
952
12
M10x1
800
Ø5 (4x) M12x1
2–1/4“ Heber-Verlängerung
Siphon Extension Siphon Extension SHIMADZU
Heber-Verlängerung
LHe Transfer
14–15/16“
62
P/T Measuring Unit for Automatic Filling
34
Deactivation for Installation into He Exhaust Line
Heber-Verlängerung
Siphon Extension TOSHIBA LHe Winkel-Adapter
LHe- Angle Adapter PT100 Sensor
TOSHIBA Art.-Nr.
Article-No. 79422810
79422810 PHILIPSF2000 Article-No.
PHILIPS F 2000 79423724
Art.-Nr. 79423724
M10x1
M12x1
Ø16 275
120
Weitere
Otherverfügbare
Available Diameters
Durchmesser pressure transmitter
M40x2
401
Ventil
valve DN4
DN4 Ventil
valve DN5
DN5 Ventil
valve DN7
DN7
Heber-Verlängerung
30
Helium Adapter Set 10
0°
9,6
9.6 10 12 12,7
12.7 16 TOSHIBA Art.-Nr.
Article-No. 79422810
78200152
220
156
Ø16
126
M12x1
UNF 1 1/2“–12
KF25
100
82 83
LH2 Liquid Hydrogen
-253 °C LOX Liquid Oxygen
-183 °C LNG Liquid Natural Gas
-162 °C
HYDROS®
Super-Insulated Vessels for Storage and for the Transport 86 - 87
of Liquid Hydrogen in Research and Industry (120 – 10,000 l)
STRATOS® SL-Series
Vacuum Super-Insulated Transport Vessel for Stationary 88 - 91
and Mobile Use (100 – 1,000 l)
STRATOS® 110
Vacuum Super-Insulated Transport Vessel for Stationary and 92 - 93
and Mobile Use
APOLLO®
Vacuum Super-Insulated Storage and Transport Vessel 94 - 95
(50 - 350 l)
MERKUR®
Tank for Truck Transport of Cryogenic Liquid Gases 96 - 97
on Public Roads (500 - 3,000 l)
84 85
HYDROS®-Series
Options:
Convincing advantages:
• efficient hydrogen exhaust cooling system
• forklift pockets
• low evaporation rate (only 0.9% with • handles on the side
HYDROS® 250) • skirt support
• compact dimensions
• robust construction made of highly
• siphon connection:
5
corrosion-resistant cryogenic stainless steel Ø 9.6 / 10 / 12 / 12.7 / 16 mm
• optimised super-insulation by means
of multi-layered vacuum insulation and
computer optimised thermodynamic
construction
• inner and outer vessels tested separately by
helium leak test
• long-term vacuum protection by means of
high-grade adsorption and getter materials
• safety neck pipe
• integrated vacuum seal-off and integrated
safety devices on safety head
• smooth-running, sturdy castors or skirt
support
• low maintenance Transport Vessel HYDROS®
• wide range of accessories Technical Data
vessel material stainless steel
approval mark CE
geometrical capacity, max. [l] 266
The vacuum super-insulated vessels of the HYDROS® series have
operating overpressure, max. [bar] 6.0
been designed for the storage and transport of cryogenic liquid
hydrogen for research and industry. weight empty [kg] 240
weight full [kg] 254.4
Standard Features: max. fill quantity [l] 202
86 87
STRATOS® SL-Series (Super Light)
Convincing advantages:
• efficient helium-exhaust cooling system
• low evaporation rate (only 0.9%/day with
STRATOS® 100 SL)
• robust transport frame
• compact dimensions 5
• safety neck pipe
• integrated vacuum seal-off and safety device
and integrated safety device on the safety
head
• smooth-running, sturdy castors
• safety head with exhaust, pressure build-up
and evacuation connection
• lockable power excess voltage device (70
mbar)
• various extraction devices possible
• transfer-pressure 0-500 mbar
• optimised super insulation by means
of multi-layered vacuum insulation and STRATOS® 100 SL STRATOS® 250 SL STRATOS® 380 SL STRATOS® 1000 SL
computer optimised thermodynamic
construction with shields
• low maintenance requirements
Vacuum super-insulated transport and supply vessels for stationary
• wide range of accessories
and mobile use. Exploit the many advantages of the STRATOS®-Series
for your applications with cryogenic, liquid helium. Easy-to-handle
and high safety standards are the distinguishing features of this
lightweight. With lots of experience, technical know-how and highly
qualified manufacturing we can produce these high-tech v essels.
Of course, cryo-vessels have been approved according to the direc- Convincing Option:
tive on Transportable Pressure Equipment (TPED) and the European Highly Efficient, Electric Pressure Build-Up Control Device
Agreement concerning the International Carriage of Dangerous for STRATOS® 250SL, 380SL and 1000SL
Goods by Road and Rail (ADR/RID) with the π label.
An economical and also space saving solution of the integrated
The high level economical standard of the systems is augmented by heating system. It enables a controlled pressure build-up for easy
the highly efficient use of exhaust gas for cooling the neck pipe, the extraction of helium without external helium-pressure gas.
radiation shields and the insulation.
An optimised heating system evaporates liquid helium and overheats
the helium gas in order to achieve good pressure efficiency.
88 89
STRATOS® SL-Series (Super Light)
90 91
STRATOS® 110
LHe LNe Transport Vessel for Liquid Helium Robust, Economical and Practical
Options:
Convincing advantages:
• helium-exhaust cooling system
• vacuum insulated transfer siphons
• low evaporation rate (only 0.9%) • various siphon connections (Ø 9.6 / 10 / 12 / 12.7 / 16 mm)
• long-term vacuum protection by means of • level sensor
high-grade adsorption and getter materials
• optimised super-insulation by means of
• level indicator
5
multi-layered vacuum insulation and com- • anti-magnetic castors
puter optimised thermodynamic construc-
• cryo-protective features
tion use of shields
• inner and outer vessels tested separately by • IATA features
helium leak test
• integrated vacuum seal-off and safety device
Further special options on request
and integrated safety devices on the safety
head
• robust construction made of highly
corrosion-resistant cryogenic stainless steel
• low maintenance requirements
• wide range of accessories
Technical Data
Vessel Name STRATOS® 110
vessel material stainless steel
approval mark π
geometrical capacity [l] 111
Storage and transport vessel for cryogenic liquid helium with vacuum
operating overpressure, max. [bar] 1.5
super-insulation and long-term vacuum protection approved
weight empty [kg] 145
according to European Pressure Equipment Directive (TPED).
weight full [kg] 158
B
Contributing factors to the high level of economic efficiency of the
E stat. evaporation rate [%/day] 0.9
A
systems are the highly efficient usage of exhaust gases to cool the
total height A [mm] 1,520
neck pipe, the radiation shields and the insulation. D
diameter outer D [mm] 700
total width C [mm] 784
Standard Features: depth of immersion B [mm] 1,249
• safety neck pipe diameter castor F [mm] 160
• vacuum seal-off and safety device and integrated safety devices diameter neck E [mm] 32
F
on safety head siphon connection KF 25
C
• smooth-running, sturdy castors article-no. 78220309
• Safety head with exhaust, pressure build-up and evacuation
connection
• overflow device can be shut off (70 m bar)
92 93
APOLLO®-Series
LIN LAR LOX Reliable, Safe and Durable Rapid Cold at the Point of Use
Options:
Convincing advantages:
• efficient exhaust cooling system
• pressure build-up regulator
• low evaporation rate (only 0.6%/day with • pressure reduction regulator
APOLLO® 200) • double extraction liquid side
• robust transport frame
• compact dimensions
• double extraction gas side
5
• integrated vacuum seal-off and safety • triple extraction liquid side
device • triple extraction gas side
• long-term vacuum protection by means of
• level indicator, capacitive, battery
high-grade adsorption and getter materials
• optimised super-insulation by means • level indicator, capacitive, 4-20 mA
of multi-layered vacuum insulation and • forklift pockets
computer optimised thermodynamic
construction • set of castors anti-magnetic
• inner and outer vessels tested separately by • cryo-protective equipment, full set
helium leak test
• robust construction made of highly Further special options on request
corrosion-resistant cryogenic stainless steel
• smooth-running, sturdy castors Technical Data
• low maintenance requirements APOLLO® 50 APOLLO® 100 APOLLO® 150 APOLLO® 200 APOLLO® 350
Vessel Name
1.3 bar 1.3 bar 1.3 bar 2.0 bar 2.0 bar
• wide range of accessories
vessel material stainless steel stainless steel stainless steel stainless steel stainless steel
approval mark CE CE CE CE0035 CE0035
Standard Features: Storage and transport vessel for
geometrical capacity [l] 49.5 99.2 149.5 198.5 348
• integrated safety device at the vessel neck cryogenic liquid nitrogen. With operating overpressure,
vacuum super-insulation and [bar] 1.3 1.3 1.3 2.0 2.0
max.
• vacuum seal-off and safety device
long-term vacuum protection. weight empty [kg] 44 62 79 100 160
• smooth-running, sturdy castors and transport frame Approved according to weight full LIN [kg] 85 145 204 266 450
• pressure indicator European Pressure Equipment stat. evaporation rate LIN [%/day] 2 1.2 1 0.6 0.5
• level indicator Directive PED. Transport in total height A [cm] 80 114 146 117 165
• EK-siphon with exhaust and overflow valve unpressurised condition with
diameter outer D [cm] 50 50 50 70 70
inserted transport plug.
• integrated pressure build-up total width C [cm] 65 65 65 80 80
• decanting hose (1.5 m) with phase separator depth of immersion B [mm] 58.5 92 122 91 135
• transport plug castor diameter F [mm] 125 125 125 160 160
• cold-protection gloves and safety glasses with side protection neck diameter E [mm] 50 50 50 50 50
siphon connection KF 50 KF 50 KF 50 KF 50 KF 50
article-no. LIN 78202700 78202701 78202702 78202748 78202749
article-no. LAR 78202700/AR 78202701/AR - - -
article-no. LOX 78200520 78202701/O2 78202702/O2 - -
94 95
MERKUR®-Series
Ideal for Transporting Cryogenic Gases
Truck Transport
LIN LOX LAR for the Most Varied Applications in Research, Medicine
of Cryogenic Liquid Gases
and Industry
Rail (ADR/RID) with test certifi- regulator (1-6 bar) 3 level indicator
Standard Features: 6 6 6
4 pressure indicator
cate of the German Inspection • maximum pressure 7 4
• integrated level and pressure indicator 5 analysis valve
(TÜV). regulator (1-4 bar) 3
6 safety valve
• pressure build-up 8 2
• mounting kit for service 7 trycock
• filling, liquid extraction valve vehicle 8 purge valve
1
9 pressure build-up system
• analysis valve • condensate drip tray filling 10 vacuum seal-off and
port pressure build-up safety device
• purge valve 9
evaporator
96 97
LIN Liquid Nitrogen
-196 °C LNe Liquid Neon
-246 °C LNG Liquid Natural Gas
-162 °C
98 99
Cryo Line Systems
LIN LHe LH2 LNe Cold Stays Cold – Cryogenic Liquid Gases such as Nitrogen, Oxygen and
Wherever You want it! Argon Flow Through Special Cryo Line Systems
LOX LAR LNG LKr LXe
Convincing advantages:
• welded construction of anti-magnetic
highly corrosion-resistant stainless steel
• in rigid or flexible model
• super-insulated connections for flexible
extension and combination options
• fast detachable plug-in coupling and per-
manently installed welded connections
• immense durability of the insulation
vacuum due to use of adsorption
materials and special getter 6
• quality assurance at every stage
of the manufacturing process
• leak test of the inner and outer line
So that the gases get from the vessels to their “Point-of-use” with low Significant Construction Features
evaporation loss Cryotherm offers vacuum super-insulated transfer
line systems as well as the associated features. 1 inner pipe made of high corrosion-resistant 6 Expansion compensator for the compensation
So that your project can be realised is an extremely short time and cryogenic stainless steel (1.4301), completely of the linear expansion due to heat
you can utilise the economic advantages immediately we will be at welded
7 spacers between inner and outer line
your side from the beginning. Together with you we carry out the
planning, design and assembly stages of the cryo-line system tailored 2 flange connection of clamping ring and
8 adsorption material
to your requirements. fastening screws
A building brick system specially developed for the values 3 O-Ring-seal 9 multi-layers of vacuum insulation due to com-
DN 14 and DN 25 is suitable for the most varied assign- puter optimised thermodynamic construction
ments and can be delivered directly ex stock in the 4 cryogenic seal
}
10 line sections 1 and 2, super-insulated,
standard lengths of 3, 6 and 12 m.
5 combined vacuum seal-off and and safety 11 self-contained vacuum system
device ensures the vacuum area against
inadmissible pressure
100 101
Flexible and Rigid Line Systems
Flexible Line Systems Rigid Line Systems Gas Separator Phase Separator Stations with Pressure-Maintaing System
Convincing advantages: Model GPA 1-1 Vertical Horizontal
Vacuum super-insulated f lexible Vacuum super-insulated
• optically appealing geometrical capacity [l] 5 50 100 50 100 200 200
line section 3 m long, DN 20 solenoid valve with plug-in operating overpressure, max. [bar] 18 1.5/3 1.5/3 1.5/3 1.5/3 1.5 3
with plug-in coupling DN 14 coupling DN 14 • made of anti-magnetic highly weight empty/full [kg] 17/21 50/95 68/158 50/95 68/158 90/270 90/270
corrosion-resistant durable stainless diameter outer A [mm] 219 340 450 450 550 650 650
steel, consequently can be used in B [mm] 480 - - 740 940 1,100 1,100
clean rooms and in the food industry C [mm] 430 772 837 90 90 90 90
D [mm] 50 1,192 1,312 650 750 772 772
• can be extended without any trouble and E [mm] - 1,360 1,480 830 930 1,280 1,280
can be combined using plug-in coupling F [mm] - 270 270 350 350 270 270
• immense durability of the vacuum H [mm] - 350 350 350 350 450 450
filling port DN 14 M DN 14 F DN 14 F DN 14 F DN 14 F DN 14 F DN 14 F
due to use of adsorption material
6
extraction connection DN 14 M DN 14 M DN 14 M DN 14 M DN 14 M DN 14 M DN 14 M
and special getters. Thus, you reduce exhaust connection 1/4" NPT DN 25 DN 25 DN 25 DN 25 DN 25 DN 25
your gas consumption and extend pressure control mechanical electric electric electric electric electric electric
your maintenance intervals. article-no. 78203542 78206619 78206617 78200335 78200285 78208010 78203475
102 103
Gas Separators Phase Separators
• economical at constant extraction • ideal for small consumers and/or numerous points of extraction
• continuously maintained cold of the complete line between point • emergency supply function
of input (eg. liquide storage tank) and point of extraction • most popular separator system 6
• input (eg. liquide storage tank) pressure is constant up to point of • control electrical
extraction
• arranged at the highest point of the line system
• ideal for mass-consumers
• control mechanical
Technical Data
Technical Data
Model Vertical Horizontal
Model 10 V GPA 2.2
geometrical capacity [l] 50 100 50 100 200
geometrical capacity [l] 10 operating overpressure,
operating overpressure, [bar] 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3 1.5 / 3
max.
[bar] 8
max. weight empty/full [kg] 50/95 68/158 50/95 68/158 90/270
weight empty/full [kg] 23/32
øA [mm] 340 450 450 550 650
øA [mm] 303
B [mm] - - 740 940 1,100
B [mm] 840
C [mm] 772 837 90 90 90
C [mm] 50
D [mm] 1,192 1,312 650 750 772
D [mm] 95 Ø
E [mm] 1,360 1,480 830 930 1380
filling port DN14 female
F [mm] 270 270 350 350 450
extraction connection DN14 male
H [mm] 350 350 350 350 450
exhaust connection DN14 female
filling port DN14 female DN14 female DN14 female DN14 female DN25 female
pressure control mechanical
extraction connection DN14 male DN14 male DN14 male DN14 male DN25 male
article-no. 79404837
exhaust connection DN25 / 1" DN25 / 1” DN25 / 1” DN25 / 1” DN25 / 1”
pressure control electrical electrical electrical electrical electrical
3 bar: 78203475
article-no. 78200316 78200284 78200335 78200285
1.5 bar: 78208010
104 105
Multiline
means of high-grade a dsorption • nitrogen return flow at 80K <80K nitrogen forward flow
vacuum casing 6
and getter materials
• integrated vacuum seal-off <4K helium forward flow
and safety device super-insulation
4K helium forward flow
• quality assurance in every phase thermic shield
of production, eg. using x-ray 80K nitrogen return flow – shield cooling
and helium leak tests
• effective protection against warmth The multiline described here Experienced Cryotherm engi- According to the customer
influx by means of integrated
with four inner lines running neers will design the insula- requirements further medium
thermically cooled shields
process gas is only one of the tion and size of the required lines can be integrated (for
The transfer of cryogenic The Cryotherm multi-transfer The vacuum protects against design concepts of Cryotherm process lines according to each example a 2K pumping line).
liquid helium demands high lines almost completely prevent heat influx by convection where multilines. customer application.
standards of insulation. radiation of heat due to their as the thermic shield, cooled
ingenious structure. actively with liquid nitrogen,
The medium lines, like helium efficiently prevent heat transfer
The low level of t emperature
forward flow, helium return by radiation from the outer pipe Insulation Quality
(-269 °C / 4 K) in c onnection with
flow and liquid nitrogen f orward to the helium lines inside.
the low evaporation e nthalpy of
liquid helium results in a high flow are first coated with a Also the fixing of the inner lines foam Insulation 1
level of requirements for the number of layers of highly requires high demands with
reflective foil (super-insulation). regard to flexibility and low heat
construction of transfer lines. A vacuum Insulation 3
heat input of only 0.7 W leads to The return flow of nitrogen is influx and the h ighest care has
connected to a surrounding to be taken during manufactur-
evaporation of one litre of liquid
thermic shield. The t hermic ing.
vacuum pulverisation 10
helium per hour.
shield is c overed by multilayer
super-insulation. Finally, this
vacuum super-insulation 100
For this reason it is necessary to ~ insulation
structure is surrounded by a
keep the radiation on the liquid
vaccum enclosure which will be
vacuum super-insulation M U L T I L I N E 3000 effectiveness
with cooled shields
helium lines as low as possible.
evacuated to high vacuum level.
1 10 100 1000 10000
106 107
CONTROL AND
MONITORING TECHNOLOGY
For Cryogenic Gases
BIOSAFE-CONTROL® ß 110
Level Control and Vessel Monitoring
7
CRYO LC® 112 - 113
Level Control Device
108 109
BIOSAFE-CONTROL®® ßß CRYO-MESSENGER®
Integrated Level Control and Vessel Monitoring Remote Monitoring via SMS, E-MAIL & Co.
for Safe Long-Term Storage
Storage. www.cryo-messenger.de
Technical Data
Convincing advantages: Convincing advantages:
• display of the vessel status BIOSAFE® with
• certified reliability with CRYO-MESSENGER® • redundant cryobank monitoring
• level control via height provenmeasuring principle
adjustable sensor with • easiest operation via
• clear presentation of vessel status
manipulation protection • liquid level adjustable from www.cryo-messenger.de
• temperature measurement 0 (gas phase) – 100% • transfer of alarm signals and logged
• easy operation at BIOSAFE- temperatures via e-mail, SMS or FAX
sensor, measurement range
CONTROL® ß and at PC • quick assembly
-200 +50 °C (accurate to • flexible evaluation of logged
Central Functions daily report to • can be extended due to modular design
+/- 2 °C) temperatures and alarms Global Data Center
• filling stop when lid open / (per network) • central functions for control of • analogue input sockets for
• I/O box (option) with relay main valve (I/O-box optional) logging of eg. temperatures
manual defogging possible
for main valve, device • central alarm administration • flexible current supply in wide
• alarm signal when: and transfer to PC (by e-mail, ranges (100-240 VAC)
error, collective alarm,over-
- nitrogen shortage and SMS or Fax as option)
level exceeding temperature and 2 extra
• including PC software for extensive doc-
freely-assignable relays umentation of the data of a cryobank
- exceeding of vessel tem-
perature • collection and buffering • modern matched design with the 7
of all cryobank data for new BIOSAFE® generation
- exceeding of maximum
time for lid open transfer to a PC • parameter: response delay magnetic
valve, reverse cooling function, alarm is forwarded via
- exceeding of maximum • connection of up to 32 alarm on/off switching adjustable SMS, E-Mail or FAX
filling time sensor break- systems to one network
age or sensor short circuit • collective filling
- and lots more BIOSAFE-CONTROL® ß A Bit More security! The Individual Components
• free selection of database,
• display of alarm signal in thus fully network capable
Software The remote superordinate con- • CRYO-MESSENGER® (Article no. 78207280)
• in the German, English, trol system CRYO-MESSENGER® For remote monitoring of cryo-vessels and transfer of alarm signals
plain text • interface RS 232 to PC
French, Spanish and Italian has its cryo-vessels and cryo by SMS, E-Mail or FAX. Data transfer via GSM-Dualband-Modem.
• software and processor • parameter can be set on languages banks on site under permanent Daily routine call to the Global Data Center
independent redundant BIOSAFE® and PC Technical Data:
• setting of all vessel param- control: around the clock, 365
monitoring of minimum • MODBUS software as inter- eters in clear and password Dimensions: 400 x 300 x 200 mm
days a year.
and maximum alarm with face (RS485) to a superordi- protected pop-up windows Power supply: 100-240 VAC/47-63 Hz/8 VA
CRYO-MESSENGER® transfers all
separate software alarm nate control system • logging and evaluation of 2 analogue inputs: 0-10 VDC
logged data to the Global Data
• potential-free alarm outputs temperature curves of indi- 2 signal inputs: for potential-free contacts
vidual and all vessels Center (www.cryo-messenger.
for your building technology • CRYO-MESSENGER® with rechargeable battery (Article no. 78207281)
de) which in turn transfers
(I/O box optional) • logging and evaluation of
any reports to you, irrespec- CRYO-MESSENGER® with an added lead-gel rechargeable battery (12
alarm signals and events in
• analogue output of temper- tive whether by SMS, E-Mail V/7.2 Ah), so that even in case of a power failure an alarm signal can
individual and all vessels
ature measurement for your or FAX. Of course, you can call still be raised.
• visualisation of vessel status
building technology up data on your vessels at any • Extension module E-M8 (Article no 78207284)
on PC
• connection via Ethernet • evaluation, lists and time. It‘s your choice! Further for extension to 8 signal inputs for potential-free contacts
(optional) diagrams as protected PDF- information can be found un- • Extension module E-A4/1 (Article no. 78207285)
files, CSV-files (EXCEL) der: www.cryo-messenger.de for extension of 4 extra analogue inputs (0-10 VDC).
110 111
CRYO LC® (Level Control)
Application
Convincing advantages:
• modular design
CRYO LC® can be used in vessels and systems of all sizes in which the
• quick assembly
level sensor can be equipped.
• easy operation The device can be installed in various ways:
• individually customised level control and • compact devices, ready for operation, in cabinet with display and
level sensor, dependent on application and operation unit
customer requirements
• for installation in control cabinet or as a • installation in cabinets, modular, CRYO LC® basic module for
separate, independent device assembly on C-tracks, display and operation unit with flat ribbon
• measurement and control are cable ready for installation in the switch cabinet door
independent of pressure as
• installation in cabinets, modular, CRYO LC® basic module for
measurements are taken against a
reference sensor assembly on C-tracks, without display and operation unit, control
• basic module can be operated at the same and signal retrieval can be carried out directly by means of SPS
time with at least two display and operation • two display and operation units attached to one CRYO LC® basic
units (local and remote control)
module (local and remote control)
• trigger guard against manipulation and
operator error / device only runs in auto-
matic mode if the reference sensor is colder
than approximately -100 °C Level Detection: Level Control: Further Functions:
• level monitors itself as the sensors are Level detection is effected by The level is automatically con- • collective filling
monitored for wire breakage and short four sensors. trolled between LEVEL 2 and
circuit • “MANUAL FILL“
At the lowest point of the level LEVEL 3. Fall below of LEVEL 2
CRYO LC® • each signal (LEVEL 1-4, filling, alarm) is du- • “START AUTOFILL“
plicated by means of a change-over contact sensor there is a fifth PT sen- a potential free change-over
Device for level detection and level control in vessels and systems. • “AUTO FILL ON/OFF“
• potential-free change-over contact: high sor as a reference sensor. Only contact will trigger on the basic
CRYO LC® operates independent of pressure. performance switch (230/VAC/3A), thus module and solenoid valve will • monitoring of the sensors
when this sensor registers a
external devices can be directly controlled be opened. If the level reaches for wire breakage and short
System via this feature
temperature of under approx.
LEVEL 3 the change-over con- circuiting
CRYO LC® consists of the basic module as a built-in device for -100 °C will the level detection
• SPS-compatible interface
be activated. tact will be triggered again
C-tracks with a level sensor manufactured to customer requirements, • flexible current supply in wide ranges
and the solenoid valve will
the display and operation unit (optional components) as well as the (85-264 VAC and 24V DC) The conditions LEVEL 1 to
be closed. The filling process
cabinet. LEVEL 4 are displayed on the
shown on the display and oper-
panel and operation unit and
Functions are retrievable via the potential
ating unit as “FILL”. The function
Level detection: detection of 4 levels (LEVEL 1 to LEVEL 4), can be switched on and off us-
free change-over contact. An
display and signal output (= potential free change-over contact) plus ing the buttons “AUTOFILL ON”
exceeding of LEVEL 4 or fall be-
and “AUTOFILL OFF”.
level control: automatic control of the level between LEVEL 2 and low LEVEL 1 result in an alarm
LEVEL 3.
Application Examples: (optically and acoustically at the
• phase separator display and operating unit or via
In both functions there is an alarm if LEVEL 1 is underrun. Also on Various sensors
exceeding of LEVEL 4 or sensor short circuit as well as sensor wire • dewars/cryostats the potential free change-over
breakage. • cooling baths contact at the basic module).
112 113
LHe Level Measurement Device
Technical Data
Complete Packages with Mount, Sensor, 7
Display
Display device Sensor Type Article-No.
rod sensor with connection Ø 12 mm for STRATOS 250SL
®
78200882
digital display
installation by means of pinch screwing
STRATOS 380SL
®
78200913
1 measurement area synchro- KF32 or KF50 intermediate section
nized with related sensor between vessel and safety head STRATOS® 1000SL 78200927
With this device liquid helium levels in cryo-vessels up to 1,370 mm
are displayed in linear form. Several sensors are available with vari- function Selection via 2 Keys (on, heat) sensor current 80 mA / 100 mA
Combination Options
ous measurement length. The measurement device is factory-syn-
chronised to the desired measurement range. function display for “sensor not locked“ and Type Article-No.
sensor length from 500 to 2,000 mm
“low battery” level measurement device with
Due to a built-in rechargeable battery the levels can be m
easured 78200194
connection sockets for power supply, sensor, plotter charger
at any time within remote applications. A charging device which can output voltage (0-1 V), plotter output current active measuring length 450 to 1,370 mm rod sensors 12 mm for:
also be used as a power supply unit is part of the package. (0-10 mA)
HELIOS® 100A 79243593
Connection opportunities for remote display and a plotter round off power supply via built-in rechargable battery 12 V
STRATOS® 100SL 79243593
/ 1.1 Ah or external power supply 12 V / 400 mA
the package. STRATOS® 50 79243584
The device switches itself off automatically after maximum 60 power input approx. 4 W
alternative to STRATOS® 50:
seconds. KF32- intermediate section with 79248661
plastic cabinet (H x W x D) 67 x 148 x 190 mm sensor
alternative to STRATOS® 100 SL:
For stationary vessels a 19” version is also available KF50-intermediate section with 79248662
sensor
Custom-made models on
request
114 115
TRANSPORT COOLING LIN Liquid Nitrogen
-196 °C
For Vehicles
116 117
CRYOGEN® Trans-Series
Accessories:
Convincing advantages:
• installation material for one compartment or multi-compartment
• extremely low operating mate-
vehicles whether trailers, semi-trailers, swap bodies or vessels.
rial costs on long distances
• investment comparable with con- • weather protection hood
ventional system performance • temperature control. In the case of mutli-compartment vehicles
• high cooling power in distribution traffic the number of control units and temperature sensors is depend-
• optimal distribution of cold ent on the number of compartments
• redundant cooling • junction box
• noiseless • door switch or door switch combined with tail-lift control
• life expectancy 30 years • safety switch
• robust construction made of highly
corrosion-resistant cryogenic stainless
steel or high-strength aluminium
• multi-layered vacuum insula-
tion and computer optimised
thermodynamic construction
• inner and outer vessels tested
separately by helium leak test
• long-term vacuum protection due to high- Technical Data
Are you looking for suitable transport cold to safeguard your chain grade adsorption and getter materials
Vessel Name CT 200 CT 300 CT 430 CT 550
of cold? Even in extreme summer heat the temperatures have to be
geometrical capacity, max. [l] 200 300 409 523
8
maintained? When you unload parts of your cargo the recooling of
your truck loading area needs to be quicker? Are you looking for a operating overpressure, max. [bar] 5 5 5 5
robust and low maintenance solution for cooling your trucks? weight empty [kg] 140 186 300 380
In distribution transport the cooling system needs to recreate the weight full [kg] 300 427 630 800
required temperatures immediately after the door is opened each
total length H [mm] 1,580 2,040 2,290 2,720
time. Our system “CRYOGEN® Trans” ensures quick cold and cools
your truck with cryogenic liquid nitrogen. In this fashion after the diameter E [mm] 600 600 650 650
door has been opened the cargo area is brought rapidly back to the distance mount (± 100 mm) B [mm] 800 1,000 1,200 1,400
required temperature.
distance mount A [mm] 525 625 700 800
• vacuum super-insulated CT-vessel with instruments and instru- width mount C [mm] 80 80 100 100
ment protection case height mount G [mm] 624 624 700 700
118 119
Customising / Turnkey Solutions
Cryo-Cooler / Cooling Baths
120 121
Cooling Baths
Shrinking with Cryo-Cold
LIN A Perfect Fit in Metal Processing For the Highest Quality
with Liquid Nitrogen
122 123
Reference Cryobanks Reference BIOSAFE® XXL
Cryopreservation is currently the only way to store viably animal, Areas of Use:
botanical and above all human samples and cell bonds over almost • worldwide largest Cryo-Biovessel, 8,800 l content per vessel
any lengths of time and to reanimate them at a certain time.
• number of samples: 20,000,000
The structure of a complete cryobank is possible with a BIOSAFE®
• storage time; at least 30 years
system without any problems. Cryotherm realised a Bio-Cryo-Bank
with ~100 Cryotherm vessels operated with liquid nitrogen. • gas phase storage at -180 °C
• maximum operating safety
• economically, ecologically and technically optimised
• space saving
• 30% saving in storage costs per sample as against traditional ves-
sels
• better cooling quality (consistency)
• defined interfaces for the automation of inflow and output systems
• high demands on manufacturing tolerance
• pressure lifting bag instead of rollers for easier handling
9
© Copyright: Fraunhofer IBMT, Aufnahmen: Dr. Frank Obergrießer, 2012
© Copyright: Fraunhofer IBMT, Aufnahmen: Dr. Frank Obergrießer, 2012 © Copyright: Fraunhofer IBMT, Aufnahmen: Dr. Frank Obergrießer, 2012
124 125
Reference of Complex Transfer
Reference Cryotherm® Cryo-Cooler Lines and Phase Separators
Highest Performance Vacuum super-insulated supply line from a 50,000 l tank to a total of
also under the Toughest 25 experimental chambers
Operating Conditions • total length 300 m of vacuum super-insulated transfer lines
Round the Clock • ten vacuum super-insulated phase separator stations integrated
Extremely Low Vibration into the transfer line system; the models used 100 l, 200 l and
• closed loop system with 2,500 l model
up to 10 bar pressure to • vacuum super-insulated buffer vessel 2,000 l
increase the boiling point • system designed for 2,000 l/h maximum through-put
of the liquid nitrogen and
• emergency deactivation function by means of an oxygen
reduce vibration of the
deficiency warning system and vacuum super-insulation shut-off
components to be cooled
valve
• variable frequency
• safe, reliable and application-oriented!
minimises resonance on the
mechanical system to be
cooled
Ease of Use
• continuous operation
• fully automatic operation
and re-fill routines
• optional remote control
• smooth running, sturdy
castors with locking function
9
Low Maintenance and Cost-Effective Operation
• extremely reliable industrial components
• low consumption of liquid nitrogen
• short reaction times in case of service needs with a secured
supply of spare parts
• vacuum super-insulated transfer lines
• phase separator
• customer-specific types of operation
• integrated interruption-free power supply
126 127
Reference Multiline
Project: Cryogenic Distribution System
Project: XFEL Cryomodule Test Facility
LHe 2K Valve Box and Multichannel LHe
with 2K Valve Box (Germany)
Transferline (USA)
Multi-Transferline
• various cryogenic media
(LHe and LIN)
• several temperatures (2K,
5K, 40K and 80K)
• varying pressures and
conditions 9
• cooling and heating
independently of each other
with differing rates and
sequences
• minimised contact between
Multi-transferline
inflow and return flow lines
• extremely low heat inflow
rate
2K valve box
128 129
Cryo
ACCESSORIES
Gloves 132
Aprons 132
Online-Shop 133
10
130 131
Cryo-Safety Accessories
length: approx. 400 mm, 5 fingers for temperature range to -160 °C forearm L 78400887 includes cryo-gloves, cryo-apron, cryo-protective shield and 2 warning signs 78400851
length: approx. 400 mm, 5 fingers for temperature range to -160 °C forearm XL 78400856
length: approx. 500 mm, 5 fingers for temperature range to -160 °C elbow M 78400899
length: approx. 500 mm, 5 fingers for temperature range to -160 °C elbow L 77031451
length: approx. 500 mm, 5 fingers for temperature range to -160 °C elbow XL 78211327
Eye and Face Protection: Cryo-Protective Shield and Goggles Nitrogen Vessels •
Product Description Article-No.
cryo-protective shield and head protection shield of vulcanized fibre foam padded Helium Vessels •
77031519
inspection Glass dimensions: (WxH) 460 x 190 mm
protective goggles with side
protection
for protection against fumes and splashes 77031520 Rack Systems •
Spare Parts • 10
Offers •
132 133
SERVICE
11
134 135
After-Sales-Service for Cryo-Features
This all belongs to all-round The storage and supply and They are manufactured Service begins so to speak with The former has the advantage
care after sales: delivery storage vessels developed according to the regulations of the delivery: this is often carried that the instruction takes place
including commissioning by by Cryotherm, the phase the Pressure Equipment Direc- out with assembly, commission- on the actual features used
the service technicians and separators, the line systems tive (PED) and the transport ing and operational qualifica- under practical conditions.
instruction of the customer, an and freezing appliances are device guidelines and tested by tion by our Cryotherm-Service The latter is distinguished by
offer of regular m aintenance used in industry as well as in experts and approved. The rel- technicians and a comprehen- simulation of failures on
and courses of instruction research and medicine. evant certificates belong to the sive briefing of the users. Apart equivalent apparatus without
according to agreement as Therefore, the cryo-features scope of delivery in each case. from that intensive courses of the danger of any interruption
well as a service hotline for by Cryotherm has high-grade, For cryobiology the storage instruction are on offer that are of operations.
emergencies. specially developed vacuum systems on offer by C
ryotherm available at the customer‘s loca-
Cryogenic gases are effective super-insulation to keep heat have been classified and tion or in the Cryotherm factory.
sources of cold that are used losses at a minimum. The de- approved as medical products.
for numerous processes as well wars can be used in a stationary
as for safe (long-term) storage manner eg. in laboratories and 11
of materials that are often also in a mobile fashion eg. In
valuable. air and overseas transport.
136 137
After-Sales-Service for Cryo-Features
11
138 139
After-Sales-Service for Cryo-Features
140 141
After-Sales-Service for Cryo-Features
Execution of IQ and OQ The service hotline number can be found on every device delivered
(Installation qualification and operational qualification) by us. Callers are given advice on the telephone immediately through
which often many a problem can be cleared up. If that is not possible
Documentation results according to GMP (Good Manufacturing
an appointment is made for a service technician dependent on the
Practice) guidelines and protocols
urgency of the situation.
11
142 143
About Us
CRYO-SPECIALISTS
Turn-Key-Solutions 152
144 145 12
Origins and History
146 147 12
Locations
148 149 12
Production
150 151 12
Turn-Key-Solutions
Turn-Key-Solutions
Certificate
• planning
DIN EN ISO 13485
quality manual quality management s ystem quality management system
- conceptual design and overall planning
- planning of the pipe DIN EN ISO 9001 medical devices enclosed in
- spatial planning DIN EN ISO 9001
- electrics planning
- building technology
- MSR-planning
directive 2014/68/EU • documented directive 93/42
- safety planning
PED procedures EEC MDD
• manufacture / Documentation © Copyright: Fraunhofer IBMT, Aufnahmen: Dr. Frank Obergrießer, 2012
Certificate
Certificate
Production
Cryotherm Vessel Storage Systems
boiler and pressure
for the long-term storage of biological, medical
Vessel Code
and chemical material
152 153 12
Genealogie ©
BIOSAFE® BIOSAFE®-
Rack-Systems Rack-Systeme
BIOSAFE®
Rack-Systems
Further
Storage weitere
Vessels Lager-Behälter
HYDROS® APOLLO® APOLLO®
Further weitere
Transport Transport-
Vessels Behälter MERKUR® MERKUR®
HYDROS® STRATOS®
Transport Transport
Cooling for kühlung für
Vehicles Fahrzeuge CRYOGEN® Trans CRYOGEN® Trans CRYOGEN® Trans
Customising / Customizing /
Turnkey Turnkey
Solutions / Solutions /
Cryo-Cooler / Cryo-Cooler /
Cooling Baths Kühlbäder BIOSAFE® 8,800 Cooling Baths Cryo-Cooler
154 155
NITROGEN VESSELS
APOLLO® LIN Supply and Storage Vessel (50 - 350 l) · JUNO® LIN Supply and Storage Vessel (30 l)
SIRIUS® LIN Supply and Storage Vessel (1,000 - 2,000 l) · SATURN® LIN Transport Vessel (50 - 300 l)
MERKUR® LIN Transport Tank (500 - 3,000 l) · STELLA® Working Dewar (0.5 - 10,000 l) · LAB® Dewar Series (4 - 50 l)
BIOSAFE® RACK-SYSTEMS
Racks · Drawers and Cryoboxes for Vials · Canisters for Straws in Goblets · SBS Boxes (Microtiter)
Cassettes for Freezing Bags
HELIUM VESSELS
HELIOS® LHe Storage Vessel (100 - 15,000 l)
STRATOS® LHe Transport Vessel (100 - 1,000 l) · LHe Siphon
Reprinting, reproduction and copying of all drawings, pictures, photographs, graphics and texts of brochures only after written approval by Cryotherm GmbH & Co. KG.
OTHER VESSELS
HYDROS® LH2 Transport Vessel (1,000 - 15,000 l) · STRATOS® Transport Vessel (100-1,000 l)
APOLLO® Supply and Storage Vessel (50 - 350 l) · MERKUR® Transport Tank (500-3,000 l)
Spare Parts Service · Vessel Hire · Instruction/Training · Operating Manual · Service Hotline
Contact
Cryotherm GmbH & Co. KG Cryotherm Inc.
Euteneuen 4 5126 South Royal Atlanta Drive
57548 Kirchen/Sieg Tucker, GA 30084
Germany USA
-: +49 27 41 95 85-0 -: +1 770-274-2410
d: +49 27 41 69 00 d: +1 770-934-3384
m: info@cryotherm.de m: info@cryotherminc.com
w: www.cryotherm.de w: www.cryotherminc.com