You are on page 1of 63
EXPLANATORY NOTES SECTION ~1- GENERAL 1.1 Explanatory notes for various items of work in price schedule are given in section-2. 1.2 The basic quantities of components and materials required to make up a unit of work, are indicated for guidance only. There may be minor variations to suit erection but no adjustment i prices of price schedule shall be made on that account. In estimating the prices for various items of work, provision for loss and wastage in transit and erection should be provided for, over and above the basic quantities of components and materials required to make up a unit of work, indicated herein, except where otherwise specified for materials supplied by the Purchaser. 3 Inthe explanatory notes given in Section-2 of this Chapter, the term 'Small parts steel work' is meant to cover fabricated steel work made from rolled steel sections, complete with bolts and nuts and washers where required for fastening the small parts steel work to any structural member. The term “attachment” wherever used is intended to cover castings, forgings, machined or ‘welded components or fittings, which are attached directly to a structural member, or mounted on small parts steel work and shall include bolts and nuts for fastening the attachment to the structural member or small parts steel work. 1.4 In the explanatory notes given in Section 2 of this chapter, the term "bimetallic connection" is meant to cover any connection between a copper conductor and an aluminium conduetor. The clamps used for such connections shall be made of a suitable aluminium alloy or copper alloy and the copper/aluminium conductor shall be wrapped with a bimetallic (aluminium copper) strip to prevent direct contact between aluminium and copper. 1.5 Special notes for measurements are included in section 2 of this chapter under various items, where necessary 1.6 Reconciliation of materials supplied by the Purchaser. (a) The following procedure shall be adopted for the final reconciliation of the various equipments, materials, fittings and conductors supplied by the purchaser. ‘All the materials supplied by the purchaser shall be correctly accounted for and quantities reconciled on completion of the work by the contractor. On completion of work, all surplus materials supplied by the purchaser together with the ones found defective or that have become defective of broken on account of defective materials and/or workmanship shall be returned to him by the contractor. (b) STEEL: Cost of rolled steel masts, gantry masts, fabricated steel work damaged or not accounted for will be recovered at rates specified in note at the end of para 1.6(e) (c) WIRES AND CONDUCTORS: The purchaser will supply to the contractor all wires and conductors if required for the work based on unit quantities, inclusive of erection allowances i.e., 0.5%. (zero point five percent). It is general condition that the contractor shall return to the purchaser all wires and conductors which have been supplied to him but not utilised on works. Should the contractor be unable to do so, the purchaser shall be entitled to recover the cost of such wires and conductors as specified in note at the end of para 1.6(e). For the purpose of reconciliation the length of wire or conductor deemed to have been supplied by the purchaser to contractor will be the length stencilled on the drum and the length deemed to have been returned by the contractor will be the actual length of cut-pieces and/or the length calculated on the basis of the actual weight of cut pieces serap and linear densit d) SOLID CORE INSULATORS: The total requirement of solid core insulators for the work will be computed on the basis of the final quantities of schedule of prices. Prescribed proof loading tests and mechanical tests are to be carried out as per RDSO's specification satisfactorily, prior to erection. This test shall be carried out by the contractor at his ‘own cost, in Railways depot in the presence of the purchaser's representative and only the quantity of insulators which pass the tests and are finally taken over the contractor will form the basis for ) OTHER EQUIPMENT, FITTINGS AND COMPONENTS ‘The purchaser will supply the requirement of the various other equipments, components or fittings as per scope of work and special conditions of contract, If there is any shortage during final reconciliation, their cost will be recovered by the purchaser from the contractor at the prices inclusive of all charges as specified in note below. NOTE: 1. If there are any shortages during final reconciliation, their cost will be recovered by the purchaser from the contractor for excess material supplied by the Railways should be 1.5 times the cost of procurement which is inclusive of freight as per Railway Board Lr.No.94/CE.VUCT/4 41.17.9.97. (THIS PARA IS APPLICABLE ONLY IF ANY MATERIAL IS SPARED BY RLYS.) 2. No recovery/reconciliation shall however be made as per the preceding par as if the items stated under clause 1.6 are made contractor supply by including the respective optional items in the contract. SECTION 2: PARTICULAR 1 Notwithstanding anything to the contrary in this section, the entire requirement of the ‘equipment’s, components and fittings for the work of scope of work and special conditions of contract will not be supplied by the Purchaser to the Contractor. The price schedule shall be exclusive of cost of supply of such items. 2 In the case of wires, conductors, etc. The prices for erection shall include any assembly work to be done in the Contractor depot prior to erection at site, such as fabrication of droppers ete. to shapes and sizes required. 3 Explanatory notes are given below for all items given in schedule of prices for the guidance of tenderer. - General: By the differen . Feeders and return feeders from SCHEDULE-A (SOR-Items) ITEM No. 1 (a): Preparation of designs and drawings for overhead e« ment The price shall cover verification of purchasers engineering track plans indicating the layout of new lines with respect to the existing lines, which will be issued by the purchaser in stages. The preparation of layout plans and other design are to be finalized by the contractor in consultation and in close coordination with purchaser. ‘The contractor may be asked to prepare the layout plans based on the site details if the purchaser not able to supply the Engineering track plan. The rate shall be per TKM. The drawings are to be prepared in auto-cad software and also to be supplied in DVD media. 1 price shall include the following:~ Preparation of overhead equipment layout plans, for proposed tracks to be and modifications in Overhead equipment of existing tracks. ii) Preparation of cross section drawings and structure erection drawings for each structure locations (see para 2.5.6(1) & (h)). iii) Choice of type and size of foundations to suit soil and loading conditions, except for the once which are considered as “Works under other Agencies” (see para 1.2.37). iv) Preparation of long section drawings of overhead equipment where such drawings are required including detailed study of over line structures such as foot over bridges, road over bridges etc. for maintaining the specified height of contact wire and requisite clearances. ¥) Preparation of other designs and drawings including drawings of small parts steel work (other than those for which RDSO standard drawings are available) and detailed designs for booster transformer stations (sce para 1.2.23) vi) Supply of requisite no. of copies of all drawings, including completion drawings specified in part II, Chapter V to the Purchaser. vii) Preparation of Bonding plan drawings and supply of requisite no of copies. viii) This price shall also cover soil investigation and testing in an approved manner. ified Note: No pegging plans will be given to the contractor. NOTES FOR MEASUREMENTS: For the purpose of payment against this item, the length of track shall be measured as unde in the changes of the length under consideration, as incorporated in the layout plans, Turnouts: ‘The track taking off shall be deemed as starting from the toe of the switch of the Turnout. The length of track shall be taken as the difference in the changes of the toes of switches of the two tumouts constituting the crossover. |. Diamond crossing with or without slips: The two tracks crossing each other shall be measured independently as per note I above as though there were no crossing. No extra shall be provided for slip points. Dead ends and tops of loops: The lengths for payment under this item shall be up to the change of anchor mast of the terminating OHE. grid sub-station to feeding station: This item will also be applicable independently in case of feeders/return feeders/conductors from grid sub-station to overhead equipment feeding stations or in a case of feeders/conductors running on independent structures (not supporting OHE) along or across tracks. In such a case the length of line to be considered for purpose of item 1(a) shall be measured by the distance between the center of gantries of the grid sub-station and feeding stations, in case of feeder/return feeders/conductors line from grid sub-station, or by the distance between the center line of the two structures to which the feeders/return feeders/conductors are anchored, in case of feeders running along the track if such feeder/return feeders/conductors are running completely on independent structures or by the distance between the center of the two structures supporting the ONE on either side of the first and last independent structure in case of feeders/return feeders/conductors running along the track supporting OHE. ITEM No. 1 (b): Preparation of design and drawings for switching stations and feeding stations: The price shall cover on a flat rate basis per switching station, survey and preparation of fresh drawings duly incorporating the necessary additions/alterations required for addition of an interrupter along with other equipment, The price shall cover supply of detailed drawings like cross-section drawings, general arrangement drawings, detailed layout of equipment, bus-bar connections and insulators, layout of earthing system and earth connections, cable run layout and fencing layout, based on the drawings of the switching stations supplied by the Purchaser for the existing arrangement. The price shall include supply of requisite number of copies ofall drawings, including completion drawings. The drawings to be supplied in CD media also if prepared in digital form, ITEM No. 1 (c): Preparation of Station working rule diagram and _ station working instructions The payment under this item will cover preparation of Station working rule diagram and preparation of station working instructions .The station working instructions and rule diagram to be got approved ona tracing paper and six sets of the instructions to be supplied in blue print. RTE of the instructions also need to be supplied. Drawings shall be prepared in Auto-CAD format, same to be supplied in CD/DVD media. ITEM No. 1 (d): Supply and installation of SWR boards on flexi sheets (fixed on decolum sheet) at nominated places including supply of Power block caps ‘The payment under this item will cover preparation of Sectioning Diagram of Station on a4” X 3° size flexi sheet of suitable thickness and fixed on white Decolum plywood of 8 mm thickness and erecting the same at suitable location in the station master room or at any location nominated by Purchaser's engineer. The price covers supply of 8 numbers of power block caps. (For Each Station) NOTE: For item No. 1(e) to (h) above, soft copy of each drawing (in .pdf and also in dwg format) in CD is to be submitted as per Part-G. Item No. 1(c): Preparation of Designs and drawings for modification to existing traction substation, switching stations and feeding stations The price shall cover supply of detailed drawings like cross section drawings, general arrangement drawings, detailed layout of equipment, bus-bar connections and insulators, layout of earthing system and earth connections, cable run layout and fencing layout, based on the drawings of the traction sub stations, feeding stations and switching stations supplied by the Purchaser for the existing arrangement. The price shall include supply of requisite number of copies of all drawings, including completion drawings as specified in Part-II, Chapter V to the Purchaser (see para 1,2.23),The drawings to be supplied in CD media also if prepared in digital form, Item No. 1 (f): Preparation of Designs and drawings for traction substation The price shall cover on a flat rate basis per substation, survey, investigation of soil bearing pressure and soil resistivity, preparation of cross section drawings, preparation of general arrangement drawings, detailed layout of equipment, bus bar connections and insulators, layout of cable trenches outdoor and inside the control room, layout of earthing system and earth connections, layout of earth screen wire, design of supporting structures for 220kV, 132kV or 25kV equipments, detailed drawings for steel work and structural support, suitable concrete pedestals, plinths and foundations for equipment and structural support and drawings’ designs for equipments, components, fittings and materials, The price shall include supply of requisite number of copies of all drawings, including completion drawings to the purchaser as specified in PartIl ITEM No.1 (g): Preparation of Designs and drawings for upgradation of one bay of traction substation The Prices shall cover supply of designs and drawings required for Replacement of 12.5 MVA ‘Traction Power Transformer with 21.6/30.24 MVA Transformer with associated switchgear and control equipment in one bay at Traction Sub-stations. The price shall cover on a flat rate basis per bay , survey, investigation of soil bearing pressure and soil resistivity, preparation of cross section drawings, preparation of general arrangement drawings, detailed layout of equipment, busbar connections and insulators, layout of cable trenches outdoor and inside the control room, layout of earthing system and earth connections, layout of earth screen wire, design of supporting structures for 220KV, 132KV or 25kV equipments, detailed drawings for steel work and structural support, suitable concrete pedestals, plinths and foundations for equipment and structural support and drawings/ designs for equipments, components, fittings and materials. The price shall include supply of requisite number of copies of all drawings, including completion drawings to the purchaser as specified in Part-II ITEM No. 1 (h): Preparation of Designs and drawings for shunt capacitor banks The prices shall cover on a flat rate basis preparation of all designs and drawings required in connection with supply, erection, testing and commissioning of Shunt Capacitor equipment at the traction sub-stations. The price shall also cover on a flat rate basis cost of survey, investigation of Soil bearing pressure and soil resistivity, preparation of cross section drawing, general arrangement Drawings, detailed layout of equipments, bus bar connections and insulators, layout of cables situated out door and inside the control room, layout of the earthing system and earth connections layout, design of supporting structures, detailed drawings for steel work and structural support, suitable conerete pedestals and foundations tor equipments components, fittings and materials. The price shall include supply of requisite number of copies of all drawings including completion drawings to the Purchaser. The price shall also include supply of required number of designs, drawings, technical booklets and completion drawings as mentioned in part II ITEM No. 2 (a) (i) Concrete for foundation and plinth in hard soil {i) Concrete for foundation and plinth in rocky soil ‘The price shall cover excavation, supply and handling of all materials, and accessories, temporary arrangements for excavation in hard soil and conerete/masonry drains/walls requiring use of chise] and hammer 2 (a) (i) or requiring blasting 2 (a) (ii), Shoring where necessary, casting concrete including frame work where necessary, tamping of concrete, grouting of masts and finishing the top of conerete foundation or anchor blocks. The price also includes dismantling of all connected temporary arrangements, back filling with earth and compacting the same to the required height and width as per drawing to ensure safety of foundation, confining the exposed height of foundation block to within 10 cm., and removal of soil. ‘The Purchaser's Engineer shall certify where use of chisel and hammer or blasting has been necessary. The contractor shall arrange for supply of explosives and all tools and plants for blasting operations at his own cost. If half or more of the depth or width of excavation is in hard soil/eonerete/masonry drains/walls or in rock, the entire foundations shall be paid for under item 2(a) (i) or 2 (a) (ii) as the case may be. If half of the depth or width of the excavation is in hard soil/conerete/masonry drains/walls and the other halfis in rock, the entire foundation shall be paid under item 2 (a) (ii). The price shall include the cost of cement. Notes for measurement for items 2 (a) (i) and (ii) 1. The payable volume of the foundations under item 2 (a) (i) and (ii) shall be the designed one as shown in the drawings for which the hole has been blasted, irrespective of the actual configuration assumed by the latter due to the blasting. 2. The depth of the excavation shall be measured from the formation level to the maximum excavated point. ITEM No. 2 (b): Concrete for foundation and plinth in other than hard soil and rock, including foundations for AT/BT Masts ‘The price shall include all works mentioned in item 2(a) in all classes of soil except hard soil, 1 or masonry drains and walls and rock. The price shall also include foundations for AT/BT M No. 2 (c)(i): Reinforced concrete for foundation, plinth and cable trenches ‘The price shall cover excavation and all reinforced concrete work for foundations including supply of steel for reinforcement and other materials including bending, binding, laying of the reinforcement, shoring where necessary casting conerete including framework where necessary, ‘grouting and finishing the tops of foundation blocks. The price shall also include dismantling of all connected temporary arrangements back filling as required and removal of soil. The price shall also cover all conerete work for foundation or anchor blocks on bridge piers, irrespective of whether they are actually reinforced or not, and those for cast-in-situ piles foundation and counter weight foundations. Rails and fasteners required for counter weight foundations shall be supplied by the Purchaser free at the Contractor’s depot or work spot according to convenience of the Purchaser. ‘The volume of cast-in-situ piles shall be added to the volume of foundation block for the purpose of payment. Dowel bars as may be required for bond with bridge structures shall be supplied and erected free of cost by the Purchaser. Dowel bars will not be considered as reinforcement for the purpose of this item. The price shall also include the cost of cement. ITEM No.2 (c} ible trench covers [M15 grade] The price shall cover costing of cable trench covers in reinforced concrete as per drawing. The cable trench covers will be casted on angle iron frame of angle size 40mmx40mmxSmm. The price shall include the supply of steel for reinforcement angle iron for the frame and fabrication of angle iron frame ete. The price shall include positioning and dressing up of trench covers, if required. The price shall include the cost of cement also. Cement will not be supplied by Railways. NOTE: Nominal reinforcement will be necessary in black cotton soil foundations. Such nominally reinforced foundations in black cotton soil will be payable under item 2(b) and not under item 2(c). ‘The steel for nominal reinforcement will be arranged by the Contractor and the concrete mixture, in such a case shall be as for normal foundations 1:3:6 (see Para 2.2.4 at Section-7 of Part-D). ITEM No.2 (d) (i): Reinforcement brick work ITEM No.2 (d) (ii): Plastering of brick work ITEM No. 2 (e) : Extra for supply & sinking of conerete shells [M-15 grade The price shall cover on items 2(a), (b) and (c) for supply and sinking of a concrete shell before casting of conerete for traction structure foundations or anchor blocks including pumping of water where necessary. Purchaser’s Engineer shall decide whether sinking of concrete shells is necessary. NOTE: The above price shall be per concrete shell of standard size specified in Para 2.2.7 at Section-7 of Part-D. If more than one concrete shell is used in a foundation, the price shall be proportionately augmented. ITEM No. 2(f): Casting of Foundation using mechanised Augur [M-15 grade] The price shall cover excavation, supply and handling of all materials including supply and erection of steel for reinforcement, accessories/temporary arrangements and all associated operations for casting of foundations by mechanized Augur in all type of soils except rocks. All machines, tools and equipment needed for the above shall be supplied by the Contractor at his own cost. The price shall include the cost of cement. NOTE: 1, The payable volume of the foundation shall be the designed one as shown in the drawings for which the pit has been excavated irrespective of the actual configuration assumed by the latter after auguring. 2. The depth of the excavation shall be measured from the formation level to the maximum, excavated point. ITEM No. 2 ‘asti lc under reamed Pile Foundation [M-15 de} The price shall cover boring of hole for under reamed pile as per RDSO Drg. No.ETU/C/0062 which is having dia. of 300 mm or if any sizes as approved by Purchaser required for cast-in-situ pile foundation including difficult location like low lying areas near river, ponds or at any other location of which foundation is not covered under item No. 2(a) to 2 (f). The price shall also cover the charges of pumping set required for draining of water encountered while boring the holes, cost ‘of compressor or any other machine required for breaking of brick apron or any other hard strata if it is coming in way of boring of holes. The price shall also cover the casting of concreting of ratio 1:2:4 mix 20mm graded stone or downgraded and cost of shuttering and its removal and cost of any other item which is encountering during course of boring and casting of pile. The price shall also cover the cost of cutting, bending and laying of reinforcement but excluding the cost of steel required for reinforcement which has been covered under item 3(g). The price shall also cover the cost of all other materials including cement required for the work. ‘The work shall be executed strictly in accordance with IS-456/2000, The price shall also cover the cost of transportation (to and fro) of all materials, tools and plants required for the work. The p shall cover the cost of compactness the concrete with the help of Electrical/Mechanical vibrator. The price shall also cover the sereening and washing of concrete. The price shall also cover the cost of consumable like fuel, oil, wedges, string rope etc., required for the finishing the work. The cost of full volume of RCC pile cap and RCC column upto Rail level height more than one meter on top of piles shall be covered under item 2(h)(i), however for heights, less than one meter the rates of item 2(c) shall be applicable ITEM No. 2(h)(i): Reinforcement cement concrete 1:; in column with 20 mm and downgraded stone aggregates and coarse sand ‘The price shall cover the cost of reinforcement cement concrete work for construction of column including supply of cement, concreting, shuttering arrangements and dismantling thereto but excluding cost of steel required for reinforcement which has been covered under item 3(g). The price shall cover cutting, bending and lying of reinforcement in column. The concrete mixture shall be of 1:2:4 ratio and casting of the same to be done in accordance with IS: 456/2000. The item shall cover any requirement of concreting in the special foundation design which has not been covered under item 2(c) or where foundations are required to be projected above ground level to the extent of more than 1 meter, and shall be operated for the work of foundation or OHE supports only. ITEM No. 2(h)(ii): Reinforcement cement concrete, ratio 1:3:6 in pile caps with 20 mm and downgraded stone aggregates and coarse sand. ‘The price shall cover the cost of reinforcement concrete work for construction of pile caps including supply of cement, concreting, shuttering arrangements and dismantling thereto but excluding cost of steel required for reinforcement which has been covered under item 3(g). The price shall cover cutting, bending and laying of reinforcement in column. The concrete mixture shall be of 1:3:6 ratio and casting of the same to be done in accordance with IS: 456/1978. ITEM No. 2(h)(iii): Mass concrete (PCC) ratio 1:4:8 with nominal size stone aggregate 40mm and ordinary sand in Mud-mat The price shall cover the cost of all materials e.g. 40mm graded stone aggregate, sand, cement, arrangement of water and necessary tools and plants. The price shall be inclusive of shuttering arrangement, cutting, leveling, finishing ete. The price shall cover the cost of transportation (to and fro) of all materials, tool and plants ete., and handling/re-handling of materials atthe site. The price shall cover the screening and washing of concrete. The price shall also cover the cost of consumable materials like fuel, oil, wedges, string rope etc. required for the work, ITEM No. 2(h)(iv): Concrete for foundation of Height gauges at L.C gates: The price shall cover excavation, supply and handling of all materials and accessories including ‘cement, temporary arrangement in hard soil, shoring where necessary, casting concrete including frame work where necessary, temping of concrete, grouting of upright of height gauges, and finishing the top of concrete foundation, The price also includes dismantling of all connected temporary arrangements, back filling with earth and compact the same to the required height and width as per drawing to ensure safety of foundation. Foundations to be cast strictly in accordance with drawing No, RE/Civil/92-84 R2, The rates are exclusive of erection of upright/booms of height gauges as the same has been considered in the item No.3 (h) (ii) ITEM No. 2(i): Alterations to the existing foundations Alterations to the existing foundations to suit the mounting of Interrupters/CB’s ete duly drilling holes, providing suitable size bolts wherever required at each location. ITEM No. 3(a): Erection of traction masts and main masts of Switching stations, Booster Transformer Stations and LT supply transformer stations The price shall cover cost of erection, alignment, and setting before grouting of individual traction masts and main masts of Switching, LT supply transformer station, Booster Transformers stations Feeding post & TSS whether rolled or fabricated. NOTE: For the purpose of payment, the weights of individual traction mast shall be determined for each type on the basis of the payable weights per meter length shown below for standard types, For special types, the payable weight per meter length will be indicated by the Purchaser at the time of approval of designs. SLNo | TYPE OF MAST WEIGHT IN kg, per meter including galvanization. @x6"x25.15 BFB 38.03, 162x154x27.1 kg. BEB _ | 38.00 200x200x49.9 kg. BFB_ [$1.20 8"x6"x35 Ib. RSJ 53.39 =] )s) 5 SI 53.39 G Sa 76.40 7 S4 53.39 8 SS 111.53, 9 S6 53.39 10 S7 76.40 UW S8 111.53 12 K 100 23.70 3 K 125 30.30 14 K 150 38.18 15 K175 43.72 16 K 200 49.87 17 K 225 37.50 18 K 250 66.72 19) B 100 27.71 20 B 125 32.47 21 BI50 39.07 22 BATS 44.61 23 B200 50.76 24 B 225 61.50 25 B 250 70.72 26 ‘S100 23.72 27 S101 19.98 28 T1S0 38.18 ‘The payable weight per meter length for the above mast will be indicated by the Purchaser at the time of approval of design. ITEM No. 3(b) & (c): Erection of fabricated steel work such as TTCs, Portals, SPS ete. The price shall cover, cost of erection, alignment and setting before grouting, wherever required, of portals, gantries, 2/3 tracks cantilever structures including cantilevers and tower/steel work for feeders for traction sub-station, drop arms, standard super masts and suspension brackets for feeders and return conductors, dwarf masts or stub masts for anchoring, complete with anchor plates drilled and welded in position, multiple cantilever cross arm, chairs, adaptors for bracket assemblies and all other small part steel works, the erection of which is carried out by the Contractor irrespective of whether they are supplied by the Purchaser or the Contractor. The prices shall also include supply and erection of galvanized bolts, nuts washers etc. wherever required as per approved designs and drawings. Note for Item 3 (a),3 (b) & 3 (c): The price for the items 3 (a) and (b) shall also include the cost of steneiling of location number on masts/portal uprights in the manner as directed by the Purchaser. The price shall also include the straightening of masts/portal uprights bent during transit and cutting of masts/portal uprights to suit the site conditions. Notes for Items 3 (b): 1. Forthe purpose of payment against items 3(b) weight of structures or fabricated steel work will be calculated according to the weight of black steel given in section books for the lengths of various members shown in the approved drawings. There will be no addition for increased weight due to galvanizing or painting or weld material or reduction for holes or skew cuts, 2. The rates against item 3(b) shall be applicable to the erection of small part steel work, which are not covered under the various other items of work. Unless specifically indicated none of the other items of work shall include the cost of supply and/or erection of small part steel work, which will invariably be paid for under item 3(b) or 3(c) as applicable. ITEM No. 3 (d): - DELETED - ITEM No. 3 (e): Supply and erection of a guy rod assembly ‘The price shall cover supply and erection of guy rod assembly of various lengths for traction masts, feeder line towers or supports complete with mast guy rod fittings, guy rod with adjustments and part/s be grouted in the anchor block complete with bolts and nuts ete... The price shall not include the cost of supply and erection of a dwarf or stub mast with anchor plates drilled and welded in position, where required, for anchorage, and small parts steel work, if any for attaching the mast ‘guy rod fittings to the mast/strueture which shall be paid for separately under the relevant item. Prices indicated against all other items should be exclusive of the price of supply and erection of guy rod, if any, which will be paid for under this item. COMPONENTS REQUIREMENT Rly. 1D No. __| Description of components ‘Qty.per unit 3232 Mast guy rod fitting (welded) complete with 4 short bolts | 1 off nuts, locknuts and washers for attachment to masv/S.P.S including appropriate fittings 3001/5001- | Anchor bolts TSet 1/5001-3, (complete with nuts locknuts and_split pins) 3002 Guy rod stirrup Toff 5004 or 5005] Guy rod with nut, washer and split pin Toff or 5006-1 or 9070 or 9071 5007-1 Anchor ‘Vv bolt 2off 3008 ‘Anchor loop 2off 5220 Guy rod double strap Toff or 2 off assembly {as required) NOTE: 1. Incase the Contractor desires to adopt a different design for guy rod assembly, the same shall be indicated by him in the Tender and the components required should be clearly listed under this item as deviation 2, Supply and erection of guy rod assembly at anti creep portals will also be paid for under this item. ITEM No.3 (g): Supply of steel reinforcement for RCC work he item covers the price of supply of tested quality of steel for reinforcement of appropriate size and for reinforcement steel above 8 mm or suitable dia shall be High strength deformed steel bars conforming to IS:1786/1985 and below 8 mm dia, shall be mild stcel and medium tensile steel bars conforming to 1S:432(Pt. 1) /1982. Price shall cover the all taxes and duties i.e., Excise Duty, Sales Tax, Freight ete. However, the cost towards cutting straightening hooking, bending, erecting and placing and keeping in position including all lead and lift and including cost of binding wire shall be inclusive in item 2(h)(i), 2(h)(iii) respectively. Test certificates for steel will be furnished by the contractor at his own cost form a laboratory approved by the Engineer-in-Charge. Nothing extra will be paid for unauthorized overlaps and wastage of steel involved in cutting the bars to their required sizes. ITEM No. 3(h) Concrete for foundation of height gauge The price shall cover excavation, supply and handling of all materials and accessories including ‘cement, temporary arrangement in hard soil, shoring where necessary, casting concrete including frame work where necessary, temping of concrete, grouting of upright of height gauges, and finishing the top of concrete foundation. The price also includes dismantling of all connected temporary arrangements, back filling with earth and compact the same to the required height and width as per drawing to ensure safety of foundation, Foundations to be cast strictly in accordance with drawing No. RE/Civil/92-84 R2. The rates are exclusive of erection of upright/booms of height gauges as the same has been considered in the item No.3 (h) (i Item No.3 (h)(ii) : Erection of height gauge at level crossing gates The item covers erection of height gauges at either side of the Railway track as per drawing No.RE/Civil/92-94-R2. The foundation of the upright shall be covered under item 3(h)(i) of Sub- section-2 of Schedule-I Section-1. Only erection portion of steel Rails/Boom/Fabricated Structures/RSJ shall be covered under this item. The horizontal member Rail/Boom/Fabricated RSI shall be provided with a danger board as per drawing No.ETI/C/0069. Upright members shall normally be old Rails, whereas the horizontal member shall be old rail, section or fabricated beams. These upright or horizontal member may be rail section/fabricated steel beams structures / RSJ tubular length of suitable sizes to be supplied by Railways. ‘The upright and horizontal member posts shall be supplied to the contractor free of cost at suitable place by Railways. Price shall be inclusive of transportation charges from the place of availability to the contractor's depot and fabrication charges such as drilling of holes for fixing of Danger board and horizontal members with the upright members, Price shall include cutting of rails to required sizes for upright/horizontal members ete, Price shall also cover the price for erection of protective Rail posts/Rail guards. The price shall also cover the painting of the height gauges as per standard drawing including cost of paint (primer and paint both). ITEM No33 (i) : Supply and ere n_boards/ plates ‘The price shall cover price of material including Caution Boards, SPS items, nuts, bolts ete. as required and erection charges Caution Boards shall be of two types. 1 General Caution Notice at entrance to Railway station (Telugu, Hindi & English) No.ETVOHE/G/7 551 Mod-C. 2. Caution Plate 25000 V. No. ETI/OHE/G/7531 Mod-C. Price shall be inclusive of Sales tax, Excise duty, Freight etc, Boards shall required to be installed on a steel structure/Rail post/wall of a building therefore mode of erection shall be as per requirement of the site. ITEM No. 3(j): Supply and erection of Protective screens on ROB/FOB [OR] nearby crossing path The supply and erection of protective screens on ROBS/FOBs nearby crossing path. The price shall cover on per track basis on both sides of ROB/FOB OR nearby crossing path. The cost of all ‘material required for fabrication of protective screen including angle, TEE, Expanded metal (Jail), Glsheet, paints etc. The price shall also include the labour cost for fabrication; erection work shall be done as per RDSO Drg. No.ETI/C/0068 Mod-E. ITEM No. 4(a)(i): Supply without insulator and Erection of a single bracket assembly for conventional OHE The price shall cover on a flat rate basis any bracket assembly on a traction mast or support on drop arm and shall include those on high/low level platform, in the vicinity of turnouts, over bridges or over-laps and at locations with reduced encumbrance or terminating wires. The price shall include the cost of supply of all components including galvanized steel tube complete with bolts and nuts etc but excluding solid core insulators (Id.nos, 6000 and 6030), dropper wires and small parts steel work if any. The price shall cover erection of all components including solid core insulators and dropper wires, but excluding small parts steel work, if any. However, this does not include the antiecreep arrangement at masts/ structures. The price shall include: Rly. 1D No. Description of components ‘Qty. per unit 3020 Mast fitting for hook insula tor with 2 off bolts, nuts, 1 set locknuts and washers of 16 2400 Tubular stay arm assembly Tset (including galvanized steel tube), 210-1 ‘Catenary suspension bracket assembly or hook bracket | 1 off 2130/2380 1160/21207 Suspension clamp Toff 2140 (as required) 2040 oF 2080 | Bracket tube assembly complete with tube cap and sleeve | I set where required (including galvanized steel tube), 3070-172 Mast bracket fitting assembly including 2 off bolts, nuts, | 1 set Jock nuts and washers of 16 for attachment to structure or to small part steel work. 2150-1 oF 2160-1 | Register arm hook assembly complete with bolts, nuts| 1 off and lock nuts. 2420 or 2430 | Register arm assembly or raised register arm assembly | 1 set (including galvanized steel tube). 2270-4 or _5/| Register arm dropper assembly excluding dropper wire, | 1 set 2460 _style-2| but complete with bolts, nuts e 2470 style-02 7390/2540) BFB steady arm or bent steady arm ‘As required 2520 (where required) 236072490-2 | 25 mm steady arm drop brackevelamp =do- 1220/1370-1__ | Contact wire swivel clip or raised register arm clamp | 1 off 2550-12 ‘Anti wind clamp ‘As required - M.S, Stay and bracket arm fittings for P.S.C. masts set each, ITEM No. 4(a) (ii): Extra on 4(a) (i) Extra for supply and erection of additional fittings on a single bracket assembly for supporting two O! The price is applicable as an extra to item 4(a) (i) for the provision of additional fittings required to support an additional OHE on a single bracket assembly payable under item 4(a)(i). The price shall include supply of all extra fittings exeluding the double contact wire swivel clip. The price shall include erection of all extra fittings, including the double contact wire swivel clip. ITEM No. 4(a) (ii): Supply without insulatoré& erection of a single bracket assembly suitable for tramway type overhead equipment (regulated) The price shall cover on a flat rate basis any bracket assembly, on a traction mast or support on drop arm, and shall include those on high level platform, in the vicinity of turnouts, over bridges or over-laps and at locations with reduced encumbrance or terminating wires. The price shall include the cost of supply of all components including galvanized steel tubes complete with bolts and nuts etc but excluding solid core insulators. (Id. Nos. 6000 and 6030), dropper wires and small parts steel work, if any. The price shall cover erection of all components including solid core insulator, and dropper wires, but excluding small part steel work, if any. However, this does not include the anti creep arrangement at masts/structures. The price shall include Rly. 1D No. Description of components Qty. per unit 3020 ‘Mast fitting for hook insulator with 2 off bolts, nuts, locknuts| 1 set and washers of 16 mm 2400 Tubular stay arm assembly (including galvanized steel tube). 1 set 2403-1/2402_| Tubular stay sleeve with Adjuster Tset 2380 Hook bracket Tset 2140 Large catenary direct clamp 1 set 2160-1 Large register arm hook 1 set 2080 Large bracket tube assembly (F49 mm) (including galvanized Tset steel tube) 3070-172 Mast bracket fitting assembly including 2 off, bolts, nuts, Tset Jocknuts and washers 16 mm f 2540-1 BEB steady arm assembly 1 set 2550-3, ‘Standard Anti wind clamp I set 1220 Contact wire swivel clip set - MS. Stay and bracket arm fittings for P.S.C. masts 1 set each ITEM No. 4(a)fiv): Extra on item 4(a)(iii) for supporting two tramway type OHEs (Regulated) The price is applicable as an extra to item 4(a) (ii) for the provision of additional fittings required to support an additional OHE on complete bracket assembly payable under item 4(a)(iii). The price shall include supply of all extra fittings, excluding the double contact wire swivel clip. ITEM No. 4(a)( : SUPPLY without insulator and erection of a single bracket assembly for Same as for item 4(a)but with the following changes. Aluminium catenary suspension clamp Assembly (MCI) as per Drg No. ETI(OHE/K/468 (MOD-A) to be used in lieu of Id.No.1160, Aluminium copper strip to be used with Id.No.2120/2140 direct catenary clamps jupply without insulator and erection of pull-off arrangement for one ‘The price shall cover supply of all components required for a pull-off arrangement to pull one equipment only including head-span mast fittings complete with M.S. angle, equalizing plate assembly, steady-arm, catenary, conductors, small swivel clip and fittings but excluding solid core insulators, conductor, small jumper (50 sq.mm). The price shall cover erection of all components including solid core insulators, small jumper wire and conductors. NOTE: For composite OHE’s a catenary dropper clips with necessary bimetallic strip/washer to be used in place of eatenary dropper clip (Id No.1192). ITEM No. 4(b ment pulled The price shall cover as an extra to item 4(b)(i) or 4(b)(iv) supply and erection of all additional fittings required in case the pull off pulls more than one equipment. The prices applicable for each extra equipment pulled. ITEM No. 4(b)(iii): Supply without insulator and erection of a pull-off arrangement for regulated Tramway type OHE ‘The price shall cover supply of all components required for a pull-off arrangement to pull one ‘equipment only, complete with steady arm, contact wire swivel clip and fittings but excluding the cost of solid core insulator (RI No.6020) and conductor. The price shall cover erection of all components including solid core insulators, small jumpers and conductors. ITEM No. 4(b)(iv):Supply without insulator and erection of a pull-off arrangement for one composite OHE, Same as item 4(b)(iv) except that + Instead of copper dropper clips (Id.No.1192) aluminium alloy dropper clips as per Drg No.ETI/OHE/SK/130 Mod(D) shall be used. - Aluminium copper bimetallic strip shall be used with fittings as necessary. + Also instead of ID1160 Aluminium bronze eatenary suspension clamp, MCT suspension clamp as per Drg No.ETI/OHE/SK/168 Mod (A) shall be used for aluminium alloy catenary. Su; arrangement for span shall cover supply of all components including adjusters, terminal fittings and mast attachments required to attach a span wire or a head-span wire or a cross span wire or a steady span wire or a support span wire for supporting contact wire only, at both ends, to traction masts/ structures or special brackets. The price shall exclude the cost of solid core insulators and small parts steel work, if any. The price shall cover erection of all components including mounting arrangements for span wire and solid core insulators but excluding small parts steel work, if any. ITEM No. 5 (a) (ii): Erection of a span wire The price shall cover supply and erection of a span wire per metre. The payable length shall be the horizontal distance between the inner faces of all traction masts/structure on which the mast attachments are mounted. No extra shall be provided for sag. The price is applicable forall types of span wires including Head Span Wires. Erections of a metre beyond the first decimal shall be rounded off to the nearest first decimal. TEM No.5 (b): Supply without insulator and erection of suspension of one conventional OHE/composite OHE from head span The price shall cover supply of a suspension assembly to carry complete all copper OHE/Composite OHE on head spans inclusive of all dropper assemblies (exclusive of dropper wire) and from head-span, cross-span steady wire attachment, steady armv/rod, catenary suspension clamps and other fittings required to make complete suspension arrangements for copper OHE/Composite OHE on head span. The price shall cover the erection of all components, fittings, and droppers for suspension of OHE from head span. ITEM No. 5(c): Suspension /registration of contact wire only The price shall cover supply and erection of all fittings required for suspension/registration of a contact wire only whether under head spans carrying other types of OHE or not on any bracket for carrying contact wire only. The price shall inchide the followings:- (i) Vee clamps or double vee clamp with adjuster, or steady arm with st (i) Contact wire swivel clip. ly wire Clamp. ITEM No. 6 (a): Supply and erection of overhead equipment only The price shall cover supply of all components including dropper clips, parallel clamps for jumpering, galvanized steel wire at terminations if any, and splices (where their use is approved) complete with bolts and nuts etc for attachment of number plates to mast/structure.if any ,but excluding contact wire,catenary, dropper wire, jumper wire and terminating wire/s and small parts steel works. The price shall cover erection of all components and wires and conductors including contact wire, catenary,droppers jumpers and galvanized steel wire or terminating wires,ifany, but excluding small parts steel work, if any. The price shall include provision of enamelled number plates on traction masts or structures complete with bolts and nuts .The prices shall exclude supply of all parts steel work for attachment of enamelled number plates to masts/structure, The price shall also include the cost of painting the setting distance of masts/structures, EC socket direction, tension length at ATD locations, stenciling of number on three sides of mast and rail level (ERL and MRL) on masts/structures. The price shall not include termination of conductors which will be paid for under item 8. Rly. ID No. Description of components Qty.per unit 1040-2 | Contact wire parallel clamp small, ‘As required 1180 Contact wire dropper clip (107) ~do- 1192 Catenary dropper clip complete with bolts,nuts ete =do- 7501 Enamelled number plates complete with 2 Galv. MS. bolts ~do- #10x35/30, nuts and lead washer for f 10 bolts but excluding SPS for attachment of number plate to masts/structures. 1110-2 Contact wire ending clamp =do- 1120 or 1120-1 | Catenary ending clamp =do- 1140 Large span wire clamp (130) =do- [5020- 5020-2 | Adjuster _-do- 5030 Anchor double strap assembly -do- 3191/5192 | Compensating plate/equalizing plate. =do- - Galvanized steel wire at terminations, =do- NOTE: i ‘Wherever necessary with higher section contact wire of 150 sq.mm, the items required are to be provided suitable for higher section contact wire of 150 sq.mm ii, If“G" jumper of 160 sq.mm is used at UIOL, then PG clamp 1031-3 is used, ITEM N: ‘ection of contact wire only The price shall cover erection of contact wire only. The price shall exclude termination which will be paid for under item 8. The price shall include provision of enameled number plates on traction ‘masts/structures complete with bolts and nuts. The price shall also include the cost of painting the setting distance of masts/structures, EC socket direction, tension length at ATD locations, stenciling of number on three sides of mast and rail level (ERL and MRL) on masts/struetures. The price shall exclude the supply of small part steel works for attachment of enameled number plates to masts/structure. Rly. ID No. Description of components Qty.per unit 1040-2 |Contact wire (107 sq.mm)/(150 sq.mm ) To be supplied by th urchaser [Enameled number plates complete with fastenings fs required Note: During the replacement work of existing 107 Sq.mm contact wire wherever necessary with higher section contact wire of 150 Sq.mm, the items required to be replaced are: a. Contact wire ending clamp (1110-2) of standard section contact wire of 107 Sq.mm needs to be replaced with higher section contact wire ending clamp (Clamp body 1791 + 1792 thimble), b. _ If*G” jumper of 160 Sq.mm is used at UIOL, then PG clamp 1031-3 is to beused ITEM No. 6(c): Erection of contact wire only (regulated with briddle wire) ‘The price shall cover erection of contact wire only. The price shall exclude termination which will be paid for under item 8. The price shall include provision of briddle wires with clamps and two droppers including clips enamelled number plates on traction masts/structures painting of setting distance of masts/structures and rail levels on masts/structures complete with bolts and nuts. The price shall exclude the supply of briddle wire, dropper wire and small part steel works for attachment of enamelled number plates to masts/structures. The price shall also include supply and erection of galvanized steel wire or terminating wire at terminations. ITEM No. 6(4): Supply and erection of composite overhead equipment only ‘The price shall cover supply of all components including dropper clips, parallel clamps for jumper and splices (where their use is approved). But excluding contact wire, catenary, dropper wire, jumper wire and terminating wires small parts steel works complete with bolts and nuts ete. for attachment of number plates to mast/structures, if any. The price shall cover erection of all components and wires and conductors including contact wire, catenary, dropper, jumpers and terminating wires, if any, but excluding small parts steel work, if any. ‘The price shall include provision of enameled number plates on traction masts or structures complete with bolts and nuts, The prices shall exelude supply of small parts steel work for attachment of enameled number plates to masts/structures, and rail level on masts/struetures. The price shall also include the cost of painting the setting distance of masts/structures, EC socket direction, tension length at ATD locations, stenciling of number on three sides of mast and rail level (ERL and MRL Jon masts. The price shall not include termination of conductors which will be paid for under item 8, Rly. ID No. Description of components (Qty.per unit 1040-2 or SK- ‘Contact wire parallel clamp(small) bimetallic parallel _| As required 534/1 & SK-575/2_| grooved clamp assembly as per Dg or SK-576/I/1& | ETVOHE/SK/123 (MOD-C) SK-535/2 Or 1041-3 No. 1180/SK- Contact wire dropper clip (107) Aluminium alloy | As required 572/18 SK- catenary dropper clip Assembly complete with bolts, 572/2 nuts, Split pin, bimetallic (Aluminium/copper) Washers ete as per Drg. No.ETVOHE/ SK/333 (MOD- © 1110-2 ‘Contact wire ending clamp Aluminium Alloy catenary | As required ending clamp as per Drg No. ETIV/OHE/SK/436 (MOD-A) or any other Type as approved by the purchaser 1140 large span wire ending clamp As required 3020-1/5020-2 Adjuster ‘As required 5030 ‘Anchor double strap assembly unequal Tension As required ‘compensating plate as per Drg No. ETV/OHE/P/5191- 1/2(MOD-C) 7501, 7502 Enameled number plates complete with 2 Galv. | As required Ms.bolts m 10x35/30, Nuts and lead Washer for m 10 bolts but excluding SPS for attachment of number plates To masts/structures. NOTE: All bolts and nuts below 14mm dia on current carrying parts of composite OHE shall be of stainless steel Note for Measurement ‘or the purpose of payment against item 6(a), (b) and (c), the length of over head equipment, which shall include terminating wires and galvanized steel wire, shall be measured from the centre lines of the traction masts/structures at which the two ends of each tension length of over head equipment are anchored. 2. The length shall be the difference between the actual chainages of the two traction masts/structures at which the ends of each tension length are anchored or by the sum of the actual spans between the same two points whichever is higher as included in the “as erected” layout plans. For purpose of progress payment reference to layout plans as approved shall be made. The price under items 6(a), 6(b), 6(c) & 6(d) does not cover the cost of supply and erection of cut insulators, the supply and erection of which shall be paid for under item 11 ITEM No. 7 (a) : Erection of all Aluminum 25 KV feeder/Return conductor (single spider) The price covers erection of 25 KV feeder/retum conductors (along or across tracks) made a single all aluminum bare, hard drawn conductors 19/3.99 mm (SPIDER). The price does not include the cost of suspension assembly (which will be paid for under 11) and termination (which will be paid under 8) and small part steel work, complete with bolts and nuts ete., if any. The price also covers ona flat rate basis, the cost of supply of splices to the extent required. The price excludes the cost of 19/3.99 mm (spider) conductor. Released R.C. in pieces will be supplied by the Railway Necessary splicing to be made. This may be taken into consideration while quoting the rates. ITEM No. 7 (b): - DELETED - ITEM No. 7 (c): Supply and erection of earth wire The price shall cover supply and erection of earth wire made of 7/4.09 mm steel reinforced aluminium conductor (RACCOON) excluding termination which will be paid for under item 8 and shall include cost of fittings on structures for supporting the earth wire including bonding of the carth wire to the structure and the structure to earth electrodes ora nonetrack circuited running rail ‘orimpedance bond which will be provided by the Purchaser. The price shall include disc insulators cut-in to isolate sections of earth wire which will be paid for under item 11(¢) and the cost of small part steel works complete with bolts and nuts to attach the earth wire mast clamp to masts/structures, if any. Notes for Measurements 1 The prices under items 7(a) and (b) shall not include. i) termination which will be paid for under item 8. the connection (a) between feeders, or return conductors and (b) of feeders, or return conductors to a bus bar, overhead equipment or isolator switch which will be paid for under item (15); and Iii) cutein-insulators and suspension insulators which shall be paid for under item 11. 2. For the purpose of payment against item 7 (a) and (b) the length of feeders, return conductors or earth wire shall be measured from the centre lines of the mast/structure at which the two ends of each length of feeder or conductor run are anchored, by adding actual spans. In case of feeders/return conductors crossing a track, the length shall be measured between the faces of traction masts/structures at which the two ends of the cross feeder or return conductors are anchored, as indicated in the as erected structure erection drawings for traction masts/structures. For purposes of progress payment reference to “as approved drawings” shall be made. ITEM No. 7(d): Manual erection of all Aluminium 25KV Feeder/Return Conductor (Spider) ‘The price covers Manual [instead with wiring train] erection of 25 KV feeder/retumn conductor (along or across tracks) made a single all aluminium bare, hard drawn conductor 19/3.99 mm (SPIDER). The price does not include the cost of suspension assembly (which will be paid for under 11) and termination (which will be paid under 8) and small part steel work, complete with bolts and nuts etc., if any. The price also covers on a flat rate basis, the cost of supply of splices to the extent required. The price excludes the cost of 19/3.99 mm (spider) conductor. Released R.C. in pieces will be supplied by the Railway. Necessary splicing to be made. This may be taken into consideration while quoting the rates. ITEM No. 7(e): Erection of copper cross feeder wire (37/2.25 mm HDBC 150 Sq.mm) The price shall cover the supply and erection of 25KV feeder wire across/along the track at the location of SP/SSP/FP/BT/Granites stations. Feeder wire shall be made of Hard drawn bare copper conductor of size 37/2.25mm, 150 Sq.mm. Drop jumpers/Jumpers from this wire shall be of 150 sq.mm wire with 1050-3 PG clamps which will be paid under 15 (A) The price shall be exclusive of supply cost of feeder wire (which will be paid under 7(e) — Shedule - B) , termination (which will be paid under item 8(b)(ix) and small parts steel work complete with bolts, nuts ete if any. ITEM No. 8(a}(i) to 8 ly and erection of r DELETED ITEM No. 8(a)(v): Supply and erection of regulating equipment (3 pulley type) with counter weight assembly for conventional OHE The price shall cover supply and erection of counter weight assembly including 5 tonne adjuster with double strap assembly and normal/anti-thefi guide tube assembly, the supply of regulating ‘equipment and stainless steel wire rope required for the regulating equipment and small part steel work, if any. The price shall also cover adjustment of the entire regulating equipment. The price shall not include supply and erection of termination, which will be paid for under item No. 8 (b).. Note: ‘The regulating equipment shall provide one extra mast anchor fitting below the existing mast anchor fitting as per RDSO drawing No, TI/DRG/OHE/ATD/RD$0/00009/06/0 and follow the arrangement of modified anti. falling rod as pet ~RDSO Drg. No. TVDRG/OHE/ATD/RDSO/00001/99/2. ITEM No. 8(a) (vi): Supply and erection of regulating equipment (3 pulley type) with counter weight assembly for tramway type OHE (regulated) Same as 8(a)(v) above but with counter weight assembly conforming to style 01 of the relevant termination arrangement drawing No, ETI/OHE/G/04212 (Rev.B). ITEM No. 8(a) (vii): Extra for regulating equipment with trapezoidal counter weights for tramway type OHE The price shall cover, as an extra on item no. 8(a) (Vv) & (vi), the additional cost of erection of regulating equipment with trapezoidal counter weight assy. in place of normal counter weight assy. ‘The price shall cover supply and erection of components including trapezoidal counter weight assembly, the guide tube assy. including two guide tubes, but excluding the small part steel work. ‘The Price shall not include supply and erection of terminations which will be paid under item no, 8 (b). ITEM No. 8(a)(ix): counter weight Same as item 8(a)(iv) but excluding stainless steel wire rope required for the regulating equipment. Supply and erection of a regulating equipment with cement concrete ITEM No. 8(a)(x): Supply and erection of a regulating equipment (3 pulley type) with counter weight assembly for conventional/ composite OHE, Itis same as item No. 8(a)(v) but excluding stainless steel wire rope required for the regulating equipment. For shorter tension lengths OHE (like emergency x-overs) GI Sleeve of 20mm dia to be inserted in the hexagonal tie-rod of ATD of cross-over OHE in accordance with RDSO’s SMI No.TI/MI/0035(Rev-0). ITEM No. 8(a)(xi): Supply and erection of a regulating equipment (3 pulley type) wit counter weight assembly for tramway type ohe (regulated) Same as item No.8 (a)(vi) but excluding stainless steel wire rope for the regulating equipment. ITEM No. 8(a)(xii): Marking of ‘Y’ measurement at BWA locations The price shall cover marking/painting of temperature and *Y’ measurement on OHE masts at [ATD] BWA locations including cost of paint. ITEM No. 8(b)(i): Supply without insulator and erection of materials for termination of single conductor of overhead equipment or a terminating wire ‘The price shall cover supply of all material necessary for the termination of single conductor of overhead equipment or terminating wire on a traction mast or structure, including appropriate mast anchor fittings, clevis assembly, adjuster, anchor double straps, ending clamp for the catenary or contact wire or terminating wire and fittings but excluding 9 ton insulator assembly and terminating wire, if any. The price shall cover erection of all materials including the 9 ton insulator assembly and terminating wire, if any. NOTE: In case of “V” type anchorage is adopted for terminating a single conductor such an arrangement would be counted as two off under item 8(b) (i, for the purpose of payments, ITEM No. 8(b)(ii double conductors, ‘The price shall cover supply of all materials necessary for the yoked termination of two overhead equipment conductors on a traction mast or structure, including appropriate mast anchor fitting, clevis assembly, three adjusters, ending clamps for eatenary and contact wires, anchor double strap assembly, equalizing/compensating plate and fittings and but excluding 9 tonne insulator assembly and terminating wire. The price shall cover erection of all materials including the 9 tonne insulator assembly and terminating wire. Supply without insulator and erection of materials for termination of ITEM No. 8(b) Supply without insulator and erection of materials for termination of all (Single SPIDER) The price shall cover supply of all materials required for the termination of an all aluminium 25 kV feeder/teturn conductor (SPIDER), including appropriate mast anchor fittings adjuster, strain clamp end fitting and 3 kV cut-in-insulator but excluding the cost of 9 tonne insulator assembly (RI No.6020). The price shall cover erection of all materials including the 9 tonne insulator assembly and 3 KV cut-in-insulator. ITEM No. 8(b) (iv) DELETED- ITEM No. 8(b) (v): Supply without insulator and erection of materials for termination of an earth wire The price shall cover supply and erection of all materials required for the termination of an earth wire including appropriate mast anchor fittings, adjuster, terminal clamp and fittings. ITEM No. 8(b) (vi): Supply without insulator and erection of materials for termination of tramway ye OHE (Regulated) The price shall cover supply and erection of all materials required for the termination of a single contact wire (regulated) similar to 8(b)(i)/ (ii) and will exclude the parts covered under item 8(a)(iii)/ (vi). Notes to item 8 : 1) Small parts steel work wherever required, will paid for under item 3(b) or 3(b) and 3(¢) as applicable and shall not be included in this item. 2) The prices under item 8(b)(iii) shall not include the cost of jumper connection (i) between feeders or return conductors and (ii) or feeders or return conductors to a bus-bar, overhead equipment or isolator switch which will be paid for under item 15 3) The prices under items &(b)(i) to 8(b){ ii) shall also include the cost of double eye distance rod (Id no.5183), if provided for any type of terminations. ITEM No. 8(b)(vii): Supply without insulator and erection of materials for termination of double conductors for composite OHE he price shall cover supply of all materials necessary for, the yoked termination of two overhead ‘equipment conductors on a traction mast or structure including appropriate mast anchor fittings clavis assembly three adjuster, ending clamps for aluminium Alloy catenary and copper contact wires, anchor double strap assembly, unequal tension compensatory plate and fittings but excluding the 9 ton insulator assembly and terminating wire, if any. The price shall cover erection of all materials including the 9 ton insulator assembly and terminating wire, if any. ITEM No.8 (b)(viii): Supply without insulator and erection of materials for termination of an aluminium conductor of the composite overhead equipment The price shall cover supply of all materials necessary for the termination of single aluminium conductor of composite OHE or terminating wire on a traction mast or structure, including appropriate mast anchor fittings, clavis assembly, adjuster, anchor double straps, ending clamps for the aluminium catenary or terminating wire and fittings but excluding 9 ton insulator assembly and termination wire, if any. The price shall cover erection of all materials including the 9 ton insulator assembly and termination wire, if any. ITEM No: 8(b)(ix): Supply (without Insulators) and erection of materials for termination of Copper Cross Feeder with Gantries The Price shall cover the supply of all materials required for termination of copper feeder wire (37/2.25mm HDBC) including appropriate mast anchor fitting (3231), 18mm Single clevis (5040), 9-Tone adjuster (5020), Feeder ending clamp (1130), double clevis (3010) and other components as necessary but exeluding 9-Ton insulator assembly. The price shall also cover the erection of all materials including 9-ton insulator and termination of cross feeder at either ends. Fittings/Components required for termination of one cross feeder at both ends constitute one Notes to item (1) Small parts steel work complete with bolts and nuts wherever required, will be paid under item 3(a) or 3(b) and 3(c) as applicable and shall not be including in this item. (2) The prices under item 8(b)(iii) shall not include the cost of jumper connection (i) between feeders or return conductors and (ii) or feeders or return conductors to a busbar, overhead equipment or isolator switch which will be paid for under item 15. (3) The prices under items 8(b)(i) to 8(b)(viii) shall also include the cost of double eye distance rod (ID no. 5183), if provided for any type of terminations. (4) Supply and erection of materials for termination of catenary wire on either side of the portals at anticreep locations, will also be paid for under this item. ITEM No. 9(a): Supply without insulator and erection of anti creep with Galvanised steel ire for conventional The price shall cover supply of all materials for anti-creep including adjusters, galvanised steel wire, mast anchor fittings at its terminations on either side on structures, ending clamps and fittings but excluding the cost of 9 ton insulator assembly (RI No.6020) and small parts steel work, if any. The price shall cover erection of all materials including 9 ton insulator assembly but excluding small parts steel work, if any. Riy.1D No. Description of components Qty. per unit - Galvanised steel wire (19/2.50 mm) As required 6020 9 ton insulator assembl 2 off (schedule B) 1360 Steel wire ending clamp 2off 5020-1/5020-2 | 9 ton adjuster off 3030 ‘Anchor double strap assembly ‘As required 3010/5040 _ | Clevis assembly 2 off Mast anchor fitting with bolts, nuts etc., 2 sets Double suspension clamp Toff Suspension clamp Less () 1 off Double eye distance rod ‘As required 1. The price shall not include the cost of any additional cut-in or suspension insulator which will be paid for under item 11 (a) (1) or 11(a) (ii) as applicable. 2. In case the anti-creep extends beyond one span on either side of anti creep centre, payment for the supply and erection of extra length shall be paid additionally at the rate of 20% of the rate for 9(a) for each extra span. ITEM No. 9(b): Supply without insulator and erection of anti-creep with galvanised steel wire suitable for tramway type overhead equipment (Regulated) ‘The price shall cover supply and erection of all materials for anti-creep for the tramway type equipment (Regulated) similar to the fittings catered for an item 9(a). Rly.ID No. Description of components ‘Qty. per unit = Galvanised steel wire (19/2.50 mm) As required 6020 9 ton insulator assembly 2off 1360 Steel wire ending clamp. 2 off 5020-1/5020-2 | 9 ton adjuster Ino. 5030 ‘Anchor double strap assembly ‘As required 3010/5040 _ | Clevis assembly 3231 ‘Mast anchor fitting with bolts, nuts ete.. 3140 Large catenary direct clamp 5183 Double eye distance rod ‘As required ITEM No. 9(c): Supply without insulator and erection of anti-ereep for composite OHE wit galvanised steel wire Same as item 9(a) with following changes: Id No. 1171-1, MCI double suspension clamp with MCI lock plate stainless *U” bolt and nuts as per Drg.No.ETVOHE/SK/469 (Mod-A) to be used in place of Id.No. 1170. There shall be suitable rebate for non-provision of MCI suspension clamp (Drg.No.ETV]OHE/SK/469 (Mod-A). ITEM No. 9(d): Supply without insulator and erection of anti-creep with cadmium copper -atenary wire in polluted area ‘The price shall cover the supply of all materials for anti-creep including, adjusters, mast anchor fittings as its terminations on either side of structure, ending clamps and fittings but excluding cadmium copper catenary wire and 9 ton insulator assembly for polluted zone and small parts steel work, if any. The price shall cover erection of all materials including cadmium copper catenary wire, 9 ton insulators assembly and small parts steel work, if any. Rly.ID No. Description of components ‘Qty. per unit - ‘Cadmium copper catenary wire (65 sq.mm) ‘As required 6020-1___| 9 ton insulator assembly 2 off (schedule B) 1120 Catenary ending clamp oft 5020-1/5020-2 | 9 ton adjuster 5030 ‘Anchor double strap assembly 3010/5040 _ | Clevis assembly 3231 Mast anchor fitting with bolts, nuts ete., 2140 Large catenary direct clamp 1 off 1160 Suspension clamp Less () Toff 5183 Double eye distance rod ‘As required NoT Notes 1 and 2 given under item No. 9 (a) shall also be applicable for items 9 (b) to 9(e). ITEM No. 9(¢): Supply without insulator and erection of anti-creep with cadmium copper catenary wire suitable for tramway type ohe (regulated) in polluted area Same as Item 9(d) with the following changes: Id No. 2140, large catenary clamp to be used in place of Id. No. 1170. ITEM No.10(a), (b), & (c): Extra on item 6(a), 6(b), 6(¢) & 6(d) for supply and erection of additional fittings required at a turnout, diamond crossing or over-lap The price shall cover on flat rate basis supply of additional components and fittings required at turnouts, crossings or over-laps (insulated or un-insulated) including overlaps, knuckle or crossing equipment at a turnout, or a diamond crossing and parallel clamps/bimetallic parallel clamp for jumper connections between two sets of ovethead equipment conductor at a turnout, diamond ‘crossings, overlaps or neutral section, but excluding jumper wire. The price shall cover erection of all materials including jumper wire, and all adjustments required at turnouts, crossings, overlaps and neutral sections. The price shall also cover erection of potential equalizer jumpers at insulated overlaps and neutral sections. The price shall not include extra bracket assemblies, overhead equipments, termination of overhead equipment and cut-in-insulators in the case of insulated overlaps and neutral section which will be paid for under items 4, 6, 8, and 11 respectively. NOTE: A cross-over shall be paid for as 2 off of Item 10, special configuration of OHE commonly known as half overlap shall be paid for as 1 off under this item. This shall apply in case of half overlap used in changing over from regulated to unregulated equipment or unregulated to regulated equipment, ITEM No. 11(a)(i): Supply without insulator and erection of a solid core suspension cut-in- insulaton The price is applicable to the provision of an additional 9 tonne cut-in-insulator on a flat rate basis such as in a head span, cross span or in span wire or an overhead equipment conductor at an insulated overlap, anti-creep not provided for in other items. The price shall cover supply of all components required for the cut-in-insulators assembly, including appropriate terminal fittings for the conductor but excluding 9 tonne insulator. This price shall cover erection of all components, including the 9 tonne insulator. This price shall also be applicable as an adjustment price for non= provision of insulators under items 8(b)(i) to 8(b) (viii). ITEM No. 11(a) (ii insulator The price is applicable to the provision of a 9 tonne suspension insulator assembly for suspension of an all aluminium 25 KV feeder (single or double SPIDER), 130 sq.mm or 65sq.mm overhead equipment conductor or 19/2.79 mm all aluminium catenary or any other similar type of suspension. The price shall cover supply of all components, required for the suspension assembly including the appropriate suspension clamp but excluding 9 tonne insulator and small parts steel work if any. The price shall cover erection of all components including the 9 tonne insulator assembly but excluding small parts steel work, if any. Supply without insulator and erection of 25KV solid core suspension The price shall include the cost of provision of a flat armour tape to be used in connection with suspension of ‘SPIDER’ conductor. ITEM No. 11(b): Supply without insulator and erection of a 25 KV post insulator. The price is applicable to the provision of a 25KV post insulator to support copper or aluminium jumper/busbars. The price shall cover supply of all components and fittings/angle iron (outrigger) to support the jumpers but excluding supply of post insulators and small parts steel works if any. The price shall cover erection of all components required for the assembly including the post insulator, but excluding small parts steel work if any. ITEM No. 11(c): Supply and erection of a 3 kV disc insulator The price is applicable to the provision of a 3 kV insulator for suspension of an all aluminium return conductor or any other similar type of suspension. The price is also applicable to a3 kV cut-in insulator for earth wire. The price shall cover supply and erection of all components required for the assembly, including 3 KV Disc Insulator and appropriate suspension clamp, ending clamp for cut-in-insulator on earth wire, but excluding small parts steel work if any. The price shall include the cost of provision of a flat armour tape to be used in connection with the suspension of SPIDER/RACCOON conductor. ‘The supply includes dise insulator cost. ITEM No. 11(4): Su y and erection of a 11 KV post insulator, The price shall cover, on a flat rate basis, supply and erection of an 11 KV post insulator with necessary fittings to support return conductor, aluminium or copper bus bars or return conductor jumper connections excluding small parts steel work if any. The supply includes post insulator cost. ITEM No. 11(e):Supply and erection of Erection of a 25 KV Support insulator. The price shall cover supply and erection of a 25 KV Support insulator complete with fixing bolts, nuts, and studs and includes supply of insulator. ITEM No. 12(2): Supply without insulators and erection of a 25KV section insulator assembh The price shall cover supply of all components required for a standard section insulator assembly (serving both the overhead equipment conductors) including special droppers for supporting the ‘equipment and all terminal fitings for conductors but exeluding supply cost of section insulator, 9 tonne insulator on the eatenary and dropper wires. The price shall cover erection and adjustment of all components such as section insulator assembly, Section Insulator, 9 tonne insulator on the catenary and droppers. Riy.1D No. Description of components ‘Qty. per unit 1120 or 1122 | Catenary ending clamp 2off & 1123 1192 Catenary dropper clip assembly As required 6170 Parallel clamp for double contact wire Toff, 6180 Section insulator dropper assembly 3 sets 6110 Section insulator assembly 1 6020 9 tonne insulator assembl 1 ITEM No. 12(b) Supply without insulator and erection of a double wire section insulator assembly ‘The price shall cover supply of all components required for a double wire section insulator assembly (to serve both wires of two overhead equipments and special droppers for supporting this equipment) at any location, including terminal fittings for the conductors and the double wire section insulator assembly but excluding section insulators 9 ton insulator and dropper wires. The price shall include erection and adjustment of the entire assembly including double wire section insulator assembly, droppers and the 9 ton insulators. ITEM No. 12(c) Supply without insulator and erection of a 2SKV section insulator assembly suitable for tramway type OHE (Regulated) The price shall cover supply ofall components required for a standard section insulator assembly including special arrangements for supporting the equipment and terminal fittings but exeluding supply of section insulator as required. The price shall cover erection and adjustment of all ‘components such as sectioning insulator assembly NOTE: 1. The same price will apply if the section insulator is provided in the tramway type equipment (contact wire only), 2. The supply and erection of a bracket assembly shall be paid under item 4(a) (ii) No adjustment of price due to non-provision of steady arm, in this case, shall be made, ITEM No. 12(d): Erection of Ceramic/Glass fiber or PTFE tvpe short neutral section assembh ‘The price shall cover erection and adjustment of Glass Fiber or PTFE type short neutral sections, which would be supplied by the Purchaser. The prices cover fittings for contact and catenary wire as necessary. ITEM No. 13(a): Supply without Insulators and ereetion of 25 KV S.P Isolators without earth contact assembly. The prices shall cover supply and erection of isolator switches of approved make, complete with arcing horns, operating rods, operating rod guides, mounting base and integral locks but exeluding supply of 25 kV solid core insulator and operating rod insulators. ‘The price shall also cover supply and erection of a number plate of approved design for each isolator complete with bolts and nuts ete. The price shall not include supply and erection of small parts steel work for support of isolators and for support of operating rods on gantries/masts, and insulator to support jumper and jumper connectors. ITEM No. 13(b): Supply without Insulators and erection of 25 KV_S.P Isolators gang operated without earth contact assembly, The prices shall cover supply and erection of isolator switches (gang operated) of approved make, complete with arcing horns, operating rods, operating rod guides, mounting base and integral locks but excluding supply of 25 kV post insulators and operating rod insulators, The price shall also cover supply and erection of a number plate of approved design for each isolator complete with bolts and nuts etc. The price shall not include supply and erection of small parts steel work for support of isolators and for support of operating rods on gantries/masts, and insulator to support jumper and jumper connectors. ITEM No. 13(c): Supply without Insulators and erection of 25 KV double pole isolator (12004) The price shall cover supply and erection of a double pole isolator complete with mounting base, operating rod, operating rod guides and operating rod insulator required for the operation of the isolator but excluding the cost of operating rod insulators and 25 kV post insulators. ‘The price shall also cover supply and erection of ALCU strips, a padlock and a number plate of approved design for cach isolator. The price shall not include supply and erection of small parts steel work for support of isolators and for support of operating rods on gantries masts. ITEM No. 13(d): Extra for supply and erection of an earth contact assembly in an isolator, The price shall be payable as extra for erection of an earth contact assembly in any isolator. The price shall cover the cost of supply and erection of 3x25 mm copper connections between the earth contact assembly and the structures. ITEM No. 13(e): Extra on item 13(a), (b) or (c) for an inter-locking device. The price shall cover supply and erection of an inter-locking mechanism on an isolator to permit working of two or more isolators or an isolator and an interrupter in a desired sequence. This item shall be applicable individually for each isolator or interrupter. NOTE: Prices under item 13 do not include the cost of supply and erection of (i) any post insulator to support jumpers/bus bars which shall be paid for under item 11(b), (i) flexible jumper connection which will be paid for under item 15 and (iii) bus bar/bus-rod terminals which will be paid for under item 26(b) or (c). The price does not include also the cost of supply and erection of an aluminium/copper bus bar or a copper bus rod the cost of which will be paid for under item 26(a)(i) or 26(a) (ii), as applicable, ITEM No.13(g)(i): Erection, Testing and commissioning of 25 KV single pole isolator 1600 A The price shall cover erection of 25 KV single pole, 1600-A, isolator switches of approved make including insulators, complete with arcing horns, operating rods, operating rod guides, mounting base. The price shall also cover supply and erection of a number plate of approved design for each isolator. The price shall cover supply of padlock for the isolator. The price shall not include supply and erection of small parts steel work complete with bolts and nuts etc. for support of isolators and for support of operating rods on gantries/masts, and insulator to support jumper and jumper connectors. The price does not include supply of isolator and insulators. ITEM No: 13(e)(ii): Extra for Erection of Interlocking Device for item No. 13(g)(i) The price shall cover erection of an interlocking mechanism on an Isolator to permit working of ‘two or more isolators or an isolator and an interrupter in a desired sequence. This item shall be applicable individually for each isolator or interrupter. ITEM ction of 25 KV Double po! . complete with arcing horns, operating rods, operating rod guides, mounting base. The price shall also cover supply and erection of a number plate of approved design for each isolator. The price shall cover supply of padlock for the isolator .The price shall not include supply and erection of small parts steel work complete with bolts and nuts etc. for support of isolators and for support of ‘operating rods on gantries/masts, and insulator to support jumper and jumper connectors. The price does not include supply of isolator and insulators. ITEM No: 13(h)(ii) Extra for supply and Erection of Interlocking Device for item No.13(h)(i) The price shall cover supply and erection of an interlocking mechanism on an Tsolator to permit working of two or more isolators or an isolator and an interrupter in a desired sequence. This item shall be applicable individually for each isolator or interrupter. ly and erection of all types of copper jumper: ‘The price shall cover, on a flat rate basis, the supply of all components and fittings required for providing a flexible copper jumper connection, including parallel clamps, bi-metallic and aluminium copper ALCU strips, wherever required, and terminal or tee clamps at either end, and excluding cost of jumper wire. The price shall also cover the erection of the complete jumper assembly including jumper wire ‘The price shall not, however, be applicable for jumper connections already included under item 6(a) and 10, but shall be applicable for any jumper connection in any combination between feeders, lightening arrestors for overhead equipment’s, isolators for overhead equipment and outgoing bus bars for switching stations and boosters stations etc . Continuity jumper at Boom anchor anti-creep will be payable under this item. Anti-theft jumper as per drawing No. ETI/OHE/G/05107 for connecting out-of-run OHE with the in running OHE at insulated/un-insulated over-lap locations and also anti creep locations at polluted zone wherever considered necessary will be payable under this item. ITEM No. 15 (b): Supply and ere The price shall cover on a flat rate basis the supply and erection of an aluminium jumper of size 19/7/1 4mm bare 3/4H generally confirming to IS:8130 complete with all components and fittings required for providing jumper connection, including parallel clamps, bimetallic ALCU strips wherever required, and terminal or tee clamps at either end. The price shall be applicable for any aluminium jumper/connections in any combination between feeders, return conductors, overhead equipment, and isolators and outgoing bus bars or switching stations and booster stations, ITEM No.15(c): Supply and Erection of Insulated Catenary cable in the span under Over- ine Structure The price shall cover the price of supply and erection of catenary splice (1090) for each location and Dropper clip in case span of Over-Line Structure is more than eight meter. The prices shall cover the erection of insulated catenary including adjustment of Dropper wire. The work shall be executed in accordance with drawing No.ETIMOHE/SK/S70. The insulated catenary wire will be under Schedule-B: Non SOR item. The price shall also cover the cutting of existing Catenary wire ITEM No. 15(d): Supply of material excluding copper wire and erection of a large copper jumper 160 Sq.mm between Aluminium bus and cross feeder. This jumper shall be provided between 36mm Aluminium bus and the copper cross feeder at SP/SSP/EP/BT locations. The price shall cover the supply of all components and fittings required for providing a flexible copper jumper (160 Sq.mm) and connection between 36mm Aluminium bus and cross feeder including Terminal connector 19mm multiple hole bolted type (1009), paralle! clamps (1053-3), Al-Cu bimetallic strips, fasteners but excluding jumper wire which will be paid under Schedule-B : Non SOR item The price shall also cover the erection of the complete jumper assembly including jumper wire. ITEM No. 15(e): Supply of material excluding copper wire and erection of a large copper jumper 160 Sq.mm between cross feeder and OHE. This jumper shall be provided between copper cross feeders and OHE. The price shall cover supply of all components and fittings required for providing a flexible copper jumper (160 Sq.mm) between copper cross feeder and OHE, including Parallel clamps (1030-3 & 1050-3) complete with fasteners ete as required but excluding jumper wire which will be paid under Schedule-B: Non SOR item. The price shall also cover the erection of the complete jumper assembly including jumper wire, ITEM No. 16(a): Supply and erection of a structure bond. The price shall cover supply of all materials including mild steel flat required to provide a structure bond connecting a traction mast or structures to the nearest non-track circuited rail, or earth electrode, including all fastenings at both ends. The price shall include shaping and drilling of the bond and erection of all materials including the bond. The price shall also include provision of heat shrinkable PVC tube for structure bond under track circuited rail. This would also cover connection or earthing terminals of equipment’s like L.T. Transformers with structure and then to rails as per relevant drawings. The price shall cover provision of burried rail to running rail as per RDSO drawing No. ETVOHE/G/05306 and shall include supply, fabrication and erection of all connections (including drilling at both ends) and refilling of burried rail pit. The price shall cover erection of U clamp or saddle on bonds for platform locations. The supply of saddle/U clamp (galvanized) is payable under item 3(c) of Schedule-B. ITEM No. 16(b): Supply and ercetion of longitudinal bond: ‘The price shall cover the supply of all materials including mild steel flats, fasteners etc. required to provide longitudinal bond connecting two rails at the rail joint at the locations to be specified by the Purchaser. The price shall include shaping and drilling of the bond and erection of all materials including the bonds ITEM No. 16(c): Supply and erection of transverse and special bond: The price shall cover supply of all materials including mild steel flats, fasteners ete. require provide transverse bond connecting rails of the same/adjacent tracks at the locations to be specified by the Purchaser. The price shall also cover the supply of all materials including mild steel flat to provide special bonds at level crossing, foot over'road over bridge /protective screen ete. for which the location will be specified by the Purchaser, The price shall include shaping and drilling of the bond and erection of all materials including the bond, The earthing for the PSC mast will be carried out as per RDSO drg no. ETVOHE/SK/437 sh.1 (Rev.D). The price admissible for earthing of PSC mast will be paid as special bond under this item. ‘The price shall include supply and erection of materials including M.S. Flat, fasteners ete. required for earthing of super mast to stay arm fitting to earthing and bracket arm fitting to earthing wherever applicable. ITEM No.16 (aa): Drilling of holes on. The price coves removal of existing bond from rail, drilling of holes on rail and connecting the bond to the rail . Bond means all types of bonds as far as this item is considered. The price does not include cost of bond but includes bolts, nuts and washers. ITEM No. 17(a) Supply and erection of single earth electrode The price shall cover supply and erection of an earthing station with a single pipe embedded into the ground by driving or otherwise complete with protective concrete box and lugs suitable for directly connecting two mild steel flats of minimum size 50 mm x 6 mm, ITEM No. 17(b): Extra for special embedment of earth electrode The price shall be payable as extra on item 17 (a) where an earth electrode is embedded by driving or otherwise in an earth pit filled with charcoal and salt. The price shall cover supply and erection of all additional materials required for embedding the earth pipe. ITEM No. 17(c): Supply and erection of earth bus The price shall cover the supply of all materials including 50 mm x 6 mm mild steel flats for providing earth bus. The price shall also cover erection of earth bus either buried at a depth of 300mm below ground level painted with 2 coats of red oxide zine chromate primer and 2 finishing coats of bitumen as per the particulars specified in para 2.1.49 or fixed on wooden gutties on walls, It shall include connecting the earth bus to earth electrodes and to various floor-or-wall-mounted ‘equipments or structures to be earthed and also connections to non-track-circuited rails, wherever required it shall also cover the cost of making recesses in conerete foundation blocks or floor or cubicles and covering them up. The connection of earth strips to each other shall be made either by riveting or by welding. The connection of earth strips to various equipment, structures or fencing post shall be made with G.I. bolts and nuts and spring washer/locknuts. ITEM No. 17(4): Supply and erection of copper strips for equipment earthing The price shall cover supply and erection of 25mmx3mm copper strips to connect the earth terminals of equipments like potential transformers, lightening arrestors, L.T. supply transformers and booster transformer to the main masts of the gantries on which they are mounted. The price shall cover all fastenings required for fixing the copper strips along any structure member of the gantry. ITEM No. 17(e): Supply and erection of 8 SWG G.I WIRE for earthing The price shall cover supply and erection of 8 SWG G.l wire per meter, used for earthing of remote control cubicles, fencing panels, control panels DB’s ete. ITEM No. 17(f): Supply and erection of Earth electrode at TS! The Price shall cover supply and erection of an earthing station with a single pipe embedded into the ground by driving or otherwise complete with protective concrete box and lugs suitable for directly connecting two mild steel flats of minimum size of S0mm X 6mm. ITEM No. 17(g): Supply and erection of Earth leads 75mmx8mm in the ground at TSS The price shall cover supply and installation per meter length 75 X 8 mm mild steel flat, buried at a depth of 60 cm below ground level. The price shall also cover connections of the steel flats to the arth electrodes to constitute the main earth ring and to the earthed terminals of the132/25 KV Transformers ete. as required. ITEM No. 17(h): Supply and erection of Earth leads 50mmx6mm mild steel in ground at TSS The price shall cover supply and installation per meter length of 50 X 6mm mild stee! flat buried at depth of 60 cm below ground level. The price shall also cove connections of the steel flats to the main earth ring and to the steel structures and metallic frame work/terminals of various equipments, as required. Note: for item No: 17 (g) & 17 (h): The price for item 17 (g) & 17 (h) shall cover supply and installation of a buried rail of approx .13 m length, ITEM No. 17(i): Supply and erection of Earth leads 75mmx8mm mild steel exposed at TSS ‘The price shall cover supply and installation per meter length of 75 X 8 mm mild steel flat, painted all around with two coats of painting to colour grass green shade-218 of IS:5 passing through cable trench or exposed above ground level. The price shall also cover the connections of the steel flats to the earth electrodes, to constitute the main earth ring and to the earthed terminals of the various equipments as required. ITEM No. 17(j): Supply and erection of Earth leads 50mmx6mm mild steel exposed at TSS The price shall cover supply and installations per meter length of 50 X 5 mm mild stee! flat painted all around with two coats of painting to colour grass green shade ~ 218 of IS:5 passing through cable trench or exposed above ground level. The price shall also cover the connections of the steel flats to the main earth ring and to the steel structures and metallic frame work! terminals of various ‘outdoor equipments as required. ITEM No.17 (Jo: 32 mm MS rod for earth mat ‘The price shall cover supply and installation per meter length of bare mild steel rod of dia 32 mm, to be buried at a depth of 60cm below the ground level to form the earthing grid and connected to earth electrodes. The price shall also cover jointing of the M.S, rods to form earthing grid and connection to MSS. flats for system earthing. ITEM No.17 (1): Supply and erection of earth screen wires The price shall cover supply and stringing per meter length of 19/2.5mm [70Kg/mm] galvanized steel stranded wire. It shall include the supply and erection of suitable terminations using strain clamps adjuster [on one side only] ete. It shall also include connecting by means of suitable terminal spades the end of the earth screen wire to the main members of the columns of portals gantries across which these wires are strung or to S0X6mm MS flat earth leads. For purpose of payment the clear span between the structures on which earth wire is run shall be adopted. The clear span will be rounded off to the nearest meter [0.5m and below being ignored]. ITEM No.17 (m): Supply and erection of earth screen wires of size 7/9 SWG Same as Item 17[I] above except that the earth screen wire of size 7/9 SWG to be used in place of earth screen wire of size 19/2.5mm Note: For purposes of payment for Items 17 (b) to (m) fraction of a meter in the total length of earth lead of each type used at sub-stations shall be rounded off to the nearest meter (0.5m and below being ignored). The prices shall also include dismantling of the existing earth leads. ITEM No.17 (n): Erection of Maintenance free earth kit ‘The price shall cover installation of set of maintenance free earth kit consisting of Copper plated carth electrodes (4 Nos of 6 feet long), earth enhancing compound and coupler. The price shall include digging the earth to the required depth and filling up of earth enhancing compound. The price includes exothermic welding and fixing of copper tape. The price includes running of bronze cable from kit to the structure requiring earthing. The price includes joining electrodes using coupler. ‘acuum e Interrupters The price shall cover erection of SF-6 gas filled/ Vacuum type Interrupters complete with supporting frame-work, terminal connectors, accessories, operating mechanism and all fittings ete for their efficient and trouble-free operation... The price for erection shall include alignment and grouting of the Interrupter on its foundation block and mounting of accessories, if any, in their respective positions. The Contractor shall make his own arrangements for filling of SF-6 gas, including supply of gas of approved make. The price shall also cover supply and erection of enamelled number plates. All Necessary tools, equipments instruments, including power supply required for carrying out necessary checks, tests and commissioning shall be arranged by the Contractor. The price also covers grouting, modifications, if any to the existing supporting steel structure/frame, positioning the mechanism box on foundation block and also the other accessories in their respective positions. In case of modification/alteration required for the existing foundation/structure, the contractor shall submit the designs/drawings for the modification/alteration with supporting explanatory notes, calculation etc. to the Purchaser/railways for approval. Concrete for modification/alteration to the foundation shall paid under item No, 2. The price shall also cover erection of enamelled number plate for the Interrupter. All the tools & plant, equipment/instruments required for testing and commissioning of the interrupter shall be arranged by the Contractor. ITEM No. 18(b) Erection of single pole 25 KV SF6 gas/ Vacuum type Circuit Breaker The price shall cover erection of 25 KV SF6 gas type circuit breaker complete with supporting frame work and terminal connectors for their efficient and trouble-free operation. The price for erection shall include alignment and grouting of the Circuit breaker on its foundation block and mounting of accessories, if any, in their respective positions. The Contractor shall make his own arrangements for filling of SF-6 gas, including supply of gas of approved make. The price shall also cover supply and erection of enamelled number of plates and carrying out necessary checks, tests and commissioning shall be arranged by the Contractor. The price also covers grouting, modifications, if any to the existing supporting steel structure/frame, positioning the mechanism box on foundation block and also the other accessories in their respective positions. In case of modification/alteration required for the existing foundation/structure, the contractor shall submit the designs/drawings for the modification/alteration with supporting explanatory notes, calculation ete. to the Purchaser/railways for approval. Conerete for modification/alteration to the foundation shall paid under item No, 2. All necessary tools, equipments, instruments including power supply required for carrying out necessary checks, tests and commissioning shall be arranged by the contractor. .M_ 18( d): Extra for erection of interlocking mechanism for Item 18(a), 18(b) and 18 ‘The price shall cover supply and erection of an interlocking mechanism for the Circuit Breakers to permit working of two or more Circuit Breaker or and an Interrupter in a desired sequence. This item shall be applicable individually for each circuit breaker or Interrupter. ITEM No. 19(a)(i):Erection of 25 KV Potential Transformers.(type-I)( Indicating) The price shall cover erection of a 25 ky potential transformer type-I complete with all fittings and accessories as per relevant specifications, including terminal connectors and fixing bolts. The price for erection shall include proper alignment of the transformer in position. The price shall also cover the erection of an enamelled number plate and fixing bolts. The price shall not include the cost of any small parts steel work and PT. ITEM No. 19(a)(ii) Erection of 25 KV Potential Transformers.(type-I1) (Protection) The price shall cover supply and erection of a 25 kV potential transformer type-II complete with all fittings and accessories as per relevant specifications, including terminal connectors and fixing bolts. The price for erection shall include proper alignment of the transformer in position. The price shall also cover the erection of an enamelled number plate and fixing bolts. The price shall not include the cost of any small parts steel work and PT. ITEM No.20(a): Erection of 42 KV Lightening arrestors (10 KA rating) ‘The price shall cover erection of 42 kv metal oxide gapless lightening arrestors complete with all fittings and accessories as per relevant specifications including terminal connectors and fasteners etc. The cost of erection shall include proper alignment of the lightening arrestor in position and supply and erection of an enamelled number stud. The price shall not cover supply and erection of cadmium copper jumper (65) which will be paid under ITEM No 15.The price shall not include the cost of any small parts steel work and LA. ITEM No. 20(c): Erection of 120 KV Lightning Arrestors ‘The price shall cover erection of metal oxide gapless 120 KV class (suitable for 132 KV TSS) lightening arrestor complete with all fittings and accessories. The cost of erection shall include proper alignment of the lightening arrestor in position and supply and erection of an enameled number stud. The price shall not include the cost of any small parts steel work and LA. ITEM No. 21: Supply and erection of terminal boards in control cubicles ‘The price shall cover supply and erection of a wall mounted terminal board with six numbers of ‘two-way terminal blocks for connecting the cables from the outdoor equipment of a switching station as per Railway Drawing given in list “A’ Annexure-L ITEM No. 22(a): Supply and erection of 110V D.C. fuse box ‘The price shall cover supply and erection of a 15A, 11 0V Iron clad or latest two way fuse box on the wall inside the remote control cubicles. The fuse box shall be complete with two fuse carries and bases. ITEM No. 22(b): Supply and erection of 230V_AC. fuse box ‘The price shall cover supply and erection of a ISA, 230V.AC. Iron clad or latest 4-way fuse box on the wall inside the remote control cubicle, for heater supply of Interrupters. The fuse box shall contain four fuse carriers and bases. ITEM No. 22(c): Supply and erection of 240 V. L.T. Distribution board in the control room for 10 KVA LT. supply transformer ‘The price shall cover supply and erection of a 240V AC distribution board in the Control Room. It shall include the grouting of the framework of the distribution board in position or mounting it on the wall and necessary connections. ITEM No. 22(d): Supply and erection of 110 V. DC Distribution board. The price shall cover supply and erection of a 110 V DC distribution board in the control room. The price shall include the grouting of the frame work of the distribution board In position or mounting it on the wall and necessary connections. ITEM No. 23{a): Erection of lead acid batteries (40 AH capacity) The price shall cover erection of 110V, 40AH lead acid battery complete with stand, accessories and a tool board. The price for erection shall include installation and connecting up of the battery, but exclude the cost of connecting cables, the supply and erection of which will be paid for under item 25. The price for erection shall include installation, connecting up, charging at site if required and commissioning of the battery. ITEM No. 23(h): Erection of lead acid batteriesfor 200 Ah, 110 Volt ‘The price shall cover erection of 110V, 200Ah lead acid battery complete with stand, accessories and a tool board. The price for erection shall include installation andconnecting up of the battery, but exclude the cost of connecting cables, the supply anderection of which will be paid for under item 25. The price for erection shall includeinstallation, connecting up, charging at site ifrequired and commissioning of the battery. ITEM No. 24 (a): Erection of battery chargers for 40 Ah batteries The price shall cover erection of battery charger for a 110V, 40Ah lead acid battery complete with connecting lead and plug for connection to 230 V AC. supply. The price for erection shall include mounting of the charger in position and connecting it up to the 230V AC. distribution board in the control cubicles. The price shall not include supply and erection of any cable for connecting the charger to the 110V battery which shall be paid for under item 25. ITEM No. 24(b): Erection of battery chargers for 110 V, 200 Ah battery: The price shall cover erection of battery charger for a 110V, 200Ah lead acid batterycomplete with connecting lead and plug for connection to 230 V A.C. supply. The pricefor erection shall include ‘mounting of the charger in position and connecting it up to the230V A.C. distribution board in the control cubicles. The price shall not include supplyand erection of any cable for connecting the charger to the I10V battery which shall bepaid for under item 25 ITEM No. 25: Supply and installation of cables for control and indication ITEM No. 25(a) Control and indication The price shall cover supply and installation per meter length of a PVC 1100V grade 2.5 sq.mm (copper conductor) 7 core cable from each circuit breaker and Interrupter to the Control and Relay Board. The price shall include supply and erection of terminal connectors at both ends, if required and conduits where necessary. ITEM No. 25(b): Heater supply he price shall cover supply and installation per meter length of 1100V Grade PVC insulated heavy duty 2 Core 4 sq.mm copper conductor heater supply cable from Interrupter to Interrupter or from the Interrupterto the 230V AC. fuse box mounted on wall inside the control cubicle and from this fuse box to L.T. distribution board provided by the Purchaser inside the control cubicle. The price shall include cost of supply and erection of terminal connectors at each end, if any required, and conduit, if any at the Interrupter end. ITEM No. 25(c): Catenary indication ‘The price shall cover supply and installation per meter length of PVC 1100V grade 2.5 sq.mm (copper conductor) 2 Core cable from each potential transformer to the control and Relay Board, and from 240V AC LT distribution board to control and relay board. The price shall include supply and erection of terminal connectors at both the ends if required and conduit to be embedded between the steel work based and the cable trench and shalll include all fastenings on masts and structural members to support them, ITEM No. 25(d): L.T. Power Supply The price shall cover supply and installation per meter length of an 1100V grade 25 sq.mm aluminium conductor 2 Core PVC insulated and armoured cable from each L.T. supply transformer to the L.T. AC. distribution boards and from there to 132/25kV Traction Transformer for extending L.T. supply to blower fans. The price shall cover supply and erection of suitable cable boxes, if required, and connectors at both ends. ITEM No. 25(e): L10V D.C. / 240 V ac Power Supply, The price shall cover supply and installation per meter length of PVC 1100V grade 4sq.mm (copper conductor) 2 Core cable from each current transformer to the control and relay board, from 110¥V DC distribution board to the control and Relay Board and from 240V AC. LT distribution board to Battery Chargers.. The price shall include terminal connectors, wherever requi OTE: The length of cables shall be the actual distance measured along the lengths of the cable between the starting and terminating points of each cables. 2. For purposes of payment fraction of a meter in the total length of cable of each type used at a switching station, shall be rounded off to the next higher meter. 3. Price under item 25 do not include cost of concrete cable trenches which will be paid for under item 2(¢). 4, The price shall also include releasing existing cables. All released cables and connectors shall be handed over to Section Engincers of respective PSI depots and have to be accounted for. 5. The price for erection of cables shall include cable boxes, metallic glands, identification labels, terminal connectors, copper lugs and leading inducts or pipes as required. 6. The price for erection shall include connecting up of the cable at either end. It shall also include clamping of the cable on steel supports, fixing in the trenches, on the structures, on the framework of the equipment or on the wall of the control room as required. s supply and laying of XLPE insulated PVC sheathed aluminium conductor armoured power cable of aluminium cable of size 2 core x 25 sq.mm as per ISS: 7098 heavy duty, 1100 V with IS markings for signal purpose as per latest RDSO directives. The cable shall be laid from LT. signaling AT to the station building AT control panel or part thereof. The cable should be of RDSO approved make. The price shall include testing, connecting/jointing and commissioning of cable and it will be paid/meter length. Suitable cable indicators are to be placed at regular interval in an approved manner. No intermediate joint is permitted, whatever be the length of cable used. ITEM No: 25(f) (ii): Supply and Laying of 2 core, 70 sq mm XLPE Aluminium Cable The price shall cover supply and laying of XLPE insulated PVC sheathed aluminium conductor armoured power cable of aluminium cable of size 2 core x 70 sq.mm as per ISS: 7098 heavy duty. 1100 V with IS markings for signal purpose as per latest RDSO directives. The cable shall be laid from L.T. signaling AT to the station building AT control panel or part thereof. The cable should be of RDSO approved make. The price shall include testing, connecting/jointing and commissioning of cable and it will be paid/meter length. Suitable cable indicators are to be pl at regular interval in an approved manner. No intermediate joint is permitted, whatever be the length of cable used. ITEM No:25(g)(i): Excavation of cable trench (in ordinary soil) of size 30cm wide and 90em deep and supply and laying of RCC/ hum pipes, sand ete & making original arrangements

You might also like