You are on page 1of 1

T-BEAM

Fully Prestessed Tee Beam to ACI 318


This worksheet is used to estimated a workable section of a simple span prestressed tee beam.

Mmin = 284 kN/m2 Mmax = 3584 kN/m2


f'c = 33 N/mm2 f'ci = 25 N/mm2
h= 0.9

N.A
+y h1 1 3 h3
Section dimensions 2 h2
b1 = 300 mm h1 = 230 mm
b2 = 1700 mm h2 = 1200 mm
b3 = 300 mm h3 = 230 mm b1 b2 b3

Part Ai yi Aiyi Aiyi^2 Ioo Ixx


mm2 mm mm3 mm4 mm4 mm4
1 69000 1085 74865000 8.1229E+10 3.04E+08 8.15E+10
2 2040000 600 1.22E+09 7.344E+11 2.45E+11 9.79E+11
3 69000 1085 74865000 8.1229E+10 3.04E+08 8.15E+10
2109000 1.3E+09 1.06E+12

yb = 616 mm yt = 584 mm
I= 2.608E+11 mm4
Zt = 4.46E+08 mm3 Zb = 4.23E+08 mm3
kt = -201 mm kb = 212 mm

BS8110 : Section 4 : Class 3 : Allowable stresses


ACI 318
Allowable compressive stress at transfer, s ci = 15.00 N/mm2 0.6f'ci
Allowable tensile stress at transfer, s ti = -1.25 N/mm2 0.25sqrt(f'ci)
Allowable compressive stress at service, s cs = 14.85 N/mm2 0.45f'c
Allowable tensile stress at service, s ts = -2.87 N/mm2 -0.5SQRTf'c
DM= 3300 kNm
Check required section modulus, Zt >= 2.08E+08 mm3 OK
Check required section modulus, Zb >= 2.03E+08 mm3 OK

Cover to prestressing steel = 80 mm


Seathing duct diameter = 56 mm
c.g.s eccentricity wrt duct = 8 mm 0.15 x duct dia.
Maximum practical eccentricity, eo(mp) = 508 mm
Adotped eo = 480 mm
Minimum prestressing force, Fe = 3477.80 kN Eqn III -11354 kN
Eqn IV 3478 kN

Adopted prestressing force, Fe = 3400 kN


Check ectreme fibre stress
Top fibre stress at transfer (tensile) I -1.63 N/mm2 NG!
Bottom stress at transfer (compressive) II 5.40 N/mm2 OK
Top fibre stress at service (compressive) III 5.98 N/mm2 OK
Bottom fibre stress at service (tensile) IV -3.00 N/mm2 NG!

Page 1