Vibration- & Sound insulation

Floor Wall Ceiling

Version 5.01

Phone: +45 36 77 88 00
Web::
Tel: www.iac-nordic.dk
+45 36 78 54 98
E-mail:: nordic@iac-nordic.dk 1
Web: http://www.iac-acoustics.com/dk/
Email: nordic@iac-nordic.dk
www.iac-nordic.dk

TABLE OF CONTENTS

4. VIKAFOAM

F L OOR
Reduction of noise with floating floors in
buildings and production halls.

6. VIKACELL
Ideal for floating floors when vibration
reduction requirements are high.

8. JACK UP
VIKAS Jack Up System FZH is used
in sound studios, office environments
and in production halls.

9. STEEL FLOOR
Low-profile steel floor on vibration
dampers for best sound isolation
WALL

10. VB WALL MOUNT


Used for fastening sound-insulating
staggered walls.

12. VBS WALL MOUNT


Used for fastening sound-insulating
staggered walls.

13. RR WALL TAPE


Vibration-damping underlay for
CEILING

sound-insulating staggered walls.

10. LOH CEILING HANGER


Used for sound insulation in connection
with suspended plaster ceilings.

14. CHCE ELASTOMER HANGER


For sound insulation in connection with
suspended plaster ceilings.

15. CHCS SPRING HANGER


For the most effective acoustic insulation
for suspended plaster ceilings.

Phone: +45 36 77 88 00
2 Web: www.iac-nordic.dk
E-mail: nordic@iac-nordic.dk
2
www.iac-nordic.dk

Introduction

Acoustic solutions for floors, walls and ceilings

Floating floors are designed to reduce the effects of noise or elastically supported walls can be excellent
and vibration and thus increase the level of comfort in rooms self-contained solutions for sound insulation. Elastic ceiling
adjacent to noisy or vibration-generating activities such as hangers and wall mounts are used for this purpose.
fitness centres, bowling alleys, restaurants, cafés, nightclubs
and industrial halls. In order to achieve an optimum degree of insulation, the
nature of the influences at play and the requirements
Floating floors are also suitable for areas that require a that need to be met are taken into consideration in each
low level of background noise such as recording studios, individual case.
cinemas, concert halls, anechoic chambers, rooms for taking
precision measurements and in buildings that have both The principle behind IAC floating floors provides a high level
office space and industrial production. of acoustic insulation compared with other types of floor
constructions.
A floating floor system consists of a floor with two layers
separated by a layer of elastic material. This intermediate The R'w specification for airborne sound insulation and
layer insulates the floor from the substrate providing the L'n,w specification for step noise levels are weighted
acoustic insulation as well as insulating against noisy values, where low-frequency noise is weighted very low.
footsteps. Sound-absorbing materials in the cavity further This means that these specifications are not descriptive in
increase the soundproofing level. situations with loud, modern music with a lot of bass notes.
The advantages of a floating floor at these low frequencies
A floating floor can be a part of a room in a whole-room can be substantially greater than the weighted standard
solution, combined with wall mounts and ceiling hangers. specifications suggest. This can be a very important
In situations with little flanking transmission, elastically consideration since bass notes can easily travel over long
suspended ceilings distances in buildings.

Phone: +45 36 77 88 00
Web: www.iac-nordic.dk 3
E-mail: nordic@iac-nordic.dk
www.iac-nordic.dk

PUR Foam VIKAFOAM

Product description

VIKAFOAM is a cellular elastomer, manufactured from a


special type of polyether urethane elastomer. The product
is used in mechanical industries and in construction as
vibration insulation. Floating floors are constructed of
VIKAFOAM and concrete or wood, which together provide
particularly effective noise attenuation and vibration
insulation. The system can be used for projects large and
small and it is very flexible.

Application

VIKAFOAM is often used as a structural soundproofing


material in buildings, either beneath individual building
components or to separate entire buildings from their
foundations.

Attenuation

The VIKAFOAM material has a uniform and well-defined


attenuation capacity. Internal attenuation for VIKAFOAM is
determined by the mechanical loss factor. For VIKAFOAM,
this value is between 0.1 to 0.3, depending on the density.

Fire performance

VIKAFOAM has been tested in accordance with DIN 4102


and achieved a B2 fire rating (normal combustibility). No
corrosive/caustic fumes occur in the event of a fire. In its
composition, VIKAFOAM should be considered the same as
wood and mineral wool.

Resistance to weather and chemicals

VIKAFOAM is resistant to substances such as water,


concrete, oil, grease, diluted acids and alkalis.

Project Photos

Phone: +45 36 77 88 00
4 Web: www.iac-nordic.dk
E-mail: nordic@iac-nordic.dk
4
www.iac-nordic.dk

PUR Foam VIKAFOAM

IAC VIKAFOAM Types CURVES:


Load range 3 varieties of VIKAFOAM with
10 13 different densities. For more
information, please see our main
website and VIKAFOAM

1 VF 10 Natural Frequency based on E-modulus @ 10Hz

0.020

50 mm

mm

VF 16
37.5 m

25 m

12.5
Load [N/mm²]

0.015

Dynamic Load
0.1

Load [N/mm²]

VF 16

VF 10
0.010

VF 10
Static load
0.01
0.005

VF VF VF VF VF VF VF VF VF VF VF VF VF 0.000
10 16 26 40 65 110 170 260 400 650 950 1300 1900
5 10 15 20 25 30
0,001
VIKAFOAM types Natural Frequency [Hz]

VF 170 Natural Frequency based on E-modulus @ 10Hz

0.35
Natural frequency of a single-degree-of-
37.5 mm
50 mm

25 mm

m
12.5 m

VF 260

freedom system consisting of a fixed mass


0.30
and an elastic bearing consisting of
VIKAFOAM VF 170 on a stiff subgrade.
0.25
Load [N/mm²]

VF 260

VF 170

0.20
Form factor q = 3
VF 110 VF 170

VF 110

0.15

0.10
Dynamic load
Static load

0.05

0.00
5 10 15 20 25 30

Natural Frequency [Hz]

VF 1900 Natural Frequency based on E-modulus @ 10Hz

3.5
Natural frequency of a single-degree-of-
50 mm

mm

mm
25 m

freedom system consisting of a fixed mass


37.5

12.5

3.0
and an elastic bearing consisting of
VIKAFOAM VF 1900 on a stiff subgrade.
2.5
Load [N/mm²]

VF 1900

2.0
Form factor q = 1,25
VF 1900

1.5

1.0
Dynamic load
Static load

0.5

0.0
5 10 15 20 25 30

Natural Frequency [Hz]

Phone: +45 36 77 88 00
Web: www.iac-nordic.dk 5
E-mail: nordic@iac-nordic.dk
www.iac-nordic.dk

MICROCELL ELASTOMER VIKACELL 400

Product description Advantages

VIKACELL is a microcellular elastomer that is especially VIKACELL can be dimensioned for a dynamic natural
flexible and can tolerate up to 75% - 80% compression frequency of 8 Hz at a height of only 30 mm, which is less
without damage to the material. than half the height that other materials need to achieve the
same natural frequency.
Application
Installation
We typically use VIKACELL 400 for floating floors where
acoustic insulation requirements are high. The material can VIKACELL is typically used as blocks that are customized
also be used to set up machinery on a floating foundation for the bearing capacity and requirements for insulation
and also for general placement of machinery. The material efficiency.
was developed for the automotive industry where it is used Normal maximal static load 0.45 N/mm².
as an absorber in the suspension system, so it can handle
long-duration dynamic loading.

Attenuation

The transmission of structure-borne noise with low


frequencies through a floating floor can be attenuated
effectively by designing the floating floor to have a very low
natural frequency.

Neoprene Cellular Rubber Plywood plate Concrete slab

Plastic foil Plywood Pad


Mineral Wool
30mm VIKACELL
From 55 mm

NOTES:
1. VIKACELL Pad
2. VIKACELL and Plywood pad are glued
3. Plywoodplate and Plywood pad are screwet together
4. The Plastic foil is to cover the entire area and is overlapped and taped
5. Perimeter isolation can be Neoprene Cellular rubber used against all building struct

Amager Slope

Phone: +45 36 77 88 00
6 Web: www.iac-nordic.dk
E-mail: nordic@iac-nordic.dk
6
www.iac-nordic.dk

MICROCELL ELASTOMER VIKACELL 400

Natural Frequency based on E-Modulus @ 8 and 16Hz


[Hz] VIKACELL 400. Size 125 x 100 x 30 mm
16

14

12

10

6
0,00 0,05 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50 [N/mm²]
Compression [%] 4 6 9 14 19 25 30

Compression [%] Compression set VIKACELL 400. Size 20 x 20 x 20 mm


70

60

50

40

30

20

10

0
1 10 100 1000 10000 100000
Time [Hours]

Phone: +45 36 77 88 00
Web: www.iac-nordic.dk 7
E-mail: nordic@iac-nordic.dk
www.iac-nordic.dk

Jack-Up Floor FZH

Product description Usage

FZH Jack Up System for concrete floors is used in recording Usage is about 1.12 attenuators per m², which varies slightly
studios, office environments and in production halls. There in relation to the thickness of the concrete and the amount
may also be other locations where you want to reduce the of reinforcement.
disturbance from noisy footsteps or other structure-borne
noise from entering a room. The system also works in the Advantages
other direction, so that noisy footsteps or the sound of a
drum set inside a studio is optimally deadened in the rest of The system's clear advantage is that it ensures that there is
the building. no interference, because when the floor is raised, there is no
contact with the sub-floor.
Application

You can choose between 10 different attenuators depending


on the load they are subjected to and the natural frequency
of the floor you want. See the chart with the various
attenuators below.

20

Load Natural fre-


Type
[Kg] quency [Hz]
FZH140-25 140 11.3
105
90

FZH140-37 140 8.9


55

FZH240-25 240 11.2


FZH240-37 240 8.6
FZH490-25 490 10.5
125 FZH490-37 490 8.2
135 FZH800-25 800 11.9
167 FZH800-37 800 9.1
FZH965-25 965 11.7
FZH965-37 965 8.4

Phone: +45 36 77 88 00
8 Web: www.iac-nordic.dk
E-mail: nordic@iac-nordic.dk
8
www.iac-nordic.dk

Steel Floor STEEL FLOOR

Product description
Application
Low profile Steel Floor, constructed of two 6 mm thick
steel plates separated by Neoprene rubber, which rests on The total floor structure is 50 mm high and the resonant
either VIKAFOAM or VIKACELL vibration absorbers. These frequency for vibrations in the room is less than 11 Hz.
ensure effective vibration insulation against noise from the Attenuation at 60 Hz is at least 30 dB and at 120 Hz it
building's concrete floors. Noise from the building's concrete is more than 45 dB. The floor height can be increased to
floor can originate from vibrations caused by noisy footsteps achieve a lower resonant frequency.
or machines located in other parts of the building. Noise
can also come from nearby train or subway lines, and from The relatively low installation height of the floor makes it
nearby roads with heavy traffic. easier to accommodate access for wheelchair users and
it can be incorporated in most rooms while keeping a
The floating steel floor prevents airborne and structure- comfortable ceiling height.
borne noise from entering the room.

3591 4298

Lower Floor Plate Upper Floor Plate


6mm Steel Plate
Layout Layout
Neoprene Sheet
6mm Steel Plate

Vibration Insulating U-Rail


50

25mm Rockwool

Phone: +45 36 77 88 00
Web: www.iac-nordic.dk 9
E-mail: nordic@iac-nordic.dk
www.iac-nordic.dk

Vikas Ceiling hanger Wall mount LOH-VB

Product description

Two electro-galvanised steel brackets separated by a


vibration absorber. The ceiling hangers and wall mounts
effectively insulate against vibrations/sound transmissions in
the audible frequency range.

Application

Ceiling hangers are used for sound insulation in connection


with suspended flat plaster ceilings. The hangers are
constructed to bear the load and to vibration-proof the
plaster ceiling from the existing ceiling. Wall mounts are used Installation
for fastening sound-insulating staggered walls.
The sound ceiling should hang freely without direct contact
Attenuation with the existing ceiling, walls, pipe penetrations, etc.
The sound-insulating wall is mounted without direct contact
Field measurements show that the sound-insulating ceiling with existing walls, ceiling and pipe penetrations, etc.
improves sound insulation in upper-storey floors by up to Joints between the acoustic ceiling and walls, pipes, wires,
10 dB. The sound reduction index R'w is typically 58 - 60 dB etc. are sealed with an elastic sealant.
after proper installation of the ceiling, but depends on the
existing ceiling construction. Usage

A sound-insulating staggered wall reduces airborne Approx. 1.4 ceiling hangers per m² of ceiling with 2 layers of
transmitted noise by 8-12 dB, depending on the plasterboard (~Load: approx. 18 kg/hanger).
existing wall construction.
Approx. 1.5 ceiling hangers per m² of ceiling with 3 layers of
Advantages plasterboard (~Load: approx. 23 kg/hanger).

• The ceiling hanger and wall mount insulate optimally Approx. 4.5 wall mounts per linear meter of wall (ceiling
against airborne noise. height 2.5 – 3.1m).
• Fireproof construction. Cladding class 1 (DS 1065.2)
• Easy to install and can cover up irregularities in the Note
existing ceiling and wall
Dimension X can be between 65 and 1200mm
4
6.
Ø

30
X
X

10
10

68
60 70 114.5
155
60mm Hanger for 70mm Hanger for
CD 60/27 profiles MR 70 profiles

Phone: +45 36 77 88 00
10 Web: www.iac-nordic.dk
E-mail: nordic@iac-nordic.dk
10
www.iac-nordic.dk

Vikas Ceiling hanger Wall mount LOH-VB

General

The fittings are delivered unassembled and consist of the It is also important to include the following in the design:
following components:
All joints must be soundproof at walls and penetrations.
Ceiling hangers: 1 Ceiling brace, vibration absorber incl. 2 Joints are sealed with an elastic sealant.
screws and strap with a length from 65 - 1200mm Light fixtures and the like, which penetrate the ceiling, need
to be fitted with a soundproof superstructure.
Wall mounts: 1 wall brace, 2 vibration absorbers incl. If heavier items are suspended from the ceiling, additional
1 screw, 1 set-screw and strap with a length from 65 - ceiling hangers need to be installed to accommodate the
1200mm increased load.
(Each hanger can have a max. load of 28 kg.)
UD 28/27 If a staggered wall will bear an additional load from heavier
MSK 45
m
items, etc., additional wall mounts should be installed.
0m
160 mm
0
ard 50
bo rd 1
ster boa
pla er
rs last
Laye rs p
2 aye Rail CD 60/27 or MR 70
3L Vikas Ceiling hang
ger

Mineral Wool
45 Min 50mm
0m
m
1200 mm

m
0m
45 Ca. 200-300mm

Mineral Wool min 50mm


min 65 mm

Vikas Wall moun


nt
1600 mm

2- 3 llayers
2
UD 28/27 for CD60/27 + 3mm RR Plaster Board
MSK 45P fo
for M
MR 70 + 3mm RR i
min
65 mm
Vikas elastic sealan
nt

Mineral Wool min. 50


M 0mm

Phone: +45 36 77 88 00
Web: www.iac-nordic.dk 11
E-mail: nordic@iac-nordic.dk
www.iac-nordic.dk

Wall mount VBS-160

Product description
The wall fitting is quick and easy to install and can be used
Sound-insulation wall mount. The fittings are electro- with various types of steel profiles.
galvanised steel with vibration insulators of thermoplastic
elastomer. Installation

Application The wall can be erected on VVB (3 mm thick wall tape, p 13)
Wall mounts are used for fastening sound-insulating without a fixed connection to the existing walls, ceilings and
staggered walls. The fitting is not designed to bear the pipe penetrations, etc.
wall but to support it. They are designed to work for both
compression and tension: During installation, joints between the acoustic ceiling and
Compression: under varying loads up to 40 kg. wall, pipes, wires, etc. are sealed with an elastic sealant
Tension: under varying loads up to 30 kg. (acoustic sealant).
Mechanically fireproof
Usage
Attenuation Approx. 6 wall mounts per linear meter of wall
at a ceiling height of 2.4 – 3.2 m
A sound-insulating staggered wall reduces air-transmitted
noise by 8-12 dB depending on the existing wall
construction.

Advantages

The wall mounts provide good mid-range audio insulation. A


special version with a steel spring provides optimal insulation
for lower frequencies.

27 Measured Natural Frequency [Hz]


3
17

15

13
Tension Load
Snit B - B
1,5

13 11
27 120
9
20 20 R8 Compression Load

5
B B 0 5 10 15 20 25 30 35 40
Load [kg]

60
Ø 6,5

160
50
80

Phone: +45 36 77 88 00
12 Web: www.iac-nordic.dk
E-mail: nordic@iac-nordic.dk
12
www.iac-nordic.dk

Wall tape RR

Product description

Acoustic insulation for wall bottom rails. Wall tape is self-


adhesive on one side and is made of SBR fibres and granular
rubber. Wall tape provides good structure-borne noise
insulation despite being relatively thin.

Application

Wall tape is used as a structural soundproofing material


under plaster walls in buildings. Wall tape acoustically
separates plaster wall bottom rails from the floor. Wall tape
is affixed under the bottom rail of plaster walls.

Fire performance

Wall tape has a B2 fire rating according to DIN 4102.


Load per meter [kg]
250
Specifications

• Thickness 3 mm
200
• Width 50 mm
• Roll length 20 m
• Dynamic stiffness per linear meter 3500 N/mm
150
• Typical bottom rail MSK 45

100

50

0
0 0,3 0,6
Deflection [mm]

Creep per meter (%)


10

0
0 12 24 36 48 60
250 Kg Time (Month)
Load
100 Kg

Phone: +45 36 77 88 00
Web: www.iac-nordic.dk 13
E-mail: nordic@iac-nordic.dk
www.iac-nordic.dk

Click bracket Elastomer CHCE6027

Product description Installation

Sound-insulating click bracket for suspended plaster ceilings. Installation with the click system is quick and easy. Mount
The fittings are electro-galvanised steel with vibration the brackets at the correct height on the threaded rods and
insulators of thermoplastic elastomer. click the profiles in place. Push the safety device into place
with your finger, and the ceiling is finished.
Click brackets come in two types: The sound ceiling should hang freely without direct contact
GREEN for loads between 10 kg and 32 kg. with the other walls, ceiling, pipe penetrations, etc.
BLUE for loads between 22 kg and 57 kg.
Usage
Click brackets are available for M6 and M8 threaded rods
Safety device withstands pressures exceeding 326 kg. The The decisive factor for choosing the type and number of
service life is 30 years. EN 13964-2006. ceiling brackets will often be the deflection of the 60/27
profiles. So the choice will often go to the green type.
Application

Click brackets are used for sound insulation in connection


with suspended flat plaster ceilings. The brackets are
designed to bear the gypsum ceiling and make it vibration- Measured Natural Frequency [Hz]
proof from the existing ceiling. It is suitable for loads 15
between 17 kg and 57 kg. CHCE6027 Green
14
Attenuation
13
Field measurements show that sound-insulating ceilings
improve sound insulation in upper-storey floors by up to 10 12
dB. The sound reduction index R' is typically 58 - 60 dB after
proper installation of the ceiling, but depends on the existing 11
ceiling construction. CHCE6027 Blue
10
Advantages 10 20 30 40 50 60
Load [kg]
Click brackets provide good mid-range audio insulation. A
special version with a steel spring provides optimal insulation
for lower frequencies. Click brackets are quick and easy to
install.

Section B-B

Dimensions including rail

Phone: +45 36 77 88 00
14 Web: www.iac-nordic.dk
E-mail: nordic@iac-nordic.dk
14
www.iac-nordic.dk

Click bracket Spring CHCS6027

Product description somewhat less, depending on the ceiling construction and


flanking transmission through the walls.
Sound-insulating ceiling hangers for plaster ceilings
suspended with 60/27 profiles. The fittings are electro- Advantages
galvanised steel with steel springs of thermoplastic
elastomer as vibration insulation. The ceiling hangers insulate well throughout the audible
Click hangers are available in four types: frequency range - even against low tones. The ceiling
hangers are quick and easy to install.
GREY for loads between 3 kg and 15 kg
GREEN for loads between 15 kg and 30 kg Installation
BLUE for loads between 30 kg and 51 kg
RED for loads between 50 kg and 76 kg Installation with the click system is quick and easy. Mount
the hangers at the correct height on the threaded rods and
Click hangers are available for M6 and M8 threaded rods. click the profiles in place. Push the safety device into place
with your finger, and the ceiling is finished.The sound ceiling
Safety device withstands pressures exceeding 326 kg. The should hang freely without direct contact with the other
service life is 30 years. EN 13964-2006. walls, ceiling, pipe penetrations, etc.

Application
Measured Natural Frequency [Hz]
Ceiling hangers are used for sound insulation in connection 15
with suspended flat plaster ceilings. The hangers are
designed to bear the gypsum ceiling and make it vibration- 13
proof from the existing ceiling. It is suitable for loads
between 3 kg and 76 kg. 11

Attenuation 9

Laboratory measurements show that sound-insulating 7


ceilings with spring hangers improve sound insulation in
upper-storey floors by up to 30 dB.
5
The sound reduction index R'W is typically 72 - 84 dB after
proper installation of the ceiling, but depends on the existing
ceiling construction. In practice, the improvement will be 0 20 40 60 80
Load [kg]

61
95

103
94

M6&M8

Dimensions including rail

Phone: +45 36 77 88 00
Web: www.iac-nordic.dk 15
E-mail: nordic@iac-nordic.dk
www.iac-nordic.dk

oustics also carry a large stock selection of Anti vibration mounts,


IAC Acoustics
ubber pads, Ruber Bearings, Shock Isolators and much more.
Rubber

se of our more than 30 years of experience in noice and vibrations atten


So call us and make use attenuation