Technical Data: (Main)
Size To be advised
later
Length 280 mm
Material Kevlar, Nitrile
Butadiene
Test results: (EN388)
Abrasion Resist: (1-4): Rating 3
Cut Resistance: (1-5): Rating 5
Tear Resistance: (1-4): Rating 4
Prick Resistance: (1-4): Rating 4
Application:
Working Overall
Code: PPE-01-05
Technical Data: (Main)
Size To be defined later
Material Polyester/Cotton
hardwearing, > 260
gr/m²
Application:
Safety Boots
Code: PPE-01-06
Technical Data: (Main)
Size To be defined later
Material shoe Leather with rubber
Material sole Double density
polyurethane
Safety Category: EN345 (200 Joules)
with steel toe-cap
Application:
Application:
Soap dispenser
Code: PPE-02-03
Technical Data: (Main)
Size: 500 ml
Material: Plastic / metal
Application:
B) Consumables
Reducing UPOPs and Mercury Releases from The Health Sector in Africa
C) Small equipment
Reducing UPOPs and Mercury Releases from The Health Sector in Africa
Application:
Needle Cutter
Code: LOG-02-10
(Debris Pots: LOG-01-11)
Technical Data: (Main)
Volume 0,01 kg / h
Material Stainless Steel –
debris pot: plastic
Application:
Application:
Material Polyethylene
Application:
Application:
Digital universal ground scale for the
weighing of different kind of bins and
containers.
Application:
Application:
hold a loading trolley with an effective volume of not less than 275 l. Bidder shall
indicate the inside dimension of the loading trolley offered in HxWxL in mm.
❑ Double-jacket pressure chamber shall be thermally insulated with environmental
friendly materials. Bidder to indicate insulation materials here.
❑ Working pressure:2 bar (0.2 MPa). Tested at 5 bar
❑ Chamber shall be made of stainless steel construction.
❑ Main shell – 304L stainless steel; jacket cells – A240 type 304L stainless steel
❑ Chamber provided with rails to allow smooth loading of loading rack
❑ Front panel and casing in stainless steel
Door:
❑ Shall be a single door system and the door shall be made of stainless steel material
equivalent to the standard specified above for the chamber
❑ Quick opening sliding door with expanding gasket
❑ The door should be thermally insulated with environmental friendly materials sealed
with silicon gasket.
❑ A safety mechanism shall be provided to prevent the cycle being started until the door
is locked and sealed and to prevent the door being opened until chamber pressure is at
atmospheric pressure.
Vacuum pump and steam generator:
❑ Treatment Equipment shall be provided with a built-in automatic electric steam
generator, capacity adapted to needs. With average steam pressure up to 2 bar
(0.2MPa)
❑ With controlled pressure valve for steam release to prevent over boiling of liquid
products.
❑ The Treatment Equipment shall be provided with a built-in steam ejector system
capable of achieving -60 kPa;
❑ Meets section 8.2.2 of EN 285:2006+A2:2009 (i.e., uniform colour change throughout a
Bowie-Dick indicator when tested on the empty Treatment Equipment)
❑ The process shall include pulsating pre-vacuum and post vacuum phase for effective
air removal from the chamber, it shall also include a drying phase.
Controls:
❑ Recording: Recording of temperature using a graph or printout; printed records should
be readable for 3 years.
❑ Overpressure safety relief valve and pressure limiting
❑ Control to keep the pressure below the maximum allowable pressure
❑ Display indicators: Pressure gauge readable by normal vision from a distance of (1.00 ±
0.15) m
❑ Indicator for temperature ± 1% accuracy or better over the scale range 50°C to 150°C
❑ Indicator for pressure ± 1.6% or better over the scale range -1 bar to 3 bar
Chamber Drain System:
❑ Steam and condensate discharged from the chamber shall be cooled by a high
capacity water cooled condenser to reduce discharge temperature to less than 60
degrees C to avoid risk of damage to the building drainage system.
❑ Condenser shall be made of stainless steel with large cooling surface.
❑ With validation ports for external temperature sensors for validation and qualification
checking purposes.
❑ The Treatment Equipment offered must comply with the directives and requirements
specified in the relevant safety standards below:
o European Committee for Standardization (CEN)
o EN285 (Norm for large sterilizer) or must exceed STAATT Level III microbial
inactivation efficacy criterion
o IEC 60601 Electrical equipment for medical use or IEC 61010-2-040, UL
61010A-2-041, or equivalent electrical safety standard.
o Other relevant accepted safety standards
Reducing UPOPs and Mercury Releases from The Health Sector in Africa
Monitoring equipment
Code: TRE-03-02
Technical Data: (Main)
See below See below
Application:
❑ Tools made of high quality. All components chrome vanadium steel with chrome mirror
finish or full shock-resistant plastic
Reducing UPOPs and Mercury Releases from The Health Sector in Africa
Code: TRE-03-07
Software Included
Application:
Data logger
Data record up to 10000 readings per channel
± 0.1% of reading +0.7°C (-100°C to +
Accuracy
1300°C)
Resolution 0.1°C/°F/K
Power supply 4 AAA batteries
Thermocouple
Semi rigid thermocouples
Mineral Insulated Thermocouple with Pot Seal
Insulated junctions to prevent earth loops and can be formed to shape to
suit particular applications without impairing performance.
Range of temperature - 100 – 1300 °C
Diameter 3.0 mm
Length 2000 mm
To be included: Vacuum and pressure proof connector for validation port (1/2”) for external
temperature sensors for validation and qualification checking purposes.
Reducing UPOPs and Mercury Releases from The Health Sector in Africa
Code: TRE-04-01
Application:
Requested Throughputs:
• Kitchen waste, bones, food leftovers, wet waste: ca. 100 kg/h
• Plastic containers up to 2 l: ca. 100 kg/h
• Metal containers up to 2 l: ca. 150 kg/h
• Syringes, tubes: ca. 100 kg/h
• Turnings: ca 1,5 m³/h
The shredding machine must follow the operating principle of rotor blades
• Two shafts rotating in opposed cutting directions.
• If a fault occurs, the cutting unit must stop automatically.
• After fault, the cutting unit must go into reverse and then rotates again in cutting
direction.
Further Requirements:
• The machine must be a smoothly and slowly running cutting unit ensures low dust,
vibration and noise generation.
• Must have an extremely robust design guarantees high operating safety and low
susceptibility to faults.
• Must include an overload protection which is linked to motor speed and temperature
to protect the machine and minimize failures.
• Make-up welding must ensure low cost of wear and tear.
Reducing UPOPs and Mercury Releases from The Health Sector in Africa
Code: TRE-04-02
Application:
Requested Throughputs:
• Plastic containers up to 20 l: ca. 150 kg/h
• Metal containers up to 10 l: ca. 400 kg/h
• Glass, bottles: ca. 1,5 m³/h
• Biowaste, bones: ca 1,5 m³/h
• Turnings: ca 2 m³/h
The shredding machine must follow the operating principle of rotor blades
• Two shafts rotating in opposed cutting directions.
• If a fault occurs, the cutting unit must stop automatically.
• After fault, the cutting unit must go into reverse and then rotates again in cutting
direction.
Further Requirements:
• The machine must be a smoothly and slowly running cutting unit ensures low dust,
vibration and noise generation.
• Must have an extremely robust design guarantees high operating safety and low
susceptibility to faults.
• Must include an overload protection which is linked to motor speed and temperature
to protect the machine and minimize failures.