4-Digit Multi Panel Meters


Ordering Information Cautions during Wiring Specifications

MT4Y Series
This is only for reference, the actual product does not support all combinations. Use the Copper-conductor wire with the temperature class 60 ℃. Model MT4Y-DV-4□ MT4Y-DA-4□ MT4Y-AV-4□ MT4Y-AA-4□
For selecting the specified model, follow the Autonics website. • Unit: mm, Use terminals of size specified • Contact the manufacture for the socket Input type DC voltage DC current AC voltage 01) AC current 01)
below. and cable.

INSTRUCTION MANUAL
Max. allowable input 10 to 110 % F.S. for each measured input range
MT 4 Y - ❶ - ❷ ❸ Model Display method 7-segment (red) LED (character height: 14.2 mm)
Hirose connector HIF3BA-14PA-2.54DS Display accuracy Dependent on the ambient temperature
❶ Input type ❷ Power supply Hirose connector ± 0.1 % F.S. rdg ± 0.1 % F.S. rdg ± 0.3 % F.S. rdg ± 0.3 % F.S. rdg
DV: DC voltage 01) 4: 100 - 240 VACᜠ ± 10 % 50 / 60 Hz HIF3BA-14D-2.54R 23 ± 5 ℃
socket ± 2 digit ± 2 digit 02) ± 3 digit ± 3 digit
DA: DC current ≥3.5 2 14 -10 to 50 ℃ ± 0.5 % F.S. rdg ± 3 digit
TCD220016AE
AV: AC voltage 02) ≤7.0 Max. display range -1999 to 9999 (4 digit)
AA: AC current 02) A / D conversion
ΣΔ (Sigma Delta) ADC
13 method
❸ Preset output + Sub output
Thank you for choosing our Autonics product. 1 Sampling cycle 50 ms 16.6 ms
Read and understand the instruction manual and manual thoroughly before Preset output Sub output Protection rating IP56 (front part, IEC standard)
using the product. N None (indicator)
Connections
Unit weight
≈ 134 g (≈ 213.5 g)
For your safety, read and follow the below safety considerations before using. 0 Relay - (packaged)
For your safety, read and follow the considerations written in the instruction Certification ᜢ᜽ᜧᜫ
1 NPN open collector - ■ Input
manual, other manuals and Autonics website. 01) Available frequency display, Display accuracy (23 ± 5 ℃): ± 0.1 % F.S. rdg ± 2 digit
2 PNP open collector - • DC voltage • DC current
Keep this instruction manual in a place where you can find easily. SOURCE SOURCE
02) 5
 A terminal: ± 0.3 % F.S. rdg ± 3 digit
3 Relay (Low out) Transmission (DC 4 - 20 mA)
The specifications, dimensions, etc. are subject to change without notice for product 100 - 240 VACᜠ 100 - 240 VACᜠ
None (indicator) / Relay / NPN open collector / PNP open collector
4 Relay (Low out) RS485 Communication 50 / 60 Hz 5 VA 50 / 60 Hz 5 VA Preset output
improvement. Some models may be discontinued without notice. output model
Follow Autonics website for the latest information. 5 - BCD Dynamic
Contact capacity: 250 VACᜠ 3 A, 30 VDCᜡ 3 A
Relay
6 - Low speed serial 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Contact composition: N.O (1a)
01) To measure the current over DC 5 A, please select DV type because the shunt should be used. 250 mVDCᜡ / 50 mVDCᜡ 5 mA / 2 mA NPN / PNP
Output capacity: ≤ 12 - 24 VDCᜡ ± 2 VDCᜡ, 50 mA resistive load
Safety Considerations 02) In case of selecting frequency display, no output will be provided even if it is output support model. 5 VDCᜡ / 1 VDCᜡ 50 mA / 4 - 20 mA open collector
50 VDCᜡ / 10 VDCᜡ 500 mA / 200 mA None (indicator) / BCD Dynamic / Transmission (DC 4 - 20 mA) /
Sub output
• Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards. 500 VDCᜡ / 100 VDCᜡ 5A/2A Low speed serial / RS485 Communication output model
Product Components
COM COM
• ᜸ symbol indicates caution due to special circumstances in which hazards may occur. BCD Dynamic / NPN open collector output
• AC voltage • AC current
Low speed serial Output capacity: ≤ 12 - 24 VDCᜡ, 50 mA resistive load
SOURCE SOURCE
᜸ Warning Failure to follow instructions may result in serious injury or death. • Product • Instruction manual 100 - 240 VACᜠ 100 - 240 VACᜠ
Transmission
Resolution: 1/12,000 (load resistance: ≤ 600 Ω)
• Bracket × 2 • Unit sticker × 1 50 / 60 Hz 5 VA 50 / 60 Hz 5 VA Response time 01): ≤ 550 ms
(DC 4 - 20 mA)
Output accuracy (23 ± 5 ℃): ± 0.3 % F.S.
01. Fail-safe device must be installed when using the unit with machinery that
may cause serious injury or substantial economic loss. (e.g. nuclear power RS485 communication Protocol: Modbus RTU
Sold Separately
1 2 3 4 5 6 7 1 2 3 4 5 6 7
control, medical equipment, ships, vehicles, railways, aircraft, combustion 01) Based on the display cycle of 0.2 seconds.
apparatus, safety equipment, crime / disaster prevention devices, etc.) 2 VACᜠ / 1 VACᜠ 100 mA / 50 mA Deviations may occur depending on the device environment and the display cycle of the product.
Failure to follow this instruction may result in personal injury, economic loss or fire. • Terminal protection cover: M6P / M7P-COVER 20 VACᜠ / 10 VACᜠ 500 mA / 250 mA Response time: Time taken to proportional output to the rapidly changing input from 15 → 95 % or 95 → 15 %.
02. Do not use the unit in the place where flammable / explosive / corrosive gas, 110 VACᜠ / 50 VACᜠ 1A
high humidity, direct sunlight, radiant heat, vibration, impact or salinity 500 VACᜠ / 250 VACᜠ 5 A / 2.5 A Power supply 100 - 240 VACᜠ 50 / 60 Hz
COM COM
may be present.
Manual
Permissible voltage
90 to 110 % of rated voltage
Failure to follow this instruction may result in explosion or fire. ■ Output range
03. Install on a device panel to use. Power consumption 5 VA
Failure to follow this instruction may result in fire or electric shock. For proper use of the product, refer to the manuals and be sure to follow the safety • 0: Relay • 1: NPN open collector
04. Do not connect, repair, or inspect the unit while connected to a power source. considerations in the manuals. Insulation resistance Between external terminal and case: ≥ 100 MΩ (500 VDCᜡ megger)
8 9 10 11 12 13 8 9 10 11 12 13
Failure to follow this instruction may result in fire or electric shock. Download the manuals from the Autonics website. Between the charging part and the case: 3,000 VACᜠ 50 / 60 Hz for 1
Dielectric strength
05. Check ‘Connections’ before wiring. min
Failure to follow this instruction may result in fire. HOLD / ZERO HOLD / ZERO
Noise immunity ± 2 kV square wave noise (pulse width: 1 ㎲) by the noise simulator
HI GO LO COM HI GO LO COM
06. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire or electric shock. Software Vibration
0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y,
• 2: PNP open collector • 3: Relay + Transmission (DC 4 - 20 mA) Z direction for 2 hours
᜸ Caution Failure to follow instructions may result in injury or product damage. Download the installation file and the manuals from the Autonics website. 8 9 10 11 12 13 8 9 10 11 12 13 Vibration 0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z
■ DAQMaster + - (malfunction) direction for 10 min
01. When connecting the power / measurement input and relay output, use It is the comprehensive device management program for Autonics' products, providing HOLD / ZERO DC 4 - 20 mA OUT1 HOLD / ZERO Shock 300 m/s2 (≈ 30 G) in each X, Y, Z direction for 3 times
HI GO LO COM LOAD 600Ω 이하
AWG 24 (0.20 mm2) to AWG 15 (1.65 mm2)cable or over and tighten the parameter setting, monitoring and data management. Shock (malfunction) 100 m/s2 (≈ 10 G) in each X, Y, Z direction for 3 times
terminal screw with a tightening torque of 0.98 to 1.18 N m.
• 4: Relay + RS485 comm. • 5: BCD Dynamic Mechanical: ≥ 20,000,000 operations
Use the wiring suitable for the load current capacity. Relay life cycle
HOLD / ZERO Electrical: ≥ 100,000 operations (250 VACᜠ 3A resistive load)
Failure to follow this instruction may result in fire or malfunction due to contact
failure. Dimensions Ambient temp. -10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
02. Use the unit within the rated specifications. 8 9 10 11 12 13 2 4 6 8 10 12 14 Ambient humi. 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Failure to follow this instruction may result in fire or product damage. • Unit: mm, For the detailed drawings, follow the Autonics website. B(-) A(+)
A C D0 D2 DOT Symbol: , double or reinforced insulation (dielectric strength between
03. Use a dry cloth to clean the unit, and do not use water or organic solvent. Insulation type
72 6 77 RS485 OUT1 HOLD / ZERO the measurement input part and the power part: 1 kV)
Failure to follow this instruction may result in fire or electric shock. COM B D D1 D3 POL
04. Keep the product away from metal chip, dust, and wire residue which flow
into the unit. 1 3 5 7 9 11 13
Failure to follow this instruction may result in fire or product damage.
• 6: Low speed serial
Communication Interface
30.2
36

POL: When a display value is (-) the signal of (-) will be outputted.
■ RS485
Cautions during Use • Except) BCD Dynamic sub output model
HOLD / ZERO
Comm. protocol Modbus RTU
• Follow instructions in ‘Cautions during Use’. 72 6 66.5 10.5 8 9 10 11 12 13 Application standard Compliance with EIA RS485
Otherwise, It may cause unexpected accidents.
• Power supply should be insulated and limited voltage / current or Class 2, SELV power Max. connection 31 units (address: 01 to 99)
COM
supply device. Comm. synchronous method Asynchronous
CLOCK DATA LATCH POL
• Install a power switch or circuit breaker in the easily accessible place for supplying or Comm. method 2-wire half duplex
30.2

disconnecting the power.


36

• Use twisted pair wire for communication line. Comm. distance ≤ 800 m
• Keep away from high voltage lines or power lines to prevent inductive noise. Comm. speed 1,200 / 1,400 / 4,800 / 9,600 / 19,200 / 38,400 bps
In case installing power line and input signal line closely, use line filter or varistor at ■ Bracket ■ Panel cut-out
Start bit 1-bit (fixed)
power line and shielded wire at input signal line. ≥ 91
Do not use near the equipment which generates strong magnetic force or high Data bit 8-bit (fixed)
frequency noise.
4

Parity bit None, Even, Odd


9

Connection with the line filter Connection with the varistor 60


31.5+0.5

Stop bit 1-bit, 2-bit


0

Install the line filter EEPROM life cycle ≈ 1,000,000 operations (Erase / Write)
≥ 40
14.5

close to the panel meter


12

Panel meter 68
Panel meter
+0.7
0

HI
HI 110 / 220 VACᜠ
110 / 220 VACᜠ LOW
LOW

Earth ground
• This unit may be used in the following environments.
- Indoors (in the environment condition rated in ‘Specifications’)
- Altitude max. 2,000 m
- Pollution degree 2
- Installation category II
-|Transparent Guide|-

Mode Setting ■ Parameter 2 group Input Range and Display Range Output Operation Mode
Display When the max. input value is over the 100 %, it may result in input terminal damage. • H.SET or L.SET is displayed according to the output operation mode setting. In case of output
Parameter Mark Defaults Setting range
Parameter 1 condition operation mode as OFF, H.SET and L.SET are not displayed.
[MODE] 3 sec → [MODE] 3 sec →
group [Except indicator model] ■ DC voltage model • When changing output operation mode, high-limit / low-limit output setting value, hysteresis
OFF, L.ST, H.ST, LH.ST, HH.ST, LL.ST, are reset.
Parameter 2 Output Display range Input
LD.ST Input range
[MODE] 5 sec → [MODE] 3 sec → 2-1 operation - Diaplay method: STND (fixed) Diaplay method: SCAL impedance
Preset output
• Refer to Output Operation Mode
01)
group
OUtT OFF
mode MODE Output operation
• Relay (Low out) output model is 0 - 500 VDCᜡ 0.0 to 500.0 4.33 MΩ LO ON HI ON GO ON
Parameter 0 available only OFF or L.ST.
500V
RUN RUN 0 - 100 VDCᜡ 0.0 to 100.0 4.33 MΩ
[MODE] → [MODE] 3 sec → Decimals Display range
group H.SET
100V
[Except indicator model] 2-1 0 - 50 VDCᜡ 0.00 to 50.00 433.48 kΩ
ON
2-2 Hysteresis OFF H
Within 10 % of max. display range, digit Output 0 -1999 to 9999 L.SET
HYS 001 50V
0 - 10 VDCᜡ 0.00 to 10.00 433.48 kΩ H: Hysteresis
[◀] + [▲] 3 sec → Zero adjustment Auto → operation 10V
)0 -199.9 to 999.9
Startup mode: 0 - 5 VDCᜡ 0.000 to 5.000 43.48 kΩ
[Except indicator model] No output
2-3 compensation except )00 -19.99 to 99.99
5V
0.0 to 99.9 sec
OFF
0 - 1 VDCᜡ 0.000 to 1.000 43.48 kΩ
STaT 0)0
time OFF GO
[◀] + [▲] + [▼] 5 sec → Reset [MODE] → )000 -1.999 to 9.999 L.SET ≥ L.SET <
1V
0 - 250 mVDCᜡ 0.0 to 250.0 2.28 kΩ -
Peak LO H Display value Display value
)25V lST

2-4 monitoring 00 S 00 to 30 sec - 0 - 50 mVDCᜡ 0.00 to 50.00 2.28 kΩ


HI H H.SET ≤ H.SET >
PEkT 50MV
delay time 01) C
 onnect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input -
GO Display value Display value
hST

Parameter Setting
range to measure.
2-5 Display cycle DIsT )2 S 0.1 to 5.0 sec - When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
HI H
NO, YES L.SET <
L.SET ≥ H.SET ≤
• Some parameters are activated / deactivated depending on the model or setting of 2-6
Keys for zero
NO • YES: Press the [◀] + [▲] keys for 3 - ■ DC current model GO
Display value Display value
Display value
adjustment
ZERO LhST
other parameters. Refer to the description of each parameter. sec to adjust zero. < H.SET
Display range Input LO H
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode. [Except indicator model] Input range
impedance
• After returning to RUN mode, press the [MODE] key within 2 sec, it returns to Diaplay method: STND (fixed) Diaplay method: SCAL 01)
HI H
External HOLD, ZERO L.SET ≤ H.SET ≤ L.SET >
previous parameter. 2-7 input HOLD • If the external input terminal is - 0-5A 0.000 to 5.000 0.02 Ω GO
• [MODE] key: Saves current setting value and moves to the next parameter. Display value Display value Display value
EVIN 5A HhST
terminal short-circuited for 50 ms or more, it 0-2A 0.000 to 2.000 0.02 Ω LO H
[◀] key: Checks fixed value / Changes setting digits. operates with the set function. Decimals Display range
2A

[▲], [▼] key: Changes setting values. 0 - 500 mA 0.0 to 500.0 0.22 Ω HI H
0 -1999 to 9999
)5A
[DC voltage & Transmission (DC 4 - 20 0 - 200 mA 0.0 to 200.0 0.22 Ω L.SET ≥ H.SET ≥ H.SET <
■ Parameter 1 group mA) output model], )0 -199.9 to 999.9 GO
)2A
Display value Display value Display value
LlST
50)0 [AC voltage & Transmission (DC 4 - 20 0 - 50 mA 0.00 to 50.00 2.22 Ω
)00 -19.99 to 99.99 LO H
50MA
Display mA) output model]
Parameter Mark Defaults Setting range High-limit 4 - 20 mA 4.00 to 20.00 2.22 Ω
condition Max. value of display range )000 -1.999 to 9.999
4-20
value of 0 - 5 mA 0.000 to 5.000 22.22 Ω Second L.SET
2-8 - GO L.SET <
[DC voltage model], [AC voltage model] transmission ≥ Display -
5MA
[DC current & Transmission (DC 4 - 20
FS-H
- 0 - 2 mA 0.000 to 2.000 22.22 Ω H Display value
• Refer to Input Range and Display Range output
LdST
mA) output model], LO value
500V 2MA
1-1 Input range
[DC current model], [AC current model] %000 [AC current & Transmission (DC 4 - 20 01) C
 onnect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
IN-R
- mA) output model] range to measure.
• Refer to Input Range and Display Range
5A
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
Max. value of display range
Display STND: standard, SCAL: scale,
1-2
method
DISP STND
FREQ: frequency 01)
- [DC voltage & Transmission (DC 4 - 20 ■ AC voltage model Reset
mA) output model],
[AC voltage model], [AC current model] Display range Input
00)0 [AC voltage & Transmission (DC 4 - 20 Input range 01. Press the [◀] + [▲] + [▼] keys for over 5 sec. in run mode, INIT turns ON.
T.RMS: True RMS, A.RMS: Average RMS, impedance
Low-limit mA) output model] Diaplay method: STND (fixed) Diaplay method: SCAL 01)

AVG 02. Change the setting value as YES by pressing the direction keys.
1-2 value of Min. value of display range 0 - 500 VACᜠ 0.0 to 500.0 5.01 MΩ
A 2 + A22 + ··· + An2 2-9 - 03. Press the [MODE] key to reset all parameter values as default and to return
• True RMS = 1 Display transmission
500V
[DC current & Transmission (DC 4 - 20
FS-L
Measurement n 0 - 250 VACᜠ 0.0 to 250.0 5.01 MΩ
1-3 method: output mA) output model], Decimals Display range to run mode.
250V
method A + A2 + ··· + An 0 - 110 VACᜠ 02) 0.0 to 440.0 1.11 MΩ
IN-T tRMS
• Average RMS =  1 STND, )000 [AC current & Transmission (DC 4 - 20
110P
0 -1999 to 9999
n SCAL mA) output model] 0 - 50 VACᜠ 0.00 to 50.00 1.11 MΩ
× Waveform rate )0 -199.9 to 999.9
50V

Error
Min. value of display range 0 - 20 VACᜠ 0.00 to 20.00 200.92 kΩ
(n = number of display values ​​per cycle, 20V
)00 -19.99 to 99.99
A = display value) Comm. [RS485 Comm. output model] 0 - 10 VACᜠ 0.00 to 10.00 200.92 kΩ
2-10 -
Address 01 to 99 )000 -1.999 to 9.999
ADRS 01 10V
[DC voltage model], [AC voltage model] 1-2 0 - 2 VACᜠ 0.000 to 2.000 20.92 kΩ Error display is released automatically when it is in the measured and display range.
Comm. [RS485 Comm. output model]
2V
0, 0.0, 0.00, 0.000 Display 2-11 - Display Description Troubleshooting
)0
0 - 1 VACᜠ 0.000 to 1.000 20.92 kΩ
speed 38.4k, 19.2k, 9600, 4800, 2400, 1200 bps
BPS 9600 1V
[DC current model], [AC current model] method: Flashes when measurement input is exceeded the
Decimal SCAL [RS485 Comm. output model]
01) C onnect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
0, 0.0, 0.00, 0.000 2-12 Parity bit - range to measure. max. allowable input (110 %) Disconnect power supply
)000
1-4 point
HHHH
NONE, EVEN, ODD
PRTY NONE
When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
DOT
position 1-2 Flashes when measurement input is exceeded the and check the cables.
[AC voltage model], [AC current model] 02)
Display [RS485 Comm. output model] 02) In case of 0 to 110 VACᜠ of AC voltage range and using P.T (potential transformer) for 440 VACᜠ / 110 VACᜠ, if LLLL 01)
2-13 Stop bit - 110 VACᜠ is input, and the unit displays 440 VACᜠ automatically by preset scale value for P.T user’s convenient. min. allowable input (-10 %)
0, 0.0, 0.00, 0.000 method: 2, 1 bit
0 STP 2
Turns ON when display input is exceeded high-limit
FREQ
2-14
Response [RS485 Comm. output model]
- ■ AC current model D-HH
scale setting value or max. display range (9999) Reset within the display
-1999 to 9999 waiting time 5 to 99 sec
RSwT 5
High-limit Display range Input Turns ON when display input is exceeded low-limit range.
1-5 H-SC - • Display value against 1-2 OFF: unlock, Input range
scale 02) impedance scale setting value or min. display range (-1999)
max. measurement input Display Diaplay method: STND (fixed) Diaplay method: SCAL 01)
D-LL
LOC1: lock parameter 1,
method: 2-15 Lock - Turns ON when input frequency is exceeded the
-1999 to 9999 LOC2: lock parameter 1, 2, 0-5A 0.000 to 5.000 0.02 Ω
-
LOC OFF
Low-limit SCAL max. display value of measured range
5A
1-6 L-SC - • Display value against LOC3: lock parameter 0, 1 and 2
F-HH
scale 02) 0 - 2.5 A 0.000 to 2.500 Decimals Display range 0.02 Ω
min. measurement input
@5A
Flashes twice when it exceeds zero range (±99)
■ Parameter 0 group
0-1A 0.000 to 1.000 0 -1999 to 9999 0.10 Ω Reset within the zero range.
1-2 and returns to run mode
1A OVER
Display 0 - 500 mA 0.0 to 500.0 )0 -199.9 to 999.9 0.20 Ω
Display
)5A
01) D
 isplays at DC input model only.
0.100 to 5.000 % method: Parameter Mark Defaults Setting range 0 - 250 mA 0.0 to 250.0 )00 -19.99 to 99.99 0.20 Ω
High-limit STND, condition
)25A
display value 0 - 100 mA 0.0 to 100.0 )000 -1.999 to 9.999 1.02 Ω
1-7 SCAL [DC voltage & Preset setting model]
)1A
gradient 0 - 50 mA 0.00 to 50.00 1.02 Ω
INbH !000
1-2 -5 to 110 % of display range 2-1
correction
50MA
Display [AC voltage & Preset setting model] Output 01) C
 onnect to the input terminals whose 30 % to 100 % of the input range includes the max. value of the input
50)0
0.100 to 9.999 Output high- 0 to 110 % of display range
method: operation range to measure.
0-1 limit output When the max. input value is under the 30 % of the input terminal range, display accuracy is degraded.
FREQ [DC current & Preset setting model] mode:
hSET
setting value
1-2 -5 to 110 % of display range except
Low-limit OFF
Display [AC current & Preset setting model]
%000
display value
1-8 00 -99 to 99 method: 0 to 110 % of display range
deviation
INbL
STND, [DC voltage & Preset setting model]
correction 03)
SCAL -5 to 110 % of display range 2-1
1-2 00)0
[AC voltage & Preset setting model] Output
Exponent of Display Output low- 0 to 110 % of display range
1-9 10-0 10-0: 100, 10-1: 10-1, 10-2: 10-2, 10 1: 101 operation
INB method: 0-2 limit output
mode:
INbE
[DC current & Preset setting model]
lSET
FREQ setting value
-5 to 110 % of display range except
01) Displays at AC voltage or AC current model only.
)000
[AC current & Preset setting model] OFF
02) Scale display range and frequency measurement range are variable according to decimal point position. 0 to 110 % of display range
Dot Scale display range Frequency measurement range
[DC voltage], [AC voltage] 2-1
-1999 to 9999 1 to 9999 Hz
Max. peak value in run mode Output
Display max.
0 )0
-199.9 to 999.9 0.1 to 999.9 Hz 0-3 operation
peak value 01) [DC current], [AC current] mode:
)0 hPEK
-19.99 to 99.99 0.10 to 99.99 Hz
Max. peak value in run mode except
)00
)000
-1.999 to 9.999 0.100 to 9.999 Hz
OFF
)000
03) L ow-limit display value deviation correction range is within -99 to 99 for D0, D-1 digit regardless of decimal point position. [DC voltage], [AC voltage] &
Display min. Min. peak value in run mode 2-4 Peak
)0
0-4 monitoring
peak value 01) [DC current], [AC current]
lPEK
delay time:
Min. peak value in run mode except 00
)000

01) Reset: Press any one of [◀], [▼], [▲] keys.