Safety Device according to DIN EN ISO 5175-1

Safety device with multiple function: SRT


Type SRT for protection of cylinder regulators and tapping points
The safety device SRT according to DIN EN ISO 5175-1:
• avoids dangerous gas mixtures by a gas non-return valve (NV)
• stops flashback through flame arrestor (FA)
• a temperature-sensitive cut-off valve stops the gas flow when
a predetermined temperature is exceeded (TV)
• a dust filter protects the gas non-return valve against contamination
• every safety device is 100% tested
• all metal components in brass 2.0401 / spring 1.4310
Safety elements of the IBEDA safety device SRT:
• NV Gas non-return valve
• FA Flame arrestor
• TV Temperature-sensitive cut-off valve
Additional features:
• DF Dust filter

Maintenance:
The safety devices are to be tested by a qualified and authorised person at regular intervals according to country specific
regulations. The safety device is to be tested for gas tightness, gas flow and gas return at least once a year.
We would be pleased to offer you the flashback arrestor testing unit model PVGD.
It is not allowed to open the safety devices.

Technical Data:
Natural Gas
Hydrogen (H) Compressed
Gas types: Acetylene (A) (Methane) (M) Oxygen (O) (D)
Industrial gas (C) Air
Propane (P)
0,15 MPa 0,35 MPa 0,50 MPa 2,5 MPa 2,5 MPa
Working pressure:
1,5 bar 3,5 bar 5,0 bar 25 bar 25 bar
Cracking pressure: 50 to 70 mbar position-independent
Gas temperature: -20°C up to +70°C ( Oxygen -20°C up to +60°C)
Ambient
-20°C up to +70°C
temperature:
G1/4RH
Threads: G3/8LH
G3/8RH
M16x1,5LH
EN 560 M16x1,5RH
UNF9/16-18LH
ISO / TR 28821 UNF9/16-18RH
UNF5/8-18LH
UNF5/8-18RH
Measure and weight: diameter: length: weight:
21,0 mm 60,0 mm 95,0 g
Applications:
Process: welding cutting heating

up to 30 mm up to 200 mm up to 30 mm
Other materials, surface finishing, gas types and additional connections available on request.
The flashback arrestor meets the test criteria of the Australian standard AS4603:1999
The working pressures approved by the UL are different to what is stated above.
Further information in this regard can be provided on request
EN/03/18/00

IBEDA Sicherheitsgeräte und Gastechnik GmbH & Co. KG ● Bahnhofstr. 27 ● 53577 Neustadt (Wied)
Tel. +49 (0)2683.306-0 ● Fax +49 (0)2683.306-31 ● www.ibeda.com ● info@ibeda.de
Safety Device according to DIN EN ISO 5175-1

Type: SRT

Flow rates [air]:


pv = Primary pressure
ph = Secondary pressure
∆p = Primary pressure minus Secondary pressure

Conversion Factors:
0,1 MPa = 1 bar = 100 kpa = 14,504 psi
3
1 m /h = 35,31 cu ft/h

A H P M M O E L
QG ► C2H2 H2 C3H8 CH4+C CH4 O2 C2H4 C3H6

F 1,2 3,8* 0,90 1,25 1,4 0,95 1,02 0,92

* Conversion factor 2.5 for devices comprising a flame arrestor


The conversion factor for free flow is 3.8.
(Reference: BAM report 220, D. Lietze)

Example:

QG = QD x F
QG ► A = 6,4 x 1,2 = 7,68 m³/h C2H2
QG = flow / gas type
F = conversion factor
QD = flow / air

Certification / Technical Standards / Rules


BAM Federal Institute for Materials Research and Testing,
UL Underwriters Laboratories Inc., DGUV employer´s liability
insurance association rules and regulations, DVS German
Association for Welding, Cutting and Allied Processes, TRBS
German Technical rules for operation safety.
Standards/ Approvals
Company certified according to
ISO 9001:2015 and ISO 14001:2015,
CE-marking according to: Pressure Equipment Directive
2014/68/EU

(Subject to change without notice)


EN/03/18/00

IBEDA Sicherheitsgeräte und Gastechnik GmbH & Co. KG ● Bahnhofstr. 27 ● 53577 Neustadt (Wied)
Tel. +49 (0)2683.306-0 ● Fax +49 (0)2683.306-31 ● www.ibeda.com ● info@ibeda.de

You might also like