You are on page 1of 1

RECESSED ACCESS BOX

DUCTILE IRON FRAME ALUMINUM SLOT RISER


RECESSED ACCESS BOX & GRATE W/ GALVANIZED GRATING
SLOT DRAIN W/
CORRUGATED HDPE PIPE DUCTILE IRON FRAME
& GRATE ALUMINUM SLOT RISER
W/ GALVANIZED GRATING 0.30M OFFSET
VARIABLE INVERT ALUMINUM SLOT RISER
ELEVATIONS (ACCORDING TO
PLANS) W/ GALVANIZED GRATING
2.5" (65MM)
VARIABLE HEIGHT 300mm PORTLAND CEMENT OPENING WIDTH
CONCRETE PAVEMENT
200mm BASE COURSE
270mm SUBBASE COURSE
CORRUGATED HDPE PIPE
0.45M
CONCRETE
SECTION A-A'
A A' ND
300mm PORTLAND CEMENT
HDPE PIPE TO RECESSED ACCESS CONCRETE PAVEMENT
BOX CONNECTION 200mm BASE COURSE
270mm SUBBASE
COURSE
CORRUGATED
HDPE PIPE
COMPACTED
6"(150MM) MIN. COMPACTED FILLING
GRANULAR BEDDING
1 HDPE PIPE TO RECESSED ACCESS BOX CONNECTION
CONCRETE COVER EMBANKMENT MATERIAL

S-3 SCALE NTS SLOT DRAIN CROSS SECTION

2 SLOT DRAIN DETAILS


S-3 SCALE NTS

IRON FRAME & GRATE


1 - EXTG. MANHOLE GRATES/SOLID COVER SHALL BE DUCTILE IRON PER ASTM A153/AASHTO M 232 for superior
CORROSION PROTECTION.
2 - EXTG. MANHOLE FRAMES SHALL BE DUCTILE IRON PER ASTM A536 GRADE 70-50-05.
IRON FRAME & GRATE 3 - SLOT HEIGHT VARIES DEPENDING ON DESIGN CRITERIA.
4 - 4'' - 10'' (100 TO 250 MM) PIPE SHALL MEET AASHTO M252
300mm PORTLAND CEMENT
FINISH GRADE (PCCP/ACP)
5 - 12'' - 36'' (300 TO 900 MM) PIPE SHALL MEET AASHTO M294
CONCRETE PAVEMENT EXTG. MANHOLE
ACCORDING TO PLAN 6 - DRAINAGE CONNECTION STUB JOINT TIGHTNESS SHALL CONFORM TO ASTM D3212
200mm BASE COURSE
FOR CORRUGATED HDPE.
CORRUGATED HDPE PIPE 7 - STANDARD GRATES SHALL MEET CLASS D–TEST LOAD 210KN
VARIABLE INVERT EXTG. MANHOLE (ACCORDING TO PLANS)
ELEVATIONS AVAILABLE VARIABLE INVERT HEIGHTS ONLY; CONCRETE COLLAR IS NEEDED.
(ACCORDING TO AVAILABLE (ACCORDING TO 8 - RECOMMENDED TO INSTALL A RECESSED ACCESS BOX OUTLET EVERY 40M TO ENSURE
PLANS) PLANS) EXTG. RCPC (ACCORDING TO PLANS) THE CLEANING OF THE DRAIN IS POSSIBLE.
9 - MINIMUM OF 150MM BEDDING LAYER OF GRANULAR BACKFILL MATERIAL SHALL BE PLACED AND
ACCORDING TO
AS BUILT PLAN COMPACTED AT THE BOTTOM OF THE CORRUGATED HDPE PIPE.
COMPACTED FILLING 10 - MINIMUM COMPRESSIVE STRENGTH OF CONCRETE ENCASING CORRUGATED HDPE PIPE AFTER 28 DAYS
EMBANKMENT MATERIAL SHALL BE 24MPA (3500PSI)
RCPC DIA.
COMPACTED FILLING 11 - MINIMUM COMPRESSIVE STRENGTH OF CONCRETE FOR RECESSED ACCESS BOX AFTER 28 DAYS
EMBANKMENT MATERIAL SHALL BE 24MPA (3500PSI)
12 - DIMENSIONS ARE FOR REFERENCE ONLY. ACTUAL DIMENSIONS MAY
VARY.

HDPE PIPE TO EXTG. CATCH BASIN CONNECTION

EXISTING CATCH BASIN WITH IRON FRAME & GRATE 4 NOTES & SPECIFICATIONS
S-3 SCALE NTS

3 HDPE PIPE TO EXTG. CATCH BASIN CONNECTION


S-3 SCALE NTS

DESIGNED BY: PROJECT TITLE: REVISIONS SHEET CONTENT: DRAWING NO.


SMC INFRASTRUCTURE REV. DATE DESCRIPTION
DETAILED ENGINEERING DESIGN
S-3
DESIGN SCIENCE STAR WIDENING
INCORPORATED SLOT DRAIN PLAN & DETAIL
SMC STAR TOLLWAYS INC. (STA 60+000 TO 98+860) SHEET NO. SCALE

ELROY LIAM S. TABAYAAY ABDULLAH N. MAMBUAY


AUTHORIZED REPRESENTATIVE
3 OF 4 NTS
SR. UTILITY ENGINEER PROJECT DIRECTOR LOCATION: BATANGAS