You are on page 1of 2

VP2 User Manual 2.

App Download and Installation


◆Search the "VP2" application in the APP market, download and
1. Appearance of Main Unit install the App.
◆If Android is in use, scan the QR code below to download and
Take the main unit VP2 (with convex probe C) as an example, the appearance is as follows: install the App.
3. Charging the Probe
◆Connect the probe (device) and the charger through the configured charging cable, and
Immersion/ Soak boundary
the battery can be charged in the shutdown state.
◆When the battery is charging, the indicator of the probe (device) is blue. If the battery is
fully charged, the indicator turns off.
4. Turning on/off the Probe
Soak section

Probe head
◆Turning on: Press and hold the power button for 3 seconds, and the power indicator will
turn purple.
◆Shutdown: In the power-on state, press and hold the power button for 3 seconds, and
the system will automatically shut down.
◆Auto shutdown: The probe will automatically shut down if no connection is available for
over 15 minutes after power-on.
5. Probe connections: Wi-Fi and USB (taking Android as an example)
Power display button ◆ Wi-Fi connection: Tap the probe displayed in the Wi-Fi list, and the App will
automatically connect the probe. When connecting the probe via Wi-Fi for the first time,
Charging and USB please scan the QR code label at the bottom of the probe (see the figure below) for
Wi-Fi antenna communication port pairing according to the App prompt.

Fan inlet Power button

◆USB connection: Make sure the probe is in power-off state. Then connect the probe
Freeze button Indicator device to a tablet or mobile phone via the configured USB cable, and finally turn on the
power of the probe. The system pops up a prompt "Allow the app VP2 to Access to the
USB device?" Tap "OK" and then tap the App "wired mode" icon to finish the connection.
 The iOS system supports Wi-Fi connection to the probe only, which can be
connected via scanning the QR code label at the bottom of the probe.
Probe protective cover
 To change the connection to the device from USB to Wi-Fi, the probe must be
turned off first.

Optional probe list File Image Name of Probe


New file information area institution status Date

Exit

Parameter
display
File Function area
Optional probe list list setting Exit Switch
User to another probe
application exam part
area
Operation tip

Patient report
File list

Brightness
Parameter
menu
button

Full screen
Freeze Depth scale

Ultrasound imaging interface on the tablet


QR code scanning
QR code scanning File list
Switch to
Tablet connection interface Mobile phone connection interface File another
function probe Probe
key exam part status Date
The Wi-Fi connection status of the probe is described in the table below:
Pop-up
function
menu
Parameter
Online Description Pairing Description display
Depth area
scale

The connected probe Paired probe User


application
area

Pop up or
Image
The searchable probe Unpaired probe hide the area
setting
parameter
menu
button
The probe is paired but

not searched out

6. Ultrasound Imaging Interface

After connecting the probe, select the exam part, and the system will automatically enter
the ultrasound imaging interface.
Meas&Calc Return Freeze Save Save
to B cine image
mode
Ultrasound imaging interface on the mobile phone
7. Switching Mode Soome imaging param meters in B, M, CFM
M /CPA or PW mod
de can be adjusted
d through
On th
he tablet, tap the Mo
ode button on the App
A interface to swiitch the mode. the gestures below.
On th
he mobile phone, usse gesture to swipee up, down, left or right
r in the image area of the  wipe up or down with one finger in the image
On the tablet, sw
screen to switch the imaging mode. area in B/CFM/C CPA mode.
Depth
◆In B mode, swipe left to switch to CFM mode.
m  On the mobile ph old the image area till the
hone, press and ho
◆In CFM
C mode, swipe right
r to switch to B mode. phone vibrates, sswipe up or down with one finger to adjust
◆In CFM
C mode, swipe left
l to switch to PW
W mode. the image depth.
◆In PW ght to switch to CFM mode.
P mode, swipe rig
 On the tablet, sw
wipe left or right with
h one finger in the image
◆In CFM
C mode, swipe up
u to switch to CPA
A mode. area in B/CFM/CPA mode, PW imag ge area in PW mode or M
Gain
◆In CPA
C mode, swipe down
d to switch to CFM
C mode. image area in M mode.
◆In B mode, swipe up to
t switch to M mode
e.  On the mobile phhone, press and ho old the image area till the
◆In M mode, swipe dow
wn to switch to B mode. phone vibrates, sswipe left or right with one finger to adjust
The relationship
r en switching modes on the mobile phone is as follows:
betwee the gain.
Grayscale
G
In B mode, adjust PRF
F by swiping up or down with one fing
ger on
the grayscale map.

C-PRF
In CFM/CPA
C mode, addjust PRF by swiping up or down witth one
finger on the color map
p.

Zoom
In B/CFM/CPA
B mode, zoom in or out the image area by usin
ng two
fingers.

B CFM
M PW In th
he PW image area in PW mode, adjus st PRF by swiping the
t left
PW
W baseline
speeed scale up or dow
wn with one finger; adjust
a the PW baselline by
M CPA
A swipping the image areaa (except for the lefft speed scale area
a)up or
dowwn with one finger.
PW
W correction
angle In PW
P mode, swipe left or right with one finger in the CFM image
area
a to adjust the corre
ection angle.

TGC
In B mode live state, swipe left with one finger on the right edge of
the screen to bring up the TGC gain adjus stment frame.
8. Parrameter Adjustm
ment
Adju
usting parameters can
c only be operatted in live state. Op
pen the parameter menu by 9. Liist of Parameterrs
tapp
ping the button Advance Parameters on
o the tablet, or by tapping
t button in
n the user Im
maging parameterss for different imaging modes are as fo
ollows.
appllication area on the
e mobile phone.

List of Ima
aging Parameters be
b identified, or the failure cannot be re
esolved after trying the solutions below
w, please
contact
c SIUI servicee. DO NOT disasse emble the device without the instruction of SIUI
Imaging Mode
M arameter
Imaging Pa
service
s staff, so as to
t avoid any damag ge due to wrong operation.
TG
GC,
Depth, Failure Causes and solutions
B (B
( gain), Thee LED indicattor is
FR
RQ (frequency), Low baattery. You may turn off the device upon
shing, and the device
flas
DY
YN (dynamic range)), recharge.
B/2B
B cannnot be turned off.
SR
R (softening),
GS
SC (gray scale), If the LLED indicator of thhe probe is purple e, the
PE
ER (persistence), battery may be low and ne eeds recharge.
FR
R (frame rate), If the LE
ED indicator of the probe is white, rese
et the
TH
HI (harmonics) power o of the probe and reconnect Wi-Fi fo or the
probe.
M Ga
ain, Wi-Fi connection of the probe fails and the
If the W
Sw
weep Sd (sweep speed) Unable to connect to Wi-Fi.
W messag ge prompts "Som mething went wrong.
w
Depth, Unable to select device.””, please return to o the
C (C
( gain), tablet/m
mobile desktop, tap p "Settings", and seearch
PR
RF (Pulse Repetition
n Frequency), for the ""probe signal" that failed to connect to
t the
CFM/C
CPA FR
RQ (frequency), WLAN, tap and hold, se elect "Do not save e the
Priiority, networkk" or "Forget netwo ork" in the pop-up menu,
m
WFF (wall filter), return to
o the App to reconnnect.
Ste
eer
The
e App is open but images Restart the probe, restart the App, and reconnect
FR
RQ (frequency), can
nnot be displayed. the prob
be to Wi-Fi.
Ga
ain,
The e App has enterred the
Co
orr A (correction ang
gle),
ultrrasound imaging intterface,
PW
W SV
V (sampling volume)), Disconnnect the Wi-Fi co onnection, uninstalll the
butt immediately jumpss to the
PR
RF (Pulse Repetitionn Frequency), current A
App, install and ope
en the App again.
Wi--Fi connection se election
Base (baseline), pag ge.
D Inv (up and down inversion)
UD If the product is place ed in a
high static prressure This is normal. Without
W basic s
safety
10. List of Indicatorr status env vironment for a lon
ng time, consideerations, it will not afffect normal operation or
List of Indicator status thee screen may briefly interfere
e with diagnosis. Please
P set up the device
d
display an unclear white in an ennvironment without high static pressure e.
Color of indicator s
Status imaage.
Wh
hite Wi-Fi conne
ected
Purrple Probe is re
eady
Blu
ue Shutdown and charging Shanttou Institute of Ultra
asonic Instruments Co., Ltd. (SIUI)
Tel: +86-754-88250150
O
Off Sh
hutdown or charging complete
Fax: +86-754-88603664
+
11. Frrequently Asked
d Questions E-mail: siui@siui.com
Webs site: http://www.siui@
@.com
Forr the failure descrip
ptions, possible cau
uses and solutions (see the table belo ow), users
Add: 77 Jinsha Road, Sh hantou 515041, Guuangdong, China
can
n refer to the solutio
ons provided for tro
oubleshooting. If the
e cause of the failurre cannot