You are on page 1of 1

KSK AND PARTNERS SDN BHD

Item Description Unit Quantity Rate Amount

ELEMENT NO. 4 : ROOF AND RAINWATER DOWNPIPES

CAST IN-SITU ROOF CONSTRUCTION

Vibrated reinforced concrete Grade C30/37, generally to:-

A 150mm Thick flat roof slab; laid to fall m3 247 -

Various diameter steel bar reinforcement as described in :-

B 150mm Thick flat roof slab; laid to fall kg 29,640 -

Steel fabric reinforcement as described in :-

C Mesh fabric reinforcement, A7 weighing 3.02kg/m2 m2 3,294 -

Formwork as described:-

D To soffit of flat roof slab m2 1,647 -

E To edge of flat roof slab m 445 -

F Extra over for forming 300mm x 50mm scupper drain m 445 -

Prepare and apply approved waterproofing system as described

G To roof slab m2 1,647 -

H To 300mm x 50mm deep scupper drain m 445 -

Supply and lay cement and sand (1:3) protective screed space with
fibre mesh laid to fall:-

J To flat roof m2 1,647 -

50mm thick extruded polystrene board as insulator to RC Flat roof,


as per manufacturer's instruction and specification

K To roof slab m2 1,647 -

Testing
L Allow for providing all necessary equipments, plants, tools and Item 5,000.00
other ancillary materials needed to perform leakage test on the
floor and subsequent removal of the same from the site

5,000.00