You are on page 1of 4

KSK AND PARTNERS SDN BHD SECTION 2A : EMERGENCY DEPARTMENT AND UNIT HASIL

Item Description Unit Qty Rate (RM) Amount (RM)

ELEMENT NO. 3 : ROOF

FLAT ROOF

Vibrated reinforced concrete Grade C30/37 as described in :-

A Flat roof; 300mm thick m3 243

B Parapet wall; 1500mm high m3 96

Steel bar reinforcement as described :-

C Various diameter in flat roof kg 29,160

D Various diameter in parapet wall kg 19,200

Steel fabric reinforcement to B.S 4483 or B.S 1221A as


described;-

E In flat roof m2 1,698

Sawn formwork as described :-

F To sides and soffit of flat roof m2 1,019

G To sides of parapet wall m2 650

H EXTRA OVER for forming 350mm wide x 300mm depth m 136


perimeter gutter

J EXTRA OVER for forming 300mm wide x 200mm depth m 136


scupper drain

Prepare and apply approved waterproofing system or other


equivalent to horizontal and vertical areas all accordance to
manufacturer's instruction

K To flat roof m2 849

Cement and sand screeding (1:3) as described:-

l To flat roof m2 849

50mm thick extruded polystyrene board as insulator to RC


flat roof all as per manufacturer's specification

L To flat roof m 849

PONDING TEST

M Allow for ponding test as descibed to roof slab Item

To collection RM -

NAIKTARAF JABATAN PERUBATAN KECEMASAN


3/1 BINA)
HOSPITAL CANSELOR TUANKU MUHRIZ, PPUKM (REKA DAN
KSK AND PARTNERS SDN BHD SECTION 2A : EMERGENCY DEPARTMENT AND UNIT HASIL

Item Description Unit Qty Rate (RM) Amount (RM)

ELEMENT NO. 3 : ROOF (CONT'D)

ROOF STRUCTURE

Proprietary Steel Roof Trusses

Design, supply, fabricated and delivery to site including


fixing and hoisting in position, lightweight high tensile roof
trusses system in mild steel sections complete with rafters,
bearers, ties, struts, steel structural roof members for the
complete installation as described

A Generally to roof (approximate area = 3130m2) Item

ROOF COVERING

Approved equivalent metal deck roof covering laid to slope


and fixed on steel roof trusses (steel roof trusses measure
seperately), including all necessary accessories all in
accordance with manufacturer's instruction and to the
Architect's approval

B Laid to slope m2 3,130 -

C Approved mineral fibre insulation as described m2 3,130 -

D Approved double sided aluminium insulation foil as m2 3,130 -


described

E Approved chicken wire mesh as described m2 3,130 -

Flashing

F Aluminium flashing bend to shape including approved m 226 -


sealant and any support all as per Architect drawing

To collection RM -

NAIKTARAF JABATAN PERUBATAN KECEMASAN


3/2 BINA)
HOSPITAL CANSELOR TUANKU MUHRIZ, PPUKM (REKA DAN
KSK AND PARTNERS SDN BHD SECTION 2A : EMERGENCY DEPARTMENT AND UNIT HASIL

Item Description Unit Qty Rate (RM) Amount (RM)

RAINWATER DOWN PIPE

A 150mm diameter uPVC pipes; encased to brickwall and m 72


column

B EXTRA OVER 150mm diameter downspout no 20

C EXTRA OVER 150mm diameter bend no 20

D EXTRA OVER 150mm diameter swan neck no 20

E EXTRA OVER 150mm diameter outlet no 20

F EXTRA OVER for shoe no 20

G 150mm diameter dome-headed uPVC grating and frame no 20


set

H EXTRA OVER labour and material for connecting end of no 20


150mm diameter rain water down pipe to side of precast
concrete drain including breaking the floor and side and
making good existing and cement and sand (1:3) grouting

TESTING

J Allow for testing the Rainwater Drainage System Item

To collection RM -

NAIKTARAF JABATAN PERUBATAN KECEMASAN


3/3 BINA)
HOSPITAL CANSELOR TUANKU MUHRIZ, PPUKM (REKA DAN
KSK AND PARTNERS SDN BHD SECTION 2A : EMERGENCY DEPARTMENT AND UNIT HASIL

Item Description Unit Qty Rate (RM) Amount (RM)

ELEMENT NO. 3 : ROOF (CONT'D)

COLLECTION PAGE ;

Page 3/1 -

Page 3/2 -

Page 3/3 -

ELEMENT NO. 3 : ROOF


RM -
(Carried to Summary)

NAIKTARAF JABATAN PERUBATAN KECEMASAN


3/4 BINA)
HOSPITAL CANSELOR TUANKU MUHRIZ, PPUKM (REKA DAN