Professional Documents
Culture Documents
Wo TGL 07 Maret 2024
Wo TGL 07 Maret 2024
004/FRM
DAILY ACTIVITY REPORT Rev : 00
Distrik : BDMA - PIT LANGAP Halaman : .../....
Tanggal : 07 Maret 2024
03-Jan
No EGI C/N HM Date In Time In No WO Status Root Cause of Trouble Today/ Activities Status Unit
SCH SERVICE 2000 HM. MINOR REPAIR; WASHING RADIATOR ; GENERAL REPAIR UNIT (REPLACE
CONTROL VALVE DLL) ,CHECK INSPECTION HOLE WATERPUMP,CHECK TEMPATURE ALL CYLINDER
ATTACHMENT,CHECK BATTERY HEALTH,DRAIN OIL HYDRAULIC,DRAIN COOLANT,REMOVE FAN MOTOR
4 PC1250SP-8R EX2012 40072 4-Mar-24 7.00 45051 SC 9175 : 2000 Hr Service ZAINAL, FATUR CONTINUE 7-Mar-24 7.00
ASS’Y,REMOVE FAN MOTOR FROM BRAKET,CLEANING,REPLACE & INSTALL FAN MOTOR TO
BRACKET,DISCONECT ALL HOSE & PIPPING CONTROLL VALVE 1,2,3,REMOVE CONTROL VALVE
NO.2,CLEANING ALL COVER,CLEANING TOOL AND WORK AREA
8 PC400LCSE8 EX409 0 6-Mar-24 7.00 45161 SC Air Conditioner Abnormal SCH.REPLACE COMPRESOR AC, REPAIR WIRING AC ILHAM, MAJID, HASIM, AGUNG, HERI, ALFIAN RFU 7-Mar-24 10.32
19 D375A-5 DZ3007 0 7-Mar-24 11.44 BD061431 US Abnormality in Optional Accessories REPLACE BLOWER AC WELLY, DEVA, ALPIN, LUKI, BARHAKI, HAKIM, SEPTYAN. RISKI RFU 7-Mar-24 16.10
21 PC400LCSE8 EX409 0 7-Mar-24 13.13 BD061434 US Attachment Part lost / loosen FABRIKASI LOCK PIN LINK H WELLY, DEVA, ALPIN, LUKI, BARHAKI, HAKIM, SEPTYAN. RISKI RFU 7-Mar-24 13.58
26 D375A-5 DZ3014 0 7-Mar-24 16.29 BD061435 US Abnormality in Optional Accessories CHARGING AC SOFYAN, IRFAN, MAHFUD RFU 7-Mar-24 16.40