BRIDGE
2 NORTH Finish wire Positions 4 and 6 provide 'parallel' wired Neck and Bridge
NECK
humbuckers and; position 5 provides Neck and Bridge single coils
3 SOUTH Finish wire in parallel. All positions are hum-cancelling.
S N N S Vol/Tone controls work as normal in positions 1-3, Neck Vol/Tone
4 SOUTH Start wire controls positions 4 & 5, Bridge Vol/Tone controls position 6.
The pickup colour coding shown in this diagram does not represent
Grd To Bridge any particular pickup manufacturer - please follow key.
4
3
2
Any solder points 1 Parallel Neck
shown in between
pads are meant to
abridge both pads c
Vol Tone S N N S S N N S
(Bridge) (Bridge) 4 1
5 2
(SHIELD)
In Parallel 6 3 In Series
4
3
2
1
Multi-Core
Screened Cable c (Tip)
S N N S S N N S
Parallel Bridge
Model No:-
3X3-05 Free-Way Ultra HH Parallel Scheme 2V/2T
REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.
Notes:-
BRIDGE
NECK Active Module is assumed to be a pre-amp, booster, overdrive or
EQ and is brought into the signal path in positions 4-6, and out
of the signal path in positions 1-3. Follow specific Active Module
instructions for correct install (dotted lines here are indication only).
Ground
Hot
Any solder points
shown in between
pads are meant to + Active Neck
abridge both pads
Vol
(Bridge)
Active 4 1
Module BATTERY
Ground 5 2
+ Active 6 3 Bridge+Neck
Hot + -
Output
GRD
Input
+ve
Multi-Core
Screened Cable
(Tip)
Stereo
Model No:-
3X3-05 Free-Way Ultra HH Active Module 2V/2T
REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.
BRIDGE
2 NORTH Finish wire Position 5 provides Neck and Bridge Single Coils (in phase).
NECK
Position 6 provides Neck and Bridge Single Coils (out of phase).
3 SOUTH Finish wire
S N N S
4 SOUTH Start wire
The pickup colour coding shown in this diagram does not represent
Grd To Bridge any particular pickup manufacturer - please follow key.
4
3
2
Any solder points 1 Neck
shown in between
pads are meant to
abridge both pads c
Vol Solder & tape Tone S N N S S N N S
Model No:-
3X3-05 Free-Way Ultra HH Single Coil Options 2V/2T
REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.
Notes:-
BRIDGE
NECK
Positions 1, 2 & 3 are standard neck/both/bridge pickup settings,
positions 4, 5 & 6 offer Series, Series-O/O/P & Parallel O/O/P
combinations of both pickups.
Note, pickups with metal baseplate/cover must have separate shield wires.
Master Volume works in all switch positions. Bridge Volume works
in pos. 3 or adjusts the mix of Bridge Pickup in pos. 2, 4, 5 & 6.
The pickup colour coding shown in this diagram does not represent
Grd To Bridge any particular pickup manufacturer - please follow designations.
Vol Tone
(Master) (Neck) FRONT VIEW OF PICKUPS AND SWITCH
(SHIELD)
Ground
Hot
c
Any solder points
shown in between In Series / In Phase Neck
pads are meant to
Note Vertical Orientation! abridge both pads Solder & tape
4 1
(SHIELD)
5 2
Ground
In Series / Out Phase 6 3 Bridge+Neck
Hot
Vol Tone
(Bridge) c (Bridge)
(Sleeve)
Multi-Core
Screened Cable
Parallel / Out Phase Bridge
Model No:-
3X3-05 Free-Way Ultra SS Phase Scheme 2V/2T
REVERSE VIEW OF PICKUPS, SWITCH AND POTENTIOMETERS.
BRIDGE
NECK 1 NORTH Start wire
2 NORTH Finish wire
3 SOUTH Finish wire
Master Volume works in all switch positions. Bridge Volume works
4 SOUTH Start wire in pos. 3 or adjusts the mix of Bridge Pickup in pos. 2, 4, 5 & 6.
The pickup colour coding shown in this diagram does not represent
Grd To Bridge any particular pickup manufacturer - please follow key.
Vol Tone
(Master) (Neck) FRONT VIEW OF PICKUPS AND SWITCH
(SHIELD)
4
3
2
1 c
Any solder points
shown in between In Series / In Phase Single Coils
pads are meant to Solder & tape (Hum-Cancelling)
abridge both pads Link wires
Note Vertical Orientation!
Vol Tone
(Bridge) (Bridge) 4 1
(SHIELD)
4 5 2
3
2
In Series / Out Phase 6 3 Bridge+Neck
1
c
(Sleeve)
Multi-Core
Screened Cable
Parallel / Out Phase Bridge
Model No:-
3X3-05 Free-Way Ultra HH Phase Scheme 2V/2T