TECHNICAL REPORT
King Abdullah International Gardens
KSA
TABLE OF CONTENTS
1. Introduction ................................................................................................................................................. 2
1.1. Project: King Abdullah International Gardens ................................................................................... 2
1.2. Customer ........................................................................................................................................... 2
1.3. Basic assumptions ............................................................................................................................. 3
2. Standards, reports, and design criteria ...................................................................................................... 4
2.1. States of design ................................................................................................................................. 4
2.2. Reference codes and standards ........................................................................................................ 4
2.3. General notes about calculations ...................................................................................................... 4
2.4. Units ................................................................................................................................................... 4
2.5. Software ............................................................................................................................................. 5
3. Product information .................................................................................................................................... 6
3.1. Used Hilti portfolio.............................................................................................................................. 6
3.2. Installation products ........................................................................................................................... 6
3.3. Anchors .............................................................................................................................................. 6
3.4. Product assumptions ......................................................................................................................... 6
4. Design input from the customer ................................................................................................................. 7
4.1. Input documents from the customer .................................................................................................. 7
4.2. Assumptions from Hilti ....................................................................................................................... 7
4.3. Loads ................................................................................................................................................. 7
4.3.1. Seismic Loads ............................................................................................................................... 8
4.3.2. Wind/Snow/Sand Loads ................................................................................................................ 8
4.3.3. Load cases .................................................................................................................................... 8
5. Summary of calculations ............................................................................................................................ 9
6. Design solutions and verifications ............................................................................................................ 10
7. Special Terms and Conditions of HILTI (“Hilti”) for Technical advice ..................................................... 14
8. Appendices ............................................................................................................................................... 16
8.1. Appendix 01 – Engineering Input Checklist/ Client Input ................................................................ 16
8.2. Appendix 02 – PROFIS Design reports ........................................................................................... 19
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
1. Introduction
The Scope of this document is to provide proof of the structural integrity of designed supports according to the
Agreed Framework. It is important to notice that not all individual supports are calculated, but calculations are
done according to a common agreement.
This document was done according to the relevant regulations and approvals stated later in the document.
Chapter 7. “Appendices” forms an integral part of this documentation as amended from time to time as
indicated by the revision status in this document.
1.1. Project:
Systems under the scope of Hilti design is piping supports including fixpoints for the green clouded lines
below.
1.2. Customer
Name: Zaid Al Hussain Group
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
Hilti provides technical advice on their products, but load inputs and calculations should be verified and
checked by the customer project designer. It is also assumed that guidance in Instruction For Use is kept for
all products mentioned in present document and there is no need for capacity reduction from abnormal use of
products.
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
2.4. Units
The S.I (system international) metric system was used. The following table shows the unit associated with the
items of major interest for structural analysis purposes.
Item Unit
Length mm
Angles o (degree)
Forces kN
Moments kNm
Distributed Load kN/m
Masses kg
Member stress N/mm2 (MPa)
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
Pressure Pa
Fig 2: Units
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
3. Product information
The values used in these calculations are based on the following documentation provided by Hilti.
Hilti has developed Internal Guidelines for definition essential characteristics and evaluation of the
performance of its Installation Products. Technical data has been provided from testing, analytical calculations
or finite element analysis or combination of these.
All used products are manufactured under a qualified Quality Management System in according with the
requirements of ISO 9001 and ISO 14001 standard. Hilti is taking full responsibility for its product quality from
development to end of the lifecycle.
3.3. Anchors
For all those anchors holding a European Technical Assessment (ETA) the technical data used in this report
is based and in accordance with the information given in the respective ETA. Additional Hilti technical data,
supplementing the ETA technical data, may be available, in which case, it will be clearly noted in calculation
reports.
For all those anchors not holding an ETA, the technical data used in this report is based on numerous tests
and evaluation criteria according to the current state-of-the-art and/or the relevant European applicable
regulations for the assessment of fasteners, which is the basis for obtaining an ETA.
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
4.3. Loads
Load actions are classified in EC1990 by their variation in time as permanent actions (G), variable actions (Q)
and accidental actions (A). For simplicity, we refer to all variable loads as Live loads and permanent loads as
Dead loads. For live loads, we use a partial safety factor of 1,5 for ULS. For dead loads, we use a partial safety
factor 1,35. For SLS safety factor is 1,0 for both load cases.
Pipes and ducts represent elements for which variations in time are considered as negligible by EN1990
definitions. Based on that, loads from pipes and ducts are assumed to be dead loads.
Technical report
KSA
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
5. Summary of calculations
The structural integrity for each one of the support solutions listed in Fig 4 has been checked. Calculations
have been done in PROFIS Installation, unless specified otherwise.
The calculations show that these solutions meet all requirements as specified by the customer, as well as the
relevant standards and regulations. Therefore, it can be stated that these solutions are safe for use.
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
Support Types
Ref. Examples of Typical Solutions
Goal Post
Support
Types
Goal Post
Support
Types
Goal Post
Support
Types
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
FixPoint
Support
Types
FixPoint
Support
Types
FixPoint
Support
Types
FixPoint
Support
Types
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
6.2. Detailed structural calculations/ Technical results verifications
Tables below indicates applied loads and cases for support design on project
Fixpoint
Wind Load Distance to Support Total Support Fixpoint
Case No Inside Trench B.O.P. F.F.L. Pipes Design
Existment Base Spc Length Quantity Quantity
Type
KSA
MP-UB 273
Sch40 Steel 150.00 168.30 51.00 46.80 2.25 4.00 53.05 0.20 3.00 1.59 3.18 0.04 0.66 0.32 270.30 7.42 43%
10" M12 OC
MP-UB 324
Sch40 Steel 200.00 219.10 51.00 74.60 2.77 4.00 81.37 0.20 3.00 2.44 4.88 0.05 0.78 0.49 321.10 7.42 66%
12" M12 OC
NOTE : FOR FIXPOINT DESIGN TYPE B; PIPES NEED TO BE ADJUSTED TO A REASONABLE HEIGHT OR ADDITIONAL STRUCTURAL MEMBERS NEED TO BE
PROVIDED FOR FIXPOINT CONNECTIONS SINCE THE DISTANCE IS TOO HEIGHT FOR A FIXPOINT DESIGN.
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
7. Special Terms and Conditions of HILTI (“Hilti”) for Technical advice
1. These terms and conditions apply to the technical advice provided by Hilti to its customers
("Customer"), when Customers seek for certain Hilti's products. These terms and conditions also apply to
future instances of technical advice provided by Hilti to Customer, without the Customer having to be inform
about these terms and conditions in each individual case. Customer's general terms and conditions shall not
apply, even when Hilti has not expressly objected them.
2. Hilti generally provides the technical advice based on technical and legal provisions applicable at Hilti’s
place of establishment.
3. It is the Customer's responsibility to inform Hilti of all project or object related marginal conditions
relevant for Hilti's technical advice, and to check that the technical assumptions by Hilti are correct and
complete and immediately inform Hilti of any misalignments in text form. Hilti is not obliged to verify or check
the project and/or object related framework conditions reported by the Customer (e.g. to ensure compliance
with the actual on-site conditions, legal requirements or plausibility). This also applies when Hilti has inspected
or had access to an object, design documents, or similar technical information on the project or object. Object
or project related framework conditions shall be deemed to be the basis for Hilti's technical advice only when
Hilti has expressly confirmed this; for example, through the reproduction of, or reference to, documents
provided by Hilti in the technical consultation or separate written confirmation. It is the Customer's responsibility
to arrange and pay for the technical advice provided by Hilti.
4. The output is prepared based on the technical information that the Customer provides to Hilti, for Hilti
to provide a non-binding suggestion over the product to be used by the Customer in its project. Insofar as
Hilti's technical advice is based on object or project related framework conditions, it is the Customer's sole
responsibility to ensure and verify this advice is under the actual circumstances and correspond to the specific
application intended by the Customer. Even slight deviations in design or slight differences between the actual
conditions and those specified by the Customer to Hilti, which Hilti has used for providing the technical advice,
will require a technical re-evaluation and re-calculation, which shall be the Customer's sole responsibility to
arrange with Hilti.
5. Designs and calculations are carried out with the relevant Hilti Profis calculation software or R-stab
software, details about the software, its limitations and underlying measurement methods can be obtained
from Hilti. Hilti designs and calculations are based on codes, general design standards, and Hilti-published
data current as of their creation date. For Hilti component and connection design see published technical data,
including material and cross-section properties, allowable load values, factors of safety, methods of
calculation, and limiting factors.
6. When providing designs and calculations, Hilti does not consider the following technical requirements:
If any of the above technical requirements need to be considered, Customer must specifically inquire with Hilti
whether this is possible. Hilti must agree in writing (typically mentioned in Technical report) to provide a solution
taking the above technical requirements into account, otherwise they are not considered.
Technical report
KSA
7. If the bill of materials contains Hilti anchors, Profis MSE and/or Profis Engineering software is utilized
for the calculation. Load values of the anchors are published in the current Technical Manual.
Technical advice of direct fastening (DX) connections is based on FTM Hilti Fastening technology Manual.
8. In case of modification or additional object or project related framework conditions which require
additional technical advice from Hilti, Hilti may accept to do so at an additional charge to be agreed with the
Customer.
9. The technical advice refers exclusively to products sold by Hilti and it is not transferable to products
from other manufacturers. All technical solutions communicated as part of the technical advice are always
object or project specific and non-transferable. It is therefore the Customers' sole liability to decide whether
to acquire or not the product suggested by Hilti; the Product shall be sold on the sole basis of Hilti’s standard
product warranty.
10. Unless expressly stated or agreed otherwise, performance deadlines and dates in the technical advice
are always non-binding.
11. Technical recommendations made by Hilti to Customers are deemed to be non-binding and for the
only purpose to provide the Customer with an initial indication of technical feasibility of Hilti's products and a
provisional estimation of material costs. The Technical recommendations constitute a conceptual or detailed
design, and must be reviewed and approved by the appropriate and responsible person from the Customer’s
side. In particular regarding conformity with the data in the technical data sheets, technical manuals, operating
instructions and approvals of the respective Hilti products, the applicable laws and regulations, the recognized
engineering standards and the on-site conditions. The technical data sheets, technical manuals, operating
instructions and approvals for Hilti products can be viewed at https://www.hilti.sa/
or ordered from Hilti.
12. Hilti's liability is limited to direct damage caused by intent and gross negligence, so HILTI is not liable
for consequential damages, loss of business, damages or any other variation that impacts the assets of the
Customer or any third party.
13. Personal data, sensitive personal data, databases, and other information that may be considered
protected will be treated in accordance with Hilti data protection policy and in accordance with current
regulations.
14. Additionally, the Customer declares to know and accept the Hilti Terms and Conditions of Sale that
can be consulted in https://www.hilti.sa/content/hilti/META/SA/en/support/legal/index/terms.html
which are understood to be an integral part of this document. In case of contradiction between the Terms and
Conditions of Sale of Hilti and this document, the latter will always prevail.
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Technical report
KSA
8. Appendices
8.1. Appendix 01 – Engineering Input Checklist/ Client Input
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
LEGEND/SYMBOLS Legends: SYMBOLS AND LEGEND: LEGENDS KEY PLAN
C 9.
FLUIDS IS TO BE DEFINED BY THE CONTRACTOR IN ACCORDANCE WITH THE LATERAL BEARING
CAPACITY OF SURROUNDING SUB-GRADE AT EACH RELEVANT LOCATION
THE ORIENTATION OF WASHOUT CHAMBERS SHOULD BE TO SUIT SITE CONDITIONS
C
10. WHERE REQUIRED THE CONTRACTOR SHALL INSTALL A DRAIN FROM HYDRANT CHAMBERS TO A
SOAKAWAY. SOAKAWAY SIZES TO BE DETERMINED BY ENGINEER ON SITE
11. DRAW PITS FOR DUCTED ELECTRICAL POWER AND TELECOMMUNICATIONS SERVICES TO BE
PROVIDED TO ASSIST CABLE PULLING WHERE LENGTHS OF DUCTING BETWEEN JUNCTIONS
EXCEED 200m IN LENGTH
12. UTILITIES INFRASTRUCTURE CONTAINMENT SERVING CRESCENTS, ANCILLARY BUILDINGS AND
GARDENS SHALL TERMINATE IN ACCESS PITS AND/OR BURIED ACCESS CHAMBERS IN THE
VICINITY OF THE APPROPRIATE PLANTROOMS. FINAL CONNECTIONS INTO INDIVIDUAL
PLANTROOMS FROM THE RELEVANT UTILITY TERMINATION PITS ARE SHOWN ON THE RELEVANT
MEP PLANTROOM DRAWINGS
13. FINAL CO-ORDINATION OF CONNECTIONS TO SECURITY BOLLARDS, CESSPOOLS, PUMPING
STATIONS, BULK WATER STORAGE TANKS, AND LPG GAS COMPOUNDS IS TO BE IN ACCORDANCE
WITH MANUFACTURER/SPECIALIST SUB-CONTRACTOR DETAILS
14. ALL MEP SERVICES SHOULD BE READ FROM (F.F.L) FINISH FLOOR LEVEL
TOH +874.00
+TR 874.50BOH+870.75
TOH +874.00 +BOH 870.75
BOH+870.75
+TR 874.50
TOH +874.00
BOH+869.00 +TR 874.50
+BOH 870.75 E
+BOH 869.00
TOH +874.00 +TM 874.45
+TR 874.50 BOH+869.00 +TM 874.45
+BOH 869.00
+TR 874.50 +TW 874.80
+TM 869.34
F +TR 874.50
+BOH 869.00 +TM 872.45
+TR 874.50 +TR 874.50
+BOH 869.00 +BR 869.75
+BR 869.20
TSE 869.36
TP 869.26 N KEYPLAN
TOH +872.00
+TR 872.50 BOH+868.75
+TM 869.373
TOH +874.00 +BOH 868.75 +TM 869.335
+TM 869.38 TP 869.255
BOH+869.00
+TD 867.15
+TR 869.60
HR Makka
TSE 869.355
TP 869.293
+WL 869.00 TP 869.255 TSE 869.36
TP 869.30
+BL 867.25
TSE 869.40
TSE 869.393
0.4
5%
0.45%
0.4
5% TP 869.255
+TM 869.34
F
+TR 874.50 TSE 869.37
+TM 869.38 +TR 869.40 TP 869.26 TP 869.20
+BR 869.30 TR 869.50 TP 869.27
5%
+TR 869.50 TR 869.40 0.4
TOH +874.00 869.20m
0.15%
+BOH 869.00 +TR 874.50
+TR 874.50 +BL 868.00 +BOH 869.00
TOH +874.00
+BOH 870.00 BOH+869.00
TOH +874.00
BOH+870.00
TOH +874.00 +TR 874.50
+BOH 869.00
+TM 874.45 REFERENCE DRAWINGS
0.45%
BOH+869.00
TOH +874.00 KAIG3-SD-CG-L-HP-1002-01 CENOZOIC GARDEN LEVELS AND GRADING PLAN
BOH+869.00 CENOZOIC GARDEN HDCC CUBES LAYOUT PLAN (SHEET 1
KAIG3-SD-CG-C-GA-1520-00 OF 2)
+TM 869.38 +TR 874.50
+BOH 869.00
CRESCENT 1 CENOZOIC GARDEN UNDERGROUND FIRE
G
TM+869.48 KAIG3-SD-CG-M-FF-1001-00
FIGHTING LAYOUT SHEET 1 OF 2
TP 869.215 TM
+TR 874.50 TR 869.50 + TM TSE 869.195
TSE 869.32 +869.30
TOH +873.10
CRESCENT 1 CENOZOIC GARDEN CHILLD WATER
+BR 869.30 +869.30 TP 869.295 KAIG3-SD-CG-M-HP-1000-01
TSE 869.32 TP 869.22 BOH+869.10 PIPEWORK LAYOUT MASTER PLAN
TR 873.60 +
ENTR
+TM 874.45 +TR 874.50
H BL +868.80
TP 869.22
TR 869.50 0.
+BOH 869.00
15%
+BOH 869.10
KAIG3-SD-CG-M-HV-1000-01
CRESCENT 1 CENOZOIC GARDEN VENTILATION LAYOUT
MASTER PLAN
45 0.
ANCE
TP 869.215 % TM CRESCENT 1 CENOZOIC GARDEN UNDERGROUND
TP 869.191 +TM 869.275 KAIG3-SD-CG-M-DP-1001-01
TSE 869.315 +869.267 DRAINAGE LAYOUT SHEET 1 OF 2
+TW 874.50 TSE 869.291 CRESCENT 1 CENOZOIC GARDEN WATER FEATURE WET
KAIG3-SD-CG-M-DP-7001-00
TM WELL DETAILS
TP 869.187
+869.295 CRESCENT 1 CENOZOIC GARDEN WATER FEATURE PIPE
TSE 869.287 KAIG3-SD-CG-M-DP-1003-00
ROUTING PLAN LAYOUT SHEET 1 OF 2
BL +867.78 MH CENOZOIC GARDEN POWER CONTAINMENT LAYOUT
TM TSE 869.287
+869.20
KAIG3-SD-CG-E-CR-1003-00
SHEET 2 H
+869.266 CENOZOIC GARDEN LOW CURRENT CONTAINMENT
TSE 869.286 TP 869.187 F.F.L. KAIG3-SD-CG-LC-CR-1003-00
+TM 869.267 LAYOUT SHEET 2
TP 869.186 TP 869.179
+TD 867.15
TR 869.40 KAIG3-SD-CG-L-IR-1001-00 CENOZOIC GARDEN IRRIGATION SYSTEM
+TM 874.45 TOH +874.00 +WL 869.00
I BOH+869.00 TM+869.38 TP 869.184
0.45%
+TR 874.50 POOL 1 BL +867.35 TSE 869.284 TP 869.20
TM TP
+869.264 869.195 TP 869.20
+TR 869.40 +TM 869.275 TSE
869.295
01 07.09.23 ISSUED FOR APPROVAL ZHBG
+TM 869.223 TP 869.19 00 16.02.23 ISSUED FOR APPROVAL ZHBG
55 %
CHWP AREA (2) TSE
TSE
869.25
0. REVISION
NO.
DATE PURPOSE & REMARKS ZHBG I
TD 869.15
TM
869.25
+869.23
TR 869.60 TP 869.15 TP 869.15 TSE 869.30 Trade ARCHITECTURE LANDSCAPE STRUCTURAL MECHANICAL ELECTRICAL
TR 869.40
TM+869.58 Date:
TP
J 869.20
0.15
TM+869.48 +TM 869.28
Sign:
TOH +874.00 TP 869.276
%
TM +869.347
0.45 %
BOH+869.00 TSE 869.376 +TR 873.00
+TR 874.50 +TR 874.50 +BR 869.10
TSE 869.367 BL +867.78
+BOH 869.00 +BR 869.20 TM TR 869.30
TP 869.267 TSE 869.276 +TM 869.256 KINGDOM OF SAUDI ARABIA
+869.371
TP 869.171 TP 869.176
TR 869.50 PROJECT TITLE:
TP 869.262 BL +868.80
+TM 869.251 TSE 869.271
TSE 869.370 TP 869.20
0.
TP 869.270
TP 869.267 55
TSE 869.367 %
+TR 873.00
+BOH 869.25
+TR 873.00
+BOH 869.25 KING ABDULLAH INTERNATIONAL GARDENS
.\1A_03_02.jpg
J
TP 869.265 STAGE 3
0.45 %
TOH +872.50
TP 869.270 BOH+869.25
TSE 869.370 +TM 869.313
TP 869.242
+TR 874.50 OWNER:
0.35
+TR 874.50
+BR 869.20 TR 869.40
K TP 869.237 0.55%
TP 869.233 TSE 869.333
%
TP 869.221
0.45
+TW 874.50 TP 869.233 MINISTRY OF MUNICIPAL AND RURAL AFFAIRS
TSE 869.360
TM+869.335 AL RIYADH MUNICIPALITY .\55.png
%
TOH +874.00
TOH +874.00 +TR 874.50 BOH+869.00 TM +869.301
BOH+869.00 +BOH 869.00
+TR 874.50
+BOH 870.00 TM
TOH +874.00
BOH+870.00
+869.278
TSE 869.298
TOH +872.50
+ TW 874.80 DESIGNER: K
TP 869.20
0.35 %
TP 869.198 BOH+869.25
TOH +874.00
.\DSIGNER.jpg
+TM 874.45 BOH+869.00
L TP 869.243 TP 869.238
TM+869.323 TOH +874.00
BOH+869.00
TSE 869.343
+TR 874.50
TSE 869.343 +TR 873.00 +869.20 CONSULTANT :
+TR 874.50
+BOH 869.00 +BR 869.20 TP 869.333 +TR 874.50 +BOH 869.25 T.S.L.
TM+ 869.323 +TM 874.45 TP 869.193
+BOH 869.00
+TR 869.40 TSE 869.293
TM .\dar cad.jpg
0.
TOH +874.00
35
BOH+869.00 +869.273
%
TSE 869.372
TP 869.272 TOH +872.50
0.45
+TR 874.50
BOH+869.25 MAIN CONTRACTOR: L
%
0.35 %
TP 869.25
TSE 869.35
TP 869.20
TP 869.238
TP 869.188
0.35 %
TP 869.165
TM+869.24
TOH
+TR +872.50
873.00
BOH+869.25
+BR 869.35 +TR 872.50
+BOH 868.75
.\ZDHBG.PNG M
+TWS 869.00 TSE 869.26
0.
TP 869.25 DISCIPLINE:
TSE 869.362 TSE 869.338 TP 869.16 BOH+868.75
ELECTROMECHANICAL
%
TSE 869.35
TM+869.342
TR 869.40 BOH+868.75
+BL 868.40 KAIG3-SD-CG-G-MS-4001-01
0.5
0.3
+TR 874.50 Date: Drawn By: In Charge: Checked By:
0%
BL +867.35 +TR 871.50 TP 869.20
+BOH 869.00
+BOH 868.75
TR 869.40 07.09.23 GK SK SAN
5%
0.3
FOR CONTINUATION REFER TO DRG. NO. KAIG3-SD-CG-G-MS-4002-01 Scale: 1:100 Size: A0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
KEY PLAN
LEGEND/SYMBOLS Legends: SYMBOLS AND LEGEND: LEGENDS
A L
FGL
LENGTH OF PIPE
FINISHED GROUND LEVEL
FD
L/L
FIRE DAMPER
LOW LEVEL SUPPLY AIR DUCT A
TOC TOP OF CULVERT H/L HIGH LEVEL
SC
IL INVERT LEVEL F/A
T/A
FROM ABOVE
TO ABOVE
EXHAUST AIR DUCT
sketch-Layout2-Layout1 (3)1.jpg
EGL EXISTING GROUND LEVEL
U DATA F/B FROM BELOW
MATCHLINE AHU RETURN OPENING
T/B TO BELOW
FP
FLOW DIRECTION SAD SUPPLY AIR DUCT
RAD RETURN AIR DUCT JET NOZZLE DIFFUSER
FAD FRESH AIR DUCT
FIRE HOSE REEL CABINET EAD EXHAUST AIR DUCT
SD SUPPLY DIFFUSER DRUM JET DIFFUSER
SG SUPPLY GRILLE
LSD LINEAR SUPPLY DIFFUSER
INTERFACE PIT AIR VALVE CHAMBER
ED EXHAUST DIFFUSER
EG EXHAUST GRILLE FLOOR LINEAR GRILLE
LRD LINEAR RETURN DIFFUSER NOTE/LEGEND :
B VALVE PIT WASHOUT CHAMBER ATT
FLEX
SOUND ATTENUATOR
FLEXIBLE CONNECTION
FLOOR GRILLE IN B
LANDSCAPE AREA General Notes:
BOD BOTTOM OF DUCT
ISOLATION PIT BOU BOTTOM OF UNIT 1. THIS DRAWING IS ISSUED FOR INFORMATION ONLY. THE FINAL COMPOSITE SHOP DRAWING WILL
THRUST BLOCK FIRE DAMPER
BOP BOTTOM OF PIPE FOLLOW THE APPROVAL ON THE SEPARATE TRADES.
2. ALL DIMENSIONS ARE IN mm UNLESS NOTED OTHERWISE NOTED.
FFL FINISH FLOOR LEVEL
VOLUME DAMPER 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL RELATED ARCHITECTURAL,
LANDSCAPE, STRUCTURAL AND SERVICES DRAWINGS & SPECIFICATIONS.
4. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE SPECIFICATIONS
SOUND ATTENUATOR 5. ALL MANHOLES, DRAW PITS AND ACCESS CHAMBERS SHALL BE CONSTRUCTED TO HAVE THE
CHAMBER COVER LEVEL FLUSH WITH THE SURROUNDING SITE TOPOGRAPHY
6. UNLESS OTHERWISE INDICATED, ALL DRAW PITS AND ACCESS CHAMBERS SHALL HAVE FRAME
AND COVER SUROUNDS CONSTRUCTED FROM 150mm PRE-CAST CONCRETE OR 150mm MORTAR
AIR HANDLING UNIT JOINTED DENSE CONCRETE BLOCKS, MINIMUM GRADE C20
7. FOR PITS USED TO ACCESS CABLED SERVICES, END DUCTS ARE TO BE IN LINE TO ALLOW
₂ ₂ CABLES TO BE PULLED STRAIGHT THROUGH WHERE REQUIRED. WHERE POSSIBLE DUCTS ARE
TO BE POSITIONED EQUIDISTANT FROM SIDE WALLS OR A MINIMUM OF 85mm DISTANT FROM THE
DUCT WALL OPENING INSIDE FACE OF SIDE WALLS
₂ ₂
8. THE FINAL DESIGN OF ANY THRUST BLOCKS REQUIRED FOR PIPED UTILITY SERVICES CARRYING
C 9.
FLUIDS IS TO BE DEFINED BY THE CONTRACTOR IN ACCORDANCE WITH THE LATERAL BEARING
CAPACITY OF SURROUNDING SUB-GRADE AT EACH RELEVANT LOCATION
THE ORIENTATION OF WASHOUT CHAMBERS SHOULD BE TO SUIT SITE CONDITIONS
C
10. WHERE REQUIRED THE CONTRACTOR SHALL INSTALL A DRAIN FROM HYDRANT CHAMBERS TO A
SOAKAWAY. SOAKAWAY SIZES TO BE DETERMINED BY ENGINEER ON SITE
11. DRAW PITS FOR DUCTED ELECTRICAL POWER AND TELECOMMUNICATIONS SERVICES TO BE
PROVIDED TO ASSIST CABLE PULLING WHERE LENGTHS OF DUCTING BETWEEN JUNCTIONS
EXCEED 200m IN LENGTH
12. UTILITIES INFRASTRUCTURE CONTAINMENT SERVING CRESCENTS, ANCILLARY BUILDINGS AND
GARDENS SHALL TERMINATE IN ACCESS PITS AND/OR BURIED ACCESS CHAMBERS IN THE
VICINITY OF THE APPROPRIATE PLANTROOMS. FINAL CONNECTIONS INTO INDIVIDUAL
PLANTROOMS FROM THE RELEVANT UTILITY TERMINATION PITS ARE SHOWN ON THE RELEVANT
MEP PLANTROOM DRAWINGS
13. FINAL CO-ORDINATION OF CONNECTIONS TO SECURITY BOLLARDS, CESSPOOLS, PUMPING
STATIONS, BULK WATER STORAGE TANKS, AND LPG GAS COMPOUNDS IS TO BE IN ACCORDANCE
WITH MANUFACTURER/SPECIALIST SUB-CONTRACTOR DETAILS
14. ALL MEP SERVICES SHOULD BE READ FROM (F.F.L) FINISH FLOOR LEVEL
15. MAXIMUM DISTANCES BETWEEN SUPPORTS IS 1500mm UNLESS OTHERWISE INDICATED.
16. PVC COATED RIGID STEEL CONDUIT/ CABLE TRAY AND FITTINGS (FOR OUTDOOR, WET AREAS
AND ROOMS).
D 17. INSTALL AN APPROPRIATE EXPANTION FITTING WHEREVER THE CONDUIT/ CABLE TRAY RUN
CRSSES AN EXPANSION JOINT. D
F
N KEYPLAN
2" 2"
4" 4"
Makka
F
869.20m
REFERENCE DRAWINGS
SSL +869.35
+TP 870.10
+TP 868.500
H
6" 6"
+TP 869.35
OWNER:
K
.\AL RIYADH MUNICIPALITY.jpg
DESIGNER: K
.\DSIGNER.jpg
L
CONSULTANT :
.\dar cad.jpg
MAIN CONTRACTOR: L
+TP 869.182
+TP 869.15
M .\ZDHBG.PNG M
+TP 868.000 +TP 868.000
∅160 HDPE IL: 868.450
DISCIPLINE:
ELECTROMECHANICAL
110∅ UPVC DRAWING TITLE :
IL: 867.730 CRESCENT 1 - CENOZOIC GARDEN
MEP COMPOSITE LAYOUT
SECTIONS
DRAWING NO:
N SECTION - C SECTION - D
KAIG3-SD-CG-G-MS-2001-02 N
Scale: 1:50 Scale: 1:50
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Technical report
KSA
The company receiving this design package is solely responsible for confirming, reviewing and approving the adequacy and accuracy of all
information contained herein; and for verifying that the proposed solution is suitable for the intended applications.
Case-1
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 26
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 26
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -215.00 0.00 -500.00 MT-B-O2 MT-B-O2 (C)
2 - -215.00 0.00 -72.25 MT-C-LL1 MT-C-LL1 (C)
3 - 733.50 0.00 -72.25 MT-C-LL1 MT-C-LL1 (C)
4 2 733.50 0.00 -500.00 MT-B-O2 MT-B-O2 (C)
5 - 733.50 0.00 -235.46 MT-AB-LL2 45 MT-AB-LL2 45 (E)
6 3 733.50 264.54 -500.00 MT-AB A MT-AB A (C)
7 - -215.00 0.00 -235.46 MT-AB-LL2 45 MT-AB-LL2 45 (E)
8 4 -215.00 264.54 -500.00 MT-AB A MT-AB A (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 26
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
2 no no no no yes yes - - - - 0.001 0.001
2 no no no no yes yes - - - - 0.001 0.001
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 26
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2272094 2-hole Baseplate MT-B-O2 2 2.05
11 2346395 Angle brace MT-AB A set adjustable 2 0.88
Quantity Weight
Position Item Number Description
[-] [kg]
9 2272047 Angle connector MT-C-LL1 2 0.67
10 2272115 Angle brace MT-AB-LL2 45 2 1.11
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2273254 Hexagon bolt MT-TLB 16 0.40
7 2272080 Twist-Lock MT-TL M10 16 0.56
8 2105719 Stud anchor HST3 M12x115 40/20 8 0.80
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 26
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 275.00 0.00 0.00 -1.79 0.00 0.00 0.00
2 Design 2 673.50 0.00 0.00 -1.79 0.00 0.00 0.00
3 Wind (+x) 2 474.25 0.53 -0.00 -0.00 -0.00 -0.00 -0.00
4 Wind (-x) 2 474.25 -0.53 -0.00 -0.00 -0.00 -0.00 -0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 26
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
21 Self Weight Support 1 0.00 427.75 0.00 0.00 -0.02 0.00 0.00 0.00
22 Self Weight Support 2 0.00 948.50 0.00 0.00 -0.02 0.00 0.00 0.00
23 Self Weight Support 3 0.00 427.75 0.00 0.00 -0.02 0.00 0.00 0.00
24 Self Weight Support 4 0.00 374.12 0.00 0.00 -0.02 0.00 0.00 0.00
25 Self Weight Support 5 0.00 374.12 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 26
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 26
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 26
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 4.08 -2652.65 -3099.95 -2652.65
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 26
Version: 1.13.1
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Beam No. 1
Beam No. 2
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 26
Version: 1.13.1
Beam No. 3
Beam No. 4
Beam No. 5
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 26
Version: 1.13.1
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 26
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 26
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 26
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 26
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 016-SLS Relative (Beam) 427.75 L/200 -0.08 0.00
2 004-SLS Relative (Beam) 948.50 L/200 -2.90 61.10
3 016-SLS Relative (Beam) 427.75 L/200 0.00 0.00
4 016-SLS Relative (Beam) 374.12 L/200 0.00 0.00
5 016-SLS Relative (Beam) 374.12 L/200 0.00 0.00
*016-SLS: SW + Live + Snow + Wind (-x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * 0.60 * LC9
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 26
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-LL1
Fx Fy Fz Mx My Mz
Connector variant: MT-C-LL1 (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -0.24 -0.24 -1.80 0.00 0.00 -0.00
Resistance: 8.20 1.24 8.06 0.03 0.19 0.03
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 44.93 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Connector: MT-AB-LL2 45
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-LL2 45 (E)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: -0.59 0.00 -0.00 -0.00 0.00 0.00
Resistance: 9.72 0.10 0.10 0.10 0.00 0.00
abs(Fx.ed/Fx.rd);abs(Fy.ed/Fy.rd);abs(Fz.ed/Fz.rd);abs(Mx.ed/Mx.rd);abs(My
Equation:
.ed/My.rd);abs(Mz.ed/Mz.rd)
Utilization: 6.03 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 26
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 26
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 26 / 26
Case-2
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 26
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 26
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 - -190.75 0.00 5482.95 MT-C-GS A OC MT-C-GS A OC (C_D_CS)
2 - 709.25 0.00 5482.95 MT-C-GS A OC MT-C-GS A OC (C_D_CS)
3 1 -190.75 0.00 -500.00 MT-B-GL O4C OC MT-B-GL O4C OC (C)
4 2 709.25 0.00 -500.00 MT-B-GL O4C OC MT-B-GL O4C OC (C)
5 - -190.75 0.00 5122.95 MT-C-GS A OC MT-C-GS A OC (C_D_CS)
6 - 709.25 0.00 5122.95 MT-C-GS A OC MT-C-GS A OC (C_D_CS)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 26
Version: 1.13.1
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 26
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2343282 Baseplate MT-B-GL O4C OC 2 13.04
Quantity Weight
Position Item Number Description
[-] [kg]
3 2272068 Angle connector MT-C-GS A OC adjustable 8 3.12
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
4 2272084 Thread forming bolt MT-TFB OC 44 1.25
6 2105870 Stud anchor HST3-R M12x115 40/20 8 0.81
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 26
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 4 250.00 0.00 0.00 -1.79 0.00 0.00 0.00
2 Design 4 650.00 0.00 0.00 -1.79 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 26
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
23 Self Weight Support 1 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
24 Self Weight Support 2 0.00 5982.95 0.00 0.00 -0.09 0.00 0.00 0.00
25 Self Weight Support 3 0.00 5982.95 0.00 0.00 -0.09 0.00 0.00 0.00
26 Self Weight Support 4 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 26
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 26
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 26
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
2039000.00 7.82 -6349.48 -6349.48 -6349.48
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
15470000.00 17.95 -30169.60 -30169.60 -30169.60
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 26
Version: 1.13.1
5.2.2.1 Overview
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 26
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
Beam No. 4
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 26
Version: 1.13.1
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 26
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 26
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 26
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 26
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 016-SLS Relative (Beam) 900.00 L/200 -0.04 0.00
2 016-SLS Relative(Cantilever) 5982.95 L/150 36.94 92.61
3 016-SLS Relative(Cantilever) 5982.95 L/150 36.94 92.61
4 016-SLS Relative (Beam) 900.00 L/200 -0.01 0.00
*016-SLS: SW + Live + Snow + Wind (-x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * 0.60 * LC9
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 26
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-GS A OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GS A OC (C_D_CS)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: 0.66 0.24 2.33 0.00 -1.06 0.02
Resistance: 25.24 10.59 41.34 1.06 2.21 0.40
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 64.27 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 26
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 26
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 26 / 26
Case-3
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 25
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 25
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 - -190.75 0.00 5482.95 MT-C-GS A OC MT-C-GS A OC (C_CS)
3 1 -190.75 0.00 -500.00 MT-C-GL OC MT-C-GL OC (C_2)
4 - 528.78 0.00 5482.95 MT-AB-G T OC MT-AB-G T OC (C_D)
5 - -190.75 0.00 4831.22 MT-B-GS AB OC MT-B-GS AB OC (C)
1.3 Members
1.4 Connections
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
3 no no no no yes yes - - - - 0.000 0.000
3 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 25
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
6 2272066 Angle connector MT-C-GL OC 2 2.32
Quantity Weight
Position Item Number Description
[-] [kg]
4 2272068 Angle connector MT-C-GS A OC adjustable 1 0.39
8 2272116 Angle brace MT-AB-G T OC adjustable 2 0.70
9 2332787 Baseplate MT-B-GS AB OC 1 1.65
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
5 2272084 Thread forming bolt MT-TFB OC 24 0.68
7 2105870 Stud anchor HST3-R M12x115 40/20 4 0.41
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 25
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
13 Design 1 250.00 0.00 0.00 -0.11 0.00 0.00 0.00
14 Design 1 650.00 0.00 0.00 -0.11 0.00 0.00 0.00
15 Wind (+x) 1 450.00 0.17 0.00 0.00 0.00 0.00 0.00
16 Wind (-x) 1 450.00 -0.17 -0.00 -0.00 -0.00 -0.00 -0.00
17 Self Weight Support 1 0.00 0.00 0.00 -0.00 0.00 0.00 0.00
18 Self Weight Support 2 5982.95 0.00 0.00 -0.02 0.00 0.00 0.00
19 Self Weight Support 1 719.53 0.00 0.00 -0.01 0.00 0.00 0.00
20 Self Weight Support 2 651.73 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 25
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
21 Self Weight Support 1 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
22 Self Weight Support 2 0.00 5982.95 0.00 0.00 -0.09 0.00 0.00 0.00
23 Self Weight Support 3 0.00 970.81 0.00 0.00 -0.04 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 25
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 25
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 25
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
2039000.00 3.91 -6349.48 -6349.48 -6349.48
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
15470000.00 8.97 -30169.60 -30169.60 -30169.60
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 25
Version: 1.13.1
5.2.2.1 Overview
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.50 * LC8
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 25
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.50 * LC8
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 25
Version: 1.13.1
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 25
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 25
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 25
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/150
☑Maximum Allowable Deflection (Cantilever)L/75
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 25
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 006-SLS Relative(Cantilever) 900.00 L/75 -9.16 76.32
2 006-SLS Relative(Cantilever) 5982.95 L/75 -40.28 50.50
3 006-SLS Relative(Cantilever) 970.81 L/75 9.88 76.35
*006-SLS: SW + Wind (+x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC8
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 25
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-GS A OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GS A OC (C_CS)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 1
Local Forces: 0.20 0.00 0.12 0.00 -0.01 0.00
Resistance: 9.47 3.64 16.71 0.16 0.36 0.13
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 6.72 % OK
Governing Load
1.35 * LC1 + 1.00 * LC7
Combination
Connector: MT-AB-G T OC
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-G T OC (C_D)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 4
Local Forces: -0.25 0.02 0.00 0.00 0.00 0.00
Resistance: 32.99 6.44 1.83
Equation: (( Fx.ed^2 + Fy.ed^2 )^0.5)/Fx.rd + Fz.ed / Fz.rd+Mx.ed/Mx.rd
Utilization: 0.77 % OK
Governing Load
1.35 * LC1 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 25
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 25
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 25
Case-4
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 23
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 23
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-O2 OC MT-B-O2 OC (C)
2 - -190.75 0.00 -162.05 MT-C-L2 OC MT-C-L2 OC (C)
3 - 709.25 0.00 -162.05 MT-C-L2 OC MT-C-L2 OC (C)
5 2 709.25 0.00 -500.00 MT-B-O2 OC MT-B-O2 OC (C)
1.3 Members
1.4 Connections
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
1 no no no no yes yes - - - - 0.001 0.001
1 no no no no yes yes - - - - 0.001 0.001
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 23
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
3 2272096 2-hole Baseplate MT-B-O2 OC 2 2.05
Quantity Weight
Position Item Number Description
[-] [kg]
7 2271519 Angle connector MT-C-L2 OC 2 0.52
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
4 2273256 Hexagon bolt MT-TLB OC 10 0.25
5 2272082 Twist-Lock MT-TL M10 OC 10 0.35
6 2105870 Stud anchor HST3-R M12x115 40/20 4 0.41
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 23
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 1 250.00 0.00 0.00 -1.79 0.00 0.00 0.00
2 Design 1 650.00 0.00 0.00 -1.79 0.00 0.00 0.00
3 Seismic (+x) 1 250.00 0.02 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 1 250.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
5 Seismic (+x) 1 650.00 0.02 0.00 0.00 0.00 0.00 0.00
6 Seismic (-x) 1 650.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 23
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
19 Self Weight Support 1 0.00 900.00 0.00 0.00 -0.02 0.00 0.00 0.00
20 Self Weight Support 2 0.00 650.00 0.00 0.00 -0.02 0.00 0.00 0.00
21 Self Weight Support 3 0.00 650.00 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 23
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 23
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 23
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 2.04 -2652.65 -3099.95 -2652.65
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 23
Version: 1.13.1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 23
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 23
Version: 1.13.1
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 23
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 23
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 23
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 23
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative (Beam) 900.00 L/200 2.40 53.34
2 004-SLS Relative (Beam) 650.00 L/200 -0.03 0.00
3 004-SLS Relative (Beam) 650.00 L/200 -0.04 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 23
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-L2 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-L2 OC (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -0.37 0.24 1.80 0.00 -0.00 0.00
Resistance: 5.84 1.56 12.38 0.06
Equation: abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)
Utilization: 36.42 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 23
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 23
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 23
Case-5-7-10
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 19
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 19
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-T OC MT-B-T OC (E)
1.3 Members
1.4 Connections
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 19
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
2 2272092 2-hole Baseplate MT-B-T OC 1 0.56
Quantity Weight
Position Item Number Description
[-] [kg]
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
3 2272082 Twist-Lock MT-TL M10 OC 2 0.07
4 2273256 Hexagon bolt MT-TLB OC 2 0.05
5 2105870 Stud anchor HST3-R M12x115 40/20 2 0.20
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 19
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
13 Design 1 535.00 0.00 0.00 -0.11 0.00 -0.03 0.00
14 Self Weight Support 1 0.00 0.00 0.00 -0.01 0.00 0.00 0.00
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
15 Self Weight Support 1 0.00 650.00 0.00 0.00 -0.01 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 19
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 19
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 19
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 19
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
8522000.00 1.49 -1004.46 -2443.24 -1004.46
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 19
Version: 1.13.1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Beam No. 1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 19
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 19
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 19
Version: 1.13.1
Moment around Z
Buckling ratio
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 19
Version: 1.13.1
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative(Cantilever) 650.00 L/150 1.69 39.03
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 19
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 19
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 19
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 19
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 19
Case-6
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 23
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 23
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-GS T OC MT-B-GS T OC (C_MT-70)
2 - -190.75 0.00 -43.10 MT-C-GS A OC MT-C-GS A OC (C_CS)
3 - 709.25 0.00 -43.10 MT-C-GS A OC MT-C-GS A OC (C_CS)
5 2 709.25 0.00 -500.00 MT-B-GS T OC MT-B-GS T OC (C_MT-70)
1.3 Members
1.4 Connections
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
1 no no no no yes yes - - - - 0.001 0.001
1 no no no no yes yes - - - - 0.001 0.001
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 23
Version: 1.13.1
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 23
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
3 2272100 Baseplate MT-B-GS T OC 2 4.33
Quantity Weight
Position Item Number Description
[-] [kg]
6 2272068 Angle connector MT-C-GS A OC adjustable 2 0.78
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
4 2272084 Thread forming bolt MT-TFB OC 20 0.57
5 2105870 Stud anchor HST3-R M12x115 40/20 4 0.41
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 23
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 1 250.00 0.00 0.00 -4.88 0.00 0.00 0.00
2 Design 1 650.00 0.00 0.00 -4.88 0.00 0.00 0.00
3 Seismic (+x) 1 250.00 0.05 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 1 250.00 -0.05 -0.00 -0.00 -0.00 -0.00 -0.00
5 Seismic (+x) 1 650.00 0.05 0.00 0.00 0.00 0.00 0.00
6 Seismic (-x) 1 650.00 -0.05 -0.00 -0.00 -0.00 -0.00 -0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 23
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
19 Self Weight Support 1 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
20 Self Weight Support 2 0.00 700.00 0.00 0.00 -0.04 0.00 0.00 0.00
21 Self Weight Support 3 0.00 700.00 0.00 0.00 -0.04 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 23
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 23
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 23
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
2039000.00 3.91 -6349.48 -6349.48 -6349.48
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 23
Version: 1.13.1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 23
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 23
Version: 1.13.1
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 23
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 23
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 23
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 23
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative (Beam) 900.00 L/200 2.41 53.66
2 004-SLS Relative (Beam) 700.00 L/200 -0.09 0.00
3 004-SLS Relative (Beam) 700.00 L/200 -0.02 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 23
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-GS A OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GS A OC (C_CS)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -0.76 0.66 4.90 0.00 -0.00 0.00
Resistance: 7.30 3.64 16.71 0.16 0.43 0.13
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 57.86 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 23
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 23
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 23
Case-8
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 26
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 26
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-O2B MT-B-O2B (C)
2 - -190.75 0.00 677.75 MT-C-LL1 MT-C-LL1 (C)
3 - 709.25 0.00 677.75 MT-C-LL1 MT-C-LL1 (C)
4 2 709.25 0.00 -500.00 MT-B-O2B MT-B-O2B (C)
5 - 709.25 0.00 88.87 MT-AB-LL2 45 MT-AB-LL2 45 (E)
6 3 709.25 588.87 -500.00 MT-AB A MT-AB A (C)
7 - -190.75 0.00 88.87 MT-AB-LL2 45 MT-AB-LL2 45 (E)
8 4 -190.75 588.87 -500.00 MT-AB A MT-AB A (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 26
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
2 no no no no yes yes - - - - 0.001 0.001
2 no no no no yes yes - - - - 0.001 0.001
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 26
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2282212 2-hole Baseplate MT-B-O2B 2 4.14
11 2346395 Angle brace MT-AB A set adjustable 2 0.88
Quantity Weight
Position Item Number Description
[-] [kg]
9 2272047 Angle connector MT-C-LL1 2 0.67
10 2272115 Angle brace MT-AB-LL2 45 2 1.11
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2273254 Hexagon bolt MT-TLB 20 0.50
7 2272080 Twist-Lock MT-TL M10 20 0.70
8 2105719 Stud anchor HST3 M12x115 40/20 8 0.80
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 26
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 275.00 0.00 0.00 -1.79 0.00 0.00 0.00
2 Design 2 673.50 0.00 0.00 -1.79 0.00 0.00 0.00
3 Wind (+x) 2 474.25 0.53 -0.00 -0.00 -0.00 -0.00 -0.00
4 Wind (-x) 2 474.25 -0.53 -0.00 -0.00 -0.00 -0.00 -0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 26
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
21 Self Weight Support 1 0.00 1177.75 0.00 0.00 -0.04 0.00 0.00 0.00
22 Self Weight Support 2 0.00 900.00 0.00 0.00 -0.02 0.00 0.00 0.00
23 Self Weight Support 3 0.00 1177.75 0.00 0.00 -0.04 0.00 0.00 0.00
24 Self Weight Support 4 0.00 832.79 0.00 0.00 -0.02 0.00 0.00 0.00
25 Self Weight Support 5 0.00 832.79 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 26
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 26
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 26
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
154300000.00 8.40 -7048.65 -6199.90 -7048.65
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 2.04 -2652.65 -3099.95 -2652.65
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 26
Version: 1.13.1
5.2.2.1 Overview
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 26
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
Beam No. 4
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 26
Version: 1.13.1
Beam No. 5
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 26
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 26
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 26
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 26
Version: 1.13.1
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 006-SLS Relative(Cantilever) 1177.75 L/150 3.91 49.76
2 004-SLS Relative (Beam) 900.00 L/200 -2.40 53.38
3 006-SLS Relative(Cantilever) 1177.75 L/150 3.91 49.77
4 016-SLS Relative (Beam) 832.79 L/200 0.00 0.00
5 016-SLS Relative (Beam) 832.79 L/200 0.00 0.00
*006-SLS: SW + Wind (+x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * LC8
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
*016-SLS: SW + Live + Snow + Wind (-x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * 0.60 * LC9
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 26
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-LL1
Fx Fy Fz Mx My Mz
Connector variant: MT-C-LL1 (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -0.24 -0.26 -1.90 -0.00 0.00 -0.00
Resistance: 8.20 1.24 8.06 0.03 0.19 0.03
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 47.16 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Connector: MT-AB-LL2 45
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-LL2 45 (E)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: -0.86 0.00 -0.01 -0.00 0.00 0.00
Resistance: 9.72 0.10 0.10 0.10 0.00 0.00
abs(Fx.ed/Fx.rd);abs(Fy.ed/Fy.rd);abs(Fz.ed/Fz.rd);abs(Mx.ed/Mx.rd);abs(My
Equation:
.ed/My.rd);abs(Mz.ed/Mz.rd)
Utilization: 8.82 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 26
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 26
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 26 / 26
Case-9
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 23
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 23
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-O2 OC MT-B-O2 OC (C)
2 - -190.75 0.00 -93.10 MT-C-L2 OC MT-C-L2 OC (C)
3 - 709.25 0.00 -93.10 MT-C-L2 OC MT-C-L2 OC (C)
4 2 709.25 0.00 -500.00 MT-B-O2 OC MT-B-O2 OC (C)
5 - 709.25 0.00 -258.66 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
6 3 709.25 241.34 -500.00 MT-AB A OC MT-AB A OC (C)
7 - -190.75 0.00 -258.66 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
8 4 -190.75 241.34 -500.00 MT-AB A OC MT-AB A OC (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 23
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
1 no no no no yes yes - - - - 0.001 0.001
1 no no no no yes yes - - - - 0.001 0.001
3 no no no no yes yes - - - - 0.000 0.000
3 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 23
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
6 2272096 2-hole Baseplate MT-B-O2 OC 2 2.05
12 2346396 Angle brace MT-AB A OC set adjustable 2 0.88
Quantity Weight
Position Item Number Description
[-] [kg]
10 2271519 Angle connector MT-C-L2 OC 2 0.52
11 2273585 Angle brace MT-AB-LL2 45 OC 2 1.11
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
7 2273256 Hexagon bolt MT-TLB OC 18 0.45
8 2272082 Twist-Lock MT-TL M10 OC 18 0.63
9 2105870 Stud anchor HST3-R M12x115 40/20 8 0.81
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 23
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 1 250.00 0.00 0.00 -3.18 0.00 0.00 0.00
2 Design 1 650.00 0.00 0.00 -3.18 0.00 0.00 0.00
3 Seismic (+x) 1 250.00 0.04 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 1 250.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
5 Seismic (+x) 1 650.00 0.04 0.00 0.00 0.00 0.00 0.00
6 Seismic (-x) 1 650.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
9 Pipe 1 250.00 0.32 0.32 0.00 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 23
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
22 Self Weight Support 1 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
23 Self Weight Support 2 0.00 406.90 0.00 0.00 -0.04 0.00 0.00 0.00
24 Self Weight Support 3 0.00 341.31 0.00 0.00 -0.02 0.00 0.00 0.00
25 Self Weight Support 4 0.00 341.31 0.00 0.00 -0.02 0.00 0.00 0.00
26 Self Weight Support 5 0.00 650.00 0.00 0.00 -0.04 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 23
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 23
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 23
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
158106000.00 3.85 -7804.06 -8037.37 -7804.06
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
154300000.00 4.20 -7048.65 -6199.90 -7048.65
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 2.04 -2652.65 -3099.95 -2652.65
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 23
Version: 1.13.1
5.2.2.1 Overview
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 23
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
Beam No. 4
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 23
Version: 1.13.1
Beam No. 5
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 23
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 23
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 23
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 23
Version: 1.13.1
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative (Beam) 900.00 L/200 0.01 0.00
2 004-SLS Relative (Beam) 406.90 L/200 0.00 0.00
3 004-SLS Relative (Beam) 341.31 L/200 0.00 0.00
4 004-SLS Relative (Beam) 341.31 L/200 0.00 0.00
5 004-SLS Relative (Beam) 650.00 L/200 -0.03 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 23
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-L2 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-L2 OC (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 2
Local Forces: 0.43 -0.43 3.20 -0.00 -0.00 -0.00
Resistance: 3.97 1.56 12.38 0.06
Equation: abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)
Utilization: 64.36 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Connector: MT-AB-LL2 45 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-LL2 45 OC (E)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 7
Local Forces: -1.04 0.00 -0.00 -0.00 0.00 0.00
Resistance: 9.72 0.10 0.10 0.10 0.00 0.00
abs(Fx.ed/Fx.rd);abs(Fy.ed/Fy.rd);abs(Fz.ed/Fz.rd);abs(Mx.ed/Mx.rd);abs(My
Equation:
.ed/My.rd);abs(Mz.ed/Mz.rd)
Utilization: 10.70 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 23
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 23
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 23
Case-11
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 23
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 23
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-O2 OC MT-B-O2 OC (C)
2 - -190.75 0.00 -93.10 MT-C-L2 OC MT-C-L2 OC (C)
3 - 709.25 0.00 -93.10 MT-C-L2 OC MT-C-L2 OC (C)
4 2 709.25 0.00 -500.00 MT-B-O2 OC MT-B-O2 OC (C)
5 - 709.25 0.00 -258.66 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
6 3 709.25 241.34 -500.00 MT-AB A OC MT-AB A OC (C)
7 - -190.75 0.00 -258.66 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
8 4 -190.75 241.34 -500.00 MT-AB A OC MT-AB A OC (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 23
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
2 no no no no yes yes - - - - 0.001 0.001
2 no no no no yes yes - - - - 0.001 0.001
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 23
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2272096 2-hole Baseplate MT-B-O2 OC 2 2.05
11 2346396 Angle brace MT-AB A OC set adjustable 2 0.88
Quantity Weight
Position Item Number Description
[-] [kg]
9 2271519 Angle connector MT-C-L2 OC 2 0.52
10 2273585 Angle brace MT-AB-LL2 45 OC 2 1.11
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2273256 Hexagon bolt MT-TLB OC 18 0.45
7 2272082 Twist-Lock MT-TL M10 OC 18 0.63
8 2105870 Stud anchor HST3-R M12x115 40/20 8 0.81
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 23
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 250.00 0.00 0.00 -3.18 0.00 0.00 0.00
2 Design 2 650.00 0.00 0.00 -3.18 0.00 0.00 0.00
3 Seismic (+x) 2 250.00 0.04 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 2 250.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
5 Seismic (+x) 2 650.00 0.04 0.00 0.00 0.00 0.00 0.00
6 Seismic (-x) 2 650.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
9 Pipe 2 250.00 0.32 0.32 0.00 0.00 0.00 0.00
10 Pipe 2 650.00 0.32 0.32 0.00 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 23
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
19 Self Weight Support 1 0.00 406.90 0.00 0.00 -0.04 0.00 0.00 0.00
20 Self Weight Support 2 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
21 Self Weight Support 3 0.00 406.90 0.00 0.00 -0.04 0.00 0.00 0.00
22 Self Weight Support 4 0.00 341.31 0.00 0.00 -0.02 0.00 0.00 0.00
23 Self Weight Support 5 0.00 341.31 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 23
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 23
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 23
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
154300000.00 8.40 -7048.65 -6199.90 -7048.65
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
158106000.00 3.85 -7804.06 -8037.37 -7804.06
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 2.04 -2652.65 -3099.95 -2652.65
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 23
Version: 1.13.1
5.2.2.1 Overview
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 23
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
Beam No. 4
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 23
Version: 1.13.1
Beam No. 5
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 23
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 23
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 23
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 23
Version: 1.13.1
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative (Beam) 406.90 L/200 -0.07 0.00
2 004-SLS Relative (Beam) 900.00 L/200 0.01 0.00
3 004-SLS Relative (Beam) 406.90 L/200 0.00 0.00
4 004-SLS Relative (Beam) 341.31 L/200 0.00 0.00
5 004-SLS Relative (Beam) 341.31 L/200 0.00 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 23
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-L2 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-L2 OC (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 2
Local Forces: 0.43 -0.43 3.20 0.00 -0.00 -0.00
Resistance: 3.97 1.56 12.38 0.06
Equation: abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)
Utilization: 64.36 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Connector: MT-AB-LL2 45 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-LL2 45 OC (E)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: -1.04 0.00 0.00 -0.00 0.00 0.00
Resistance: 9.72 0.10 0.10 0.10 0.00 0.00
abs(Fx.ed/Fx.rd);abs(Fy.ed/Fy.rd);abs(Fz.ed/Fz.rd);abs(Mx.ed/Mx.rd);abs(My
Equation:
.ed/My.rd);abs(Mz.ed/Mz.rd)
Utilization: 10.68 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 23
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 23
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 23
Case-12
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 23
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 23
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-O2B OC MT-B-O2B OC (C)
2 - -190.75 0.00 711.90 MT-C-L2 OC MT-C-L2 OC (C)
3 - 709.25 0.00 711.90 MT-C-L2 OC MT-C-L2 OC (C)
4 2 709.25 0.00 -500.00 MT-B-O2B OC MT-B-O2B OC (C)
5 - 709.25 0.00 278.45 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
6 3 709.25 766.68 -488.23 MT-AB A OC MT-AB A OC (C)
7 - -190.75 0.00 278.45 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
8 4 -190.75 766.68 -488.23 MT-AB A OC MT-AB A OC (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 23
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
2 no no no no yes yes - - - - 0.001 0.001
2 no no no no yes yes - - - - 0.001 0.001
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 23
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2282213 2-hole Baseplate MT-B-O2B OC 2 4.14
11 2346396 Angle brace MT-AB A OC set adjustable 2 0.88
Quantity Weight
Position Item Number Description
[-] [kg]
9 2271519 Angle connector MT-C-L2 OC 2 0.52
10 2273585 Angle brace MT-AB-LL2 45 OC 2 1.11
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2273256 Hexagon bolt MT-TLB OC 22 0.55
7 2272082 Twist-Lock MT-TL M10 OC 22 0.77
8 2105870 Stud anchor HST3-R M12x115 40/20 8 0.81
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 23
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 250.00 0.00 0.00 -3.18 0.00 0.00 0.00
2 Design 2 650.00 0.00 0.00 -3.18 0.00 0.00 0.00
3 Seismic (+x) 2 250.00 0.04 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 2 250.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
5 Seismic (+x) 2 650.00 0.04 0.00 0.00 0.00 0.00 0.00
6 Seismic (-x) 2 650.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
9 Pipe 2 250.00 0.32 0.32 0.00 0.00 0.00 0.00
10 Pipe 2 650.00 0.32 0.32 0.00 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 23
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
19 Self Weight Support 1 0.00 1211.90 0.00 0.00 -0.04 0.00 0.00 0.00
20 Self Weight Support 2 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
21 Self Weight Support 3 0.00 1211.90 0.00 0.00 -0.04 0.00 0.00 0.00
22 Self Weight Support 4 0.00 1084.25 0.00 0.00 -0.02 0.00 0.00 0.00
23 Self Weight Support 5 0.00 1084.25 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 23
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 23
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 23
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
154300000.00 8.40 -7048.65 -6199.90 -7048.65
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
158106000.00 3.85 -7804.06 -8037.37 -7804.06
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 2.04 -2652.65 -3099.95 -2652.65
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 23
Version: 1.13.1
5.2.2.1 Overview
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 23
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
Beam No. 4
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 23
Version: 1.13.1
Beam No. 5
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 23
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 23
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 23
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 23
Version: 1.13.1
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative(Cantilever) 1211.90 L/150 3.06 37.86
2 004-SLS Relative (Beam) 900.00 L/200 -0.03 0.00
3 004-SLS Relative(Cantilever) 1211.90 L/150 3.06 37.86
4 004-SLS Relative (Beam) 1084.25 L/200 -0.00 0.00
5 004-SLS Relative (Beam) 1084.25 L/200 -0.00 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 23
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-L2 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-L2 OC (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 2
Local Forces: 0.43 0.43 -3.20 0.00 -0.00 0.00
Resistance: 3.97 1.56 8.00 0.06
Equation: abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)
Utilization: 78.52 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Connector: MT-AB-LL2 45 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-LL2 45 OC (E)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: -1.09 0.00 0.01 -0.00 0.00 0.00
Resistance: 9.72 0.10 0.10 0.10 0.00 0.00
abs(Fx.ed/Fx.rd);abs(Fy.ed/Fy.rd);abs(Fz.ed/Fz.rd);abs(Mx.ed/Mx.rd);abs(My
Equation:
.ed/My.rd);abs(Mz.ed/Mz.rd)
Utilization: 11.20 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 23
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 23
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 23
Case-13
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 26
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 26
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-O2B OC MT-B-O2B OC (C)
2 - -190.75 0.00 461.90 MT-C-L2 OC MT-C-L2 OC (C)
3 - 709.25 0.00 461.90 MT-C-L2 OC MT-C-L2 OC (C)
4 2 709.25 0.00 -500.00 MT-B-O2B OC MT-B-O2B OC (C)
5 - 709.25 0.00 -19.05 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
6 3 709.25 480.95 -500.00 MT-AB A OC MT-AB A OC (C)
7 - -190.75 0.00 -19.05 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
8 4 -190.75 480.95 -500.00 MT-AB A OC MT-AB A OC (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 26
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
2 no no no no yes yes - - - - 0.001 0.001
2 no no no no yes yes - - - - 0.001 0.001
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 26
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2282213 2-hole Baseplate MT-B-O2B OC 2 4.14
11 2346396 Angle brace MT-AB A OC set adjustable 2 0.88
Quantity Weight
Position Item Number Description
[-] [kg]
9 2271519 Angle connector MT-C-L2 OC 2 0.52
10 2273585 Angle brace MT-AB-LL2 45 OC 2 1.11
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2273256 Hexagon bolt MT-TLB OC 22 0.55
7 2272082 Twist-Lock MT-TL M10 OC 22 0.77
8 2105870 Stud anchor HST3-R M12x115 40/20 8 0.81
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 26
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 250.00 0.00 0.00 -3.18 0.00 0.00 0.00
2 Design 2 650.00 0.00 0.00 -3.18 0.00 0.00 0.00
3 Seismic (+x) 2 250.00 0.04 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 2 250.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
5 Seismic (+x) 2 650.00 0.04 0.00 0.00 0.00 0.00 0.00
6 Seismic (-x) 2 650.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 26
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
21 Self Weight Support 1 0.00 961.90 0.00 0.00 -0.04 0.00 0.00 0.00
22 Self Weight Support 2 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
23 Self Weight Support 3 0.00 961.90 0.00 0.00 -0.04 0.00 0.00 0.00
24 Self Weight Support 4 0.00 680.17 0.00 0.00 -0.02 0.00 0.00 0.00
25 Self Weight Support 5 0.00 680.17 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 26
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 26
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 26
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
154300000.00 8.40 -7048.65 -6199.90 -7048.65
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
158106000.00 3.85 -7804.06 -8037.37 -7804.06
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 2.04 -2652.65 -3099.95 -2652.65
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 26
Version: 1.13.1
5.2.2.1 Overview
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 26
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
Beam No. 4
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 26
Version: 1.13.1
Beam No. 5
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 26
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 26
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 26
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 26
Version: 1.13.1
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 006-SLS Relative(Cantilever) 961.90 L/150 3.13 48.83
2 016-SLS Relative (Beam) 900.00 L/200 0.00 0.00
3 006-SLS Relative(Cantilever) 961.90 L/150 3.13 48.83
4 016-SLS Relative (Beam) 680.17 L/200 -0.00 0.00
5 016-SLS Relative (Beam) 680.17 L/200 -0.00 0.00
*006-SLS: SW + Wind (+x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * LC8
*016-SLS: SW + Live + Snow + Wind (-x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * 0.60 * LC9
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 26
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-L2 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-L2 OC (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 2
Local Forces: 0.43 0.43 -3.20 0.00 0.00 0.00
Resistance: 3.97 1.56 8.00 0.06
Equation: abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)
Utilization: 78.52 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Connector: MT-AB-LL2 45 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-LL2 45 OC (E)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: -1.42 0.00 0.01 -0.00 0.00 0.00
Resistance: 9.72 0.10 0.10 0.10 0.00 0.00
abs(Fx.ed/Fx.rd);abs(Fy.ed/Fy.rd);abs(Fz.ed/Fz.rd);abs(Mx.ed/Mx.rd);abs(My
Equation:
.ed/My.rd);abs(Mz.ed/Mz.rd)
Utilization: 14.65 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 26
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 26
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 26 / 26
Case-14
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 26
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 26
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-O2B OC MT-B-O2B OC (C)
2 - -190.75 0.00 861.90 MT-C-L2 OC MT-C-L2 OC (C)
3 - 309.25 0.00 861.90 MT-C-L2 OC MT-C-L2 OC (C)
4 2 309.25 0.00 -500.00 MT-B-O2B OC MT-B-O2B OC (C)
5 - 309.25 0.00 -19.05 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
6 3 309.25 480.95 -500.00 MT-AB A OC MT-AB A OC (C)
7 - -190.75 0.00 -19.05 MT-AB-LL2 45 OC MT-AB-LL2 45 OC (E)
8 4 -190.75 480.95 -500.00 MT-AB A OC MT-AB A OC (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 26
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
2 no no no no yes yes - - - - 0.001 0.001
2 no no no no yes yes - - - - 0.001 0.001
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 26
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2282213 2-hole Baseplate MT-B-O2B OC 2 4.14
11 2346396 Angle brace MT-AB A OC set adjustable 2 0.88
Quantity Weight
Position Item Number Description
[-] [kg]
9 2271519 Angle connector MT-C-L2 OC 2 0.52
10 2273585 Angle brace MT-AB-LL2 45 OC 2 1.11
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2273256 Hexagon bolt MT-TLB OC 22 0.55
7 2272082 Twist-Lock MT-TL M10 OC 22 0.77
8 2105870 Stud anchor HST3-R M12x115 40/20 8 0.81
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 26
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 250.00 0.00 0.00 -3.18 0.00 0.00 0.00
3 Seismic (+x) 2 250.00 0.04 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 2 250.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
9 Pipe 2 250.00 0.32 0.32 0.00 0.00 0.00 0.00
11 Wind (+x) 2 250.00 0.66 -0.00 -0.00 -0.00 -0.00 -0.00
12 Wind (-x) 2 250.00 -0.66 -0.00 -0.00 -0.00 -0.00 -0.00
13 Self Weight Support 1 0.00 0.00 0.00 -0.02 0.00 0.00 0.00
14 Self Weight Support 1 1361.90 0.00 0.00 -0.00 0.00 0.00 0.00
15 Self Weight Support 2 500.00 0.00 0.00 -0.00 0.00 0.00 0.00
16 Self Weight Support 3 1361.90 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 26
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
21 Self Weight Support 1 0.00 1361.90 0.00 0.00 -0.04 0.00 0.00 0.00
22 Self Weight Support 2 0.00 500.00 0.00 0.00 -0.02 0.00 0.00 0.00
23 Self Weight Support 3 0.00 1361.90 0.00 0.00 -0.04 0.00 0.00 0.00
24 Self Weight Support 4 0.00 680.17 0.00 0.00 -0.02 0.00 0.00 0.00
25 Self Weight Support 5 0.00 680.17 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 26
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 26
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 26
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
154300000.00 8.40 -7048.65 -6199.90 -7048.65
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 2.04 -2652.65 -3099.95 -2652.65
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 26
Version: 1.13.1
5.2.2.1 Overview
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 26
Version: 1.13.1
Beam No. 1
Beam No. 2
Beam No. 3
Beam No. 4
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 26
Version: 1.13.1
Beam No. 5
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 26
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 26
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 26
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 26
Version: 1.13.1
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 006-SLS Relative(Cantilever) 1361.90 L/150 6.63 73.01
2 016-SLS Relative (Beam) 500.00 L/200 0.00 0.00
3 006-SLS Relative(Cantilever) 1361.90 L/150 6.63 73.01
4 016-SLS Relative (Beam) 680.17 L/200 -0.00 0.00
5 016-SLS Relative (Beam) 680.17 L/200 -0.00 0.00
*006-SLS: SW + Wind (+x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * LC8
*016-SLS: SW + Live + Snow + Wind (-x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * 0.60 * LC9
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 26
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-L2 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-L2 OC (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 2
Local Forces: 0.22 0.22 -1.60 0.00 0.00 0.00
Resistance: 3.97 1.56 8.00 0.06
Equation: abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)
Utilization: 39.15 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Connector: MT-AB-LL2 45 OC
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-LL2 45 OC (E)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: -1.05 0.00 0.01 -0.00 0.00 0.00
Resistance: 9.72 0.10 0.10 0.10 0.00 0.00
abs(Fx.ed/Fx.rd);abs(Fy.ed/Fy.rd);abs(Fz.ed/Fz.rd);abs(Mx.ed/Mx.rd);abs(My
Equation:
.ed/My.rd);abs(Mz.ed/Mz.rd)
Utilization: 10.79 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 26
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 26
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 26 / 26
Case-15
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 26
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 26
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -190.75 0.00 -500.00 MT-B-GS T OC MT-B-GS T OC (C_MT-70)
2 - -190.75 0.00 1561.90 MT-C-GSP T OC MT-C-GSP T OC (C_D)
3 - 709.25 0.00 1561.90 MT-C-GSP T OC MT-C-GSP T OC (C_D)
4 2 709.25 0.00 -500.00 MT-B-GS T OC MT-B-GS T OC (C_MT-70)
5 - 709.25 0.00 530.95 MT-AB-G T OC MT-AB-G T OC (C_D)
6 3 709.25 1023.42 -492.46 MT-B-GS AB OC MT-B-GS AB OC (C)
7 - -190.75 0.00 530.95 MT-AB-G T OC MT-AB-G T OC (C_D)
8 4 -190.75 1023.41 -492.46 MT-B-GS AB OC MT-B-GS AB OC (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 26
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
4 no no no no yes yes - - - - 0.000 0.000
4 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
5 no no no no yes yes - - - - 0.000 0.000
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 26
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2272100 Baseplate MT-B-GS T OC 2 4.33
10 2332787 Baseplate MT-B-GS AB OC 2 3.30
Quantity Weight
Position Item Number Description
[-] [kg]
8 2272074 Connector MT-C-GSP T OC plate 4 1.73
9 2272116 Angle brace MT-AB-G T OC adjustable 4 1.39
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2272084 Thread forming bolt MT-TFB OC 44 1.25
7 2105870 Stud anchor HST3-R M12x115 40/20 4 0.41
11 2018429 Anchor rod HIT-Z-R M12x105 4 0.41
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 26
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 250.00 0.00 0.00 -3.18 0.00 0.00 0.00
2 Design 2 650.00 0.00 0.00 -3.18 0.00 0.00 0.00
3 Seismic (+x) 2 250.00 0.04 0.00 0.00 0.00 0.00 0.00
4 Seismic (-x) 2 250.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
5 Seismic (+x) 2 650.00 0.04 0.00 0.00 0.00 0.00 0.00
6 Seismic (-x) 2 650.00 -0.04 -0.00 -0.00 -0.00 -0.00 -0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 26
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
21 Self Weight Support 1 0.00 2061.90 0.00 0.00 -0.04 0.00 0.00 0.00
22 Self Weight Support 2 0.00 900.00 0.00 0.00 -0.04 0.00 0.00 0.00
23 Self Weight Support 3 0.00 2061.90 0.00 0.00 -0.04 0.00 0.00 0.00
24 Self Weight Support 4 0.00 1447.33 0.00 0.00 -0.04 0.00 0.00 0.00
25 Self Weight Support 5 0.00 1447.32 0.00 0.00 -0.04 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 26
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 26
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 26
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
2039000.00 7.82 -6349.48 -6349.48 -6349.48
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 26
Version: 1.13.1
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
Beam No. 1
Beam No. 2
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 26
Version: 1.13.1
Beam No. 3
Beam No. 4
Beam No. 5
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 26
Version: 1.13.1
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 26
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 26
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 26
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/150
☑Maximum Allowable Deflection (Cantilever)L/75
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 26
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 006-SLS Relative(Cantilever) 2061.90 L/75 16.49 59.96
2 016-SLS Relative (Beam) 900.00 L/150 0.00 0.00
3 006-SLS Relative(Cantilever) 2061.90 L/75 16.49 59.96
4 006-SLS Relative(Cantilever) 1447.33 L/75 7.51 38.92
5 006-SLS Relative(Cantilever) 1447.32 L/75 7.50 38.88
*006-SLS: SW + Wind (+x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * LC8
*016-SLS: SW + Live + Snow + Wind (-x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * 0.60 * LC9
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 26
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 26
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-GSP T OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GSP T OC (C_D)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -1.93 -0.49 0.93 -0.03 0.86 0.02
Resistance: 69.99 8.88 10.65 0.40 1.25 0.57
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 97.03 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
Combination
Connector: MT-AB-G T OC
Fx Fy Fz Mx My Mz
Connector variant: MT-AB-G T OC (C_D)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 5
Local Forces: -1.64 -0.03 0.00 -0.10 -0.00 0.00
Resistance: 32.99 6.44 1.83
Equation: (( Fx.ed^2 + Fy.ed^2 )^0.5)/Fx.rd + Fz.ed / Fz.rd+Mx.ed/Mx.rd
Utilization: 10.62 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 26
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 26
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 26 / 26
Case-16
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 25
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 25
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -215.00 0.00 -500.00 MT-B-O2 MT-B-O2 (C)
2 - -215.00 0.00 -222.25 MT-C-LL1 MT-C-LL1 (C)
3 - 733.50 0.00 -222.25 MT-C-LL1 MT-C-LL1 (C)
4 2 733.50 0.00 -500.00 MT-B-O2 MT-B-O2 (C)
1.3 Members
1.4 Connections
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
2 no no no no yes yes - - - - 0.001 0.001
2 no no no no yes yes - - - - 0.001 0.001
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 25
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
3 2272094 2-hole Baseplate MT-B-O2 2 2.05
Quantity Weight
Position Item Number Description
[-] [kg]
7 2272047 Angle connector MT-C-LL1 2 0.67
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
4 2273254 Hexagon bolt MT-TLB 8 0.20
5 2272080 Twist-Lock MT-TL M10 8 0.28
6 2105719 Stud anchor HST3 M12x115 40/20 4 0.40
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 25
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 275.00 0.00 0.00 -1.79 0.00 0.00 0.00
2 Design 2 673.50 0.00 0.00 -1.79 0.00 0.00 0.00
3 Wind (+x) 2 474.25 0.53 -0.00 -0.00 -0.00 -0.00 -0.00
4 Wind (-x) 2 474.25 -0.53 -0.00 -0.00 -0.00 -0.00 -0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 25
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
17 Self Weight Support 1 0.00 277.75 0.00 0.00 -0.02 0.00 0.00 0.00
18 Self Weight Support 2 0.00 948.50 0.00 0.00 -0.02 0.00 0.00 0.00
19 Self Weight Support 3 0.00 277.75 0.00 0.00 -0.02 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 25
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 25
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 25
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
38410000.00 4.08 -2652.65 -3099.95 -2652.65
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 25
Version: 1.13.1
*006b-ULS: SW_sup + Wind (+x). Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.50 * LC8
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Beam No. 1
Beam No. 2
Beam No. 3
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 25
Version: 1.13.1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 25
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 25
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 25
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 25
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 016-SLS Relative (Beam) 277.75 L/200 0.01 0.00
2 004-SLS Relative (Beam) 948.50 L/200 -2.90 61.05
3 016-SLS Relative (Beam) 277.75 L/200 -0.00 0.00
*016-SLS: SW + Live + Snow + Wind (-x). Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 1.00 * 0.60 * LC9
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 1.00 * LC2 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 25
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 25
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-LL1
Fx Fy Fz Mx My Mz
Connector variant: MT-C-LL1 (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -0.24 -0.24 -1.80 0.00 0.00 -0.00
Resistance: 8.20 1.24 8.06 0.03 0.19 0.03
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 44.93 % OK
Governing Load
1.35 * LC1 + 1.35 * LC2 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 25
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 25
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 25
Fixpoint Design A
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 21
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 21
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -15.75 0.00 -500.00 MT-B-GL O4 OC MT-B-GL O4 OC (C)
2 - -15.75 0.00 -122.61 MT-C-GL OC MT-C-GL OC (C_D)
3 - 634.25 0.00 -122.61 MT-C-GL OC MT-C-GL OC (C_D)
4 2 634.25 0.00 -500.00 MT-B-GL O4 OC MT-B-GL O4 OC (C)
1.3 Members
1.4 Connections
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 21
Version: 1.13.1
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 21
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
3 2272103 4-hole Baseplate MT-B-GL O4 OC 2 29.82
Quantity Weight
Position Item Number Description
[-] [kg]
6 2272066 Angle connector MT-C-GL OC 4 4.64
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
4 2272084 Thread forming bolt MT-TFB OC 80 2.28
5 2105876 Stud anchor HST3-R M16x135 35/15 8 1.74
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 21
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 75.00 0.00 19.17 -1.79 0.00 0.00 0.00
2 Design 2 575.00 0.00 19.17 -1.79 0.00 0.00 0.00
5 Seismic (+x) 2 75.00 0.02 -0.00 -0.00 -0.00 -0.00 -0.00
6 Seismic (-x) 2 75.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
7 Seismic (-x) 2 575.00 0.02 -0.00 -0.00 -0.00 -0.00 -0.00
8 Seismic (+x) 2 575.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
9 Self Weight Support 1 0.00 0.00 0.00 -0.15 0.00 0.00 0.00
10 Self Weight Support 1 377.39 0.00 0.00 -0.02 0.00 0.00 0.00
11 Self Weight Support 2 650.00 0.00 0.00 -0.02 0.00 0.00 0.00
12 Self Weight Support 3 377.39 0.00 0.00 -0.15 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 21
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
13 Self Weight Support 1 0.00 377.39 0.00 0.00 -0.09 0.00 0.00 0.00
14 Self Weight Support 2 0.00 650.00 0.00 0.00 -0.09 0.00 0.00 0.00
15 Self Weight Support 3 0.00 377.39 0.00 0.00 -0.09 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 21
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 21
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 21
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
15470000.00 17.95 -30169.60 -30169.60 -30169.60
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 21
Version: 1.13.1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Beam No. 1
Beam No. 2
Beam No. 3
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 21
Version: 1.13.1
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 21
Version: 1.13.1
Torsion around X
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 21
Version: 1.13.1
Moment around Y
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 21
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 21
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative (Beam) 377.39 L/200 0.00 0.00
2 004-SLS Relative (Beam) 650.00 L/200 -0.00 0.00
3 004-SLS Relative (Beam) 377.39 L/200 -0.00 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 21
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 21
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-GL OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GL OC (C_D)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -1.86 19.17 0.27 -0.39 -0.08 0.00
Resistance: 94.46 35.33 37.95 2.38 2.72 1.99
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 76.59 % OK
Governing Load
1.35 * LC1 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 21
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 21
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 21
Fixpoint Design E
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 23
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 23
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -15.75 0.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
2 - -15.75 0.00 610.00 MT-C-GL OC MT-C-GL OC (C_D)
3 - 634.25 0.00 610.00 MT-C-GL OC MT-C-GL OC (C_D)
4 2 634.25 0.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
5 3 -15.75 500.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
8 4 634.25 500.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
9 - 634.25 0.00 128.58 MT-C-GL OC MT-C-GL OC (C)
10 - 634.25 500.00 128.58 MT-C-GL OC MT-C-GL OC (C)
11 - -15.75 0.00 128.58 MT-C-GL OC MT-C-GL OC (C)
12 - -15.75 500.00 128.58 MT-C-GL OC MT-C-GL OC (C)
1.3 Members
1.4 Connections
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 23
Version: 1.13.1
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
6 no no no no yes yes - - - - 0.001 0.001
6 no no no no yes yes - - - - 0.001 0.001
7 no no no no yes yes - - - - 0.001 0.001
7 no no no no yes yes - - - - 0.001 0.001
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 23
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2272104 4-hole Baseplate MT-B-GXL O4 OC 4 68.13
Quantity Weight
Position Item Number Description
[-] [kg]
8 2272066 Angle connector MT-C-GL OC 8 9.29
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2272084 Thread forming bolt MT-TFB OC 184 5.24
7 2105876 Stud anchor HST3-R M16x135 35/15 16 3.49
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 23
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2 75.00 0.00 18.47 -1.79 0.00 0.00 0.00
2 Design 2 575.00 0.00 18.47 -1.79 0.00 0.00 0.00
5 Seismic (+x) 2 75.00 0.02 -0.00 -0.00 -0.00 -0.00 -0.00
6 Seismic (-x) 2 75.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
7 Seismic (-x) 2 575.00 0.02 -0.00 -0.00 -0.00 -0.00 -0.00
8 Seismic (+x) 2 575.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
9 Self Weight Support 1 0.00 0.00 0.00 -0.17 0.00 0.00 0.00
10 Self Weight Support 1 1110.00 0.00 0.00 -0.02 0.00 0.00 0.00
11 Self Weight Support 2 650.00 0.00 0.00 -0.02 0.00 0.00 0.00
12 Self Weight Support 3 1110.00 0.00 0.00 -0.17 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 23
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
19 Self Weight Support 1 0.00 1110.00 0.00 0.00 -0.15 0.00 0.00 0.00
20 Self Weight Support 2 0.00 650.00 0.00 0.00 -0.15 0.00 0.00 0.00
21 Self Weight Support 3 0.00 1110.00 0.00 0.00 -0.15 0.00 0.00 0.00
22 Self Weight Support 4 0.00 857.15 0.00 0.00 -0.15 0.00 0.00 0.00
23 Self Weight Support 5 0.00 857.15 0.00 0.00 -0.15 0.00 0.00 0.00
24 Self Weight Support 6 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
25 Self Weight Support 7 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 23
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 23
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 23
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
303000000.00 30.19 -65000.00 -52200.00 -65000.00
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 23
Version: 1.13.1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Beam No. 1
Beam No. 2
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 23
Version: 1.13.1
Beam No. 3
Beam No. 4
Beam No. 5
Beam No. 6
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 23
Version: 1.13.1
Beam No. 7
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 23
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 23
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 23
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 23
Version: 1.13.1
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative(Cantilever) 1110.00 L/150 -3.59 48.52
2 004-SLS Relative (Beam) 650.00 L/200 -0.09 0.00
3 004-SLS Relative(Cantilever) 1110.00 L/150 3.59 48.52
4 004-SLS Relative(Cantilever) 857.15 L/150 -1.75 30.60
5 004-SLS Relative(Cantilever) 857.15 L/150 1.75 30.60
6 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
7 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 23
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 23
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-GL OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GL OC (C_D)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 2
Local Forces: -1.89 -18.47 0.08 0.12 -0.06 -0.00
Resistance: 94.46 35.33 37.95 2.38 2.72 1.99
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 61.94 % OK
Governing Load
1.35 * LC1 + 1.00 * LC7
Combination
Connector: MT-C-GL OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GL OC (C)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 9
Local Forces: -18.58 0.00 -0.05 -0.00 -0.00 0.00
Resistance: 40.71 17.62 20.22 0.64 1.06 0.75
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 46.04 % OK
Governing Load
1.35 * LC1 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 23
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 23
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 23
Fixpoint Design G
Project: SA-13082-SF
Submitted by:
Date: 28/02/2024
Table of content
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 2 / 27
Version: 1.13.1
Support Details
Modular Support Spacing [mm] Undefined
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 3 / 27
Version: 1.13.1
Concrete
1.2 Nodes
X Y Z
No. No. Connector name Connector variant
[mm] [mm] [mm]
1 1 -15.75 0.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
2 - -15.75 0.00 783.00 MT-C-GL OC MT-C-GL OC (C_D)
3 - 634.25 0.00 783.00 MT-C-GL OC MT-C-GL OC (C_D)
4 2 634.25 0.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
5 3 -15.75 500.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
6 - -15.75 500.00 783.00 MT-C-GL OC MT-C-GL OC (C_D)
7 - 634.25 500.00 783.00 MT-C-GL OC MT-C-GL OC (C_D)
8 4 634.25 500.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
13 5 -15.75 1000.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
16 6 634.25 1000.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
18 7 634.25 -500.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
19 8 -15.75 -500.00 -500.00 MT-B-GXL O4 OC MT-B-GXL O4 OC (C)
21 - 634.25 -500.00 128.58 MT-C-GL A OC MT-C-GL A OC (C_D)
22 - 634.25 1000.00 128.58 MT-C-GL A OC MT-C-GL A OC (C_D)
23 - -15.75 -500.00 128.58 MT-C-GL A OC MT-C-GL A OC (C_D)
24 - -15.75 1000.00 128.58 MT-C-GL A OC MT-C-GL A OC (C_D)
9 - 634.25 0.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
10 - 634.25 500.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
11 - -15.75 0.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
12 - -15.75 500.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
9 - 634.25 0.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
10 - 634.25 500.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
11 - -15.75 0.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
12 - -15.75 500.00 128.58 MT-C-GL OC MT-C-GL OC (C_D)
1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 4 / 27
Version: 1.13.1
1.4 Connections
Spring Constants
Releases
Member Translational Rotational
No. Cu,x Cu,y Cu,z Cφx Cφy Cφz
Ux Uy Uz φx φy φz
[kN/m] [kN/m] [kN/m] [kNm/Rad] [kNm/Rad] [kNm/Rad]
13 no no no no yes yes - - - - 0.001 0.001
14 no no no no yes yes - - - - 0.001 0.001
15 no no no no yes yes - - - - 0.001 0.001
16 no no no no yes yes - - - - 0.001 0.001
13 no no no no yes yes - - - - 0.001 0.001
14 no no no no yes yes - - - - 0.001 0.001
15 no no no no yes yes - - - - 0.001 0.001
16 no no no no yes yes - - - - 0.001 0.001
1.7 Gliders
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 5 / 27
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 6 / 27
Version: 1.13.1
2 Part list
2.1 Members
Quantity Weight
Position Item Number Description
[-] [kg]
5 2272104 4-hole Baseplate MT-B-GXL O4 OC 8 136.25
Quantity Weight
Position Item Number Description
[-] [kg]
8 2272066 Angle connector MT-C-GL OC 24 27.87
9 2272069 Angle connector MT-C-GL A OC adjustable 8 9.21
2.4 Other
Quantity Weight
Position Item Number Description
[-] [kg]
6 2272084 Thread forming bolt MT-TFB OC 496 14.14
7 2105876 Stud anchor HST3-R M16x135 35/15 32 6.97
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 7 / 27
Version: 1.13.1
3 Load Types
3. Loads
Custom loads
Position Fx Fy Fz Mx My Mz
Load No. Load Type Members
[mm] [kN] [kN] [kN] [kNm] [kNm] [kNm]
1 Design 2, 8 75.00 0.00 26.54 -3.18 0.00 0.00 0.00
2 Design 2, 8 575.00 0.00 26.54 -3.18 0.00 0.00 0.00
5 Seismic (+x) 2 75.00 0.02 -0.00 -0.00 -0.00 -0.00 -0.00
6 Seismic (-x) 2 75.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
7 Seismic (-x) 2 575.00 0.02 -0.00 -0.00 -0.00 -0.00 -0.00
8 Seismic (+x) 2 575.00 -0.02 -0.00 -0.00 -0.00 -0.00 -0.00
9 Self Weight Support 1 0.00 0.00 0.00 -0.17 0.00 0.00 0.00
10 Self Weight Support 1 1283.00 0.00 0.00 -0.02 0.00 0.00 0.00
11 Self Weight Support 2 650.00 0.00 0.00 -0.02 0.00 0.00 0.00
12 Self Weight Support 3 1283.00 0.00 0.00 -0.17 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 8 / 27
Version: 1.13.1
Start End
Fx Fy Fz Mx My Mz
Load No. Load Type Members Position Position
[kN/m] [kN/m] [kN/m] [kNm/m] [kNm/m] [kNm/m]
[mm] [mm]
33 Self Weight Support 1 0.00 1283.00 0.00 0.00 -0.15 0.00 0.00 0.00
34 Self Weight Support 2 0.00 650.00 0.00 0.00 -0.15 0.00 0.00 0.00
35 Self Weight Support 3 0.00 1283.00 0.00 0.00 -0.15 0.00 0.00 0.00
36 Self Weight Support 4 0.00 1283.00 0.00 0.00 -0.15 0.00 0.00 0.00
37 Self Weight Support 5 0.00 1283.00 0.00 0.00 -0.15 0.00 0.00 0.00
38 Self Weight Support 6 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
39 Self Weight Support 7 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
40 Self Weight Support 8 0.00 650.00 0.00 0.00 -0.15 0.00 0.00 0.00
41 Self Weight Support 9 0.00 883.00 0.00 0.00 -0.15 0.00 0.00 0.00
42 Self Weight Support 10 0.00 883.00 0.00 0.00 -0.15 0.00 0.00 0.00
43 Self Weight Support 11 0.00 883.00 0.00 0.00 -0.15 0.00 0.00 0.00
44 Self Weight Support 12 0.00 883.00 0.00 0.00 -0.15 0.00 0.00 0.00
45 Self Weight Support 13 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
46 Self Weight Support 14 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
47 Self Weight Support 15 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
48 Self Weight Support 16 0.00 500.00 0.00 0.00 -0.15 0.00 0.00 0.00
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 9 / 27
Version: 1.13.1
4 Load Combinations
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 10 / 27
Version: 1.13.1
5 Results
5.1.3 Members
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 11 / 27
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 12 / 27
Version: 1.13.1
5.2 Members
Iω M Wy Wz Wy
[mm⁶] [kg/m] [mm³] [mm³] [mm³]
303000000.00 60.38 -65000.00 -52200.00 -65000.00
5.2.2.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 13 / 27
Version: 1.13.1
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Beam No. 1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 14 / 27
Version: 1.13.1
Beam No. 2
Beam No. 3
Beam No. 4
Beam No. 5
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 15 / 27
Version: 1.13.1
Beam No. 6
Beam No. 7
Beam No. 8
Beam No. 9
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 16 / 27
Version: 1.13.1
Beam No. 10
Beam No. 11
Beam No. 12
Beam No. 13
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 17 / 27
Version: 1.13.1
Beam No. 14
Beam No. 15
Beam No. 16
*004b-ULS: SW_sup + Design Loads. Respective Combination Equation: 1.35 * LC1 + 1.00 * LC7
Normal load
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 18 / 27
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 19 / 27
Version: 1.13.1
Torsion around X
Moment around Y
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 20 / 27
Version: 1.13.1
Moment around Z
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 21 / 27
Version: 1.13.1
Buckling ratio
Criteria
☑Maximum Allowable Deflection (Beam) L/200
☑Maximum Allowable Deflection (Cantilever)L/150
- Maximum Deflection (Absolute) -
☑No Deflection checks calculated for 1.50mm
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 22 / 27
Version: 1.13.1
Overview
Results
Reference
Member Max deflection Utilization
Load Combination number* Governing criteria Length Limit
No. [mm] [%]
[mm]
1 004-SLS Relative(Cantilever) 1283.00 L/150 -8.35 97.61
2 004-SLS Relative (Beam) 650.00 L/200 -0.05 0.00
3 004-SLS Relative(Cantilever) 1283.00 L/150 8.35 97.61
4 004-SLS Relative(Cantilever) 1283.00 L/150 -8.35 97.61
5 004-SLS Relative(Cantilever) 1283.00 L/150 8.35 97.61
6 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
7 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
8 004-SLS Relative (Beam) 650.00 L/200 0.05 0.00
9 004-SLS Relative(Cantilever) 883.00 L/150 -3.08 52.33
10 004-SLS Relative(Cantilever) 883.00 L/150 3.08 52.33
11 004-SLS Relative(Cantilever) 883.00 L/150 3.08 52.33
12 004-SLS Relative(Cantilever) 883.00 L/150 -3.08 52.33
13 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
14 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
15 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
16 004-SLS Relative (Beam) 500.00 L/200 -0.00 0.00
*004-SLS: SW + Design Loads. Respective Combination Equation: 1.00 * LC1 + 0.70 * LC7
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 23 / 27
Version: 1.13.1
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 24 / 27
Version: 1.13.1
5.3 Connectors
5.3.1 Overview
Connector: MT-C-GL OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GL OC (C_D)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 3
Local Forces: -3.28 26.54 0.12 -0.15 -0.10 0.00
Resistance: 94.46 35.33 37.95 2.38 2.72 1.99
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 89.16 % OK
Governing Load
1.35 * LC1 + 1.00 * LC7
Combination
Connector: MT-C-GL A OC
Fx Fy Fz Mx My Mz
Connector variant: MT-C-GL A OC (C_D)
[kN] [kN] [kN] [kNm] [kNm] [kNm]
Node No. : 21
Local Forces: 31.56 0.00 -0.05 0.00 -0.00 0.00
Resistance: 49.57 35.33 37.95 2.38 2.72 2.22
abs(Fx.ed/Fx.rd)+abs(Fy.ed/Fy.rd)+abs(Fz.ed/Fz.rd)+abs(Mx.ed/Mx.rd)+abs(
Equation:
My.ed/My.rd)+abs(Mz.ed/Mz.rd)
Utilization: 63.98 % OK
Governing Load
1.35 * LC1 + 1.00 * LC7
Combination
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 25 / 27
Version: 1.13.1
5.4 Bases
5.4.1 Overview
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 26 / 27
Version: 1.13.1
Any and all information and data contained in the Software concern solely the use of Hilti products and based on the principles, formulas and security
regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by
the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product.
The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole
responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for
having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior
to using them for your specific facility. The Software servers only as an aid to interpret norms and permits without any guarantee as to the absence of
errors, the correctness and relevance ot the results or suitability for a specific application.
You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular
backup of programs and, if applicable, carry out the updates of that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.
Data and results must be checked for agreement with existing conditions and for plausibility. Changes may be necessary.
Copyright (c) Hilti AG 2010, FL-9494 Schaan 27 / 27
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HST3 M16 hef1
Return period (service life in years): 50
Item number: 2114053 HST3 M16x115 15/-
Effective embedment depth: hef,opti = 68.0 mm (hef,limit = 84.0 mm), hnom = 81.0 mm
Material:
Evaluation Service Report: ETA 98/0001
Issued I Valid: 20/07/2023 | -
Proof: Design Method EN 1992-4, Mechanical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 12.0 mm
Anchor plate :
R lx x ly x t = 350.0 mm x 350.0 mm x 12.0 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: 2
cracked concrete, C25/30, fc,cyl = 25.00 N/mm ; h = 250.0 mm, User-defined partial material safety
factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting acc. to EN 1992-4, 7.2.1.7 (2) b) 2) present
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
Anchor forces are calculated based on the assumption of a rigid anchor plate.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s
y c · NRk,p
NEd £ NRd,p = EN 1992-4, Table 7.1
gM,p
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
41,616 41,616 102.0 204.0 25.00
Group anchor ID
1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)
0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
54.500 1.000 54.500 1.250 43.600 5.145
V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · NRk,c EN 1992-4, Eq. (7.39a)
0 A
NRk,c = NRk,c · c,N
0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
41,616 41,616 102.0 204.0 3.410 25.00
Group anchor ID
2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2
= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)
'
c1 = max (c1.5 , 1.5h , s 3 )
2,max 2,max
EN 1992-4, Eq. (7.50)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
a a
bN + bV £ 1.0
Concrete failure
a a
bN + bV £ 1.0
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
8 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HST3 M16 hef1
Profile: no profile Item number: 2114053 HST3 M16x115 15/-
Hole diameter in the fixture: df = 18.0 mm Maximum installation torque: 110 Nm
Plate thickness (input): 12.0 mm Hole diameter in the base material: 16.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 101.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 123.0 mm
Cleaning: No cleaning of the drilled hole is required
Hilti HST3 stud anchor with 68 mm embedment, M16 hef1, Steel galvanized, installation per ETA 98/0001
y
175.0 175.0
30.0
3 4
175.0
290.0
x
175.0
1 2
30.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4 OC Date: 28/02/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HST3 M12 hef1
Return period (service life in years): 50
Item number: 2113979 HST3 M12x95 20/-
Effective embedment depth: hef,opti = 50.0 mm (hef,limit = 69.0 mm), hnom = 60.0 mm
Material:
Evaluation Service Report: ETA 98/0001
Issued I Valid: 20/07/2023 | -
Proof: Design Method EN 1992-4, Mechanical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 12.0 mm
Anchor plate :
R lx x ly x t = 350.0 mm x 350.0 mm x 12.0 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: 2
cracked concrete, C25/30, fc,cyl = 25.00 N/mm ; h = 250.0 mm, User-defined partial material safety
factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting acc. to EN 1992-4, 7.2.1.7 (2) b) 2) present
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
Anchor forces are calculated based on the assumption of a rigid anchor plate.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s
y c · NRk,p
NEd £ NRd,p = EN 1992-4, Table 7.1
gM,p
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
22,500 22,500 75.0 150.0 25.00
Group anchor ID
1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)
0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
34.000 1.000 34.000 1.250 27.200 0.213
V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · NRk,c EN 1992-4, Eq. (7.39a)
0 A
NRk,c = NRk,c · c,N
0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
22,500 22,500 75.0 150.0 2.780 25.00
Group anchor ID
2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2
= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)
'
c1 = max (c1.5 , 1.5h , s 3 )
2,max 2,max
EN 1992-4, Eq. (7.50)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
a a
bN + bV £ 1.0
Concrete failure
a a
bN + bV £ 1.0
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
8 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HST3 M12 hef1
Profile: no profile Item number: 2113979 HST3 M12x95 20/-
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 60 Nm
Plate thickness (input): 12.0 mm Hole diameter in the base material: 12.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 80.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 100.0 mm
Cleaning: No cleaning of the drilled hole is required
Hilti HST3 stud anchor with 50 mm embedment, M12 hef1, Steel galvanized, installation per ETA 98/0001
y
175.0 175.0
30.0
3 4
175.0
290.0
x
175.0
1 2
30.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-GL O4C OC Date: 28/02/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
11
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
Specifier's comments:
1 Input data
Anchor type and diameter: HST3 M12 hef1
Return period (service life in years): 50
Item number: 2113978 HST3 M12x85 10/-
Effective embedment depth: hef,opti = 50.0 mm (hef,limit = 69.0 mm), hnom = 60.0 mm
Material:
Evaluation Service Report: ETA 98/0001
Issued I Valid: 20/07/2023 | -
Proof: Design Method EN 1992-4, Mechanical
Stand-off installation: eb = 0.0 mm (no stand-off); t = 8.0 mm
Anchor plate :
R lx x ly x t = 100.0 mm x 200.0 mm x 8.0 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: 2
cracked concrete, C25/30, fc,cyl = 25.00 N/mm ; h = 250.0 mm, User-defined partial material safety
factor gc = 1.500
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting acc. to EN 1992-4, 7.2.1.7 (2) b) 2) present
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
Compression
2
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 5.793 0.440 0.260 0.355
2 0.000 0.440 0.260 0.355 x
Anchor forces are calculated based on the assumption of a rigid anchor plate.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
N
NEd £ NRd,s = Rk,s EN 1992-4, Table 7.1
gM,s
y c · NRk,p
NEd £ NRd,p = EN 1992-4, Table 7.1
gM,p
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
N
NEd £ NRd,c = Rk,c EN 1992-4, Table 7.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eN,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] fc,cyl [N/mm ]
22,500 22,500 75.0 150.0 25.00
Group anchor ID
1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
V
VEd £ VRd,s = Rk,s EN 1992-4, Table 7.2
gM,s
0
VRk,s = k7 · VRk,s EN 1992-4, Eq. (7.35)
0
VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN]
34.000 1.000 34.000 1.250 27.200 0.440
V
VEd £ VRd,cp = Rk,cp EN 1992-4, Table 7.2
gM,c,p
VRk,cp = k8 · NRk,c EN 1992-4, Eq. (7.39a)
0 A
NRk,c = NRk,c · c,N
0
· y s,N · y re,N · y ec1,N · y ec2,N · y M,N EN 1992-4, Eq. (7.1)
Ac,N
0 1,5
NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2)
0
Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3)
c
y s,N = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.4)
ccr,N £
1
y ec1,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,1
scr,N )
1
y ec2,N = £ 1.00 EN 1992-4, Eq. (7.6)
1+ ( 2 · eV,2
scr,N )
y M,N =1 EN 1992-4, Eq. (7.7)
2 0 2 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ]
43,500 22,500 75.0 150.0 2.780 25.00
Group anchor ID
1, 2
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
V
VEd £ VRd,c = Rk,c EN 1992-4, Table 7.2
gM,c
0 Ac,V
VRk,c = kT · VRk,c · 0
· y s,V · y h,V · y a,V · y ec,V · y re,V EN 1992-4, Eq. (7.40)
Ac,V
0 a b 1,5
VRk,c = k9 · dnom · lf · √fck · c1 EN 1992-4, Eq. (7.41)
0,5
a = 0.1 · () lf
c1
EN 1992-4, Eq. (7.42)
0,2
= 0.1 · (
c )
d nom
b EN 1992-4, Eq. (7.43)
1
0 2
Ac,V = 4.5 · c1 EN 1992-4, Eq. (7.44)
c2
y s,V = 0.7 + 0.3 · 1.00 EN 1992-4, Eq. (7.45)
1.5 · c1 £
0,5
y h,V = (1.5h· c ) 1
³ 1.00 EN 1992-4, Eq. (7.46)
1
y ec,V = £ 1.00 EN 1992-4, Eq. (7.47)
1+ ( 2 · eV
3 · c1 )
y a,V = √(cos a ) + (10.5 · sin a )
V
2
V
2 ³ 1.00 EN 1992-4, Eq. (7.48)
'
c1 = max (c1.5 , 1.5h , s 3 )
2,max 2,max
EN 1992-4, Eq. (7.50)
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
a a
bN + bV £ 1.0
Concrete failure
a a
bN + bV £ 1.0
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
7 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A!
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters
of the clearance hole see section 6.2.2 of EN 1992-4!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete
cover of the edge reinforcement.
• Load transfer from supplementary reinforcement to the structural member shall be verified by the responsible structural engineer.
• With supplementary reinforcement and post-installed anchors, please ensure that in the jobsite the rebars are not drilled through.
• The characteristic bond resistances depend on the return period (service life in years): 50
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
8 Installation data
2 2
Anchor plate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and diameter: HST3 M12 hef1
Profile: no profile Item number: 2113978 HST3 M12x85 10/-
Hole diameter in the fixture: df = 14.0 mm Maximum installation torque: 60 Nm
Plate thickness (input): 8.0 mm Hole diameter in the base material: 12.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 80.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 100.0 mm
Cleaning: No cleaning of the drilled hole is required
Hilti HST3 stud anchor with 50 mm embedment, M12 hef1, Steel galvanized, installation per ETA 98/0001
y
50.0 50.0
30.0
2
100.0
140.0
x
100.0
1
30.0
50.0 50.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
10
Hilti PROFIS Engineering 3.0.91
www.hilti.de
Company: Page: 11
Address: Specifier:
Phone I Fax: | E-Mail:
Design: MT-B-O2B Date: 28/02/2024
Fastening point:
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan