You are on page 1of 1

CABLE SPECIFICATION 1/1

Model L−2E5 Ver2.9


Applications Audio Cable for Microphone, Line Canare Electric Co.,Ltd.

Physical Characteristics Dimensions Specifications Remarks


No.of Cond. 2 Pair
Conductor Structure mm/qty (mil/ ) A0.08/30 (3.15/ ) Annealed Copper
Nom.Cross Section Area m㎡ ( mil□) 0.15 (232.5) 26AWG
Outer Diameter mm ( mil) 0.51 (20.08)
Insulation Type XLPE Color:Blu & Wht
Thickness mm ( mil) 0.30 (11.81)
Outer Diameter mm ( Inch) 1.11 (0.044)
Pair/Quad Strand Pitch mm ( Inch) <= 18.0 (<=0.71) Filler Materials:Cotton
Wrap Tape Thickness mm ( mil) 0.03 (1.18)
Shield Type mm/piece/carr(mil/ ) TA0.10/ 8/16 (3.94/ ) Tinned Annealed Copper
Thickness mm ( mil) −
Coverage % >97
Jacket Type PVC Color:Blk,Gry,Grn
Thickness mm ( mil) 0.9 (35.43) Custom colors available.
Overall Diameter mm ( Inch) 4.6 (0.18) -20 -4
Brittle Temp. -50゚C(-58゚F)
Marking L-2E5 CANARE CABLE <Year code>
MADE IN JAPAN
Weight kg/100m(lbs/1000ft) 3.0 (20.2) -30
FALSE
Cable Cross Section

Jacket
Shield

1 2

Core Wrap Tape


Filler

Electrical Characteristics (Nominal) Dimensions Specifications Remarks


Rated Voltage V AC 60
Rated Current −
D.C.Resistance Conductor Ω/100m ( /1000ft) <= 12.7 (<=38.7)
Shield Conductor Ω/100m ( /1000ft) <= 2.2 (<=6.7)
Voltage Withstanding Min.Breakdown Voltage. VAC・1min 500
Insulation Resistance Between Conductors MΩ・km ( ・3000ft ) >= 1000 (>=1000)
Char.Impedance Ω at 10MHz −
Capacitance Between Conductors pF/m ( pF/ft ) −
Attenuation dB/100m ( /1000ft) −
Return Loss Ω at 10MHz −
Velocity of Propagation
Mechanical Characteristics (Nominal) Dimensions Specifications Remarks
Tensile Strength Jacket MPa >= 11.0
% >= 260

Environment Characteristics Specifications Remarks


Flame Retardance Flame must extinguish naturally Perform inclination test according to
within 60 seconds. JIS C 3005.

Note: Testing must be performed under standard conditions set down in "JIS C 60068-1 General Environmental Tesing
Rules(Electric/Electronics)."
Standard Conditions: Unless otherwise specified, all tests and measurements should be performed within a normal
temperature range of 15-35℃, a relative humidity of 25-75%, and an atmospheric pressure of 86-106kPa.