Vessel Gyrocompass Calibration

Project Title: Rig Move / DAGDA from OAK-S1A platform to SKM platform Model: GPS Trimble SPS461
Reference Hdg System
Project No: 2019-CA-POS-049 Vessel: DAGDA Rig Serial No: 5221K85547
Date/Time: 16/11/2019 12:00 to 13:00 Location: OAK-S1A Platform Model: OCTANS
Vessel Hdg System
Observed By: DNA Latitude: 04° 13' N Serial No: 3453-SX-GX-01-057
Checked By: DNA Purpose of Exercise Gyro Calibration

Gyro Comparison and C-O


119.5 2.00

119.0
1.75
True Heading (°)

118.5

C-O (°)
1.50

118.0

1.25
117.5

117.0 1.00
12:00 12:07 12:14 12:21 12:28 12:36 12:43 12:50 12:57
Time
Reference Heading
Vessel Heading
C-O

Vessel Heading System Start Time End Time Min Max C-O St Dev No of Observations No of Rejections % Rejected
OCTANS 12:00 13:00 117.12° 117.24° 1.36° 0.08 1797 0 0.00%