Professional Documents
Culture Documents
1TB02011-011C49-FFC-CHK-PH-0002
Document No - 1TB02011-011C49-FFC-CHK-PH-0002
Rev - C0
Page 1 of 2
Document Cover Page Document Ref. 1TB02011-011C49-FFC-CHK-PH-0002
Revision History
Revision Revision - Revision Approved
No. June-Date by by Description of Revision Status
Inspection Checklist for For Review
Rashad Domestic Water
C0 11-09-23 SIHJ Distribution Valves
Arab
Installation
Distribution
Name Title Department Date Issued
Page 2 of 2
TRIPPLE BAY ROSEWOOD HOTEL PROJECT
Checklist Description: Domestic Water Supply Valves Installation and Inspection ITP No: ITP-ME-0001
1. GENERAL
3. Valve Installation
Page 1 of 2
TRIPPLE BAY ROSEWOOD HOTEL PROJECT
Checklist Description: Domestic Water Supply Valves Installation and Inspection ITP No: ITP-ME-0001
3.7 Ensure Check Valves are installed for proper direction of flow.
4. THREADED VALVES
Install shutoff valve close to water main on each branch and riser
serving plumbing fixtures or equipment, on each water supply to
4.1 equipment, and on each water supply to plumbing fixtures that do
not have supply stops. Use ball or gate valves for piping NPS 2 (DN
50) and smaller
Ensure that the inlet and outlet threads are undamaged and free of
4.2
debris.
Ensure Butterfly or Gate valves are utilized for piping NPS 2-1/2
5.1
(DN 65) and larger.