250 250
400
400
#12, @200 C/C #12, @200 C/C
In remaining top 50% Height In remaining top 50% Height
ROAD TOP LEVEL
250 250
600
400 THK WALL 400 THK WALL
1500
NGL NGL
#16,@ 150 C/C #12, @100 C/C #12, @100 C/C #16,@ 150 C/C
Upto Bottom 50% Height above raft Upto Bottom 50% Height above raft
#8, @150 C/C #8, @150 C/C
BOTHFACES #10,@150 C/C #10,@150 C/C BOTHFACES
1200
400 #10,@100 C/C #10,@100 C/C 400
450 750 750 450
350
350
100 300 300 100
1600 1600
IMPORTANT NOTES :
1. STEEL GRADE = FE500 [TOR].
2. CONCRETE GRADE = M25.
STRUCTURAL DETAILS OF ROAD SIDE CANTILEVER RETAINING WALL 3. CLEAR COVER: WALLS = 30mm,
FOR MAX. 2.4M SOIL RETENTION 4. BASE SLAB = 50mm
5. LAP/DEVELOPMENT LENGTH = 50 X BAR DIA.
(VEHICLE SURCHARGE LOAD INCLUDED) (USE ALTERNATE STAGGERED LAPPING OF BARS)
6. SBC OF SOIL CONSIDERED = 250 kN/m2