003 No 2 IG Blower
As discussed please open up and clean, do u have spare impeller? If not pls raise req for
same.
BLOWER SIDE INSPECTION DOOR OPEN BLOWER IMPELLER INSPECTED FOUND PITTED AND
MOST OF IMPELLER VANES WASTED AND THIN DOWN, SAME NEED TO BE RENEWED.SHAFT,
IMPELLER AND BEARINGS AND OTHER PARTS REQ TO BE RAISED.
Please carry out trouble shooting problem with electrical or mechanical problem or
electronic controller.
Deck air compressor checked ,found belts and other electrical connection were
disconnected.work in progress to make it operational.
009-010 purifier
016- Elevator
Check for alarms on elevator panel and revert with trouble shooting.
To be checked。
STP
Engine room pipelines please plan to renew for LT cooler and other pipeline which cannot be
done during sailing。
Required oxygen and acetylene gases to carry out the job。
Deck:-
VRCS-
Please check all valves from local control which are not working from and check for
operation
Use portable hand pump and check which pressure the valve is opening.
Please change solenoid if spare is available, or change from any working valve.
Purge lines if required.
Bridge equipment
As noted from defect list hydraulic pipelines are in very bad shape, please raise requisition
so that it can be changed during the voyage.
For other pipelines pls send requisition if pipelines not available and also sufficient gas for
carrying out work
Hydraulic break not holding for winch? please make a list as these need to be overhauled.
Check the speed of the winches.
Check windlass hydraulic pump condition.