You are on page 1of 2

KONTROLNI PRORAČUN TEMELJA POLAZNE STANICE

ANALIZA OPTEREČENJA

MOTOR - REDUKTOR 520 kg

UŽETNJAČA 142 kg

NOSAČ POGONA T OSTALO 250 kg

G = 912kg = 8,95 KN
1

STUB, LJESTVE I OSTALO G = 685kg = 6,72 KN


2

Σ4 = 0
V = V1 + V2 = 8,95 + 6,72 = 15,67 KN
M1 = V1 * 2,00 + T * 3,65 = 8,95*2,00+29,44*3,65=125,36KNm
M1 na 2/3h ML= 125,36 * 2/3*1,85 = 154,6 KNm
ΣX = 0
L = 29,44 KN
KONTROLA NAPONA NA TLO

GB = (1,10x1,10x1,85+2,10x1,10x0,5)x 2300 = 7809 kg= 76,57 KN


Gz = 2,10x1,10x1,25x1800 = 5197kg = 50,98 KN
1, 75
Gzp = /1 ,10∗3 , 20+1 ,60∗3 , 20+1 ,10∗3 , 20∗1, 60∗3 , 70−1 , 10∗3 , 20∗1 ,75∗1
3
Gzp = 3617kg = 35,48KN

V = 76,57 + 50,98 + 35,48 + 15,67 = 178,70 KN

V ML 178 , 70 154 , 61
+ = ± =¿
Ϭtla = F W 3 , 20∗1, 10 1 , 10∗3 ,20
6
Ϭ1 = 50,77 + 82,37 = 134,14 = 0,133MPa

Ϭ2 = -31,60 = -0,031MPa

Na sonovu dobivenih momenata I stvarnih napona na tlo usvajamo tipski temelj polazne
stanice za koji se prilaže izvedbeni nacrt