DATA SHEET FOR PRESSURE GAUGE

Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (OCS) AT NADUA Datasheet Number
Code

DATA SHEET FOR PRESSURE GAUGE OIL-100-ND-DS-I-0822 A0 Sheet No.: 02 of 05

INDEX SHEET

SHEET No. TITLE


1 COVER SHEET
2 INDEX SHEET
3 REVISION SHEET
4 NOTES SHEET
5 DS - PG
Revision Index
CREATION OF SURFACE PRODUCTION
Rev
FACILITIES (OCS) AT NADUA Datasheet Number
Code

DATA SHEET FOR PRESSURE GAUGE OIL-100-ND-DS-I-0822 A0 Sheet No: 03 of 06

REVISION RECORD SHEET

REV No. PURPOSE LIST OF PAGES OF UPDATED / MODIFIED SECTIONS, IF ANY


A0 ISSUED FOR REVIEW FIRST ISSUE
CREATION OF SURFACE PRODUCTION FACILITIES (OCS)
Revision Index
AT NADUA Datasheet Number Rev Code

DATA SHEET FOR PRESSURE GAUGE OIL-100-ND-DS-I-0822 A0 Sheet No: 04 of 05

Notes:
1. Documentation required :- Calibration Certificate , Ingress Protection Certificate, Material Certificates to 3.1 as per EN 10204, Hydro test , Explosion proof & weather
proof certificate, Pressure test Procedure/Report , SIL 2 Certificate, Operating & Maintenance Instructions & Spare Parts List.
2. All instruments to be supplied with a SS 316 Name plate with Tag no. permanently inscribed. Tags shall be Permanently secured.
3. Bourdon tube gauges shall be tested in accordance with of BS EN 837-1.
4. The gauge shall be weather proof to IP 65 as per IEC 60529 / IS 13947, as minimum.
5. Dial markings and dial colour shall be as per IS 3624.
6. The pressure gauge shall have an over-range protection of at least 130% of maximum working pressure, as minimum.
7. Calibration and test certificate to be provided for each instrument.
8. Painting shall be Manufacturer standard suitable for Hazardous environment.
9. All pressure transmitters shall be provided with 2 valve Manifold and it is to be fitted, tested & supplied along with the Instrument.
10. Valve manifold shall have 1/2" NPT(F) connection on process, gauge and 1/4'' NPT(F) Connection on vent/ drain & Material shall be same as the element material.
11. Gauge construction shall ensure no leakage of process fluid to atmosphere.
12. Vendor to select the filling liquid which shall be compatible with the maximum process temperature.
13. Liquid filled damping shall be provided, suitable fluid to be selected according to the process fluid conditions.
14. Gauge shall be provided with Snubber whereever the service specified is pulsating type (i.e, Pump discharge etc.,) and the MOC shall be same as socket material.
TITLE ITEM/TAG No. DATA SHEET No.
DATA SHEET FOR PRESSURE GAUGE SEE BELOW TABLE OIL-100-ND-DS-I-0822
PROJECT DESCRIPTION PROJECT NO SHEET REV
CREATION OF SURFACE PRODUCTION FACILITIES (OCS) AT NADUA KIP-17039 05 OF 05 A0
MPC CONTRACTOR CLIENT CONTRACT No. REQUISITION No. SPECIFICATION No.
TBA - - -
CLIENT NAME REV No. BY DATE CKD DATE APP. DATE DESCRIPTION
OIL INDIA LIMITED A0 IMR 29-Nov-18 MV 29-Nov-18 MSR/ VSR 29-Nov-18 ISSUED FOR REVIEW
CLIENT'S REF
-
ORIGINATOR ORIG. DATE
IMR 04-Oct-18
UNITS: Pressure: kg/cm2 g Temp: °C Flow: Gas: MMSCFD Liquid: m3/hr

GENERAL
1. Type Local 16. Socket Material SS 316
2. Style Solid Front 17. Liquid Filled Yes
3. Mounting Direct 18. Fill Fluid Glycerin
4. Dial Size 150 mm (Note-6) 19. Process Connection 1/2" NPT(M)
5. Range Units Kg/cm2g 20. Connnection Location Bottom
6. Accuracy ± 1% of range 21. Enclosure Rating IP 65 (Min)
7. Repeatability Included in Accuracy 22. Press. GaugeManufacturer *
8. Hysteresis Included in Accuracy 23. Press. Gauge Model No. Refer Below
9. Ring Type Cam ring (Bayonet type) 24 Manifold Manufacturer *
10. Blowdown Protection Back 25. Manifold Model No. *
11. Element Type Bourdon Tube 26.
12. Diaphragm Seal Not Required 27.
13. Case Material SS 316 28.
14. Lens Material Lamited Safety Glass 29.
15. Element Material SS 316 30.

NOTES
1) For General notes refer Notes sheet.

Calibrated Design Flange


Operating Pressure Design Pressure Model Notes &
S.No. Tag Number Service Description P&ID Number Range Temp. Size/ Remarks
(Kg/cm2) (Kg/cm2) Number Options
Kg/cm2 g (°C) Rating

Effluent Water Storage


1 66-PI-6601 17039-ND-P-DW-0206-01 0 - 16 5 10 85 *
Tank (ND-ABJ-3450) outlet

Fire water Storage Tanks


2 71-PI-7266 17039-ND-P-DW-0217-01 TBA Atm.+Liquid Head FOW+0.07 80 *
(ND-ABJ-3110A/B) Inlet

* To be Provided By Vendor.