TOWER VERTICALITY TEST RESULT
(3-Legged Tower)
SITE ID SITE NAME TYPE OF TOWER / TOWER SUPPLIER INSTRUMENT USED
406114 3 leg- 40m tower Theodolite
I. HORIZONTALITY
Reading from top of tower baseplate : h
1 = ____________mm.
2=_______ mm g
3=_____ mm
f
II. VERTICALITY
e
SECTION A-B SECTION B-C
Tower
TOWER LAYS (mm.) TOWER LAYS (mm.)
Level
Left mm Left Right d
a
b -0.5836
c -0.1414 c
d 0.6141 -0.5313
e 0.4086 -0.6195
f -0.1801 -0.3866 b
g -0.2684 -0.4036
h -0.2130 -0.5707
i 0.3007 -0.5743
j 0.2768 -0.6942
k -0.2337 -0.6794
-0.6259 a
III. TOLERANCE
Tower Height 40 m
Horizontal Standard
=
3_5 mm
A
= 1
Verticality Standard = 26.67 mm 1/1500 X H
Horizontal Test Result = 2.0 mm
Max Verticality Test Result = 49.5 mm
2 3
B C
Verticality Check for SECTION A-B
Theodolite Theodolite Position
Tower Photo Base point ( B ) Tower Photo middle point ( D )
Tower Photo top point ( H )
Verticality Check for SECTION B-C
Theodolite Theodolite Position
Tower Photo Base point ( B ) Tower Photo middle point ( D )
Tower Photo top point ( H )
Horizontal check For Leg A
Horizontal check For Leg B
Horizontal check For Leg C
VENDOR REPRESENTATIVE STEP REPRESENTATIVE
NAME Tadesse Habtie NAME
DESIGNATION Mr. DESIGNATION
SIGNATURE SIGNATURE
DATE 22/07/2022 DATE
Pole / Tower Verticality Test
KSGM-CW-SSD0039-R1 Page 1 of 2 _x000D_ C1 - Public
Issued On: Nov 2014 #
TOWER VERTICALITY TEST RESULT
(3-Legged Tower)
SITE ID SITE NAME TYPE OF TOWER / TOWER SUPPLIER INSTRUMENT USED
I. HORIZONTALITY
Reading from top of tower baseplate : (use dumpy level to check the levels of each leg, the bench mark is the horizontal height of eyepiece)
A = 888 mm
B = 886 mm
C = 888 mm
Standard Difference = 3 mm
A-B = 2 mm Pass
B-C = 2 mm Pass
C-A = 0 mm Pass
II. VERTICALITY
SECTION B-C SECTION A-B
TOWER LAYS (°) TOWER LAYS (°)
Tower Final Deviation
Level Deviation Deviation Ratio
α-Theodolite Reading β-Theodolite Reading α-Theodolite Reading β-Theodolite Reading
Ratio Ratio
Degree Point Second Degree Point Second Degree Point Second Degree Point Second 2.000
1 a 0.000 0.000 0.000
2 b 0.000 88 19 18 0 0 0 0.000 0.000
3 c 0.000 85 35 57 0 0 17 -1.071 1.237
4 d 0 0 0 0 0 0 0.000 82 53 51 0 0 15 -0.584 0.674
5 e 78 2 30 0 0 0 0.000 80 16 9 0 0 5 -0.141 0.163
6 f 75 25 26 359 59 55 0.093 77 38 52 0 0 24 -0.531 0.567
1 g 72 53 16 359 59 21 0.614 75 6 1 0 0 34 -0.620 0.712
2 h 70 24 22 359 59 30 0.409 72 35 41 0 0 25 -0.387 0.460
3 i 68 0 48 0 0 15 -0.180 70 10 51 0 0 30 -0.404 0.598
4 j 65 41 38 0 0 25 -0.268 67 48 52 0 0 48 -0.571 0.857
5 k 63 24 21 0 0 22 -0.213 65 29 38 0 0 54 -0.574 0.815
6 l 61 16 3 359 59 26 0.301 63 18 25 0 1 12 -0.694 0.696
7 m 59 13 49 359 59 26 0.277 61 12 49 0 1 17 -0.679 0.683
8 n 57 15 33 0 0 31 -0.234 59 11 16 0 1 17 -0.626 0.889
9 o 55 55 15 0 0 36 -0.258 57 48 32 0 1 18 -0.601 0.881
10 p 54 31 44 0 0 42 -0.286 56 22 57 0 1 25 -0.620 0.926
11 q 53 15 2 0 0 57 -0.370 55 3 41 0 1 25 -0.590 0.968
12 0.000 0.000 0.000
19 0.000 0.000 0.000
20 0.000 0.000 0.000
21 0.000 0.000 0.000
22 0.000 0.000 0.000
23 0.000 0.000 0.000
24 0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
0.000 0.000 0.000
III. TOLERANCE
Mini Tower or SST
Tower Height = 40 m
1/1500 X H (height of tower in millimeter) = 80.0 mm Standard
Max Test Result = 49.5 mm Pass
VENDOR REPRESENTATIVE STEP REPRESENTATIVE
NAME Sisay Mengesha NAME
DESIGNATION DESIGNATION
SIGNATURE SIGNATURE
DATE 08/04/2022 DATE