You are on page 1of 6

WHEN ANATOMIC Dextile™ anatomical mesh

DESIGN MEETS The right balance of anatomic


shape, increased coverage size†,
REAL-WORLD NEEDS porosity and strength.1-5
IT’S JUST RIGHT. Dextile™ mesh is designed to be
just right for your needs.

A POLYPROPYLENE
INGUINAL HERNIA
SOLUTION

† Compared to Bard 3DMax™* and Bard 3DMax™* Light.


WHEN CONVENIENCE
AND CONFIDENCE MEET
RIGHT IN THE MIDDLE,
IT’S JUST RIGHT.
Our goal is to give real-world surgeons a real-world
solution that improves ease of handling while
improving anatomical compliance.

STRENGTH TRANSPARENCY SHAPE


MEETS MEETS MEETS
HANDLING3,5 POROSITY 2 COVERAGE1,4

THE RIGHT
BALANCE OF
RESEARCH AND
COLLABORATION.
Dextile™ anatomical mesh is a product of a
collaboration with more than 100 HCPs worldwide.
Clinician feedback helped us create this unique,
truly anatomical mesh to adapt with the contours
of the inguinal anatomy.1
THE RIGHT SHAPE.
THE RIGHT DESIGN.
A truly anatomical polypropylene mesh with a patented
3-D shape that conforms to contours of the inguinal region.1,6
Dextile™ anatomical mesh provides wide coverage of the
myopectineal orifice, minimizing the risk of recurrence.2,7
And with large pores for excellent tissue integration
and improved visualization2,5,8,9,† — it’s just right.

Sealed edge maintains


shape after trocar
passage 5,9-11

Unsealed inferior edge


improves anatomical
compliance 1,4,5

Large pore size for


excellent tissue
integration 2,8,9,†

† Animal data may not correlate with human clinical outcomes.


EVERY FEATURE
WORKING TOGETHER
TO MAKE HERNIA REPAIR
EASIER FOR THE SURGEON
AND MORE ADAPTABLE
TO THE BODY.

Inferior flap adapts to contoured


asymmetrical inguinal anatomy 1

3-D anatomic shape


for wide coverage of
myopectineal orifice 1,4,5

The medial edge


aligns with the
patient’s midline

Monofilament
polypropylene
Green letters facilitate textile
orientation toward
patient’s midline 1,10
A BALANCED
APPROACH
TO INGUINAL
HERNIA REPAIR.

Designed specifically for minimally invasive inguinal hernia repair, including conventional
TAPP and TEP, and TAPP robotic techniques. Dextile™ mesh has the right combination of
qualities for equal or better intraoperative handling compared to the competition.

DextileTM 3DMaxTM* 3DMaxTM * light


anatomical mesh

Ease of use 4,5,10,11,†,‡

Anatomical
coverage 4,5

Transparency 2

Density classification 12 Heavyweight: >90 g/m2 Heavyweight: >90 g/m2 Lightweight: < 50 g/m2

Pore size 2 (mm) Large pore: 1.1 × 1.6 Small pore: 0.9 × 0.7 Large pore: 2.4 × 0.7
2.0 × 1.3

† Based on cadaver lab testing involving twelve U.S. and EU surgeons with strong 3DMAX™* and 3DMAX™* Light experience.
‡ Ease of use includes trocar introduction, deployment and positioning.
ORDERING
INFORMATION

Dextile™ anatomical mesh

ITEM NUMBER DESCRIPTION DIMENSIONS SIZE

DXT1309AL Dextile™ anatomical mesh 13 × 9 cm Left X1 13 × 9 cm (5.1” × 3.5”) Medium

DXT1309AR Dextile™ anatomical mesh 13 × 9 cm Right X1 13 × 9 cm (5.1” × 3.5”) Medium

DXT1510AL Dextile™ anatomical mesh 15 × 10 cm Left X1 15 × 10 cm (5.9” × 3.9”) Large

DXT1510AR Dextile™ anatomical mesh 15 × 10 cm Right X1 15 × 10 cm (5.9” × 3.9”) Large

DXT1612AL Dextile™ anatomical mesh 16 × 12 cm Left X1 16 × 12 cm (6.3” × 4.7”) X-Large

DXT1612AR Dextile™ anatomical mesh 16 × 12 cm Right X1 16 × 12 cm (6.3” × 4.7”) X-Large

REFERENCES:
1. Based on internal test report #43008CR268. Design output file Merlin. February 2019.
2. Based on internal report #43008CR336, Support for marketing claims related to the Dextile™ anatomical mesh transparency. August 2019.
3. Based on internal test report#43008CR315, Dextile™ anatomical mesh vs 3DMax™* Light mesh: mesh physical and mechanical comparison. August 2019.
4. Based on internal report #43008CR339, Support for marketing claims related to surface of Dextile™ anatomical mesh vs. competitors. August 2019.
5. Based on internal report #Dextile™ anatomical mesh, Surgeon interview report. July 2019.
6. Based on Medtronic patent #US-20180318057-A1, Prosthesis for inguinal hernia repair. November 2018.
7. HerniaSurge Group. International guidelines for groin hernia management. Hernia. 2018 Feb;22(1):1-165.
8. Weyhe D, Cobb W, Lecuivre J, et al. Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage –
Systematic analysis of key parameters of meshes in a novel minipig hernia model. Int J Surg. 2015;22: 46–53. July 2015.
9. Based on Phycher report #IMP-Toxsys-1 month-PH-19-0218 final report. August 2019.
10. Based on internal report #43008CR316a, Evaluation of Dextile™ anatomical mesh through human cadaver lab-PRL design validation. July 2019
11. Based on internal report #43008CR326, Support for marketing claims related to Dextile™ anatomical mesh handling. August 2019.
12. Based on internal report #43008CR344, Support to marketing claim related to Dextile™ anatomical mesh ease of use vs Bard 3DMax™* light. August 2019.

IMPORTANT: Please refer to the package insert for complete instructions, contraindications, warnings and precautions.
© 2020 Medtronic. All rights reserved. Medtronic, Medtronic logo and Further, Together are trademarks of Medtronic.
™* Third party brands are trademarks of their respective owners. All other brands are trademarks of a Medtronic company.
20-cema-dextile-anatomical-mesh-brochure-4789094

medtronic.com/covidien/uk

You might also like