Service Bulletin

1000 Series 5
Fuel injection pumps with self vent feature January 1989

New CAV DPA and DPS fuel injection pumps which will automatically eliminate air from the pump have been
introduced on some engines. These pumps have a vent pipe (A1) fitted between the top of the pump and the
atomiser leak-off pipe. Vent screws are not fitted to these pumps and connections or plugs need not be
released to eliminate air from the pump.
To eliminate air from the fuel system
If the system or a component in the system has been drained:
1 Turn the start key to the 'R' position. If a manual stop control is fitted, ensure that it is in the 'run' position.
2 Operate the lever of the fuel lift pump slowly for approximately two minutes.
3 Operate the starter motor until the engine starts.
Continued

A CG L0322

1
Service Bulletin - 1000 Series 5 January 1989

If the engine has been stopped by air in the fuel system:


1 Ensure that there is sufficient fuel in the tank, or that the fuel or air leaks have been corrected.
2 If a manual stop control is fitted, ensure that it is in the run position.
3 Operate the starter motor until the engine starts.

End

Issued by Perkins Engines Company Ltd, Peterborough PE1 5NA, England.  Proprietary information of Perkins Engines Company Ltd
1989, all rights reserved. The information is correct at the time of print. This bulletin is for technical information only andcannot be used
as a basis for any claim including but not limited to warranty.