Professional Documents
Culture Documents
Training XWDM v1.2 CM6.75 (En)
Training XWDM v1.2 CM6.75 (En)
75
Handbook
Tutorial xWDM
Version: 1.2
Datum: 27-01-2017
ab CM6.75 Schulungshandbuch xWDM
Historie
Version Datum Autor Bemerkung
1.0 05.05.2014 Sabine Pradel Übernahme/Anpassung aus CM5.5
1.1 08.05.2014 Giulio Gaviraghi Überarbeitung /Erweiterungen CM 6.75
1.1 03.09.2014 Giulio Gaviraghi English translation
1.2 29.10.2014 Giulio Gaviraghi Typo corrections
1
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Index
1 General............................................................................................................................................ 4
1.1 Introduction ............................................................................................................................ 4
1.2 Contents of this tutorial .......................................................................................................... 4
1.3 Requirements .......................................................................................................................... 4
1.4 Tutorial net´s overview ........................................................................................................... 4
2 Generation of WDM types .............................................................................................................. 5
2.1 Definition of WDM Multiplexer .............................................................................................. 5
2.1.1 Schematic overview ........................................................................................................ 5
2.1.2 Definition in CM: FSP 3000 ............................................................................................. 5
2.2 Definition of WDM band width types ..................................................................................... 8
2.2.1 Generation of a CWDM type: CWDM x8K ...................................................................... 8
2.3 Definition of WDM cards and modules (SFP’s) ..................................................................... 12
2.3.1 Card: CWDM Band Splitter (CWDM-BS)........................................................................ 12
2.3.2 Card: CWDM A-Band Wave Splitter (A-Band-WS) ........................................................ 14
2.3.3 Card: CWDM-module(s) - SFP 1470 nm,…,SFP 1610 nm .............................................. 16
2.3.4 Card: CWDM-module(s) - SFP Client ............................................................................. 17
2.3.5 Card: registration card für SFP´s - WCA Aggregation ................................................... 18
3 Generating components ............................................................................................................... 23
3.1 Generation of WDM Multiplexer and cards through component window .......................... 23
4 Generating a mux internal connection ......................................................................................... 26
4.1 Connecting phys. cross-wiring BS-card (A-Band Port) and A-Band-WS card (A-Band Port) . 26
4.2 Connectiong Phys. path between A-Band-WS card (1470 nm port) and WCA aggregation
card (1470 nm). ................................................................................................................................. 28
5 Generate a C-WDM-connection between the devices ................................................................. 31
5.1 Phys. Connection between BS-cards (Network-Port) .......................................................... 31
5.2 Edit a WDM-Section .............................................................................................................. 32
6 Transmission of a STM TC over WDM ........................................................................................... 34
6.1 Redirect a STM connection over a WDM Channel 1470 mn. ............................................... 34
6.1.1 Generate a SDH-Mux-Type: SMA4-R2 .......................................................................... 35
6.1.2 SDH-card-Typs: OI622-2F erstellen ............................................................................... 36
6.2 Generate a SDH-Multiplexer ................................................................................................. 37
6.3 Create a physical connection between SDH and WDM devices ........................................... 37
6.4 Create a SDH-section and route it over WDM-Technique .................................................... 37
2
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
3
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
1 General
1.1 Introduction
The aim of this tutorial is to convey the related basic knowledge to all users, which perform data-
entry in ConnectMaster.
Doing this it´s possible to cover specific requirements and functionality in relationship with the
administration of WDM nets.
1.3 Requirements
A basic knowledge in ConnectMaster and as well as familiarity with SDH will be required in order to
conclude successfully this tutorial.
1470 nm 1470 nm
1490 nm
Loc_A A-Band
Loc_B 1490 nm
A-Band
Loc_C
150 nm 150 nm
Wave Splitter Band Splitter Band Splitter Wave Splitter Wave Splitter Band Splitter Band Splitter Wave Splitter
1610 nm 1610 nm
Client STM/IP/WDM 1490 nm 1490 nm 1490 nm 1490 nm 1490 nm 1490 nm Client STM/IP/WDM
A-Band A-Band A-Band A-Band
1510 nm 1510 nm
1530 nm 1530 nm
1550 nm 1550 nm
1570 nm 1570 nm
B-Band B-Band B-Band B-Band
1590 nm 1590 nm 1590 nm 1590 nm 1590 nm 1590 nm
1610 nm 1610 nm
4
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Tip In order to be able to have different device´s type in the category Mux, you can define a
subcategory under Component Category Subcategory.
Step 2 Within the details view of mux , click on the tab equipment template:
5
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 3.1 Please select the slot Nr. 1 and rename it by pressing the F2-key:
Step 3.2 Select slots 2-21 (please hold the shift-key, click on slot number 2 and then on slot number 21)
and call the text generator (either by pressing F2-key once again or by right clicking on with the
context menú) in oder to rename the slots:
6
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 4 Please activate the check-box „define component types only“ and “slot-usage” in the tab
Assembly/Equipment
7
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
If there are card types, which the mux can be equiped with, they can be added by clicking on
“+”:
Step 3 Please generate a CWDM-Typ with name: CWDM x8K clicking on the icon and set the
following proprieties:
8
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 4
After saving the new logical WDM channel, you can press the detail button ( ), in order to
modify names and number of channels:
9
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 5 Please generate the following WDM type, representing a bandwidth with 4 wdm channels:
A-Band:
B-Band:
Single Channel:
10
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Result:
11
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 1 Please generate a component of the category „card“ with name: CWDM-BS and set the
following basic properties:
Step 2 After you generated the card type, please set the properties of the card´s points, as it´s shown
down here:
12
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 4 The explanation of the automatic connection´s „logic“ is achieved through the definition of
preconnect.
13
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 5 Now please assign this card to the multiplexer, where the card is allowed to be inserted:
14
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
You can multi-select items pressing ctrl and selecting the A-Band rows at the same time.
15
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 5 Now please assign this card to the multiplexer, where the card is allowed to be inserted:
Task Generate a card named B-Band-Splitter (B-Band-WS) similar to the A-Band Wave Splitter,
previously generated.
16
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Task
Please generate further SFPs (1490nm-1610nm) by duplicating ( ) the type and then
matching the points and the name of the ports.
17
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
The capacity check is deactivated (no usage check), so that the allocation of different
techniques (SDH/ETH) and band width could be connected over the client port.
18
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
19
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
20
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 3.3 Please define the element type for slot „client“
Step 3.4 Please activate the slot check („defined component types only“)
21
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
You can define preconnection for pluggable modules (SFP), which haven´t yet been
plugged, by activating the option „generic“.
Step 5 Please assign the element type to the mux, where it allowed to be plugged.
22
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
3 Generating components
3.1 Generation of WDM Multiplexer and cards through component window
Task Generate a WDM.01 component (category MUX) and component type: FSP 3000 at location
Loc_A.
23
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 3 Now please click on the mux´s detail and select the tab „Assembly“ in order to plug the card
in.
Step 4 Now choose please a slot and plug in the cards: right-click on the slot you´ve just selected and
click on “create and insert new component”.
Step 5 Please now plug-in the SFP in WCA Aggregation card: SFP-Client and SFP 1470 nm (you can
select the cards via context menu and then clicking on detail).
24
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
25
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Task Connection between BS-card (A-band port) and A-band-WS card (A-Band Port).
Step 2 Please select the connecting points, which have to be cross-wired together …
26
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 3
Please proceed to cross-wire the points by clicking on the icon
Please note that as soon as the cross-wiring is created, a logical WDM-path is going to be
created by ConnectMaster in the column “usage” and it highlighted in pink.
27
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
4.2 Connectiong Phys. path between A-Band-WS card (1470 nm port) and
WCA aggregation card (1470 nm).
Overview graphical representation:
Task Please connect the A-band-WS card (1470 nm) and WCA aggregation card (1470 nm).
Step 3
Please cross-wire clicking on the icon …
Step 4 The WDM-device WDM.02 in LocB can be generated either manually (as described in the
paragraph 4, 4.1 and 4.2) and then equipped and internally cross-wired or duplicating it
(using copy/paste) directly in LocB. Here we go for the second way, copying and pasting the
device and its internal connections.
28
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Please allow ConnectMastser to copy the internal connections as well clicling “yes” in the the
pop up window.
Step 4.3 Now please rename the mux in LocB as WDM.02 and possibly “move” the cards:
29
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
30
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Task Please connect physical paths between BS-Cards (Network-Port) of location Loc_A/WDM.01
to LOC_B/WDM.02 mux.
LocA
LocB
31
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Result
Tip As soon as two network ports are connected one to each other, ConnectMaster generate a
WDM section (according component type´s settings – see card : 1.3.1 CWDM Band Spliter)
32
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Detail Now you can rename the path typing in the field „name“:
Structur
33
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Task Redirecting a STM utilizable container from Loc_A to Loc_C over a WDM network.
graphical representation:
Tip If two SDH ports are cross-connected over a WDM-line, ConnectMaster notices this
operation automatically.
A STM utilizable container is automatically connected and routed over the WDM-line.
34
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 1 Generate a component of category mux with the name: SMA4-R2 and set the
following values
Tip You can distinguish mux devices creating different subcategories in the library:
under Component->Category-> Subcategory
Step 2 Please define the attributes of the mux type within the detail view and then click
on the tab “equipment template”:
35
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
36
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Result
37
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Step 2 Select the port 1 of card „OI622-2F“ and create a new TC ( transport container) clicking on the icon
Step 3 Based on the preconnection of cards types and on the mux´s internal connection the routing of SDH-
Section is defined, which is why the SDH-port on the other side can be automatically identified and
accepted:
38
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
Result
Routing-path On overview about the routing-path of the SDH-signal can be obtained opening the
context menu (right click on the SDH-signal you just defined) and selecting “detail”. The
please move to the tab “routing table”.
39
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM
40
© 2013 Dynamic Design GmbH