You are on page 1of 41

ConnectMaster 6.

75
Handbook

Tutorial xWDM

Version: 1.2
Datum: 27-01-2017
ab CM6.75 Schulungshandbuch xWDM

Historie
Version Datum Autor Bemerkung
1.0 05.05.2014 Sabine Pradel Übernahme/Anpassung aus CM5.5
1.1 08.05.2014 Giulio Gaviraghi Überarbeitung /Erweiterungen CM 6.75
1.1 03.09.2014 Giulio Gaviraghi English translation
1.2 29.10.2014 Giulio Gaviraghi Typo corrections

1
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Index
1 General............................................................................................................................................ 4
1.1 Introduction ............................................................................................................................ 4
1.2 Contents of this tutorial .......................................................................................................... 4
1.3 Requirements .......................................................................................................................... 4
1.4 Tutorial net´s overview ........................................................................................................... 4
2 Generation of WDM types .............................................................................................................. 5
2.1 Definition of WDM Multiplexer .............................................................................................. 5
2.1.1 Schematic overview ........................................................................................................ 5
2.1.2 Definition in CM: FSP 3000 ............................................................................................. 5
2.2 Definition of WDM band width types ..................................................................................... 8
2.2.1 Generation of a CWDM type: CWDM x8K ...................................................................... 8
2.3 Definition of WDM cards and modules (SFP’s) ..................................................................... 12
2.3.1 Card: CWDM Band Splitter (CWDM-BS)........................................................................ 12
2.3.2 Card: CWDM A-Band Wave Splitter (A-Band-WS) ........................................................ 14
2.3.3 Card: CWDM-module(s) - SFP 1470 nm,…,SFP 1610 nm .............................................. 16
2.3.4 Card: CWDM-module(s) - SFP Client ............................................................................. 17
2.3.5 Card: registration card für SFP´s - WCA Aggregation ................................................... 18
3 Generating components ............................................................................................................... 23
3.1 Generation of WDM Multiplexer and cards through component window .......................... 23
4 Generating a mux internal connection ......................................................................................... 26
4.1 Connecting phys. cross-wiring BS-card (A-Band Port) and A-Band-WS card (A-Band Port) . 26
4.2 Connectiong Phys. path between A-Band-WS card (1470 nm port) and WCA aggregation
card (1470 nm). ................................................................................................................................. 28
5 Generate a C-WDM-connection between the devices ................................................................. 31
5.1 Phys. Connection between BS-cards (Network-Port) .......................................................... 31
5.2 Edit a WDM-Section .............................................................................................................. 32
6 Transmission of a STM TC over WDM ........................................................................................... 34
6.1 Redirect a STM connection over a WDM Channel 1470 mn. ............................................... 34
6.1.1 Generate a SDH-Mux-Type: SMA4-R2 .......................................................................... 35
6.1.2 SDH-card-Typs: OI622-2F erstellen ............................................................................... 36
6.2 Generate a SDH-Multiplexer ................................................................................................. 37
6.3 Create a physical connection between SDH and WDM devices ........................................... 37
6.4 Create a SDH-section and route it over WDM-Technique .................................................... 37

2
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

3
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

1 General
1.1 Introduction
The aim of this tutorial is to convey the related basic knowledge to all users, which perform data-
entry in ConnectMaster.

1.2 Contents of this tutorial


The following functions are going to described in this tutorial:
 Generation of WDM-typ components
 Generation of WDM-device-types
 Generation and design of a WDM-backbone
 Interconnection of WDM Channel
 connection of customer connection

Doing this it´s possible to cover specific requirements and functionality in relationship with the
administration of WDM nets.

1.3 Requirements
A basic knowledge in ConnectMaster and as well as familiarity with SDH will be required in order to
conclude successfully this tutorial.

1.4 Tutorial net´s overview


1470 nm CWDM Kanal
A-B B-C

1470 nm 1470 nm
1490 nm
Loc_A A-Band
Loc_B 1490 nm

A-Band
Loc_C
150 nm 150 nm
Wave Splitter Band Splitter Band Splitter Wave Splitter Wave Splitter Band Splitter Band Splitter Wave Splitter
1610 nm 1610 nm

1470 nm 1470 nm 1470 nm 1470 nm


Aggregation Aggregation Aggregation
1470 nm 1470 nm 1470 nm 1470 nm
1470 nm 1470 nm

Client STM/IP/WDM 1490 nm 1490 nm 1490 nm 1490 nm 1490 nm 1490 nm Client STM/IP/WDM
A-Band A-Band A-Band A-Band
1510 nm 1510 nm

1530 nm 1530 nm

A-Band Network Network A-Band A-Band Network Network A-Band

1550 nm 1550 nm

1570 nm 1570 nm
B-Band B-Band B-Band B-Band
1590 nm 1590 nm 1590 nm 1590 nm 1590 nm 1590 nm

1610 nm 1610 nm

1610 nm 1610 nm 1610 nm 1610 nm

4
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

2 Generation of WDM types


2.1 Definition of WDM Multiplexer
2.1.1 Schematic overview
definition ADVA - Fiber Service Plattform 3000 (FSP 3000)

2.1.2 Definition in CM: FSP 3000


Step 1 Please generate a component type (Network Inventoy->Component Types) of category mux with
name FSP 3000 and then entry the following parameters:

Tip In order to be able to have different device´s type in the category Mux, you can define a
subcategory under Component Category Subcategory.

Step 2 Within the details view of mux , click on the tab equipment template:

5
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3 Please match the name of slots as following :


Slot 1: A/B, Slots 2-21: 01-20

Step 3.1 Please select the slot Nr. 1 and rename it by pressing the F2-key:

You can finish to rename the slot pressing enter.

Step 3.2 Select slots 2-21 (please hold the shift-key, click on slot number 2 and then on slot number 21)
and call the text generator (either by pressing F2-key once again or by right clicking on with the
context menú) in oder to rename the slots:

6
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3.3 You can use the text generator as following:


a) Select the “numeric” in the first drop down menu
b) Leave the range unchanged (it is automatically counted)
c) Set to the digit to maximun length and to “2” the number of character in the string
d) Eventually press on the icon to generate the number and confirm by clicking on “ok”

Step 4 Please activate the check-box „define component types only“ and “slot-usage” in the tab
Assembly/Equipment

7
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

If there are card types, which the mux can be equiped with, they can be added by clicking on
“+”:

2.2 Definition of WDM band width types


2.2.1 Generation of a CWDM type: CWDM x8K
Step 1 The WDM types can be defined under Library-> Log. Paths ->WDM-Types definiert werden.

Step 2 Switch to norm: CWDM

Step 3 Please generate a CWDM-Typ with name: CWDM x8K clicking on the icon and set the
following proprieties:

8
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 4
After saving the new logical WDM channel, you can press the detail button ( ), in order to
modify names and number of channels:

9
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 5 Please generate the following WDM type, representing a bandwidth with 4 wdm channels:

A-Band:

B-Band:

Single Channel:

10
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Result:

11
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

2.3 Definition of WDM cards and modules (SFP’s)


2.3.1 Card: CWDM Band Splitter (CWDM-BS)

Step 1 Please generate a component of the category „card“ with name: CWDM-BS and set the
following basic properties:

Step 2 After you generated the card type, please set the properties of the card´s points, as it´s shown
down here:

12
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3 Please modify the ports´ name and capacity as following:

Step 4 The explanation of the automatic connection´s „logic“ is achieved through the definition of
preconnect.

13
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 5 Now please assign this card to the multiplexer, where the card is allowed to be inserted:

2.3.2 Card: CWDM A-Band Wave Splitter (A-Band-WS)


Step 1 Generate a component type of the category card with the name: A-Band-WS and set the
following values:

Step 2 Definition of points ´ properties:

14
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3 Definition of ports´ properties:

Step 4 Definition of preconnect:

You can multi-select items pressing ctrl and selecting the A-Band rows at the same time.

15
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 5 Now please assign this card to the multiplexer, where the card is allowed to be inserted:

Task Generate a card named B-Band-Splitter (B-Band-WS) similar to the A-Band Wave Splitter,
previously generated.

2.3.3 Card: CWDM-module(s) - SFP 1470 nm,…,SFP 1610 nm


Step 1 Generate a component type of category card with the name: SFP 1470nm and set the following
values:

16
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 2 Please define the points´ properties as following:

Task
Please generate further SFPs (1490nm-1610nm) by duplicating ( ) the type and then
matching the points and the name of the ports.

2.3.4 Card: CWDM-module(s) - SFP Client


Step 1 Please generate a component type of the category card with the name: SFP Client and set
following values:

17
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 2 Please define points and ports´ properties

The capacity check is deactivated (no usage check), so that the allocation of different
techniques (SDH/ETH) and band width could be connected over the client port.

2.3.5 Card: registration card für SFP´s - WCA Aggregation


Step 1 Please generate a component of the category card with the name: WCA Aggregation and
set the following values:

18
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 2 Please match the slots´ names

19
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3 Define the equipment´s rules

Step 3.1 Call the assignment of element types

Step 3.2 Please allocate the assigned element types

20
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3.3 Please define the element type for slot „client“

Step 3.4 Please activate the slot check („defined component types only“)

21
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 4 Define the preconnect as following

You can define preconnection for pluggable modules (SFP), which haven´t yet been
plugged, by activating the option „generic“.

Tip You can find more information about preconnect in annex-1.

Step 5 Please assign the element type to the mux, where it allowed to be plugged.

22
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

3 Generating components
3.1 Generation of WDM Multiplexer and cards through component window
Task Generate a WDM.01 component (category MUX) and component type: FSP 3000 at location
Loc_A.

Step 1 generate a component type from explorer:

Step 2 Please insert the following values:

 Assign the name manually


 Choose the component type from the drop-down list

23
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3 Now please click on the mux´s detail and select the tab „Assembly“ in order to plug the card
in.

Step 4 Now choose please a slot and plug in the cards: right-click on the slot you´ve just selected and
click on “create and insert new component”.

Step 5 Please now plug-in the SFP in WCA Aggregation card: SFP-Client and SFP 1470 nm (you can
select the cards via context menu and then clicking on detail).

24
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Don´t forget to save the changes you´ve just made!


Now you´ve generated the component successfully.

25
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

4 Generating a mux internal connection


4.1 Connecting phys. cross-wiring BS-card (A-Band Port) and A-Band-WS card
(A-Band Port)

Overview graphical representation:

Task Connection between BS-card (A-band port) and A-band-WS card (A-Band Port).

Step 1 Please open the connection sheet of both cards:


 5: CWDM-BS
 8: A-Band-WS

Step 2 Please select the connecting points, which have to be cross-wired together …

26
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 3
Please proceed to cross-wire the points by clicking on the icon

Please note that as soon as the cross-wiring is created, a logical WDM-path is going to be
created by ConnectMaster in the column “usage” and it highlighted in pink.

27
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

4.2 Connectiong Phys. path between A-Band-WS card (1470 nm port) and
WCA aggregation card (1470 nm).
Overview graphical representation:

Task Please connect the A-band-WS card (1470 nm) and WCA aggregation card (1470 nm).

Step 1 Open the connection sheets of both cards


 8: A-Band-WS
 9: WCA Aggregation

Step 2 Select the connecting points, which have to be cross-wired …

Step 3
Please cross-wire clicking on the icon …

Step 4 The WDM-device WDM.02 in LocB can be generated either manually (as described in the
paragraph 4, 4.1 and 4.2) and then equipped and internally cross-wired or duplicating it
(using copy/paste) directly in LocB. Here we go for the second way, copying and pasting the
device and its internal connections.

28
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 4.1 Please copy the mux WDM.01

Step 4.2 Paste mux WDM.01 in LocB

Please allow ConnectMastser to copy the internal connections as well clicling “yes” in the the
pop up window.

Step 4.3 Now please rename the mux in LocB as WDM.02 and possibly “move” the cards:

29
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

30
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

5 Generate a C-WDM-connection between the


devices

5.1 Phys. Connection between BS-cards (Network-Port)

Overview Grafical representation:

Task Please connect physical paths between BS-Cards (Network-Port) of location Loc_A/WDM.01
to LOC_B/WDM.02 mux.

LocA

LocB

31
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Result

Tip As soon as two network ports are connected one to each other, ConnectMaster generate a
WDM section (according component type´s settings – see card : 1.3.1 CWDM Band Spliter)

5.2 Edit a WDM-Section


Call Eventually you can rename the generated WDM-section „BS<->BS“(see card type definition
„CWDM-BS“). To do this, please right click on the device, open the connecting sheets and then
right-click once again on column “usage” and select “detail” from this context menu.

32
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Detail Now you can rename the path typing in the field „name“:

Structur

Task a) Generate a WDM.03 in LOcC


b) Expand WDM.02 to
 CWDM-BS
 A-Band
 SFP 1490nm (slot: West) in WCA Aggregation
c) Delete SFPs-client in WCA-aggregation card
d) Connect physical paths between BS-Karten (Network-Port) of location Loc_B
WDM.02 Mux to Loc_C WDM.03 mux.

33
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

6 Transmission of a STM TC over WDM


6.1 Redirect a STM connection over a WDM Channel 1470 mn.

Task Redirecting a STM utilizable container from Loc_A to Loc_C over a WDM network.

graphical representation:

Tip If two SDH ports are cross-connected over a WDM-line, ConnectMaster notices this
operation automatically.
A STM utilizable container is automatically connected and routed over the WDM-line.

34
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

6.1.1 Generate a SDH-Mux-Type: SMA4-R2

Step 1 Generate a component of category mux with the name: SMA4-R2 and set the
following values

Tip You can distinguish mux devices creating different subcategories in the library:
under Component->Category-> Subcategory

Step 2 Please define the attributes of the mux type within the detail view and then click
on the tab “equipment template”:

Step 3 Now please match the name of the slots as following:


rows 1:401-417, rows 2:501-517

35
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

6.1.2 SDH-card-Typs: OI622-2F erstellen


Step 1 Please generate a component type of the category card with the name: OI622-2F and set the
following values:

Step 2 Now please define the points´ properties

Step 3 Definition of the points´ properties

36
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

6.2 Generate a SDH-Multiplexer


Task Please generate both in location LocA and LocC a SDH-Mux of type “SMA4-R” and please equip them
respectively with a card type „OI622-2F“ in slot 508.

Result

6.3 Create a physical connection between SDH and WDM devices


Task Create respectively a physical connection between SDH.01 x 508:OI622-2F Port1 and the Client-Port
on the WCA-aggregation-card.

6.4 Create a SDH-section and route it over WDM-Technique


Step 1 Select the detail of SDH.01 selecting the tab mux usage

37
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Step 2 Select the port 1 of card „OI622-2F“ and create a new TC ( transport container) clicking on the icon

Step 3 Based on the preconnection of cards types and on the mux´s internal connection the routing of SDH-
Section is defined, which is why the SDH-port on the other side can be automatically identified and
accepted:

38
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Result

Routing-path On overview about the routing-path of the SDH-signal can be obtained opening the
context menu (right click on the SDH-signal you just defined) and selecting “detail”. The
please move to the tab “routing table”.

39
© 2013 Dynamic Design GmbH
ab CM6.75 Schulungshandbuch xWDM

Infos about Top parent view


the Structur

40
© 2013 Dynamic Design GmbH

You might also like