GJ-20091007 Processor reinitializing – MFU Board problem

Page 1/1 Valid for following product(s):

Product code Description Affected Serial Numbers*

93778 InterPlater 85P HDX 93778-1068 => 93778-1072


93779 InterPlater 125P HDX 93779-1009 => 93779-1010

* Both serial numbers included

Issue(s)/symptom(s):
Unfortunately a batch of our Motor Filter Units boards (MFU, revision D)
has been produced with a failure in the firmware which may cause the
processor to unintentionally reinitialize and trigger the error message
“MFU Lost” in the processor History list.
The failure in the firmware is causing the Central Processing Unit (CPU)
on the MFU board to be sensitive to heat applied which causes the
communication between the boards to slow down which again eventually
causes the processor to reinitialize. The symptom will appear as “MFU
Lost” in the processor History list.
The issue is believed to potentially happen only during the following
conditions or combinations hereof:
Brush pressure adjusted too high (beyond specs outlined in SM)
Areas with power supply of 240V
Glunz & Jensen A/S
Haslevvej 13
Improvement(s):
DK-4100 Ringsted The Central Processing Unit (CPU) has been re-configured in the
Denmark
Tel. +45 57 68 81 00 - Call Center firmware – firmware con not be up-graded on-site.
Fax +45 57 68 83 40
customersupport@glunz-jensen.com
www.glunz-jensen.com

Glunz & Jensen, Inc.


21405 Business Court
Elkwood, VA 22718-1757
USA
Tel. +1 540 825-7300
Fax +1 540 825-7525
customersupport@glunz-jensen.com
www.glunz-jensen.com

Glunz & Jensen Representative Office


China South International Industrial
Materials City
Printing, Paper & Packaging Trade
Centre
Block P. 14 – No.125
No. 1 Hua Nan Main Road
Ping Hu, Longgang District
Shenzhen 518111
P.R. China Part no.: Description:
Tel. +86 755 8963 6030
or +86 755 8963 6031 10039872 PCB,MFU,SPARE
Fax +86 755 8963 6032
customersupport@glunz-jensen.com
www.glunz-jensen.com

ECO_09_0162
ECO_09_0414

You might also like