Ф 600 mm
I Data:
Pile Diameter (D) = 600 mm 60 cm
Thickness (t) = 100 mm 10 cm 2t = 20 cm
Concrete Cover = 40 mm 4 cm
Effective Hight (d) = 560 mm 56 cm fcds 28
Class = A1
Diameter of PC Wire = 7.1 mm
Number of PC Wire = 18 pcs
2
Total area of Steel (Aps) = 7.13 cm
2
Area of Concrete = 1,571 cm
II Material
2.1 Concrete
Specified Concrete Compressive Cube Strength at 28 days is 600 Kg/cm2
f'c = (0.76+0.2*log(fck/150))*fck based on PB '89
2
= 528.25 Kg/cm
fcti = 0.9*f'ci^2/3/уc
2
41.838 Kg/cm
2.2 PC Wire
Diameter of PC Wire (d) = 7.1 mm
Cross Section Area (As) = 0.3959 cm2
Tensile Load (Fpu) = 5,721.03 Kg
2
Tensile Strength (fpu) = 14,450.00 Kg/cm
2
Elasticity Modulus of PC Wire (Es) = 1,900,000 Kg/cm
Number of PC Wire (n) = 18 pcs
3.1 Concrete
Cross Section Area (Ag)
Ag = 0.25*pi()*(D-2t)^2
2
= 1,571 cm
3.2 PC Wire
Total Cross Section Area
As = n*0.25*PI()*d^2
2
= 7.13 cm
Page 1 of 4
RESUME OF PRESTRESSED CONCRETE SPUN PILE
Ф 600 mm
Ds = 52 cm
Width of Ring (te) = As/pi()*Ds
= 0.04 cm
d1 = Ds+ts
= 52.04 cm
d2 = Ds-te
= 51.96 cm
Is = 1/64*PI()*(d1^4-d2^4)
4
= 2,408.77 cm
Assumption of Composite
A Comp = Ag+Es/Ec*As
2
= 1609.81 cm
I Comp = Ic+Es/Ec*Is
4
= 523,696.05 cm
Wi = I Comp/r
3
= 17,456.54 cm
2
ES = 312.76 Kg/cm
Page 2 of 4
RESUME OF PRESTRESSED CONCRETE SPUN PILE
Ф 600 mm
Where:
Ksh = = 1.00 for prestressed member
V/S = Volume to Surface Ratio = 5
RH = Average ambient relative humadity = 75 %
2
SH = 272.65 Kg/cm
2
RE = 318.89 Kg/cm
V Effective Prestressed
Fpe = Pi-As*TL
= 69,152 Kg
Fpei = Pi-As*ES
= 75,005 Kg
2 Service
Mcr = (fpe+fct)Wi
= 1,699,955.7 kg.m
= 17.00 ton. m
Page 3 of 4
RESUME OF PRESTRESSED CONCRETE SPUN PILE
Ф 600 mm
β = 0.85-0.008*(fct-30)
= 0.62
у = (D/2-ß*c)*2/(D-t)
= 0.41615224
Allowable Axial
- Nominal Strength
Pn = (0.85*f'c-0.60*fpe)*Ag
= 664 ton
- Service Load
P all = (0.33*f'c-0.27*fpe)*Ag
= 252.7 ton
Page 4 of 4