You are on page 1of 1

Project 7006 7006 7006 7006 7030 7030 7030

Standard Total Standard Total


SN Item Specification Unit VIP Villa Mosque VIP Villa
Villa Villa

1 INSIDE OF VILLA
1.1 Cable for air conditioner unit Internal and external connections

1.1.1 2.5mm² m
1.2 Multi Core Cables, Copper 90°C XLPE insulated, PVC Sheathed 600/1kv
Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for
1.2.1 4 x 150 mm Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and 20 20 0
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.2 4 x 95 mm2 Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and m 2025 704 2729 3630 840 4470
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.3 4 x 35 mm2 Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and m 1620 550 2170 2420 720 3140
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.4 4 x 25 mm Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and 80 80 0
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.5 4 x 16 mm Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and 15 15 0
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.6 4 x 10 mm2 Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and m 1539 440 60 2039 2299 528 2827
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.7 1 x 4 mm2 Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and m 405000 132,000.00 537000 5500 156000 161500
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.8 1 x 6 mm2 Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and m 24300 19,800.00 44100 2500 64800 67300
maintain 90°C

Multi-Conductor Cable: Comply with NEMA WC or IEC 60502 for


1.2.9 1 x 10 mm2 Cu / XLPE / PVC XLPE insulation with PVC sheath, rated for wet locations and m 6480 2,200.00 8680 350 3168 3518
maintain 90°C
1.3 Grounding Wires and Conductors 0

1.3.1 1 x 70 mm2 Cu / PVC 20 0

1.3.2 1 x 50 mm2 Cu / PVC m 2025 704.00 2729 3025 840 3865

1.3.3 1 x 16 mm2 Cu / PVC m 1620 550.00 96 2266 2420 720 3140

1.3.4 1 x 10 mm2 Cu / PVC m 8019 2,640.00 60 10719 2299 3168 5467

1.3.5 1 x 4 m Cu / PVC 7250 0

1.4 Bare Copper Grounding Conductor, Tinned 0

1.4.1 50 mm2 Bare Copper Conductor m 810 110.00 920 1210 240 1450

1.4.2 120 mm² Bare Copper Conductor m 275 275 0

1.4.3 70 mm² Bare Copper Conductor m 810 220.00 120 1150 1210 240 1450

1.4.4 20 x 3000 mm GROUNDING ROD without test pit Ea 81 22.00 103 121 24 145

1.4.5 20 x 3000 mm GROUNDING ROD with test pit Ea 81 22.00 103 121 24 145

1.4.6 Grounding Clamp Ea 81 22.00 103 121 24 145

1.4.7 1.5mm² SHIELDED CABLE m 24,300.00 7480 400 32180 18150 4320 22470

1.4.8 2.5mm² SHIELDED CABLE 145 145 0

1.4.9 Copper Tape 25 x 3 mm m 0 0

1.7 Grounding Busbar 0 0

1.7.1 300 mm length x 50 mm width x 5 mm thick EA 0 0

1.7.2 Audio Cable , 2.5 mm2 Shield m 8910 2420 11330 10285 15600 25885

2 OUTSIDE 7006 7030

2.1 Medium-Voltage Cables


2.1.1 1/C,120MM2 CU/TR-XLPE/LDPE CABLE, 35kV, Single Core, Non-Copper m 9450 12200
2.1.2 1C-120 mm2 TR-XLPE CABLE 35kV, Medium-Voltage Cables Terminations Ea 27.00 42
2.2 Low-Voltage Electrical Power Conductors and Cables
2.2.1 1C x 70 mm2 CU/XLPE/PVC, 0.6/1 kV, Single Core m 34,800.00 59140
2.2.2 1C x 95 mm2 CU/XLPE/PVC, 0.6/1 kV, Single Core m 8,479.00 4800
2.2.3 4C x 95 mm2 CU/XLPE/SWA/PVC, 0.6/1 kV, 4 core, armored Cu, XLPE/SWA/PVC m 50.00 50
2.2.4 2C x 10 mm2 CU/XLPE/SWA/PVC, 0.6/1 kV, 2 core, armored Cu, XLPE/SWA/PVC m 950.00 650
2.2.5 4C x 6 mm2 CU/XLPE/SWA/PVC, 0.6/1 kV, 4 core, armored Cu, XLPE/SWA/PVC m 1,785.00 950
2.2.6 4C x 10 mm2 CU/XLPE/SWA/PVC, 0.6/1 kV, 4 core, armored Cu, XLPE/SWA/PVC m 1,390.00 530
2.2.7 4C x 16 mm2 CU/XLPE/SWA/PVC, 0.6/1 kV, 4 core, armored Cu, XLPE/SWA/PVC m 7,350.00 11010
2.2.8 2C-2.5 mm2 CU/XLPE/PVC(for Light fixtures) m - -
4 x 1C x 150 mm2 CU/XLPE/SWA/PVC, 0.6/1 kV, 4 core, armored Cu,
2.2.9 m 125.00 -
XLPE/SWA/PVC
2.2.10 WARNING TAPE (TERRATAPE) m 64,379.00 89372
2.2.11 COARSE SAND m3 11,588.22 16086.96
2.2.12 Marker Post Ea 1,330.00 1800
2.3 LV Cable Terminations kits (Lugs)
2.3.1 LV cable terminal 4C x 95 mm2 CU/XLPE/SWA/PVC Ea 220.00 40
2.3.2 LV cable terminal 2C x 10 mm2 CU/XLPE/SWA/PVC Ea 18.00 60
2.3.3 LV cable terminal 4C x 6 mm2 CU/XLPE/SWA/PVC Ea 300.00 40
2.3.4 LV cable terminal 4C x 10 mm2 CU/XLPE/SWA/PVC Ea 465.00 20
2.3.5 LV cable terminal 4C x 16 mm2 CU/XLPE/SWA/PVC Ea 745.00 170
2.3.7 LV cable terminal 1C x 70 mm2 CU/XLPE/PVC Ea 382.00 1450
2.3.8 LV cable terminal 1C x 150 mm2 CU/XLPE/PVC Ea 10.00
2.3.9 Bolts and Nuts Ea 4,280.00 3560
2.4 Grounding rod, copper clad steel type
2.4.1 20 mm diameter x 3,000 mm long, without inspection pit Ea 400.00 465
2.4.2 20 mm diameter x 3,000 mm long, with inspection pit Ea 14.00 16
2.4.3 Grounding Clamp Ea 30.00 44
2.5 Bare copper grounding conductor, tinned

2.5.1 70 mm² m 9,450.00 14785


2.6 450/750 V, PVC insulated grounding copper wires, unarmored, single core
2.6.1 1C-2.5 mm2 G m - -

2.6.2 6 mm² m 1,785.00 950

2.6.3 10 mm² m 2,340.00 530

2.6.4 16 mm² m 7,350.00 11010

2.6.5 50 mm² m 50.00 50