You are on page 1of 3

PSU CONTROLLER

SMU48G1

DESCRIPTION
SMU48G1 is a digital controller designed for Sunelt’s PSU
to provide real-time monitoring and management of
telecom power infrastructure.

MONITORING
▪ AC/DC voltage, current, power
▪ Rectifiers data
▪ Battery data
▪ External sensors (ambient temp, battery temp,
humidity, door sensor, smoke sensor, flood sensor)
▪ 2DI (+4DI with an extension board) for dry contacts
▪ Battery and load fuse status

COMMUNICATION DETECTION & REPORTING


▪ Ethernet (TCP/IP support) ▪ 4DO (+4DO with an extension board) for alarms
▪ RS485 ▪ Digital outputs can be set NC or NO
▪ SNMP monitoring ▪ Multiple levels of alarms
▪ SNMP trap ▪ LED indicator and buzzer
▪ Web interface ▪ Historical data (1000 entries)
▪ Cloud monitoring software

RECTIFIER MANAGEMENT BATTERY MANAGEMENT


▪ Adjusting output voltage ▪ Equalization and float charge
▪ Limiting output current ▪ Temperature compensation
▪ Intelligent power management ▪ High/low temp alarms
▪ ECO (sleep) mode ▪ Charging current limit
▪ LVBD
▪ Battery testing
▪ SoC detection

Sunelt Science & Technology Co. Ltd.


Email: info@sunelt.com

sunelt.com

1
PSU CONTROLLER
SMU48G1

TECHNICAL DATA BATTERY MANAGMENT


Rated voltage 53.5VDC Equalization V

Voltage range 42VDC ~ 58VDC Float charge V

Rated current <0.5A Temperature compensation V

Communication Ethernet, RS485, SNMP Battery periodic testing V

User interface Display, Web interface Charging current limit V

MONITORING High/low temp alarm V

Input voltage V LVBD V

Input current V LVLD V

Output voltage V State of charge (SoC) V


detection
Load current V
REMOTE MONITORING
Battery current V
SNMP V
Rectifier status V
SNMP trap V
Rectifier voltage V
Web interface V
Rectifier current V
RS485 V
Rectifier temp V
Remote monitoring V
External sensors:
Ambient temp V ALARM & REPORTING
Battery temp V
Humidity V Digital outputs 4DO + 4DO
Door sensor V (with extension
Smoke detector V board)
Flood sensor V
DO state NC or NO
Digital inputs 2DI + 4DI
(with extension board) LED indicator V

RECTIFIER MANAGEMENT Buzzer V

Output voltage control V Alarm level Minor/Major

Output current limiting V Historical data 1000 entries

Intelligent power V
management

ECO (sleep) mode V

Sunelt Science & Technology Co. Ltd.


Email: info@sunelt.com

sunelt.com

2
PSU CONTROLLER
SMU48G1

Battery Voltage Balance Detection BATTERY VOLTAGE BALANCE


SMU48G1 detects the voltage
Mode Mid-point voltage detection,
balance for each battery in real
Battery voltage balance detection
time by using a signal cable for
monitoring battery voltages. MID-POINT VOLTAGE DETECTION

Max number of battery 6


If the battery voltages are strings
unbalanced, the SMU generates a
Battery CellN Voltage Imbalance BATTERY VOLTAGE BALANCE DETECTION
alarm. Max number of battery 2
strings

Mid-point Voltage Detection Battery Voltage Balance Detection

Sunelt Science & Technology Co. Ltd.


Email: info@sunelt.com

sunelt.com

You might also like