You are on page 1of 8

PTC04-DB-HALL01

Daughter Board for Melexis PTC devices

Features and Benefits Applications


Experimental tool for Lab and Prototyping
PTC04 interface board for testing devices
Production Equipment for Serial Programming
▪ 90215
▪ 90224
▪ 90244
▪ 90251
▪ 90277
▪ 90280

Ordering Information
Part No. Description
PTC04-DBHall Default Daughter Board (Board + rear panel PTC04)

1. Accessories
Part No. Description
DLL’s for all supported products
User Inter Faces for supported products

2. Functional Diagram
PPS
1
VDD
A
External
Measuring
PPS OUT Equipment
2 A

VSS
A

VDD
B
External
Measuring
OUT Equipment
PPS B
3

VSS
B

MEM
A
PPS
4
MEM
B

PPS PPS
+5V +5V
1 1

PWM PWM
Measurements Measurements
OUT OUT
B A

REVISION 2.0 - JUNE 16, 2017


PTC04-DB-HALL01
PTC04-DB-HALL01
Daughter Board for Melexis PTC devices

Contents
Features and Benefits................................................................................................................................ 1
Applications............................................................................................................................................... 1
Ordering Information ................................................................................................................................ 1
1. Accessories ............................................................................................................................................ 1
2. Functional Diagram ............................................................................................................................... 1
Contents.................................................................................................................................................... 2
3. Board description .................................................................................................................................. 3
3.1. Board Layout ....................................................................................................................................... 3
3.2. Board Schematic ................................................................................................................................. 4
3.3. Daughter board Connectors ............................................................................................................... 5
3.3.1. Digital DB Connector (40 Pins) ..................................................................................................... 5
3.3.2. Analog DB Connector (48 Pins) .................................................................................................... 6
3.4. Application Connector ........................................................................................................................ 6
3.4.1. DB15 .............................................................................................................................................. 6
3.4.2. 14 Pins Screw Terminal ................................................................................................................ 7
4. Contact .................................................................................................................................................. 8
5. Disclaimer .............................................................................................................................................. 8

REVISION 2.0 - JUNE 16, 2017 Page 2 of 8


PTC04-DB-HALL01
PTC04-DB-HALL01
Daughter Board for Melexis PTC devices

3. Board description
3.1. Board Layout

J5 Analogue connector

Pin 1
Screw Terminal 14
J1

Application
connector
LED indicators

J9

DB-ID

J3

J6 Digital Connector
J4

Figure 3-1

▪ J1: Jumpers to connect the measurement sensing lines immediately to the force lines. These jumpers
are needed when no force and sense is used.
▪ J3 and J4: These jumpers are future expansions in order to support PWM output measurements and
are not needed for testing the 90251 or the 90277.
▪ DB-ID: This ID keeps a few initial variables in mind. It allows for example to detect what DB is
connected to the programmer and if the DB is not expired.
▪ J5 and J6: these are the Analog and Digital connectors. See below for a detailed description.
▪ Application Connector: Connection to the application. See below for details
▪ J9: 14 pins screw terminal. It provides the same signals as the application connector.

REVISION 2.0 - JUNE 16, 2017 Page 3 of 8


PTC04-DB-HALL01
+5V_DIG_CON
Vout_PPS1

U1 D9 D10 R2
F8 1 18 IOdrv _0 R1 1 D1 2 1 2 2 1
I1 O1 +5V_DIG_CON 10K
F9 2 17 IOdrv _1
I2 O2 R3 1K REL1 P2
FA 3 16 IOdrv _2 1 D2 2 1N4001 1N4148
FB 4 I3 O3 15 IOdrv _3 6 Flatcable_Line_1 1
I4 O4 R4 1K VDD_DIE_1
FC 5 14 IOdrv _4 1 D3 2 1 Flatcable_Line_2 9
I5 O5 VDD_SENSE_DIE_1
FD 6 13 IOdrv _5 R7 5 Flatcable_Line_3 2
I6 O6 R5 1K OUT_DIE_1 MEMO_DIE_1
FE 7 12 IOdrv _6 1 D4 2 2 Flatcable_Line_4 10

PTC04-DB-HALL01
I7 O7 GND_SENSE_DIE_1
FF 8 11 IOdrv _7 4 IOdrv _4 Flatcable_Line_5 3
I8 O8 R6 1K GND_DIE_1
9 10 1 D5 2 2K2 Flatcable_Line_6 11
GND VCC OUT_SENSE_DIE_1
Flatcable_Line_7 4
PTC04-DB-HALL01

R8 1K OUT_DIE_1
ULN2803LW 1 D6 2 3 12
+5V_DIG_CON
DGND +5V_DIG_CON J3 JUMPER Flatcable_Line_9 5
R9 1K VDD_DIE_2
1 D7 2 PE5 1 2 Vout_PPS1 Flatcable_Line_10 13
VDD_SENSE_DIE_2
Pickering 109-2-A-5/2D Flatcable_Line_11 6
R10 1K1 D8 MEMO_DIE_2
2 R11 Flatcable_Line_12 14
GND_SENSE_DIE_2
PE6 1 2 Flatcable_Line_13 7
1K 10K REL2 GND_DIE_2

REVISION 2.0 - JUNE 16, 2017


Flatcable_Line_14 15
3.2. Board Schematic

OUT_SENSE_DIE_2
J4 JUMPER 6 Flatcable_Line_15 8
U2 1 OUT_DIE_2
+5V_DIG_CON
8 1 R12 5 DB15_FEMALE
VDD A0 OUT_DIE_2
7 2 2
PTC A1

DGND
SCL 6 3 4 IOdrv _5 AGND
SDA 5 SCL A2 4 2K2
SDA VSS
3
PCF8582AP +5V_DIG_CON
I2C address : 1010 0000 DGND
D11 D12
1 2 2 1 Pickering 109-2-A-5/2D
+5V_DIG_CON +36V
Daughter Board for Melexis PTC devices

C1 1N4001 1N4148
1 2
+5V_DIG_CON

DGND
1
1
1
1
1
1

100NF_Z5U D13 D17 D21 D25 D29


S1B S1B S1B S1B S1B
1
1
1
1
1
1

D33
S1B
2
2
2
2
2
2

D15 D19 D23 D27 D31 D35


VDD_DIE_1 S1B S1B S1B S1B S1B S1B
2
2
2
2
2
2

J5 VDD_SENSE_DIE_1
Meas_Line_P1 MEMO_DIE_1
1 2 VDD_SENSE_DIE_1
Meas_Line_P2 GND_SENSE_DIE_1
3 4 OUT_SENSE_DIE_1
Meas_Line_P3 OUT_SENSE_DIE_1
5 6 VDD_SENSE_DIE_2
Meas_Line_P4 OUT_DIE_1
7 8 OUT_SENSE_DIE_2
Meas_Line_N1 J9
9 10 Meas_Line_N2 VDD_DIE_2
11 12 GND_SENSE_DIE_1 VDD_DIE_1 1
Meas_Line_N3 VDD_SENSE_DIE_2
13 14 VDD_SENSE_DIE_1 2
Meas_Line_N4 J1 MEMO_DIE_2
15 16 GND_SENSE_DIE_2 MEMO_DIE_1 3
SHTD_PPS1 +36V_SUPPLY GND_SENSE_DIE_2
17 18 +36V GND_SENSE_DIE_1 4
SHTD_PPS2 +5V_SUPPLY 2 1 OUT_SENSE_DIE_2
19 20 +5V_ANA_CON GND_DIE_1 5 VDD_DIE_1 VDD_SENSE_DIE_1
SHTD_PPS3 4 3 OUT_DIE_2
21 22 OUT_SENSE_DIE_1 6 GND_DIE_1 GND_SENSE_DIE_1

AGND
SHTD_PPS4 +2.5V_REF_SUPPLY 6 5
23 24 OUT_DIE_1 7 OUT_DIE_1 OUT_SENSE_DIE_1
8 7
1
1
1
1
1
1

25 26 VDD_DIE_2 8 VDD_DIE_2 VDD_SENSE_DIE_2


ISENSE_PPS1 VOUT_PPS1 10 9 D14 D18 D22 D26 D30
27 28 VDD_SENSE_DIE_2 9 GND_DIE_2 GND_SENSE_DIE_2
12 11 S1B S1B S1B S1B S1B
29 30 MEMO_DIE_2 10 OUT_DIE_2 OUT_SENSE_DIE_2
ISENSE_PPS2 VOUT_PPS2
1
1
1
1
1
1

31 32 GND_SENSE_DIE_2 11 D34
ISENSE_PPS3 33 34 VOUT_PPS3 GND_DIE_2 12 Jumper HEADER 6X2 S1B
35 36 OUT_SENSE_DIE_2 13
2
2
2
2
2
2

37 38 OUT_DIE_2 14

14 pins Screw_terminal
ISENSE_PPS4 VOUT_PPS4 D16 D20 D24 D28 D32 D36
39 40 S1B S1B S1B S1B S1B S1B
41 42
2
2
2
2
2
2

ANA.COMP0 ANA.COMP1
43 44
ANA.COMP2 45 46 ANA.COMP3
47 48 AGND
CON48B
AGND AGND

Vout_PPS1
VDD_DIE_1
REL3
Vout_PPS2 1
4
OUT_DIE_1
+5V_DIG_CON 2
J6 IOdrv _2 3 REL4
DIGITAL DB CONNECTOR1 2
PICKERING 112-1-A-5/2D 7
VDD_DIE_2
A0 A1 1
A2 1 2 A3 5 IOdrv _0
A4 3 4 A5
A6 5 6 A7
D0 7 8 D1 3
9 10 +5V_DIG_CON REL5
D2 D3
D4 11 12 D5 REL6 Pickering 108-1-C-5/3D 2
D6 13 14 D7 Vout_PPS3 1 7
15 16 OUT_DIE_2
Rd Wr 4 1
17 18 Reset 2 5 IOdrv _1
19 20 +5V_DIG_CON
SCL SDA IOdrv _3 3
F8 21 22 F9
FA 23 24 FB PICKERING 112-1-A-5/2D 3
25 26 +5V_DIG_CON
FC FD
FE 27 28 FF R13 Pickering 108-1-C-5/3D
PE0 29 30 PE1 Vout_PPS4
31 32 MEMO_DIE_1
PE2 PE3
PE4 33 34 PE5 100
PE6 35 36 PE7
37 38 +5V_Digital_Supply
39 40 R14
40 Pin Header +5V_DIG_CON
MEMO_DIE_2
DGND 100

Size Project : 90277\90251\90244\90215 Rev


A3 Schematic : PTC04-DB-HALL01 2.0
Date: Wednesday , Nov ember 28, 2007 Sheet 1 of 1

Page 4 of 8
PTC04-DB-HALL01
Daughter Board for Melexis PTC devices

3.3. Daughter board Connectors


The main board has two connectors to the interface with the application. The PTC allows adding a full PCB in between. This
daughter board can be mounted on the two connectors. In some exceptional cases, a daughter board contains only a few
wires from the Analog connector to the application connector. The pins on of the connectors are described below.
ANALOG DB
DIGITAL DB CONNECTOR
CONNECTOR
Meas_Line_P1
A0 A1 1 2 Meas_Line_P2
A2 1 2 A3 3 4 Meas_Line_P3
A4 3 4 A5 5 6 Meas_Line_P4
A6 5 6 A7 7 8 Meas_Line_N1
D0 7 8 D1 9 10 Meas_Line_N2
D2 9 10 D3 11 12 Meas_Line_N3
D4 11 12 D5 13 14 Meas_Line_N4
D6 13 14 D7 15 16 +36V_SUPPLY
Rd 15 16 Wr 17 18
17 18 Reset 19 20
SCL 19 20 SDA 21 22 +2.5V_REF_SUPPLY
F8 21 22 F9 23 24
FA 23 24 FB ISENSE_PPS1 25 26 VOUT_PPS1
FC 25 26 FD 27 28
FE 27 28 FF ISENSE_PPS2 29 30 VOUT_PPS2
PE0 29 30 PE1 31 32
PE2 31 32 PE3 ISENSE_PPS3 33 34 VOUT_PPS3
PE4 33 34 PE5 35 36
PE6 35 36 PE7 ISENSE_PPS4 37 38 VOUT_PPS4
37 38 +5V_Digital_Supply 39 40
39 40 ANA.COMP0 41 42 ANA.COMP1
43 44
40 Pin Header
DGND ANA.COMP2 45 46 ANA.COMP3
47 48
48 pin header
AGND AGND

3.3.1. Digital DB Connector (40 Pins)


Mainly, the digital connector is meant to expand the programmer to extra needs. Address lines A0-A7 together with the Map
Select Lines F8-FF allows to direct access an area of 2 K. Examples would be adding a simple addressed I/O register by using
the selection lines. If more complexity is needed, a full FPGA can be mounted on the DB board
Pins Names Description
1–8 A0 – A7 Address lines
9 – D0 – D7 Data Lines active during Rd or Wr signals
16
17 Rd Read: A negative pulse will indicate a sampling of the data on the Data Bus
18 Wr Write: A Negative pulse will indicate when data is available on the Data Bus
20 Reset This signal goes low by powering the PTC or by pressing the reset button. This line
can be pulled low by application. Check firmware documentation for resetting by
software.
21-22 SCL / SDA I2c Bus
23-30 F8,F9,…,FF CS lines when the address areas are accessed
31-38 Port E Note: These pins are limited to 5 Volt input\output!!!! The full Port E of the Atmega
core is mounted to these pins. This allows us to use advanced features like PWM,
UARTS, Time Measurements, etc…. By using firmware that supports these, functions,
application specific requirements can be fulfilled.
39 Dgnd Digital Ground
40 +5V Digital 5 Volt Digital Supply. Maximum current to get out of this supply: 250mA
Note: All the pins are limited to 5 Volt input\output!!!! However, there are Protections, please take precautions in order to
avoid damage of the main board.

REVISION 2.0 - JUNE 16, 2017 Page 5 of 8


PTC04-DB-HALL01
PTC04-DB-HALL01
Daughter Board for Melexis PTC devices

3.3.2. Analog DB Connector (48 Pins)


Mainly, the analog connector provides all the analog signals and measure possibilities.

Pins Names Description


28,32,36 PPS 1-3 Output of the Programmable Supplies
40 PPS 4 Output of the Fast DAC Programmable Power Supply
27,31,35,39 Isense_PP1-4 Outputs (Driver outputs before Rsens) for current evaluations. These
outputs could be used to connect to the analog comparators in order to
create fast digital signals based on current.
2,4,6,8 ExtMeas1-4Pos There are 4 differential inputs for making measurements
10,12,14,16 ExtMeas1_4Neg The negative inputs of ExtMeas1-4Pos
17,19,21,23 Shtd_PPS1-4 Outputs that shows the status of the Drivers. Signals are meant to connect
LED's to put the front panel
43,44,47,48 AnaComp0-3 Input (limited to 5V) See *Note.
Fast Level comparators in order to remove time consuming measurement
18 +35V_Supply Supply to extend the daughter board with some extra drivers
24 +2.5V Ref Output of internal reference
All other AGND Analog Ground

Note: All the pins are limited to 35 Volt input\output!!!! However, there are Protections, please take precautions in order to
avoid damage of the main board.
* Note: Some pins are protected and limited to 5 Volt!!!! However, there are Protections, please take precautions in order
to avoid damage of the main board.

3.4. Application Connector


3.4.1. DB15
DB15 Female Connector

8 7 6 5 4 3 2 1

15 14 13 12 11 10 9

Pins Names Description


1 VDD A Supply Device A
2 MEMO A
3 VSS A Analog Ground Device A
4 OUT A Output Device A
5 VDD B Supply Device B
6 MEMO B
7 VSS B Analog Ground Device B
8 OUT B Output Device B
9 SENSING VDD A Sensing Supply Device A
10 SENSING VSS A Sensing Analog Ground A
11 SENSING OUT A Sensing Output
12 NC Not Connected
13 SENSING VDD B Sensing Supply Device B
14 SENSING VSS B Sensing Analog Ground B
15 SENSING OUT B Sensing Output Device B

REVISION 2.0 - JUNE 16, 2017 Page 6 of 8


PTC04-DB-HALL01
PTC04-DB-HALL01
Daughter Board for Melexis PTC devices

3.4.2. 14 Pins Screw Terminal


14 Pin Screw Terminal

14 13 12 11 10 9 8 7 6 5 4 3 2 1

Pins Names Description


1 VDD A Supply Device A
2 SENSING VDD A Sensing Supply Device A
3 MEMO A
4 SENSING VSS A Sensing Analog Ground A
5 VSS A Analog Ground Device A
6 SENSING OUT A Sensing Output
7 OUT A Output Device A
8 VDD B Supply Device B
9 SENSING VDD B Sensing Supply Device B
10 MEMO B
11 SENSING VSS B Sensing Analog Ground B
12 VSS B Analog Ground Device B
13 SENSING OUT B Sensing Output Device B
14 OUT B Output Device B

REVISION 2.0 - JUNE 16, 2017 Page 7 of 8


PTC04-DB-HALL01
PTC04-DB-HALL01
Daughter Board for Melexis PTC devices

4. Contact
For the latest version of this document, go to our website at www.melexis.com.

For additional information, please contact our Direct Sales team and get help for your specific needs:

Europe, Africa Telephone: +32 13 67 04 95

Email : sales_europe@melexis.com

Americas Telephone: +1 603 223 2362

Email : sales_usa@melexis.com

Asia Email : sales_asia@melexis.com

5. Disclaimer
The information furnished by Melexis herein (“Information”) is believed to be correct and accurate. Melexis disclaims (i) any and all liability in connection with or arising out of the
furnishing, performance or use of the technical data or use of the product(s) as described herein (“Product”) (ii) any and all liability, including without limitation, special,
consequential or incidental damages, and (iii) any and all warranties, express, statutory, implied, or by description, includ ing warranties of fitness for particular purpose, non-
infringement and merchantability. No obligation or liability shall arise or flow out of Melexis’ rendering of technical or other services.
The Information is provided "as is” and Melexis reserves the right to change the Information at any time and without notice. Therefore, before placing orders and/or prior to
designing the Product into a system, users or any third party should obtain the latest version of the relevant information to verify that the information being relied upon is current.
Users or any third party must further determine the suitability of the Product for its application, including the level of reliability required and determine whether it is fit for a
particular purpose.
The Information is proprietary and/or confidential information of Melexis and the use thereof or anything described by the Information does not grant, explicitly or implicitly, to
any party any patent rights, licenses, or any other intellectual property rights.
This document as well as the Product(s) may be subject to export control regulations. Please be aware that export might require a prior authorization from competent authorities.
The Product(s) are intended for use in normal commercial applications. Unless otherwise agreed upon in writing, the Product(s ) are not designed, authorized or warranted to be
suitable in applications requiring extended temperature range and/or unusual environmental requirements. High reliability applications, such as medical life-support or life-
sustaining equipment are specifically not recommended by Melexis.
The Product(s) may not be used for the following applications subject to export control regulations: the development, product ion, processing, operation, maintenance, storage,
recognition or proliferation of 1) chemical, biological or nuclear weapons, or for the development, production, maintenance or storage of missiles for such weapons: 2) civil
firearms, including spare parts or ammunition for such arms; 3) defense related products, or other material for military use or for law enforcement; 4) any applications that, alone
or in combination with other goods, substances or organisms could cause serious harm to persons or goods and that can be used as a means of violence in an armed conflict or any
similar violent situation.
The Products sold by Melexis are subject to the terms and conditions as specified in the Terms of Sale, which can be found at https://www.melexis.com/en/legal/terms-and-
conditions.

This document supersedes and replaces all prior information regarding the Product(s) and/or previous versions of this document.

Melexis NV © - No part of this document may be reproduced without the prior written consent of Melexis. (2016)

ISO/TS 16949 and ISO14001 Certified

REVISION 2.0 - JUNE 16, 2017 Page 8 of 8