Ultrasonic sensor Safety Notes Ԏ Multifunctional input »Com« set to

with one analogue output Ԏ Read the operating manual prior 2 1 »Teach-in«
to start-up. 3 5 4
Synchronisation
colour
Product Description Ԏ Connection, installation and ad-
1 +UB brown If the assembly distance falls below pico+15... ≥0.25 m ≥1.30 m
The pico+ sensor offers a non-contact justment works should be carried 3 –UB blue the values shown in fig. 2, the internal
measurement of the distance to an out by expert personnel only. 4 – black pico+25... ≥0.35 m ≥2.50 m
synchronization should be used. For
object that has to be present within Ԏ No safety component in ac- 2 I/U white
this purpose set the switched outputs pico+35... ≥0.40 m ≥2.50 m
the sensor’s detection zone. Depen- cordance with the EU Machine 5 Com grey
of all sensors in accordance to the dia-
ding on the set window limits, a dis- Directive, use in the area of per- Fig. 1: Pin assignment with view onto sensor pico+100... ≥0.70 m ≥4.00 m
plug and colour coding of the microso-
gram »Sensor adjustment with Teach-
tance-proportional analogue signal is sonal and machine protection in procedure« at first. Then set the Fig. 2: Assembly distances, indication synchro-
nic connection cable
output. not permitted multifunctional output »Com« to
nisation
The window limits of the analogue Proper Use Start-Up »synchronization« (see »Further set- Notes
output and its characteristic can be pico+ ultrasonic sensors are used for Î Connect the power supply.
tings«, Diagram 1). Finally connect pin Ԏ The sensors of the pico+ family
adjusted via Teach-in procedure. Two non-contact detection of objects. Î Set the sensor parameters using the
5 of the sensors plug of all sensors. have a blind zone. Within this zone
Operating Manual LEDs indicate the state of the ana- Teach-in procedure, see Diagram 1.
Installation Maintenance a distance measurement is not pos-
pico+15/I pico+15/WK/I logue output. Factory Setting sible.
Î Mount the sensor at the installation microsonic sensors are maintenance-
pico+25/I pico+25/WK/I pico+ sensors are delivered factory
pico+35/I pico+35/WK/I site. free. In case of excess caked-on dirt Ԏ Every time the power supply is swit-
pico+100/I pico+100/WK/I Î Connect a connection cable to the made with the following settings: we recommend to clean the white ched on, the sensor detects its ac-
pico+15/U pico+15/WK/U Ԏ Rising analogue characteristic curve
M12 device plug, see Fig. 1. sensor surface. tual operating temperature and
pico+25/U pico+25/WK/U between the blind zone and the transmits it to the internal tempera-
pico+35/U pico+35/WK/U operating range
pico+100/U pico+100/WK/U
ture compensation. The adjusted
value is taken over after 120 se-
conds.
Diagram 1: Set sensor parameters via Teach-in procedure
Ԏ In the normal operating mode, an
illuminated yellow LED signals the
Set analogue output Further settings
object is within the window limits.
1 2 Ԏ If synchronisation is activated the
Teach-in is disabled (see »Further
settings«, Diagram 1).
Set rising/falling output Reset to
Set window limits characteristic curve Switch Teach-in + sync factory setting Ԏ The sensor can be reset to its facto-
ry setting (see »Further settings«,
Diagram 1).
Switch off power supply. Switch off power supply.
Ԏ Optionally all Teach-in and additio-
nal sensor parameter settings can be
Place object at position 1 . Connect Com to –UB. Connect Com to –UB. adjusted via the LinkControl adapter
(optional accessory) and the Link-
Control software for Windows©.
Switch on power supply. Switch on power supply.

Keep Com connected to


Connect Com for about 3 s Connect Com for about Keep Com connected to
–UB for about 3 s, until
to +UB, until both LEDs flash 13 s to +UB, until both –UB for about 13 s, until
both LEDs flash
simultanously. LEDs flash alternately. both LEDs stop flashing.
simultaneously.
Both LEDs: flash Green LED: flashes Green LED: flashes
alternately
Yellow LED: on: rising Yellow LED: on: Teach-in Disconnect Com from –UB.
Place object at position 2 . off: falling off: Sync
characteristc
curve

To change output To change operating mode


Connect Com for about
characteristic connect Com connect Com for
1 s to +UB.
for about 1 s to +UB. about 1 s to –UB.

Wait for about 10 s. Wait for about 10 s.

Normal operating mode Normal operating mode


Technical data
pico+15... pico+25... pico+35... pico+100...
24 width A/F 24 width A/F 24 width A/F 24 width A/F
LED 4 LED 4 LED 4 LED 4
1
+UB

M18x1

M18x1

M18x1

M18x1
2
U 4
I/U
RL

M12x1

M12x1

M12x1

M12x1
5
Com

3.4

3.4

3.4

3.4
3
–UB
1 analogue output

25.5 25.5 25.5 25.5


40.5 40.5 40.5 40.5
56.5 56.5 56.5 56.5

blind zone 20 mm 30 mm 65 mm 120 mm


operating range 150 mm 250 mm 350 mm 1.000 mm
maximum range 250 mm 350 mm 600 mm 1.300 mm
angle of beam spread see detection zone see detection zone see detection zone see detection zone
transducer frequency 380 kHz 320 kHz 400 kHz 200 kHz
resolution 0.069 mm 0.069 to 0.1 mm, depending on the 0.069 to 0.17 mm, depending on the 0.069 to 0.38 mm, depending on the
analogue window analogue window analogue window
detection zones

10 cm

10 cm

0.4 m

0.2 m

0.2 m

0.4 m
8 cm

4 cm

0 cm

4 cm

8 cm

20 cm

10 cm

10 cm

20 cm
5 cm

0 cm

5 cm

0 cm
for different objects:

0m
The dark grey areas are determi- 0 cm 0 cm 0 cm 0m
ned with a round bar and indicate
the typical operating range of a
sensor. In order to obtain the light 4 cm
5 cm
10 cm
0.2 m
grey areas, a plate (100 x 100 mm) Plate Plate
Round bar ø 10 mm Plate
is introduced into the beam spread
10 cm 0.4 m
from the side. 20 cm Round bar
In doing so, the optimum angle 8 cm Round bar ø 10 mm
Round bar ø 10 mm ø 10 mm
between plate and sensor is al- 15 cm
0.6 m
ways employed. 30 cm
This therefore indicates the maxi- 12 cm
Plate 35 cm 0.8 m
mum detection zone of the sensor. 20 cm
It is not possible to evaluate ultra- 40 cm
sonic reflections outside this area. 16 cm 1.0 m
25 cm
50 cm
1.0 m
20 cm
30 cm 1.3 m
60 cm 1.4 m
24 cm 35 cm

reproducibility ±0.15 % ±0.15 % ±0.15 % ±0.15 %


accuracy ±1 % (Temperature drift internal compensated) ±1 % (Temperature drift internal compensated) ±1 % (Temperature drift internal compensated) ±1 % (Temperature drift internal compensated)
no-load current consumption <40 mA <40 mA <40 mA <40 mA
operating voltage ripple ±10 % ±10 % ±10 % ±10 %
housing brass sleeve, nickel-plated, plastic parts: PBT; brass sleeve, nickel-plated, plastic parts: PBT; brass sleeve, nickel-plated, plastic parts: PBT; brass sleeve, nickel-plated, plastic parts: PBT;
ultrasonic transducer: polyurethane foam, ultrasonic transducer: polyurethane foam, ultrasonic transducer: polyurethane foam, ultrasonic transducer: polyurethane foam,
epoxy resin with glass content epoxy resin with glass content epoxy resin with glass content epoxy resin with glass content
max. tightening torque of nuts 15 Nm 1 Nm 15 Nm 15 Nm
class of protection to EN 60529 IP 67 IP 67 IP 67 IP 67
norm conformity EN 60947-5-2 EN 60947-5-2 EN 60947-5-2 EN 60947-5-2
type of connection 5-pin M12 initiator plug 5-pin M12 initiator plug 5-pin M12 initiator plug 5-pin M12 initiator plug
controls Teach-in via pin 5 (Com) Teach-in via pin 5 (Com) Teach-in via pin 5 (Com) Teach-in via pin 5 (Com)
scope for setting Teach-in, LinkControl Teach-in, LinkControl Teach-in, LinkControl Teach-in, LinkControl
indicators LED green, LED yellow LED green, LED yellow LED green, LED yellow LED green, LED yellow
synchronisation internal synchronisation up to 10 sensors internal synchronisation up to 10 sensors internal synchronisation up to 10 sensors internal synchronisation up to 10 sensors
operating temperature –25 to +70 °C –25 to +70 °C –25 to +70 °C –25 to +70 °C
storage temperature –40 to +85 °C –40 to +85 °C –40 to +85 °C –40 to +85 °C
response time 1) 32 ms 32 ms 64 ms 80 ms
time delay before availability <300 ms <300 ms <300 ms <300 ms
analogue output 4 to 20 mA RL ≤ 500 Ω, rising/falling characteristic RL ≤ 500 Ω, rising/falling characteristic RL ≤ 500 Ω, rising/falling characteristic RL ≤ 500 Ω, rising/falling characteristic
operating voltage UB 10 to 30 V DC for RL ≤ 100 Ω 10 to 30 V DC for RL ≤ 100 Ω 10 to 30 V DC for RL ≤ 100 Ω 10 to 30 V DC for RL ≤ 100 Ω
20 to 30 V DC for RL > 100 Ω 20 to 30 V DC for RL > 100 Ω 20 to 30 V DC for RL > 100 Ω 20 to 30 V DC for RL > 100 Ω
terminal reverse polarity protected, Class 2 terminal reverse polarity protected, Class 2 terminal reverse polarity protected, Class 2 terminal reverse polarity protected, Class 2
order no. directly radiating pico+15/I pico+25/I pico+35/I pico+100/I
weight 30 g 30 g 30 g 30 g
order no. angular head pico+15/WK/I pico+25/WK/I pico+35/WK/I pico+100/WK/I
weight 35 g 35 g 35 g 35 g
analogue output 0 to 10 V RL ≥ 100 kΩ, short circuit proof, RL ≥ 100 kΩ, short circuit proof, RL ≥ 100 kΩ, short circuit proof, RL ≥ 100 kΩ, short circuit proof,
rising/falling characteristic rising/falling characteristic rising/falling characteristic rising/falling characteristic
operating voltage UB 15 to 30 V DC, 15 to 30 V DC, 15 to 30 V DC, 15 to 30 V DC, Enclosure Type 1
For use only in industrial
terminal reverse polarity protected, Cl. 2 terminal reverse polarity protected, Cl. 2 terminal reverse polarity protected, Cl. 2 terminal reverse polarity protected, Cl. 2 machinery NFPA 79 applications.
order no. directly radiating pico+15/U pico+25/U pico+35/U pico+100/U
weight 30 g 30 g 30 g 30 g
order no. angular head pico+15/WK/U pico+25/WK/U pico+35/WK/U pico+100/WK/U The proximity switches shall be used with a Listed
(CYJV/7) cable/connector assembly rated mini-
weight 35 g 35 g 35 g 35 g mum 32 Vdc, minimum 290 mA, in the final in-
1) With LinkControl, the selected filter setting influences the response time. stallation.

microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / T +49 231 975151-0 / F +49 231 975151-51 / E info@microsonic.de / W microsonic.de
The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not warrant any product features. *B9632*
MV-DO-119336-828469