You are on page 1of 1

REINFORCEMENT DETAILING OF RETAINING WALL

St DIMENSIONAL DETAILS OF RCC RETAINING WALL

a10
a6 600 MM THK.
FILTER MEDIA

a9 100 MM Ø
Ld

WEEP HOLE
a10 1.0 M C/C
a8 STAGGERED
H

(TYP)
a5
a8
Hc2

GROUND LEVEL
a5 + a9
GROUND LEVEL
Hc1

a11
CONCRETE - M:25 NOTES:-
MIN LD OF a7 a4 Sb
MAX DIA BAR 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVEL ARE IN METERS
a7
UNLESS NOTED OTHERWISE.
a3 2. DIMENSIONS ARE TO BE SCALED ONLY WRITTEN DIMENSIONS

Ht1
Ht
Tt

SHALL BE FOLLOWED.
Tt1

3. GRADE OF CONCRETE - M:25


4. GRADE OF STEEL FE -500 TMT YIELD STRENGTH DEFORMED BARS
LD MIN.
a7 a2 Bt CONFIRMING TO IS : 1786 - 2000.
TYP. a1 2LD OF MAX.DIA PCC M-10 (100 MM THK.)
B 5. LAP JOINT SHALL BE PROVIDED IN STAGGERED MANNER AND NOT
OF BAR
MORE THAN 50% OF REINFORCEMENT BARS SHALL BE LAPPED AT
ANY LOCATION.
REINFORCEMENT DETAILS R.C.C. WALL DIMENSIONAL DETAILS RETAINING WALL 6. CLEAR COVER
6.1. BASE SLAB - 75 MM
6.2. OTHER THAN BASE SLAB - 40 MM
7. DEVELOPMENT LENGTH (LD) OR LAP LENGTH SHALL BE 50 TIMES DIA.
8. BREAKING CAPACITY OF FOUNDATION MATERIAL SHALL NOT BE LESS
THAN 120 KN/m2

DRAWING CATEGORY DRAWING PURPOSE TITLE Patel Engineering Ltd. SHEET


SIZE
CONCEPT FOR INFORMATION
Patel Estate Road, Jogeshwari West,
SCHEMATIC FOR TENDER PURPOSE STANDARD RETAINING WALL DETAILS MUMBAI-400 102, TEL: +91 22 26767500 / 26782455
SURVEY DRAWING FOR EXCAVATION Email : info@pateleng.com A3
APPROVAL DRAWING www.pateleng.com
FOR APPROVAL
WORKING DRAWING FOR CONSTRUCTION DRAWN DESIGNED APPROVED SCALE DRG. No. REV.
AS BUILT REV. DATE DRN. BY DESCRIPTION BHUPESH Y.PRATAP S.DEBNATH NTS