SYMPTOM:
COPY QUALITY
Toner marks appear on the rear side of the copies.
CAUSE:
Toner adheres to the hot roller strippers and dislodges onto the copies.
SOLUTION:
The width of the hot roller strippers has been decreased from 3mm to 0.5mm and the pressure of the tension
PARTS
spring has been decreased from 300mN to 50mN.
REFERENCE
OLD PART NO. NEW PART NO. DESCRIPTION QTY INT PAGE ITEM
AA060879 AA060948 Tension Spring 7 1 51 9
AE044030 AE044056 Hot Roller Stripper 7 1 51 10
NOTE: When installing these parts for the first time, they must be changed together as a set.
UNITS AFFECTED:
All B079/B082 copiers manufactured after the serial numbers listed below will have the new style parts
installed during production
INTERCHANGEABILITY CHART:
OLD and NEW parts can be used in both OLD and NEW parts CAN NOT be used in OLD machines.
0 NEW machines. 2 OLD parts can be used in OLD and NEW machines.
NEW parts can be used in OLD and NEW machines. OLD parts CAN NOT be used in NEW machines.
1 OLD parts CAN NOT be used in NEW machines. 3 NEW parts CAN NOT be used in OLD machines.
Must be installed as a set on units manufactured prior to the S/N cut-in. On units manufactured after the S/N cut-in or
3/S previously modified, use the new part numbers individually.
Page 2 of 2