32a Dyke Road Avenue Product code

71 / 53 / 1.1

total thickness = 30 mm
Glazing from external to internal:

Pane 1 Pane 2
6 mm Float Glass ExtraClear ClimaGuard A 1.0
6 mm Float Glass ExtraClear

Spacer 1 - 18 mm
10% Air
90% Argon

Results
Visible light (EN 410 - 2011) Solar energy (EN 410 - 2011)
transmittance [%] 70.8
solar factor [%]
τv = g = 52.8
reflectance external [%] shading coefficient [g/0.87]
ρv = 20.9 sc = 0.61
reflectance internal [%] 22.2
direct transmittance [%]
ρv = τe = 45.3
general colour rendering index 96.7
direct reflectance external [%]
Ra = ρe = 35.3
direct reflectance internal [%] ρe = 35.2
Thermal properties (EN 673 - 2011) direct absorption [%] a = 19.4
U-value [W/(m²K)] slope α = 90° UV transmittance [%] τuv = 31.9
according to EN: Ug = 1.1 secondary internal heat transfer factor [%] qi = 7.5
3 decimal places: Ug = 1.051 Other data
estimated sound reduction index [dB] Rw = NPD
(EN 717-1) C = NPD
Ctr = NPD

The calculated values are for orientation only and do not offer any guarantee regarding the fabrication of the un- intended end- product. Glass