Guía de Proceso de Tintas Penetrantes

Cinco consejos para


Method A: Water Wash Fluorescent Method B/D: Post Emulsifiable pruebas de Tintas
Fluorescent Penetrantes
ZL-15B, Level ½
Daraclean 282 ZL-19, Level 1
Daraclean 200 ZL-60D*, Level 2
Daraclean 236 ZL-67, Level 3
ZL-56, Level 4
1. Controlar requerido especificaciones
Daraclean 282 ZL-2C Level 2
Daraclean 200 ZL-27A* Level 3 antescomienzo penetrante inspección.
1. Preclean with 2. Apply Penetrant 3. Dwell 4. Rinse Daraclean 236 ZL-37* Level 4
Daraclean 10−30 minutes (in some 50−100°F / 10−38°C
cases longer) at <40 psi / 2.75 bar
1. Preclean with 2. Apply Penetrant 3. Dwell
2. Certificaciones, SDS, PDS, y
Daraclean 10−30 minutes instrucciones son disponible en
www.magnaflux.com
ZP-5B Water
Suspendible
3. Verificar eso partes a ser
5. Apply Aqueous 6. Dry 7. Dwell penetrante probado son limpio y seco
Developer 160°F / 71°C maximum 10 min–2 hr maximum
antes aplicando penetrante.
ZR-10E Hydrophilic ZE-4E Lipophilic

ZP-4D Dry Powder


4. Magnaflux ofertas PeneCert
8. Inspect Pruebas Servicio para en proceso
4a. Rinse 4b. Apply Emulsifier 4. Apply Emulsifier

5. Dry 6. Apply Dry 7. Dwell


50−100°F / 10−38°C at penetrante materiales. Contacto
<40 psi / 2.75 bar
10 min–4 hr maximum
160°F / 71°C maximum Developer Magnaflux Cliente Servicio para
detalles en soporte@magnaflux.com

5. Magnaflux penetrante productos


son disponible en equipos para
Method C: Solvent Removable, Fluorescent, 5. Rinse convenienciay portabilidad.
50−100°F / 10−38°C at
and Nonfluorescent <40 psi / 2.75 bar

1. Preclean 2. Apply Penetrant 3. Dwell 4. Remove Excess Penetrant


Cleaner options: SKC-S* Penetrant options: 10–30 minutes Spray SKC-S* cleaner onto a clean, ZP-5B Water Suspendible
dry lint-free cloth. DO NOT apply ZP-14A Water Soluble
ZL-27A*, ZL-37*, ZL-60D*,
SKL-SP2*, or SKL-WP2* cleaner directly onto the
part or test area.
6. Apply Developer 6. Dry
160°F / 71°C maximum

ZP-4D Dry Powder


ZP-9F* Solvent Based

5. Remove Penetrant 6. Apply Developer 7. Dwell


7. Dry 8. Dwell 7. Apply Developer
Use the cloth to remove Developer options: 10–60 minutes
160°F / 71°C maximum 10 minutes minimum
excess surface penetrant SKD-S2* or ZP-9F*
with minimal wiping.

9. Inspect

8. Inspect 8. Inspect
in a well lit environment under a UV lamp

* Disponible en Aerosol