Electronic Surge Protection (ESP)

Product Catalogue

Your Preferred Lightning & Security


Solutions Provider

www.tokai.com.my
TOKAI ESP TOKAI ESP
Power Protector - Parallel Connection Power Protector - Parallel Connection
Power Surge Protector Device Installation Product Specifications
Use for Main Power Supplies where sensitive or important electrical and
The protector is installed in parallel as indicated in the Supply Type Single Phase Three Phase
electronic equipments are connected.
diagrams below. The protector should be installed at the Parallel Model TSP 240M1 TSP 415M1
Protects the electrical and electronic equipments from Transient
Over-voltage caused by lightning or electrical switching in the Main load side of the incoming main breakers before any Nominal Voltage Vn (RMS) 240V 415V
Power Supplies. outgoing breaker.
Operational Voltage Vo (RMS) 200-270V 346-470V
Suitable for Tele-communications, Control, Computer, Networking and
many other systems. It is recommended to fuse the leads of the protector with Operational Frequency 40-60Hz 40-60 Hz
Can be installed in Main Switchboard, Distribution Board and all power MCCB or HRC fuses. Please see product specifications for Leakage Current <200µA <200µA
distribution systems. MCCB or HRC fuse settings. Clamping or Let-through Voltage Vp
Suitable for TN power supply system.
Protector for Single Phase Supply 220 / 230 / 240VAC, 40/60Mz. Incoming Supply 6kV 1.2/50µs, 3kA 8/20µs <600V <600V
Protector for Three Phase Supply 380 / 400 / 415VAC, 40/60Mz. NO NC COM
L1 L2 L3 N E Mode of Protection (Full Mode) L-N, L-E, N-E L1-N, L2-N, L3-N,
Uses hybrid circuit protection to achieve both very low let-through voltage
L1-E, L2-E, L3-E, N-E
and high discharge current.
Surge Protection Device
Note: The XX denotation represents the maximum discharge current (Imax), see below for complete model number

Product Features
L1 L2 L3
Maintenance free Status Indicator Model No. TSP 240M1 TSP 240M2 TSP 415M1 TSP 415M2 TSP 415M4
Parallel Connection allows easy installation Green
Green + Red
Full Protection
Partial Protection Max. Discharge Current (Imax) 40kA 80kA 40kA 80kA 120kA
Suitable for TN supply system c/w Earth & Neutral Red Damaged

8/20µs per mode


Nominal Voltage 415VAC

Selection of maximum discharge current (Imax) to suit application / Let Through Voltage
Max. Discharge Current
600V
160kA/unit

Lightning Risk Category Your Preferred Lightning & Security Solutions Provider Max. Discharge Current (Imax) NA NA 80kA 160kA 240kA
Very low let-through or claming voltage (Vp) www.tokai.com.my

Full mode protection for single phase (L-N, N-E and L-E) and three phase L1 L2 L3 N E 8/20µs per phase
(L1-N, L2-N, L3-N, L1-E, L2-E, L3-E and N-E supplies) Total Max. Discharge Current (Imax) 80kA 160kA 160kA 320kA 480kA
Thermal tripping device allows safety disconnect due to faulty supplies 8/20µs per unit
Continuous and repeated protection in intense environment
Electronic indication with Pre-failure warning allows preparation of
replacement Other Specifications
Outgoing
Remote indication using volt free contact allows easy integration to To Load Operation Temperature -40 to 70°C -40 to 70°C -40 to 70°C -40 to 70°C -40 to 70°C
control or monitoring systems
Robust metallic casing Conductor Size (mm2) 25 25 25 25 25
Weight (kg) 1.0 1.1 1.6 1.8 2.2
Physical Dimensions (mm)
Testing Specifications
Incoming Supply
Tested to 6kV 1.2/50µs, 3kA 8/20µs, accordance to NO NC COM
L N E
BS6651:1999, Appendix C, Cats C-Low & B-High
IEEE C62.41-1991, Location Cats C1 & B3 Surge Protection Device
SS CP33:1996, Appendix F
AS 1768-1991, Appendix B, Cat B
UL 1449 mains wire-in
Tested to 6kV 0.5µs, 100kHz ring wave, 500A, accordance to
Status Indicator
IEEE C62.41-1991 Location Cat B3
Green Full Protection

AS 1768-1991, Appendix B, Cat B Green + Red


Red
Nominal Voltage
Partial Protection
Damaged
415VAC
Let Through Voltage 600V
Max. Discharge Current 160kA/unit

Your Preferred Lightning & Security


Solutions Provider

www.tokai.com.my

L N E

Outgoing
To Load
Remote Control Ratings
Maximum Current 1A 1A 1A 1A 1A
Maximum Voltage 250VAC or 48VDC
TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

pg 02 pg 03
TOKAI ESP TOKAI ESP
Power Protector - Low-Current Series Connection Power Protector - Low-Current Series Connection
Power Surge Protector Device Installation Product Specifications
Use for low current Main Power Supplies where sensitive or important Supply Type Single Phase Single Phase Single Phase
electrical and electronic equipments are connected.
The protector is installed in series as indicated in the
diagrams below. The protector should be installed as Parallel Model TPV 240-6A TPV 240-13A TPV 240-20A
Protects the electrical and electronic equipments from Transient
Over-voltage caused by lightning or electrical switching in the Main close to the equipment to be protected. Ensure the Nominal Voltage Vn (RMS) 240V 240V 240V
Power Supplies. incoming supply and output to equipment are connected Operational Voltage Vo (RMS) 200-270V 200-270V 200-270V
Suitable for low current systems such as Field Control and Monitoring correctly.
Operational Frequency 40-60Hz 40-60Hz 40-60Hz
Panel, Tele-communication equipment and Mobile Electrical & Electronic
Equipment. It is recommended to fuse the leads of the protector with Maximum Operating Current ≤6A ≤13A ≤20A
Can be installed in Distribution Panel, Control Panel, Terminal Boxes and fused rated in accordance to the unit current rating. The Leakage Current <500µA <500µA <500µA
Equipment Panels. earth is connected at the DIN rail which the unit is
installed on. Clamping or Let-through Voltage Vp
Protector for Single Phase Supply 220 / 230 / 240VAC, 40/60Mz.
Selection of operating current rating, 6, 13 and 20 Amps. 6kV 1.2/50µs, 3kA 8/20µs <600V <600V <600V
Uses hybrid circuit protection to achieve both very low let-through voltage Mode of Protection (Full Mode) L-N, L-E, N-E L-N, L-E, N-E L-N, L-E, N-E
and high discharge current. Series Low Current Protector

OUT

OUT
LNE

LNE
E

E
Operational Voltage
200 - 270Vrms

Product Features
Operation Frequency

N
50 - 60Hz
Max. Current Your Preferred Lightning & Security
6A

L
Solutions Provider

L
Max. Discharge Current STATUS
Fuse 20kA per unit

Maintenance free Model No. TPV 240-6A TPV 240-16A TPV 240-20A

OUT

OUT
www.tokai.com.my

LNE

LNE
Unit is recommended to be fused at
rated maximum current or less

Series Connection
Max. Discharge Current (Imax) 10kA 10kA 10kA
LED status indication
Small in size 8/20µs per mode
Can be installed via DIN rail or Screws mounted. (DIN rails is removable Total Max. Discharge Current (Imax) 20kA 20kA 20kA
for Screw mount)
8/20µs per unit
Wide current range to ensure better compatibility to protected
equipements
Maximum discharge current of 10kA per mode, 20kA per unit Other Specifications
Fuse
Low let-through or claming voltage (Vp)
Full mode protection for single phase (L-N, N-E and L-E) supplies
Operation Temperature -40 to 70°C -40 to 70°C -40 to 70°C
Thermal tripping device allows safety disconnect due to faulty supplies Mounting DIN rail according to EN50022 or Screw mount (DIN rail is removable)
Continuous and repeated protection in intense environment Conductor Size (mm2) 2.5 2.5 2.5
Weight (kg) 0.3 0.35 0.4
Testing Specifications Physical Dimensions (mm)
Tested to 6kV 1.2/50µs, 3kA 8/20µs, accordance to
BS6651:1999, Appendix C, Cats C-Low & B-High
IEEE C62.41-1991, Location Cats C1 & B3
SS CP33:1996, Appendix F
AS 1768-1991, Appendix B, Cat B
UL 1449 mains wire-in
Tested to 6kV 0.5µs, 100kHz ring wave, 500A, accordance to
IEEE C62.41-1991 Location Cat B3
AS 1768-1991, Appendix B, Cat B

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

pg 04 pg 05
TOKAI ESP TOKAI ESP
Closed Circuit Television Protector Closed Circuit Television Protector
Power Surge Protection Device Installation Product Specifications
Use for CCTV (Closed Circuit Television) system application Model TCV BNC
Protects the CCTV Camera and monitoring system from Transient
To begin it is important to ensure that the protector is
suitable for the system to be installed based on the Nominal Voltage (Peak to Peak) 1V
Over-voltage caused by lightning or electrical switching in the Main
Power Supplies. voltage, current and bandwidth. The protector is installed Maximum Continuous Operating Voltage 6.3V
Can be installed in at CCTV camera, CCTV monitoring system control in series as indicated in the diagram below. Ensure that Maximum Load Current 300mA
panel, terminal boxes and equipment panels. the input (wires going away from the equipment) and
Clamping or Let-through Voltage Vp
Suitable for BNC Coaxial Connector both earthed and un-earthed output (wires going towards the equipment) are
system connected correctly to ensure protection. Arrange the 5kV 10/700µs, 125A ITU Standard 17.5V
Uses hybrid circuit protection to achieve both very low let-through voltage incoming and outgoing wire correctly to ensure no Nominal In-Line Resistance (per line) 1Ω
and high discharge current. transient goes back to the system via induction. Bandwidth (-3dB, 75Ω system) More than 20MHz
Voltage Standing Wave Radio Less than 1.2
When installing for unearth system, remove the metallic
Product Features screw at the top of the box and replace it with the Leakage Current (Nominal Voltage) 1µA
non-metallic screw provided. Capacitance Less than 30pF

LINE OUT
LINE IN
Maintenance free.
Series Connection. Data Signal Protector
Mode of Protection Line to screen, Line to Earth, Screen to Earth
High current limit (300mA) allow usage in wide range of system.
Nominal Voltage - 1V | Maximum Voltage - 6.3V
Low in line resistance of 1Ω allow easy compatibility to applied system. Maximum Current - 300mA | In-Line Resistance - <1Ω
Operating Bandwidth - >20MHz

Changeable configuration from earthed to un-earthed systems. Line


Line Line
Line
Model No. TCV BNC
Allow high bandwidth of more than 20Mhz.
In Out
Earth
Disconnecting screw.
To be removed for
Earth
Total Max. Discharge Current (Imax) 10kA
Metallic enclosure.
unearthed system

System Screen

BNC Coaxial connector allow easy installation and replacement of the


From Field To Equipment 8/20µs
Your Preferred Lightning & Security Solutions Provider

protector. www.tokai.com.my

DIN rail mounting or panel mount enable easy installation


Other Specifications
Earthing via DIN Rails permitting easy installation From Field To Equipment
Low let-through or clamping voltage (Vp) Operation Temperature -40 to 70°C
Full mode protection (L-Screen, L-Earth and Screen-E) Mounting DIN rail according to EN50022 or Screw

LINE OUT
LINE IN

High discharge current


Data Signal Protector mount (DIN rail is removable)
Continuous and repeated protection in intense environment
CCTV-BNC
Nominal Voltage - 1V | Maximum Voltage - 6.3V
Conductor Size (mm2) BNC Coaxial Female Connector
Maximum Current - 300mA | In-Line Resistance - <1Ω
Operating Bandwidth - >20MHz
Weight (kg) 250
Testing Specifications
Line Line
Line Line
In
Earth
Disconnecting screw.
To be removed for
Earth
Out
Physical Dimensions (mm)
unearthed system

System Screen

Tested to 5kV 10/700µs, accordance to From Field To Equipment

BS6651:1999, Appendix C, Cats C-High Your Preferred Lightning & Security Solutions Provider
www.tokai.com.my

ITU IX K17 (CCITT)

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

pg 06 pg 07
TOKAI ESP TOKAI ESP
Power Multi-Plug Protector Power Multi-Plug Protector
Power Surge Protector Device Installation Product Specifications
Use for Main Power Supplies for general protection of electrical and Model No TPV 240MC TPV 240 MC/TP
electronic equipment and appliances from surge transient.
Very easy to use. Just plug the 3-pin plug of the
equipment into any of the 3-pin socket provided on the Nominal Voltage Vn (RMS) 240V 240V
Suitable for all electronics or electrical equipement using 3-pin power
plug of up to 13A such as computer desktops, modems, fax machines, protector. Operational Voltage Vo (RMS) 200-270V 200-270V
printers and server units. Operational Frequency 40-60Hz 40-60Hz
Can be installed mounted on the wall and panels within an equipment
cabinet
Selection Maximum Operating Current ≤13A** ≤13A**
(unit is fused at 13A)
Protector for Single Phase Supply 220 / 230 / 240VAC, 40/60Mz.
Two versions - Standard 3 gang of 3-pin sockets or with additional The Power Multi-Plug Protector comes in two version. Leakage Current <500µA <500µA
telephone RJ11 jack protector Standard 3 Gang 3-pin socket and 3 Gang 3-pin socket Clamping or Let-through Voltage Vp
c/w Telephone Line Protector. Just indicate the model 6kV 1.2/50µs, 500A 8/20µs <560V <560V
number correctly as below:-
6kV 1.2/50µs, 3kA 8/20µs <600V <600V
Product Features Mode of Protection L-N, L-E, N-E L-N, L-E, N-E
TPV 240MC
Maintenance free. 3 x 3-pin socket
LED status indication.
Model No TPV 240 MC/TP
Mounting holes allow easy mounting on the wall, equipment cabinet
TPV 240MC/TP Nominal Voltage (D.C.) 165V
panel and computer workstations.
Can be used for equipments using up to 13A current.
3 x 3-pin socket with additional Telephone Protector Nominal Voltage (A.C.) 116V
Maximum discharge current of 10kA per mode, 20kA per unit. Maximum Continuous Operating Voltage 185V
Low let-through or clamping voltage (Vp).
Maximum Load Current 500mA
Full mode protection (L-N, L-E and N-E).
Thermal tripping device and other protection allows safety disconnect Bandwidth (3dB, 50Ω system) >12Mhz
due to faulty supplies. Power Multi-Plug Protector
Leakage Current (Nominal Voltage) 10µA
Flexible combination of 3 Gang 3-pin sockets or 3 Gang 3-pin sockets
Power Protector Specifications

Modes of Protection L-L and 2 x L-E


Operational Voltage
200 - 240Vrms
Operation Frequency
50 - 60Hz
Max. Current

with telephone line protection.


13A
Max. Discharge Current
20kA per unit

Clamping or Let-through Voltage Vp


Your Preferred Lightning & Security
Solutions Provider
www.tokai.com.my

Continuous and repeated protection in intense environment. Status

Robust metallic casing 5kV 10/700µs, 125A ITU Standard 200V


Nominal In-Line Resistance (per line) 4.7Ω

Testing Specifications Model No. TPV 240MC TPV 240 MC/TP


Single Phase Power Multi Plug Protector Max. Discharge Current (Imax) 10kA 10kA
Tested to 6kV 1.2/50µs, 3kA 8/20µs accordance to 8/20µs per mode
BS6651:1999, Appendix C, Cat A-High
Max. Discharge Current (Imax) 20kA 20kA
SS CP33:1996, Appendix F, Cat A-High
UL 1449 mains plug-in 8/20µs per phase
Operation Temperature -30 to 70°C -30 to 70°C
Tested to 6kV 1.2/50µs, 3kA 8/20µs accordance to
BS6651:1999, Appendix C, Cat B-High
Mounting Screw mount Screw mount
SS CP33:1996, Appendix F, B-High Connection Type Power-3 Square Pin Socket in Power-3 Square Pin Socket in
accordance to BS1363, MS589, SS145 accordance to BS1363, MS589, SS145
Tested to 6kV 1.2/0.5µs, 100kHz ring wave, 200A accordance to Weight (kg)
IEEE C62.41-1991 Location Cat A3 1.4 1.5
AS 1768-1991, Appendix B, Cat A Physical Dimensions (mm)

Telephone Protector (Additional Unit)


Tested to 5kV 10/700µs, accordance to
BS6651:1999, Appendix C, Cats C-High
ITU IX K17 (CCITT)

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

pg 08 pg 09
TOKAI ESP TOKAI ESP
Data Signal Protector - Part 1 Data Signal Protector - Part 1
Data Signal Protector Installation Product Specifications
Use for Data Signal and Communication Application.
Model No TDS 06 TDS 16 TDS 32 TDS 54 TDS TN
Also applicable to low current DC supply for 800mA and below. To begin it is important to select the correct protector
Protects sensitive electronics systems and equipments from Surge based on the voltage, current and bandwidth. The Nominal Voltage (D.C.) 6.7V 16V 32V 54V 165V
Transient entering the signal or comm. wires. protector is installed in seires as indicated in the Nominal Voltage (A.C.) 5.0V 11V 22V 38V 116V
Suitable for Tele-communication, Field Sensors and Transducer, Control
diagrams below. Ensure that the input (wires going away Max. Continuous Operating Voltage 7.7V 18V 36V 58V 185V
Signal, CCTV, Computer, Networking and other Systems where twisted
pair wirings are used.
from the equipment) are connected correctly to ensure Max. Load Current 850mA 850mA 850mA 850mA 320mA
Can be installed in control panel, termination panels and equipment protection. Clamping or Let-through Voltage Vp
panels.
5kV 10/700µs, 125A ITU Standard 11V 27V 46.5V 72V 210V
Protectors available for 6V, 16V, 32V, 54V and Telephone Line. Arrange the incoming and outgoing wire correctly to
Multi-stage protection provide better protection. ensure no transient goes back into the system via Nominal In-Line Resistance (per line) 1Ω 1Ω 1Ω 1Ω 4.7Ω
induction. Bandwidth (3dB, 50Ω system) 1.2MHz 12MHz 12MHz 12MHz 12MHz
Leakage Current (Nominal Voltage) 200µA 10µA 10µA 10µA 10µA
Product Features Mode of Protection L-L and 2 x L-E
Maintenance free.
Series connection.
Model No. TDS 06 TDS 16 TDS 32 TDS 54 TDS TN
Wide range of voltage selection including 6V, 16V, 32V, 54V and
Telephone Line. Max. Discharge Current (Imax) 10kA 10kA 10kA 10kA 10kA
High current limit (800mA) allow usage in wide range of system. 8/20µs per mode
Low in-line resistance of 1 ohms allow easy compatibility to applied Max. Discharge Current (Imax) 20kA 20kA 20kA 20kA 20kA
system.
8/20µs per unit
Allow high bandwidth of 12Mhz.
Metallic enclosure.
Pluggable terminal allow easy installation and replacement of the Other Specification
protector. From Field To Equipment
Operation Temperature -30° to 70°C -30° to 70°C -30° to 70°C -30° to 70°C -30° to 70°C
DIN rail mounting or panel allows easy replacement.
1 - L1 3 - L1 Conductor Size (mm2) 2.5 2.5 2.5 2.5 2.5
L1

L3

LINE OUT
TDS 32

TDS 32
Earthing via DIN Rails permitting easy installation.
LINE IN

E E
E

E
Low let-through or clamping voltage (Vp). 2 - L2 Data Signal Protector 4 - L2 Mounting (Earth Connection) DIN rail according to EN50022 or Screw Mount (DIN rail is removable)
L2

L4
Full mode protection (L-L and Both L-E). Approximate weight (g) 200 200 200 200 200
High Discharge Current.
Physical Dimensions (mm)

Testing Specifications
Tested to 5kV 10/700µs, accordance to
BS6651:1999, Appendix C, Cat C-High
ITU IX K17 (CCITT)

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

pg 10 pg 11
TOKAI ESP TOKAI ESP
Data Signal Protector - Part 2 Data Signal Protector - Part 2
Data Signal Protector Installation Product Specifications
Use for Data Signal and Communication Application.
Also applicable to low current DC supply for 3.5A and below. To begin it is important to select the correct protector Model No TDH 06 TDH 16 TDH 32 TDH 54
Protects sensitive electronics systems and equipments from Surge based on the voltage, current and bandwidth. The Nominal Voltage (D.C.) 6.7V 16V 32V 54V
Transient entering the signal or comm. wires. protector is installed in seires as indicated in the
Suitable for Tele-communication, Field Sensors and Transducer, Control
Nominal Voltage (A.C.) 5.0V 11V 22V 38V
diagrams below. Ensure that the input (wires going away Max. Continuous Operating Voltage
Signal, CCTV, Computer, Networking and other Systems where twisted 7.7V 18V 36V 58V
pair wirings are used.
from the equipment) are connected correctly to ensure
Max. Load Current 3.5A 3.5A 3.5A 3.5A
Can be installed in control panel, termination panels and equipment protection.
panels.
Clamping or Let-through Voltage Vp
Protectors available for 6V, 16V, 32V and 54V. Arrange the incoming and outgoing wire correctly to 5kV 10/700µs, 125A ITU Standard 11V 27V 46.5V 72V
Multi-stage protection provide better protection. ensure no transient goes back into the system via Nominal In-Line Resistance (per line) 0.05Ω 0.05Ω 0.05Ω 0.05Ω
induction. Bandwidth (3dB, 50Ω system) 120kHz 140kHz 150kHz 160kHz
Product Features Leakage Current (Nominal Voltage) 200µA 10µA 10µA 10µA
Mode of Protection L-L and 2 x L-E
Maintenance free.
Series connection.
Wide range of voltage selection including 6V, 16V, 32V and 54V. Model No. TDH 06 TDH 16 TDH 32 TDH 54
High current limit (3A) allow usage in wide range of system. Max. Discharge Current (Imax) 10kA 10kA 10kA 10kA
Low in-line resistance of 0.05 ohms allow easy compatibility to applied 8/20µs per mode
system.
Allow high bandwidth of 120kHz to 180kHz.
Max. Discharge Current (Imax) 20kA 20kA 20kA 20kA
Metallic enclosure. 8/20µs per unit
Pluggable terminal allow easy installation and replacement of the
protector.
From Field To Equipment Other Specification
DIN rail mounting or panel allows easy replacement.
Earthing via DIN Rails permitting easy installation. Operation Temperature -30° to 70°C -30° to 70°C -30° to 70°C -30° to 70°C
1 - L1 3 - L1
Conductor Size (mm2)
L1

L3
2.5 2.5 2.5 2.5
TDH 32

TDH 32

LINE OUT
Low let-through or clamping voltage (Vp).
LINE IN

E E
E

E
Full mode protection (L-L and Both L-E). 2 - L2 4 - L2
Mounting (Earth Connection) DIN rail according to EN50022 or Screw Mount (DIN rail is removable)
Data Signal Protector
L2

L4
High Discharge Current.
Approximate weight (g) 200 200 200 200
Continuous and repeated protection in intense environment
Physical Dimensions (mm)

Testing Specifications
Tested to 5kV 10/700µs, accordance to
BS6651:1999, Appendix C, Cat C-High
ITU IX K17 (CCITT)

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

pg 12
pg 13
TOKAI ESP TOKAI ESP
Network Signal Protector Network Signal Protector
Network Signal Protector Installation Product Specifications
Use to protect Computer Workstation, Network Hub, Servers and
Model No TSP100T-POE
Broadband Modems. To begin it is important to select the correct protector type
Protects Internet Network System using RJ45 connector type meeting the based on the different system type (2 twisted pair 4 Nominal Voltage (D.C.) 5V — 50V
requirements of Cat 3, 4, 5 and 5E from Surge Transient. twisted pair and POE). The protector is installed in series Max. Continuous Operating Voltage 7V — 58V
Suitable for all kind of computer network and Ethernet system.
using RJ45 connector type as indicated in the diagrams Max. Load Current 250mA — 350mA
Can be installed in Server cabinet, termination panels and equipment
panels.
below. Install the protector near to the equipment that it
Wide range of selection including 2 twisted pairs and 4 twisted pairs is protected. Clamping or Let-through Voltage Vp
network systems, and Power Over Ethernet (POE).
5kV 10/700µs, 125A ITU Standard (L-L) 24V — 72V
Multi-stage protection provide better protection. Ensure that the input (wires going away from the
equipment) and output (wires going towards the 5kV 10/700µs, 125A ITU Standard (L-E) <400V
equipment) are connected correctly to ensure protection. Nominal In-Line Resistance (per line) 1Ω
Arrange the incoming and outgoing wire correctly to Bandwidth (3dB, 50Ω system) 100MHz

}
Product Features ensure transient does not induce back into the system via Attenuation Meets requirements of
induction. Ensure a good earth connection. Voltage Standing Wave Ratio (VSWR)
Maintenance free. TIA Cat 5 basic link, 10/100 base TX, TIA Cat 5 channel,
Series connection. Near End Cross Talk (NEXT) IEEE 802.13.4.UTP and IEEE 802.3af
Selection of 2 twisted pair, 4 twisted pair and POE. Leakage Current (Nominal Voltage 30µA
High current limit.
Low in line resistance of 1 ohms allow maintains high signal strength.
Protection Pinning 1/2, 3/6 — 4/5, 7/8
Low capacitance design.
Meets requirement of Cat 3, 4, 5 and 5E. Model No. TSP100T-POE
Allow high bandwidth of 100Mhz.
Max. Discharge Current (Imax) 10kA
Metallic Enclosure.
DIN rail mounting or panel mount enable easy installation. 8/20µs per mode
Earthing via DIN Rails permitting easy installation.
Low let-through or clamping voltage (Vp). Other Specification
Full mode protection (L-L and both L-E).
Operation Temperature -30 to 70°C
High Discharge Current.
Conductor Size (mm2) RJ45 Socket
TSP 100T-POE

TSP 100T-POE
Continuous and repeated protection in intense environment.

LINE OUT
LINE IN

Mounting (Earth Connection) DIN rail according to EN50022 or


Network Signal Protector

Screw mount (DIN rail is removable)


Approximate weight (g) 250
Testing Specifications Physical Dimensions (mm)
Tested to 5kV 10/700µs, Accordance to:
BS6651:1999, Appendix C, Cats C-High
ITU IX K17 (CCITT)

Meets requirement of:


TIA Cat 5 basic link
10/100 base TX
TIA Cat 5 channel
IEEE 802.13.4-UTP
IEEE 802.3af

TOKAI reserves the right to make changes to the product design without prior notice due to continuous product improvement policy

pg 14 pg 15
TOKAI ESP An Award Winning Company
Lightning Strike Counter with a solid track record and portfolio!

TSLC Series Installation As the nation’s leading lightning protection


The Tokai Lightning Strike Counter is used for detecting and recording of and security solutions provider, TOKAI is
transient discharge current caused by lightning. Very easy to use. Mount the counter on top of the copper proud to provide quality products and services
It is istalled with the building’s lightning protection system to monitor the conductor or aluminium conductor. Mount four screws
amount of lightning strike to the building. onto the wall to secure the counter onto the conductor.
that protects your homes, buildings, lives and
With the records of the counter, it will allow for lightning strike record and businesses. We are the only ISO certified
for maintenance purposes.
Can be installed mounted on the wall.
lightning and security solutions provider in the
nation. Our products are registered with
Jabatan Kerja Raya and SIRIM. The products
Jabatan
Perdana Menteri

also comply to standards BS EN 50164-1, BS


7430, BS EN 50164-2, BS EN 13601.
Established in 1993, Tokai has grown from
Product Features strength to strength, winning numerous
Maintenance free. projects that have become landmarks in the
Digital counter allows easy monitoring. nation. Tokai is the dominant force in the field
Easy connection.
Mounting holes allow easy mounting on the wall.
of lightning & surge protection as well as
Counter detects discharge current ranging from 300A to 100kA. engineering security solutions.
Uses IP66 Poly Carbonate Box for weather resistance.

Tokai Group of Companies is a 100%


Malaysian owned entity. Our engineers and
technicians are highly-trained with vast project
experience to ensure total customer
satisfaction. Tokai's name is synonymous with
Product Specifications quality and excellence.
Model No TSLC2000
Please visit our website for more details.
Transient Current Range 300A - 100kA
Counter Display LCD Screen, 0 - 9999999 counts
Lifespan (estimated) 5 years www.tokai.com.my
Operation Temperature -30° to 70°C

TOKAI’s complete range of solutions includes:


Mounting Wall Mount
Weight (kg) 0.30
Physical Dimensions (mm) 80 x 110 x 70

WELD E&LP
Tokai Integrated Safety, Exothermic welding Earthing and Lightning
Security and Management products for permanent Protection (E&LP) range of
to protect people, assets connection process. products that are certified