VACUUM PUMP & BOOSTER PUMP CAPACITY CALCULATION BASED ON AIR LO

INPUT DATA INPUT OPERATING DATA

Vacuum Leak 90 Torr System Operating temperature 350

Evacuation time 10 mins Air Load 3

System Volume 4 Cu.m Required Ultimate Pressure 10

Vacuum Pump Capacity Required Booster Pump C

Pump Capacity 216 Cu.m/Hr Booster Capacity

Line Size from Pump to System 1.39 inch Line size from pump to bo
ngineering
ATION BASED ON AIR LOAD AND LEAKAGE RATE

G DATA OUTPUT DATA

°K
Torr.Lit/
Air-Leakage Rate, Q 600.00
Sec
Kg/hr

Torr

Booster Pump Capacity Required

Booster Capacity 227.11 Cu.m/hr

Line size from pump to booster 1.42 inch