FIELD INSPECTION REPORT

PLTU KALIMANTAN SELATAN (2x65 MW) PROJECT


CONSORTIUM WIKA - CHENGDA PT. PLN
OIL FLUSHING TEST REPORT
OWNER : PT.PLN (Persero) FILE No :
MAIN CONTRACTOR : CONSORTIUM WIKA - CHENGDA FORM ID :
PROJECT : PLTU KALIMANTAN SELATAN 2 x 65 MW PROJECT
LOCATION : TURBINE UNIT #3
WORK ITEM : Oil Flushing For Turbine Unit #3
DWG REFERENCE : YG-F2906S-J0301-19
DATE : 30 /07/2011

PRESSURE LINE RETURN


NO. DATE TIME
NAS % SAT NAS % SAT
1 22 July 0:15 5.7 51.3 4.3 47.4
2 22 July 11:15 6.4 51.8 4.7 45.7
3 22 July 16:00 5.7 44.3 5.7 44.2
4 23 July 10:45 7.5 45.0 2.8 38.8
5 23 July 19:45 4.7 41.7 3.5 36.7
6 24 July 16:15 2.7 36.7 3.6 35.6
7 24 July 20:00 2.8 35.8 2.6 35.1
8 25 July 0:15 4.5 37.5 4.0 39.7
9 27 July 1:00 5.2 56.2 5.1 55.5
10 27 July 14:00 3.7 43.7 4.9 40.4
11 27 July 19:00 5.3 43.0 4.8 40.6
12 28 July 1:00 4.2 42.3 5.2 40.5
13 28 July 11:00 4.3 39.0 3.9 43.6
14 28 July 16:00 4.7 38.2 3.5 36.0
15 29 July 1:00 4.9 38.3 5.8 36.0

OWNER SUPERVISOR CONTRACTORS


PT.PLN PT. REKADAYA ELEKTRIKA CONSORTIUM WIKA-CHENGDA
Witnessed by, Approved by, Reviewed by, Prepared by,
Date : Date : Date : Date :