APPLICATION FOR UNIT RENOVATION

NAME OF PROPERTY

NAME OF BUILDING

UNIT NUMBER

NAME OF UNIT OWNER


(Please check desired renovation works) Requirement & Comments
Minor – Class A
 Replacement of lavatory, faucets and shower heads. Must fit the existing provision.
 Any decorations, furnishings and accessories to be mounted / installed on Use of concrete nails for mounting is not allowed.
partition walls.
 Interior painting Use odorless and water-based paint only.
 Wallpaper installation All wallpaper installation is allowed.
 Installation of window- type air conditioner to the designated location. Must not exceed existing capacity, must match wall opening
provided. No chipping works.
 Installation of split- type air conditioner between 1-2 HP at designated location. Maximum is 2HP capacity.
 Installation of split- type air conditioner between 1-2 HP (for units without split- Mounting should be on CHB walls only. Must have unit balcony to
type air conditioner provision). place condenser unit.
 Installation of single- point water heater at the designated location Maximum 3.5kW capacity.
 Installation of single- point water heater at not designated location. Shall be surface mounted only.
 Installation of installation of digital lock set and/or dead bolt at unit main door. Standard Door Screen is required to be installed. Use DMCI- PDI
door screen design.
 Replacement of interior door, interior door frames, locksets and installation of Specification matches jamb.
dead bolt (Inside the unit).
 Installation of grills and door screen. Must follow the DMCI- PDI standard details.
 Installation of shower enclosure. Max. height of 1.80m from top of zocalo with min. 400mm clear
opening from top of shower enclosure to ceiling.
 Installation of doorbell at unit entrance. Must be wireless only. Doorbell color shall be predominantly white.
Minor – Class B
 Replacement of kitchen cabinet and granite countertop. No changes shall be made on existing MEP layout.
 Replacement of exterior door and windows. Must retain same design and specifications and paint finish.
 Retiling of living room, dining room, kitchen and bedroom. To be done by tile adhesives only.
 Installation of closets and shelves, provided that no sprinkler or wiring devices Works under any sprinkler must have a maximum height of 2.10m
and fixtures are obstructed. from finish floor line.
 Installation of drop ceiling and cove lighting. Maximum drop from under slab is 100 mm.
 Additional wiring devices. Must not exceed allotted load BUT shall void warranty on electrical
system.
Major
 Replacement of bathroom fixture (water closet, under counter lavatory, wall No chipping works on slab, beams columns and CHB partition walls.
hung lavatory only). Relocation not allowed.
 Retiling works at T&B. Tile over tile method only: no chipping works allowed on existing
T&B walls and flooring.
 Removal of drywall partition. Max. height of wall allowed to be removed must be 2.40m only.
 Re-layout and installation of new drywall partition. Fire detection system and sprinkler heads shall not be obstructed.
 Extended / garden balcony roofing installation or rehabilitation works. Follow standard roofing material, connection details and
specifications.
 Any CHB / concreting works (e.g. concrete bar counter, breakfast nook, sink Pre-cast works only. Wet works are not allowed.
counter, vanity counter, etc.).
 Loft bed / floor No space shall be left unprotected and without fire sprinkler
coverage.
Attach are the documents as required in the RENOVATION GUIDELINES. In undertaking the upgrade/renovation, I hereby agree to all conditions
stipulated therein.

______________________________ ____________________________
Name of Unit Owner Date
(sign over printed Name)

EVALUATION & APPROVAL (for DMCI –PDI Design and Engineering Use Only)
RENOVATION CLASSIFICATION

Minor - Class A Minor - Class B Major

______________________________ ______________________________ ____________________________


Name of Facilities Officer Name of Property Manager Date
(sign over printed Name) (sign over printed Name)

Approved as Noted Approved as Corrected Revise and Resubmit

Remarks & Comments:

_________________________________________________________________________________________________________________
Signatories:

_____________________________________ _____________________________________
Design Assistant/ Architect Facilities Manager (CAS)
(sign over Date) (sign over Date)

PM-FM-001.R1 APPLICATION FOR UNIT RENOVATION