You are on page 1of 2

14.02.

2023
New Side Housing LH & RH 12.02.2023
Issue - Cold Patch.
Spec- 1420 to 1440C
Heat No On Casting LH Casting RH Casting Pouring Temp. Heat code on Log sheet
39-1 OK OK 1429-1433
39-2 OK OK
40-1 OK OK 1433-1438 44
40-2 OK OK 44
41-1 OK OK 1429-1433 45
41-2 OK OK 45
42-1 OK OK 1435-1437 46
42-2 OK OK 46
43-1 Cold Patch OK 1428-1431 47
43-2 Cold Patch OK 47
44-1 Heat no Not Found 48
44-2 Heat no Not Found 48
45-1 Cold Patch OK 1426-1428 49
45-2 Cold Patch OK 49
46-1 Cold Patch OK 1429-1433 50
46-2 Cold Patch OK 50
46- Cold Patch Cold Patch
1. Heat Code on Casting and on log sheet is different - Major Issue.
2. Cold Patch found on LH hsg -7 nos where as on RH Hsg -1 no.
3. Casting of Heat code 44 - not observed
LH RH

2 1

1 2

A
a

1 C 2 c

b
B
INGATE d
D
Ingate Size @ 1 A B C D
LH 22.2 14.3 26 42
RH 25 16.5 29 38.5
∆ RH -LH 2.8 2.2 3 -3.5
Ingate Size @ 2 a b c d
LH 14.5 15.5 25.5 33.5
RH 20 20.4 29 31.5
∆ RH -LH 5.5 4.9 3.5 -2
Found Ingate Size of LH side hsg is less than RH side hsg.