1.Subject
Information of NCM-2150 startup failure

2.Objective Equipment
The following NCM-2150 CONTROLLERS shipped from November 2020 to January 2022.

Serial No. BJ60861~BJ61999、BJ62001~BJ62096、BJ62098~BJ62105、BJ62107~BJ62165


BJ62167~BJ62178、BJ62186~BJ62218、BJ62220~BJ62257、BJ62259~BJ62282
BJ62284~BJ62291、BJ62293~BJ62296、BJ62299~BJ62335、BJ62337~BJ62347
BJ62349、BJ62351~BJ62352、BJ62355~BJ62356、BJ62361、BJ62363~BJ62367
BJ62370~BJ62379

3.Outlines
(1) Phenomenon
In rare cases, some units of the NCM-2150 CONTROLLER may not start.
Note: In case of startup failure, restart the power supply to recover.

Backlight only

Normal Failure

(2) Countermeasure
Replace the CMV-3775 (code: CMV-3775) in the NCM-2150 only when startup failure occurs.
Note: The NCM-2150 shipped after February 2022 has already received the
countermeasure.