You are on page 1of 4

SOLUTIONS SUPPORT DIVISION

Bulletin Number 7225

Date: 12/03/09
From: SSD
Subject: Service Manual Update
bizhub PRO 950: 009

Please make the following corrections to your bizhub PRO 950 Field Service Manual.
Revision history
After publication of this service manual, the parts and mechanism may be subject to change for
improvement of their performance.
Therefore, the descriptions given in this service manual may not coincide with the actual machine.

When any change has been made to the descriptions in the service manual, a revised version will be
issued with a revision mark added as required.

Revision mark:
• To indicate clearly a section revised, 1 is shown at the left margin of the revised section.
The number inside 1 represents the number of times the revision has been made.

• To indicate clearly a page that contains the revision, 1 is shown near the page number of the
corresponding page.
The number inside 1 represents the number of times the revision has been made.

NOTE
Revision marks shown in a page are restricted only to the latest ones with the old ones deleted.
• When a page revised in Ver. 2.0 has been changed in Ver. 3.0:
The revision marks for Ver. 3.0 only are shown with those for Ver. 2.0 deleted.
• When a page revised in Ver. 2.0 has not been changed in Ver. 3.0:
The revision marks for Ver. 2.0 are left as they are.

2009/11 2.01 Revision in relation to change of description


Revision due to the addition of a new option (GP, MK).
2009/09 2.0 1 Addition of relay connector layout.
2009/01 1.0 — Issue of the first edition
Date Service manual Ver. Revision mark Descriptions of revision
Field Service Ver.2.0 Sep. 2009 13. MALFUNCTION CODE

Classifica- Code Causes Resulting Estimated abnormal parts

bizhub PRO 950


tion operation
Main body Motor C-2110 It is checked that the home posi- The main body Confirmation of the wiring
abnor- tion search time of the transfer stops immedi- harness and the connector
mality assist motor (M25) is out. ately to turn OFF Transfer assist motor (M25)
When the transfer assist home the main relay Transfer assist home sensor
sensor (PS64) is turned OFF, (RL1). (PS64)
PS64 is not turned ON a speci- ADU drive board (ADUDB)
fied period of time after the home DC power supply /1
position search starts operation. (DCPS1)
C-2111 While the transfer assist motor Power supply cooling fan /1
(M25) is in operation, an error is (FM30)
detected. Power supply cooling fan /2
An error is detected of the trans- (FM31)
fer assist motor (M25) while in the
print operation.
C-2201 The speed error signal of the Confirmation of the wiring
toner bottle motor (M15) is harness and the connector
checked. An error detection sig- Toner bottle motor (M15)
nal is detected twice in succes- Printer control board (PRCB)
sion a specified period of time
after M15 turns ON (the first sig-
nal is ignored).
C-2202 The speed error signal of the Confirmation of the wiring
developing motor (M3) is harness and the connector
checked. Since an error detection Developing motor (M3)
signal is detected a second after Printer control board (PRCB)
M3 turns ON, turn OFF M3 for a
specified period of time. Then, an
error detection signal is detected
again a specified period of time
after it is turned ON again.
C-2203 The locking of the blade motor Confirmation of the wiring
(M14) is detected. The error harness and the connector
detection signal (over current) of Blade motor (M14)
M14 is detected. Printer control board (PRCB)

429
13. MALFUNCTION CODE Field Service Ver.2.0 Sep. 2009

Classifica- Code Causes Resulting Estimated abnormal parts


bizhub PRO 950

tion operation
Fan C-5330 The rotation of the power supply The main body Confirmation of the wiring
Main body

abnor- cooling fan /3 (FM32) is checked. stops immedi- harness and the connector
mality An abnormal condition occurs ately to turn OFF Power supply cooling fan /3
with the FM32 EM signal a speci- the main relay (FM32)
fied period of time after FM32 is (RL1). DC power supply /2
turned ON. This abnormal condi- (DCPS2)
tion recurs even a specified
period of time after FM32 is
turned OFF and then ON again,
and an error detection signal (24V
cut off) is not detected.
Scan- C-6101 The scanner home sensor (PS5) Confirmation of the wiring
ner does not turn ON within a speci- harness and the connector
abnor- fied period of time after the home Scanner motor (M13)
mality position search is started. Scanner home sensor (PS5)
Scanner drive board (SDB)
Printer control board (PRCB)
DC power supply /2
(DCPS2)
Fan C-6301 The rotation of the scanner cool- Confirmation of the wiring
abnor- ing fan (FM7) is checked, and harness and the connector
mality 24V power source is also Scanner cooling fan (FM7)
checked. An abnormal condition Scanner drive board (SDB)
occurs with the FM7 EM signal a Printer control board (PRCB)
specified period of time after FM7 DC power supply /2
turns ON. This abnormal condi- (DCPS2)
tion recurs even a specified
period of time after FM7 is turned
OFF and then turned ON, and an
error detection signal (24V cut off)
is detected.
Image C-6701* When processing images, a filter If there is a Confirmation of the wiring
pro- coefficient cannot be created nor- sheet of paper harness and the connector
cess- mally. being printed, Reinstalling firmware
ing the main body Overall control board (OACB)
abnor- completes the
mality paper exit
before stopping
operations. The
main relay (RL1)
is turned OFF.