Professional Documents
Culture Documents
Date: 12/03/09
From: SSD
Subject: Service Manual Update
bizhub PRO 950: 009
Please make the following corrections to your bizhub PRO 950 Field Service Manual.
Revision history
After publication of this service manual, the parts and mechanism may be subject to change for
improvement of their performance.
Therefore, the descriptions given in this service manual may not coincide with the actual machine.
When any change has been made to the descriptions in the service manual, a revised version will be
issued with a revision mark added as required.
Revision mark:
• To indicate clearly a section revised, 1 is shown at the left margin of the revised section.
The number inside 1 represents the number of times the revision has been made.
• To indicate clearly a page that contains the revision, 1 is shown near the page number of the
corresponding page.
The number inside 1 represents the number of times the revision has been made.
NOTE
Revision marks shown in a page are restricted only to the latest ones with the old ones deleted.
• When a page revised in Ver. 2.0 has been changed in Ver. 3.0:
The revision marks for Ver. 3.0 only are shown with those for Ver. 2.0 deleted.
• When a page revised in Ver. 2.0 has not been changed in Ver. 3.0:
The revision marks for Ver. 2.0 are left as they are.
429
13. MALFUNCTION CODE Field Service Ver.2.0 Sep. 2009
tion operation
Fan C-5330 The rotation of the power supply The main body Confirmation of the wiring
Main body
abnor- cooling fan /3 (FM32) is checked. stops immedi- harness and the connector
mality An abnormal condition occurs ately to turn OFF Power supply cooling fan /3
with the FM32 EM signal a speci- the main relay (FM32)
fied period of time after FM32 is (RL1). DC power supply /2
turned ON. This abnormal condi- (DCPS2)
tion recurs even a specified
period of time after FM32 is
turned OFF and then ON again,
and an error detection signal (24V
cut off) is not detected.
Scan- C-6101 The scanner home sensor (PS5) Confirmation of the wiring
ner does not turn ON within a speci- harness and the connector
abnor- fied period of time after the home Scanner motor (M13)
mality position search is started. Scanner home sensor (PS5)
Scanner drive board (SDB)
Printer control board (PRCB)
DC power supply /2
(DCPS2)
Fan C-6301 The rotation of the scanner cool- Confirmation of the wiring
abnor- ing fan (FM7) is checked, and harness and the connector
mality 24V power source is also Scanner cooling fan (FM7)
checked. An abnormal condition Scanner drive board (SDB)
occurs with the FM7 EM signal a Printer control board (PRCB)
specified period of time after FM7 DC power supply /2
turns ON. This abnormal condi- (DCPS2)
tion recurs even a specified
period of time after FM7 is turned
OFF and then turned ON, and an
error detection signal (24V cut off)
is detected.
Image C-6701* When processing images, a filter If there is a Confirmation of the wiring
pro- coefficient cannot be created nor- sheet of paper harness and the connector
cess- mally. being printed, Reinstalling firmware
ing the main body Overall control board (OACB)
abnor- completes the
mality paper exit
before stopping
operations. The
main relay (RL1)
is turned OFF.
454