Actuators
SPECIFIC TECHNICAL UNIT
Specifications
Service Arctic, CO2 and Limited H2S
Maximum Control Pressure:
Mounted on 5" valve .026 x valve pressure + 5 psi
Mounted on 6" valve .030 x valve pressure + 5 psi
Maximum Operating Pressure 250 psi 17 Bars
Safety Head Maximum Working Pressure 270 psi 19 Bars
Test Pressure 405 psi 28 Bars
Temperature Range -75 F to +180 F -59 C to +82 C
Product Weight (Dry) 900 lbs 408 kg
THIS DOCUMENT CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION WHICH IS THE PROPERTY OF CAMERON, AND RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO LOAN, SELL OR OTHERWISE DISCLOSE SAID
INFORMATION. REPRODUCTION OR USE OF SAID INFORMATION FOR ANY PURPOSE OTHER THAN THE PURPOSE FOR WHICH SAID INFORMATION WAS SUPPLIED IS PROHIBITED WITHOUT EXPRESS WRITTEN PERMISSION FROM
CAMERON. THIS DOCUMENT IS TO BE RETURNED UPON REQUEST OR COMPLETION OF THE PURPOSE FOR WHICH IT WAS SUPPLIED.
Pneumatic Actuator Unit No. 7B-TU-885092006 Date: Aug. 17, 2010
Rev. 01 Page 2 of 3
WARNING
Use of Cameron equipment contrary to
manufacturer’s specification may result in
property damage, serious injury or fatality.
Pneumatic Actuator
Drawing No. 7B-71275300 Page 1
Material No.
7B-885092006
Pneumatic Actuator Unit No. 7B-TU-885092006 Date: Aug. 17, 2010
Rev. 01 Page 3 of 3
Drawing No. 7B-71275300 Page 2
Pneumatic Actuator