Professional Documents
Culture Documents
Fire Dampers 03
M.S.F.D. s 04
Sound Attenuators 05
Acoustic Louvers 06
Weather Louvers 07
Access Doors 10
Plenums,Diffusers,Grills 11
Filters 13
Duct Heaters 14
BETEC CAD.
Fire Rated Ducts 15
INDEX
STL - B 11A
Standard Types and Models
BT08.1
Item Series Type Model Material Options Blade
A - Exposed* Plain*
1-100*
B - 10* B - Duct Mounted A*, G, S + Filter Square
2-150 C - Flushed + Filter + Damper
STL
A - Exposed Plain
1-100
B - 20 B - Duct Mounted A, G, S + Filter Curved
2-150 C - Flushed + Filter + Damper
Note
* BETEC standard construction.
S Stainless steel construction is for special applications like offshore works.
All models of Sand Trap Louvers are available in Aluminum*, G.I.- galvanized sheet steel coating to Z-
22 to Z-27 to the standards JIS 3302 or BS 2989, stainless steel to 304 2B, 316L in finish construction,
according to the design conditions.
The respective suffix will indicate the type of material construction. A* - Aluminum, G - Galvanized steel
sheet S - Stainless steel (Standard construction is A - Aluminum)
BETEC Sand Trap louver's construction confirms to ADC 1602 standard and DW 142 class C.
Sand louvers offer effective barrier to weather and moderate pressure drop are maintained even
in variable weather conditions.
BETEC Sand louvers are strong and rigid in construction and are suitable for both industrial and
commercial applications.
Sand trap louvers are designed to separate sand and dust particles from intake air for ventillation applications.
Sand trap louver is provided with a self-emptying base through which the filtered sand is drained out easily.
A Bird* screen model S10 is fixed on the rare side of the STL in standard construction. Fly screen S3 is
optional.
BETEC provides easily removable aluminum filter assembly of thickness 12* / 25 / 50mm for additional fine
filtration.(Optional)
Sand louver construction reduces the risk of flooding or water pouring down the face of the louver assembly.
Once installed the individual blades cannot be removed thereby giving excellent security properties to the louver
assembly.
1. STL B-11 A / 11 B
Exposed type with Square Blade
STL - B 11A
2. STL B - 11 C
Flushed type with Square Blade
STL - B 11C
STL - B20 Series
3. STL B - 21 A / 21 B
Exposed type with Curved Blade
STL - B 21A
4. STL B-21 C
Flushed type with Curved Blade
STL - B 21C
Sand Trap Louvers B-11 Medium duty and B-12 Heavy duty model construction, are suitable for the
duct or wall mounting applications in HVAC systems, where excessive intake air filteration is required
for ventilation purpose.
Sand Trap Louvers fitted with filters and dampers are suitable for the AHU's applications for fresh air
intake.
Sand Trap Louvers B-21 Medium duty and B-22 Heavy duty model construction, are suitable for the
duct or wall mounting applications in HVAC systems, where filtered air intake is required for ventilation
purpose.
c Sand Trap Louvers fitted with filters and dampers are suitable for the AHU's applications for fresh air
intake.
STL - Multiple Assembly Construction for Fresh Air Intake of AHU Applications
Sand Particles
Stages % Efficiency
Microns
Stage 5 10 - 50 96%
Note: Typical efficiency performance is observed and recoreded with practical tests done on various sites.
By BETEC CAD.
Overall Pressure Drope ∆Pt. of the complete system is noted 80 - 100 Pa. ( At Vf = 1 mt./sec.
Selection tables
Effective pressure areas Ak in met2 For Model STL B 10 Series / 20 Series standard construction.
wxh
300 450 600 750 900 1050 1200 1350 1500
mm
300 0.028 0.043 0.059 0.073 0.089 0.104 0.118 0.133 0.148
450 0.043 0.066 0.089 0.112 0.134 0.157 0.180 0.203 0.225
600 0.059 0.089 0.119 0.150 0.181 0.258 0.241 0.272 0.302
750 0.073 0.112 0.150 0.118 0.226 0.264 0.303 0.341 0.379
900 0.089 0.134 0.181 0.226 0.273 0.318 0.365 0.410 0.457
1050 0.096 0.145 0.196 0.246 0.296 0.345 0.395 0.444 0.495
1200 0.011 0.169 0.226 0.284 0.341 0.399 0.457 0.514 0.572
1350 0.126 0.191 0.257 0.322 0.387 0.452 0.518 0.583 0.648
1500 0.141 0.214 0.287 0.360 0.433 0.506 0.579 0.653 0.725
Face Velocity 0.5mt/s 1.0 mt/s 0.5 mt/s 1.0 mt/s 0.5 mt/s 1.0 mt/s
Particle Size 150 - 700 150 - 700 75 - 150 75 - 150 10 - 100 10 - 100
l
12
ST
% Efficiency
120 60 L
1/
B-
2
1/1 Mo
-1
de 11
-1
100 50 lS /12
LB
TL +F
B
B-
L
80
ST
40
ST
11
/
l
12
de
de
60 30
Mo
Mo
40 20
20 10
0.5 1.0 1.5 2.0 2.5 3.0 3.5 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Face Velocity m/sec Face Velocity m/sec
el S
140 70 TL
% Efficiency
F
B -21
+
Mo
d /22
22
120 60 el S +F
TL
2
1/
1/2
B -21
-2
100 50 /22
-2
B
B
TL
80
TL
40
lS
lS
de
30
de
60
Mo
Mo
40 20
20 10
0.5 1.0 1.5 2.0 2.5 3.0 3.5 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Face Velocity m/sec Face Velocity m/sec
Concrete Wall
Concrete Wall
Air Flow
Note:
Fixing Details - Standard supply Concealed type Scew Fixing
Recommended for sidewall applications
Ordering Data
Acoustic Louvers