You are on page 1of 8

17 18 19 20 M ORFE LACST ONO

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 G NIWARDS IHT A

DBCDEFGHJKLM
17 18 19 20
A
21 22 23

200: Shell Cassettes Corner Node - Type


230-60
Indicate the applicable bays. Note that there are multiple
drawings for
(see Table 1)

Rectangular Hollow Sections node 230-60. Differentiate for clarity.


Center Truss 150

Slotted for Connecting Plate Fin plates at center truss Sc. 1:5 Detail Type
230-6030
a
Stool is irrelevant for this BVertical section a-a

PW ́t so
Rectangular Hollow Sections

drawing. Consider removing. b Center Truss


P

Clarify distance. eSlotted for Connecting Plate


0W 5 s
1 15 (see Table 1)
0

Typ.
0
s 2u 3r n D ́ T
(see Table 1) Ce n t Section b-b
iWr ́e l t 0 an
er m Tin m r u3 ss 20
32one in g
W Steel plate 30mm C Consider producing as assembly in the
workshop. CSteel Plate 30mm
Rectangular Hollow Sections Center Truss
nter Truss Web Dia
Rectangular Hollow Sections Center Truss eb Diagonal ́WD ́ mCe Vertical Steel Plate
welded on site
35
35 470
(see Table 1)
D
Center Truss Bottom Chord ́BC ́
min 650
min 650Rectangular Hollow Sections
Center Truss aw=12mm
Slotted for Connecting Plate
Stool required for production has to be (see Table 1)
removed before application of thermal sprayed aluminum corrosion protection
Openings to be closed with
Horizontal Steel Plate non-structural 10mm plates, aw=3mm

Clarify method of corrosion protection of inaccessible


Vertical Steel Plate
25
1
welded on site

2
00
surfaces in void. c EConsider applying full
penetration joints, done in
c workshop. Not easily 12
20 20

12 accessible for field weld.


Fin Plate extended
Side Plates Shell Cassette
50
1
50

30 0 0
8 9
Center Truss Bottom Chord ́BC ́
00
2

dd
500

Center Truss Bottom Chord ( BC-1, BC-2 ) to be produced as approximately 12m 525elements. Flanges are to be bent
at intersection points and the flanges are to be cut
525
0
9
with CNC correspondigly and welded according to Drawing WSS-STR-DWG-02-900-XX-3005001.
Vertical Connecting Plate will be produced with an extra length of +50mm at the Shell Cassette side and will be
adjusted before erection as per site survey.
F G
Concrete Panel Shell Cassette

Currently at review status Check if "webs"? 'C'. See and


address comments.
H
b bSection c-c
a
Concrete Panel Shell Cassette
J
Verify. Leader does not Kpoint at vertical plates.
Horizontal Steel Plate
Vertical Steel Plates welded on site

Consider a size above code minimum. LFin Plates extended


500

500

Mc c
w
a

a
a 0 05NO2020 40 2020
a120 b PInclude report #000082. i 01 QC-09-600-2510 C-09-600-2516
Mladen Markovic Zachary Christian Lucio Blandini 00
R 500
d
d
Verify width of the bottom chord flange.
120 2020 40 2020
Section d-d
40

a
30Rectangular Hollow Sections
Center Truss
00 0
5

50 0
3 8 Verify. Leader does not point at vertical plates.M30 preloaded
ASTM F3125M
grade A490 bolt assemblies
056n i
mVertical Connecting Plates Vertical Connecting Plates
Side Plates
Vertical Connecting Plates
Shell Cassette min 650
min 650 Fin Plates Shell Cassette

0 0 Principle comments for status:


4 4

- Please refer to comments in blue.


Side Plates Shell Cassette
Primary observations
0 56n i
m01.
Models checked against latest submissions:
Side Plates Shell Cassette

AEC models submitted 15/10/2019


Rectangular Center Truss
Hollow Sections
LKW-STR-MOD-900001 LKW-STR-MOD-900002 submitted submitted
12/09/2019. 14/10/2019.
Consider denoting vertical steel plates. LKW-STR-MOD-900003
submitted 19/05/2019. Update reference.
General comments:
30
i. Intention of the note is unclear, please clarify or remove. It is Contractor
responsibility making sure all dimensions are co-ordinated with the approved
geometries.
Specify applicable
40

bays in a drawing title.


2 WSS-STR-DWG-02-900-XX-3052015 WSS-STR-DWG-02-900-XX-3072002C Revise and Resubmit
This check is for general compliance with the design intent and does not relieve the Contractor of his obligations under the Contract.

NotationWeld Symbols
Date: By:

Additional Symbols
Side Plates

Fin Plates
M30 preloaded ASTM F3125M
Vertical Connecting Plates
Shell Cassette
Shell Cassette
grade A490 bolt assemblies Fillet Weld aw Throat
Tickness here:
Double
Fillet Weld
a
w
aw
aw Throat
here:
around Weld-all-
Tickness NV-Groove
Double V-Groove
Field Weld
w
aBevel Groove
w
Double Bevel Groove aaw; lw

aw: Weld thickness Olw: Weld length


Proposed details considered as contractor's preferred approach.
Double
Y-Groove
w
aY-Groove
w
aSpot
checks have been undertaken for general compliance with Design reports
and Tender intent only. Contractor fully responsible.
NOTE: Acceptance is subject to resolution of comment on the design report
Non-sturctural 10mm cap plates to be welded on open tube #288.
ends, with fillet weld, aw=3mm

P1. Address comments in design report WSS-STR-REP-000288-


currently at status 'C'. Clarify transverse tolerance if any.
This detail applies to all connections between the center truss bottom chord and the
shell cassettes for axes 07-09 2. Ensure full coordination with CMES. 3. Provide
repair to TSA surfaces after site welding. Restore corrosion protection to other
element.
This drawing provides general information only. For exact 4. Submit WPS/PQR.
dimension for construction please refer to 3D Tekla Model.
General Notes:
ALL LEVELS IN [m]. ALL DIMENSIONS IN [mm].

SEE GENERAL NOTES WSS-STR-DWG-02-900-XX-0100001 QGENERAL NOTES:


MATERIAL
CONTRACTOR
reference dwgs: WSS-STR-DWG-02-900-XX-3052001
REVISIONS
ff.
Multidisciplinary coordination for the content and the engineering solutions in the drawing has been performed.
No Date Description PROJECT
Originator Checked Verified CLIENT
DRAWING TITLE

ACTION STAMP
A0
DRAWING IS TO BE READ IN CONJUCTION WITH RELEVANT SPECIFICATIONS AND ARCHITECT'S
DRAWINGS. CONTRACTOR'S DRAWINGS, GEOMETRY AND INTERFACES HAVE TO BE ADAPTED TO
ARCHITECTS FINAL DRAWINGS.
New Passenger Terminal (Terminal II) SPA/214
DO NOT SCALE FROM DRAWINGS, ONLY FIGURED DIMENSIONS TO BE USED.
ENGINEER PROJECT BASE POINT AND PROJECT NORTH
WSS-STR-REP-000032 TO BE VERIFIED WITH ARCHITECTURAL
WSS-STR-REP-000288
ACTION STAMP
ENGINEER'S REPRESENTATIVE
SCALE

PAPER 30/09/2019
1:5
SIZE

STRUCTURE - Terminal Building


STRUCTURAL STEEL:
DEV. STAGE STRUCTURAL STEEL PLATES (THICKNESSES 4-100MM)

IFC
ACONEX MODEL REF.
A572M GRADE 345 UNO
contract dwg no:
CONTRACTOR'S CONSULTANT HOT-FORMED HOLLOW STRUCTURAL SECTIONS A501M GRADE B UNO
SIGN OFF DATE:
ALL STEEL SHALL BE SUPPLIED IN ACCORDANCE WITH ASTM A6M AND A36M STANDARDS.
Foster + Partners
Agreement No. A/SPA/232

Architect
00 30/09/2018

First issue -For approval mar chr bl KUWAIT INTERNATIONAL


AIRPORT Structural Eng.
Lucio Blandini Riverside, 22 Hester Road
DRAWING STATUS London SW11 4AN
Gulf Consult
Supervision of Package 1 Kuwait International Airport
LOD 400 WIP

200: Shell Cassettes


Site Office
Terminal 2
Mechanical Eng. Fethi Akalin Electrical Eng.
Mehmet Koclar
Design Director
Izzet Fikirlier T +44 (0)20 7738 0455 F +44 (0)20 7738 1107
AEC-BIM-MCO-02-900-XX-0220140

Corner Node
IN ASSOCIATION WITH:
AEC-BIM-MCO-02-900-XX-0220240 AEC-BIM-MCO-02-900-XX-0220340

Type 230-60
akkah
M
LKW-STR-MOD-900001

17/10/2019 F+P/GC 29.08.2019 design report:


SIGNATURE DATE
R
DRAWINGS.
N
CONTRACTOR
13085 P.O. T +965 Box Kuwait
24843565
22412, Safat

-
F www.gckuwait.com +965 24849532 -
ORIGINATOR
CHECKED BY
VERIFIED BY
NAME
NAME NAME
NUMBER: SHEET

WSS-STR-DWG-02-900-XX-3052215
REVISION
DATE 30/09/2019
DATE 30/09/2019 DATE
30/09/2019
NAME: SHEET

200: Shell Cass._Corner Node Type 230-60


1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 21 22 23
Corner node fabrication
Central node junction is required to develop the full tensile strength of the node plates in either direction.
An automated and repeatable manufacturing process (casting or fabrication) shall be adopted to ensure consistent
tolerances and specified performance.
The manufacturing process for node shall ensure specified tolerances on erected geometry are met without requiring
shims, packs or excessive distortion of panel frames.
Design assumes complete joint penetration (CJP) welding of four plates simultaneously using the narrow gap improved
electroslag welding process (NGI-ESW).
Welding procedures shall be verified by hardness tests on run-on/run-off strips and by visual, MPI and ultrasonic
testing in accordance with the specification.
All bolt holes to be set out on vertical plane on centre line of joint
In order to allow the correct executions of the electroslag welding process the bottom edge of the different fin plates
must have to be revised as shown in the present drawings
All panel connections are slip critical (SC) and shall use M30 ASTM F3125M grade A490 preloaded bolt assemblies.
Short-slots as per standard AISC 360 (33x40) Minimum fastener tension 408 kN in accordance with AISC 360-05
Table J3. 1M. Faying surfaces to achieve minimum design slip value of 0.45. Minimum bolt pretension 408 kN (As per
AISC 360-16 Table J3.1M) Bolt pretensioning method: Direct tension indicator method
Fin Plate Types refer to WSS-STR-DWG-02-900-XX-3052015
Corner Node Type - Overview refer to WSS-STR-DWG-02-900-XX-3072002
w w
a a