You are on page 1of 1

AXIS OF H/R

NOTES:
10500 3000 8000 6000
1. All dimensions are in millimeter unless otherwise mentioned & levels in meter . Only written dimensions
are to be followed.
FLOW 2. 25 mm premoulded bituminous expansion pad shall be provided at expansion joint.
5750 3. Position of Returnwalls, Railings, Guard post, shall be decided by Engineer in charge.
R.L +57.15 3750 4. Water spouts of 100mm dia G.I pipe are provided @ 3 m c/c.
R.L +56.50
R.L +54.90 R.L +54.90
5. Concrete shall have minimum 28 days characteristic strength on 150 mm cubes for elements of
superstructure shall be 20Mpa.
VERTICAL JOINT 6. High strength O.P.C should be used of 43 Grade conforming to IS: 12269.
WITH SEAL
R.L +54.00
7. All reinforcement bars shall be HYSD Fe-500 conforming to IS:1786-2008.
POND LEVEL R.L +53.00 CHUTE BLOCK 8. Cover in deck slab is 40 mm.
1200x1200x600 MM CC Block 1200 mm Thick Crated
1200x1200x600 MM CC Block with 50 mm thick joints in between Boulder Pitching
9. Available suitable steel sheet pile conforming to I.S2314-1986.
FRICTION BLOCK
with 50 mm thick joints in between Pitching over 300 mm Graded Filter 10. R.C.C Work shall be conform to IS 456-2000.
Pitching over 300 mm Graded Filter R.L +51.00 11. The section of various component may be adjusted as per site
2:1

750
3:1
R.L +50.0 12. Any discrepancy noticed in the drawing should be brought to the notice of the chief engineer.
R.L +49.50
R.C.C M 25 13. The minimum cover in bottom raft is 60 mm and in other component 40 mm.
1000 14. Earthen embankment of bund must be negotiated.
10000
15. Angle of internal friction of back fill material of wing wall and abutment should not be less then 30 deg.
16. Joint with water seal shall be provided at all junction of structure.
20 mm # @ 220 mm c/c both face 17. The actual dimension of block outs , embedded parts & gate shall be obtained from gate design.
18. Reinforcement in H/R abutment , wing wall are same as main structure.
16 mm # @ 170 mm c/c both face

HYDRAULIC PARTICULARS OF WEIR


SHEET PILE LINE

R.L +43.00 R.L +43.00


R.L +54.90 R.L +54.90

12 mm # @ 300 mm c/c in both face 12 mm # @ 300 mm c/c in both face


7450 9000 2000 2000 4500 10000 4950
16 mm # @ 280 mm c/c in both face 16 mm # @ 280 mm c/c in both face

27500

R.L +50.00

SECTION AT X - X :H/R R.L +48.80

13200

SECTION AT A - A :H/R

AXIS OF H/R

12000 9500 5750

SPECIFICATION OF MATERIAL TO BE USED

500
5000

500
X
X
1000

1200X1200X600 C.C BLOCK OVER


600

1200X1200X600 C.C BLOCK OVER


300 MM THICK GRADED FILTER
300 MM THICK GRADED FILTER
2000

9000 2000 2000 4500 10000


1000

FLOW

500
5000
5000

GOVT. OF BIHAR
2500 2500 2500 2500
2750 2750 WATER RESOURCES DEPARTMENT
3500 3500 3500
CHIEF ENGINEER , IRRIGATION CREATION W.R.D DARBHANGA
10500 11000 6000
CONSTRUCTION OF GATED WEIR & ALLIED STRUCTURES IN THE
27500 RIVER SUGERWAY AT MADANPATTI , PHULPARAS BLOCK MADHUBANI

A
Western Kosi Canal division Design and Mont. Division Western Kosi Canal Circle
Jhanjharpur Darbhanga Jhanjharpur

Approved by

Design and Mont. Circle

LAYOUT PLAN OF MADANPATTI WEIR H/R


IRRIGATION CREATION W.R.D DARBHANGA
Darbhanga

You might also like